Soyal UDP UPDATER Owner's manual

Category
Gateways/controllers
Type
Owner's manual
Software Manual
UDP UPDATER
System Requirements
SOYAL Website
Operating System: Win7/ Win10, Windows Server 2012/2016/2018, hyper V
Processor Server: Intel® Pentium® and above
Installed Memory (RAM): min. 8GB
Hard Disk: 80GB of free space
Built-in 10/100M RJ-45 networking and USB transmission interface
SOYAL Software Series
V221201
01
02
01
1
2
3
09
09
4
Main Features
Table of Contents
....................................................................................
UDP UPDATER Main
Feature Introduction
Software Operation
2-1 Execute UDP UPDATER.......................................
2-2 Software Communication Port..............................
3-1 UDP UPDATER Operation Precaution..................
3-2 Enterprise Series Controller Firmware Update
(via COM Port)......................................................
3-3 Enterprise Series Controller Firmware Update
(via TCP/IP)...........................................................
3-4 Enterprise Series Controller Customize LCD
Display Image........................................................
3-5 Range Scan SOYAL Devices Under the
Same Network.......................................................
3-6 Change IP Address of SOYAL Devices Under
the Same Network.................................................
03
04
05
06
07
08
Reference 4-1 FAQ .....................................................................
4-2 YouTube Videos....................................................
SOYAL TECHNOLOGY CO., LTD
SOYAL Software Series
UDP UPDATER
1.
2.
1
Main Features
UDP UPDATER Main Feature Introduction
Suitable for rmware update of SOYAL devices via COM port or via TCP/IP connection.
After installing SoyalToolSetup, UDP UPDATER shortcut will be automatically
created. Double click to run UDP UPDATER
(Note: If your computer has running 701 Server software, you need to close 701Server before running this
software to avoid communication port being occupied)
Another method to run UDP UPDATER, on your computer > Start > Soyal Software
folder > click to run UDP UPDATER
After installing SoyalToolSetup , run UDP UPDATER software
Applicable Models:
(1)Enterprise Series(E Series) Controller (only support updating via AR-321CM or
through TCPIP directly)
(2) 16 Doors Networking Control Panel AR-716-E16
(3) Modbus Gateway (TCP-RTU) TCP to Wiegand Converter Built-in I/O
AR-727-CM-IO-0804M
(4) Serial-to-Ethernet Server with I/O Module AR-401-IO-0808R
Enterprise Series Controller Customize LCD Display Image
Range Scan SOYAL Devices Under the Same Network
Change IP Address of SOYAL Devices Under the Same Network
1. Main Features /
2. UDP UPDATER Main Feature Introduction
2-1 Execute UDP UPDATER
2
NOTE: H/E series controller couldn't been updated via AR-727CM,
controller updating please connect to PC directly.
SOYAL TECHNOLOGY CO., LTD
SOYAL Software Series
UDP UPDATER
01
1
2
4
3
5
8
9
6
7
1
2
3
4
5
6
10
2-2 Software Communication Port
2. UDP UPDATER Main Feature Introduction
Computer Network Adapter Options
Select and update Firmware
Select and update LCD Font File
Select and update LCD Display Image
Device Communication Mode, Node ID, and Baud Rate Setting
Select Device
727iV3-Serial Server/TCP to Wiegand (V3)
Compatible Model No.
AR-727-CM-IO-0804M / AR-401-IO-0808R / AR-716-E18-A (its Ethernet module update only AR-727i-V3)
SOYAL TECHNOLOGY CO., LTD
SOYAL Software Series
UDP UPDATER
02
7
9
8
10
Progress Display
Scan connected SOYAL devices IP address on the Subnet
Change Device Network Connection Setting
Close Program
331E/327E/721Ev2/725Ev2/727Ev5/881E/821Ev5/837E/EF
Compatible Model No.
AR-331-E / AR-725-E / AR-327-E / AR-727-E / AR-837-E / AR-837-EE / AR-837-EF / AR-837-EL /
AR-837-EA / AR-837-W / AR-716-E16(AR-721E-V2)
2. UDP UPDATER Main Feature Introduction
3. Software Operation
Software Operation
3-1 UDP UPDATER Operation Precaution
1
2
STEP 1 : LCD Access Controller press "#" then controller will show Node ID
STEP 2 : Keypad Access Controller
If you use RS-485 communication, you need to confirm the Node ID of the controller you
want to operate. If you don’t know the Node ID of the controller, you can refer to the following
operations:
If Node ID is unknown but programming code is known, reset the Node ID by
command 00*NNN#
Step by Step:
Enter programming mode > enter command 00*
If you want to change the Node ID of the controller into 1(default Node ID) for example, enter default
programming code *123456# then press 00*001# (set as Node ID 1)
If both Node ID and programming code is unknown, reset the controller by
pressing RESET button Node ID will restore as Node ID 1
When controller is connected to power supply, press "RESET" button until controller blinking its red
LED then release it. The controller will also restart afterward.
Note: by pressing the RESET button, all controller parameter setting will be restore into default value.
3.
