Legrand Security Interface Conditioning Unit, IS-0211 Installation guide

Type
Installation guide
301 Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com
Page 1 of 2
INSTRUCTION/INSTALLATION SHEET
SECURITY INTERFACE CONDITIONING
UNIT
IS-0211 REV. A
©Copyright 2006 by On-Q/Legrand All Rights Reserved.
1. Introduction
The On-Q/Legrand Security Interface Conditioning Unit, PN
364602-01, provides RJ31X functionality to allow the security
system to seize Line 1 and report an alarm. The other 3 lines
are passed through the unit to distribution. The Security
Interface Conditioning Unit mounts to an On-Q Telecom
Service Conditioning Module, PN 364599-01, which can be
mounted into any On-Q style enclosure. See Figure 1.
2. Description
The Security Interface Conditioning Unit is a red unit with a
captive mounting screw, for mounting to the Service
Conditioning Module. The unit has three (3) RJ45 connectors
for interfacing to the telephone distribution network. The unit
is packaged with a six inch Cat 5e Jumper (PN 363201-27).
3. Installation
A. Mounting the Unit to the Service Conditioning Module
(see Figure 2)
1. Install the Telecom Service Conditioning Module in
Enclosure per instructions included with module (ref.
IS-0204).
Note: The Enclosure and module must be properly
installed and grounded for Surge Conditioning Units
to function.
2. Position the unit on the module by aligning the tab
on the housing with one of the three (3) recess cuts
on the module.
Note: Up to three (3) Conditioning Units may be installed, in series, on a single module. It is
recommended that the Surge Unit be the first unit in series from the incoming service.
3. Align the captive screw with the appropriate threaded insert. Use a Philips screwdriver to attach unit to
the module.
B. Connecting to the Telecom Network (see Figure 3)
1. Incoming Service is to be terminated into an RJ45 plug. This may be through an EZ-RJ45 Modular Plug, PN
364554-01, being terminated to the incoming service cable; or, by using a Cat 5e Jumper cable from the
service, terminated to an RJ45 interface, such as the On-Q Network Interface, PN 363486-01.
2. Connect the Line Out to the Telephone Distribution System or the next Conditioning Unit in series. Use the
Cat 5e Jumper provided.
3. Connect the security system with the RJ31X cable provided with the security system.
Figure 1
Figure 2
301 Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com
Page 2 of 2
INSTRUCTION/INSTALLATION SHEET
SECURITY INTERFACE CONDITIONING
UNIT
IS-0211 REV. A
©Copyright 2006 by On-Q/Legrand All Rights Reserved.
NOTE: The circuit will be open unless (or until) the security system is interfaced.