BVP282 LED120 CW FG SY5WB 100W PSU SPD

Philips BVP282 LED120 CW FG SY5WB 100W PSU SPD, BVP282 Tango G2 Gen 4.0 Solar User manual

  • Hello! I'm your chat assistant. I've reviewed the Installation Instructions for the PHILIPS Flood Lighting Luminaire BVP282. This document covers crucial aspects such as installation steps, wiring guidelines, and necessary precautions. It also provides maintenance tips for ensuring optimal performance. I'm here to help with any questions you may have about the device.
  • What is the required voltage for the luminaire?
    Can the light source be replaced?
    What is the IP rating of the luminaire?
    What type of junction box should be used?
BVP 282 Flood Lighting Luminaire
Type : BVP282
Light Source : LED’s
Voltage : 240V, 50-60 Hz
IP Classification : IP-66
Net Weight : 2.4 kg
Application : Outdoor use only
Installation
30 mm
L
N
Red/Brown - Live
Grn-Yel - Earth
Black/Blue - Neutral
8-9 mm
1
23
Mounting Angle
D
C
All dimensions are in mm.
AB
A
Type E
B
A
D
C
E
M8 Screw with spring
washer and flat washer
52100W 203
264 300
160
Gland
Center Line
Note: Mounting Screw Size : M8
Adjust the aiming of the luminaire
and tighten the mounting screws on
the side for locking in position using
a torque of 8 N-m.
Use proper junction box of IP66
protected for termination of the wire
to ensure electrical safety and
product performance.
(Junction Box is not part of the supply)
Installation Instruction
All the pictures in the MI sheet are representative only and may vary from the actual product. All the pictures in the MI sheet are representative only and may vary from the actual product.
Warning
Maintenance
Caution
1. The luminaire shall be installed by a qualified electrician.
2. Turn power off before inspection, maintenance, installation or removal.
3. Refer to technical datasheet for additional electrical properties to ensure safe
installation.
4. Luminaire installed must not be in contact with combustible materials.
5. Ensure power supply cables (L-N-E) are connected correctly before
Switching on.
6. The connection of power cable on luminaire is type Y. If the external flexible
cable or cord of the luminaire is damaged, it shall be exclusively replaced by
the manufacturer or his service agent or a similar qualified person in order to
avoid hazard.
7. The light source of this luminaire is not replaceable, when the light source
reaches its end of life the whole luminaire shall be replaced.
8. Warranty void if earthing is not connected.
1. Periodic cleaning of the luminaire glass cover will ensure max. optical
Efficiency.
2. Luminaire glass cover shall be cleaned with water and non-abrasive
soap, cleaner or detergent solution.
1. The luminaire must be used within the applicable product specifications,
installation instructions and environmental conditions for storage & operations
according to applications guidelines provided by Philips for product Warranty
to be valid.
2. In case the front glass is found broken/ damaged, it should not be powered on
and is to be replaced before using the luminaire.
Caution: Gland shall never be
above the centre line.
Mounting Angle
D
C
All dimensions are in mm.
AB
A
Type E
B
A
D
C
E
52100W 203
264 300
160
Note: Mounting Screw Size : M8
/