SOYAL TECHNOLOGY CO., LTD
SOYAL Software Series
UDP UPDATER
03
36
7
2
1
3-2 Enterprise Series Controller Firmware Update (via COM Port)
3. Software Operation
STEP 1 : Select the COM Port that connected device to the computer, and enter Node
ID (default Node ID 1)
STEP 2 : Select Device model number
STEP 3 : Press Load F/W
STEP 4 : Select rmware le
Note: unmatched rmware le could cause error when operating the controller after rmware
update, please make sure the rmware is matched with device model no.
STEP 5 : Select Open
STEP 6 : Select Update F/W
STEP 7 : Update rmware status will show on the progress bar. When it shows
'CONTROLLER Programming Completed!' indicated Update Firmware has
been successfully.
It is suggested to press RESET button after rmware update.
4
5
SOYAL TECHNOLOGY CO., LTD
SOYAL Software Series
UDP UPDATER
04
3. Software Operation
STEP 1 : Select PC's Network Adapter that is under the same Subnet as device's IP address. example:
PC Net Adapter is 192.168.1.82, controller's IP address is 192.168.1.174
STEP 2 : Enter Device IP Address, Port remain as default value '1604', enter Device Node ID
STEP 3 : Select Device model number
STEP 4 : Press Load F/W
STEP 5 : Select rmware le
Note: Unmatched rmware le could cause error when operating the device after rmware update,
please make sure the rmware is matched with device model no.
STEP 6 : Select Open
STEP 7 : Select Update F/W
STEP 8 : Update rmware status will show on the progress bar. When it shows 'CONTROLLER
Programming Completed!' indicated Update Firmware has been successfully.
It is suggested to press RESET button after rmware update.
3-3 Enterprise Series Controller Firmware Update (via TCP/IP)
1
2
3
8
7
5
6
4
FAQ : How to update E/V5 series controllers via RS-485?
FAQ : How to Upgrade Firmware via BootLoader Mode on E Series Controller
MORE :
SOYAL TECHNOLOGY CO., LTD
SOYAL Software Series
UDP UPDATER
05
6
7
1
2
3
4
5
3-4 Enterprise Series Controller Customize LCD Display Image
3. Software Operation
Customize LCD Display Image Format:
Dimension: 128px X 32px
File format: bmp
File size: approx. 1kB
Note: Image must be two colors (not black & white)
(Only for Enterprise Series Controller with LCD display)
STEP 1 : Select the COM Port of the actual connected device
STEP 2 : Select Device model number
STEP 3 : Press Load Image
STEP 4 : Select image le
STEP 5 : Select Open
SOYAL TECHNOLOGY CO., LTD
SOYAL Software Series
UDP UPDATER
06
6
8
1
2
5
34
STEP 6 : Select Update Image to change LCD Display Image
STEP 7 : Changing LCD Display Image status will show on the progress bar. When it
shows ‘Programming: 100% done.' indicated Update Image has been
successfully done.
STEP 8 : Restart controller to show the new LCD Display Image
STEP 1 : Select PC's Network Adapter that is under the same Subnet as device's IP address.
example: PC Net Adapter is 192.168.1.82, controller's IP address is 192.168.1.174
STEP 2 : Enter Device IP Address, Port remain as default value '1604', enter Device Node ID
STEP 3 : Press Range Scan
STEP 4 : Press Range Scan
STEP 5 : Progress Bar will show in sequence the IP address of the range scan, and once it is
done the progress bar will show 'Scan Completed'
STEP 6 : Search result will show SOYAL devices in the intranet based on the IP Range Scan:
display the device’s IP location, MAC location, and device rmware version. Device that
is not showed have a possibilities of disconnection to the network.
3. Software Operation
3-5 Range Scan SOYAL Devices Under the Same Network
Before After
SOYAL TECHNOLOGY CO., LTD
SOYAL Software Series
UDP UPDATER
07
4
31
2
3-6 Change IP Address of SOYAL Devices Under the Same Network
3. Software Operation
STEP 1 : Select PC's Network Adapter that is under the same Subnet as device's
IP address. example: PC Net Adapter is 192.168.1.82, controller's IP address
is 192.168.1.174
STEP 2 : Enter the New IP Address of the device, New Netmask, and New Gateway.
Next step is to press the Change IP button.
STEP 3 : The IP setting eld will change to the specied IP Address
STEP 4 : Progress Bar will display 'UPDATE SUCCESSED and Reboot Device!'
indicated setting has been changed and restart the devices.
SOYAL TECHNOLOGY CO., LTD
SOYAL Software Series
UDP UPDATER
08
4.
4. Reference
How to know the details of SOYAL equipment in network?
How to reset after a failure of updating E-series controller´s firmware?
Support to Search Multi Devices´IP Address & MAC Address and also be able to
modify IP address directly.
Firmware UpdatingISP Tools & UDP Updater Setting step
Firmware UpdatingISP Tools & UDP Updater Operation example
Firmware UpdatingUDP Updater Operation example
FAQ
YouTube Videos
Reference
4-1
4-2
SOYAL TECHNOLOGY CO., LTD
SOYAL Software Series
UDP UPDATER
09
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Soyal UDP UPDATER Owner's manual

Category
Gateways/controllers
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI