INTRODUCTION/TABLEOFCONTENTS StepOne
Anultrasonicsoundwave is pulsed twotimespersecondfromthebaseof the transducer.Thesoundwave
reflects against the process medium below and returns to the transducer.The microprocessor based
electronics measure the time of flight between the sound generation and receipt, and translates this figure
intothedist
ancebetweenthetransmitterandprocessmediumbelow.
TableofContents
Specifications/Dimensions:....................................................................................................................................................4
Components:.............................................................................................................................................................4
SafetyPrecautions..................................................................................................................................................................5
MakeaFailSafeSystem:..........................................................................................................................................5
Menu/Definitions..................................................................................................................................................................6
Programming: ......................................................................................................................................................................8
StepsforBasicConfiguration:...................................................................................................................................8
SelectingUnitsofOperation:....................................................................................................................................8
ConfigureSensor’sCurrentRange:...........................................................................................................................9
SetOperationalRan
geUsingMAXR&MINR:.........................................................................................................10
Wiring ....................................................................................................................................................................11
Installation....................................................................................................................................................................12
MountingGuide.......................................................................................................................................................12
FittingSelection.......................................................................................................................................................13
TankAdapter...............................................................................................................................................13
Riser............................................................................................................................................................13
Flange..........................................................................................................................................................13
SideMountFitting......................................................................................................................................14
StandPipe...................................................................................................................................................14
Appendix: ....................................................................................................................................................................15
Retur
ntoFactorySettings:.....................................................................................................................................15
ChangeDisplayUnits:.............................................................................................................................................15
Troubleshooting:..................................................................................................................................................................16
OtherHints:.............................................................................................................................................................17
Testingthetransmitter:..........................................................................................................................................18
UserSettings:..........................................................................................................................................................18

4
SPECIFICATIONS/DIMENSIONS StepTwo
Range: 0.5to18feet(15cmto5.4m)
Accuracy: ±0.25%ofspaninair
Resolution: 0.125”(3mm)
Frequency: 50kHz
Pulserate: 2pulsespersecond
Beamwidth: conical
Deadband: 0.5’(15cm)minimum
Blockingdistance: 0.5to18feet(15cmto5.4m)
Displaytype: 4segmentLCD
Displayunits: Inchorcm
Memory: Nonvolatile
Supplyvoltage: 1232VDC
Maxloopresistance: 900Ohms@32VDC
Signaloutput: 420mA,1232VDC
Signalinvert: 420mA/204mA
Configuration: Pushbutton
FailSafediagnostics: Revertto4mA,22mAor
remainsconstant
Temperaturerating: F:‐40°to140°
C:‐40°to60°
Temp.compensation: Automaticoverentirerange
Pressurerating: 30psi(2bar)@25°C.,
derated@1.667psi(.113
bar)per°C.above25°C.
Enclosurerating: NEMA4X(IP65)
Enclosurematerial: Polypropylene(PP),U.L.94VO
Transducermaterial: PolyvinylideneFluoride
(PVDF)
Processmount: 2”NPT(2”G)
Conduitentrance: Single,1/2”NPT
CEcompliance: EN500822immunity
EN55011emission
Components:
P/N Max.Range DeadBand
LVU201A 18.0’(5.4m) 6”(15.2cm)

5
SAPETYPRECAUTIONS StepThree
About this Manual: PLEASE READ THE ENTIRE MANUAL PRIOR TO INSTALLING OR USING THE PRODUCT.
This manual includes information on all four versions of the continuous ultrasonic level transmitter from
OmegaEngineering, modelLVU201A.Pleaserefer tothe partnumber located on the sensor labelto verify
theexactmodelwhichyouhavepurchased.
User’sResponsibilityforSafety:OmegaEngineeringmanufacturesawiderangeofliquidlevelsensorsand
technologies.Whileeachofthesetechnologiesaredesignedtooperateinawidevarietyofapplications,itis
the user’s responsibility to select a technology that is appropriate for the application, install it properly,
perform tests of the installed system, and maintain all components.The failure to do so could result in
propertydamageorseriousinjury.
ProperInstallationandHandling:Becausethisisanelectricallyoperateddevise,onlyproperlytrainedstaff
shouldinstalland/or repair this product.Use a proper sealant with all installations.Never over tighten the
transmitterwithinthefitting.Alwayscheckforleakspriortosystemstartup.
Wiring and Electrical: A supply voltage of 1232 VDC is used to power the LUV201A.The sensor system
shouldneverexceedamaximumof32VDC.Electricalwiringofthesensorshouldbeperformedinaccordance
withallapplicablenational,state,andlocalcodes.
TemperatureandPressure:TheLVU201Aisdesignedforuseinapplicationtemperaturesfrom‐40°C( 40
°F)to60°C(140°F),andforuseatpressuresupto30psi@25°C,derated@1.667psiper°Cabove25°C.
Material compatibility: The continuous ultrasonic level transmitter, LVU201A, is made of two materials.
The enclosure is of Polypropylene (PP) and the transducer is made of Polyvinylidene fluoride (PVDF).Make
surethatthemodelwhichyouhaveselectedischemicallycompatiblewiththeapplicationliquids.Whilethe
transmitterhousingisliquidresistantwheninstalledproperly,itisnotdesignedtobeimmersed.Itshouldbe
mountedinsuchawaythatitdoesnotnormallycomeintocontactwithfluid.
Flammable, Explosive and Hazardous Applications: DO NOT USE THE LVU201A GENERAL PURPOSE
TRANSMITTERINHAZADROUSLOCATIONS.
Makea Fail SafeSystem: Design a fail–safesystem thataccommodatesthe possibility oftransmitter or
powerfailure.Incriticalapplications,OmegaEngineeringrecommendstheuseofredundantbackupsystems
andalarmsinadditiontotheprimarysystem.

6
MENU/DEFINITIONS StepFour
Gettingaround:TheLVU201Aisconfiguredbytheuseoffourpushbuttons(UP,DOWN,MENUandSET)and
aLCDdisplay.The displaywillalwaysreadthedistancefromthebottomofthesensortothesurfaceofthe
liquid(airgap).
MainMenu:HoldingdowntheMENUbuttonwillscrolldownthemainmenuoftheLVU201A.
Definitions:
EC4:Thisisthe4mAsettingfortheLVU201A.TheEC4isthedistancefromthebottomoftheLVU201Ato
the4mAsetpoint.Typically,theEC4or4mAsettingisatthebottomofthe
tank.Thefurtherawayfromthesensor,thelargerthenumberwillbe.This
settingismeasuredineitherinchesorcentimetersonthedisplay.
EC20:Thisisthe20mAsettingfortheLVU201A.TheEC20isthedistance
from the bottom of the LVU201A to the 20 mA set point.Typically, the
EC20or20mAsettingisatthetopofthetank.Theclosertothesensor,the
smaller the number will be.This setting is measured in either inches or
centimetersonthedisplay.
Reversingthe420mAsignal:SettingtheEC4atthebottomofthetankand
EC20 at the top of the tank will create a 420 mA output that has 4 mA at
emptyand20mAatfull.Toreversethe420mAsignal,simplysetEC4atthetopofthetankandEC20atthe
bottomofthetank.
SAF1/SAF2/SAF3:ThisisthefailsafesettingfortheLVU201A.UsetheSAF_settingtodetermine afail–safe
modeforthecurrentsignal.When[SAF1]isset,thecurrentwillincreaseto22mAifthesignalbecomesLOST.
When [SAF2] is set, the current will decrease to 4 mA if the signal becomes LOST.When [SAF3] is set, the
currentwillremainconstantifthesignalbecomesLOST.
LOST:ALOSTstatewilloccurwhenthesensordoesnotreceiveareturnsoundpulsesignal.Whenthis
occurs,thedisplaywillshowLOSTandthe curr
entoutputwilldefaulttotheSAF_setting.Thesensor
will remain in this condition until a valid signal is acquired.No values in the MENU can be changed
untiltheLOSTconditionhasbeenresolved.

7
MENU/DEFINITIONS StepFour
FAST/SLOW:SettingforechoaveragingaswellasthereactiontimeforSAF_settingintheLVU201A:
FAST:Is the typical and default setting for the
LVU201A to operate.The LVU201A will
average 2 signal responses per second and
updateeverysecond.In FASTmode, the sensor
willcontinue to search fora valid readingfor 30
secondsbeforegoingintotheLOSTstate.
SLOW:Is designed to help dampen out effects
causedbysevereturbulence.TheLVU201Awill
average signal returns over the preceding 10
seconds.In SLOW mode, the sensor will
continue to search for a valid reading for 2.5
minutesbeforegoingintotheLOSTstate.
TochangetheFAST/SLOWsetting,followthestepsbelow:
1. Hold[MENU]keyuntilFASTorSLOWappearsinthedisplay.
2. Release[MENU]keyandhold[SET]keytotogglebetweenFASTandSLOW.
3. Whendesiredsettingisreached,release[SET]key.Thelastdisplaysettingwillbelockedintomemory.
ALIN:Usethismodeasanaidtolevelingthesensorinstalledinaselfaligningorrotationalbulkheadfitting.
DisplaywillshowthereturnsignalstrengthindB’s.Foroptimumalignment,firstenergizetheunitandreceive
a valid return signal.Then select the ALIN mode and adjust the LVU201A until the display is maximized.
Typicalreadingsrangebetween2and60dB’s.
ON/OFF:ThisistheactualactivationsettingforALINmode.Defaultis[OFF].Setto[ON]toviewtheALIN
readings.TheALINmodemustbeturned[OFF]whenalignmentiscompleted.
ToALINasensor,followthestepsbelow:
1. Hold[MENU]keyuntilOFFappearsinthedisplay.
a. OFFwillappearrightafterALIN
2. Release[MENU]keyandimmediatelyhold[SET]keytotogglefromOFFtoON.
3. Release[SET]key.TheLVU201AisnowinALINmode.
4. Adjustthesensorsothedisplayshowsthelargestvalue.
a. Whenthehighestvalueisshown,lockthesensorinplace.
5. ToexitALINmode,repeatsteps14changingfromONtoOFF.
MAXR:The MAXR se
ts the maximum tank height and will filter out all returns greater that this value.
Regardless of how the EC4 and EC20 are set, set MAXR to the Empty tank
distanceorgreater.
(VALUE):The number after MAXR shows the setting for MAXR.This value is
the actual MAXR setting that can be changed for the application.The
maximumdistanceis216.0inches.
MINR:TheMINRvalueisthedeadbandclosesttothetransducerfacewhere
nosignalwillbegenerated.TheMINRsetstheminimumdistancebetweenthe
liquid and the transducer.Regardless of how the EC4 and EC20 are set, set
MINRtotheFULLtankdis
tance.
(Value):ThenumberafterMINRshowsthesettingforMINR.Thisvalueisthe
actualMINRsettingthatcanbechangedfortheapplication.Theminimumdistanceis6.0inches.
8
PROGRAMMING StepFive
StepsforBasicConfiguration:
1. SelectandSettheunitsofoperation.
2. ConfiguretheSensor’sCurrentRangeusingtheEC4andEC20settingsinthemainmenu.
a. Thetankleveldoesnotneedtobeemptyorfullforthisoperation.
3. SettheOperationalRangeusingtheMAXRandMINRsettingsinthemainmenu.
a. Thetankleveldoesnotneedtobeemptyorfullforthisoperation.
4. SelecttheFailSafesettingusingtheSAF_settinginthemainmenu.
SelectingUnitsofOperation(InchesorCM):
The default for the LVU201A is to display in inches.If power is removed, the sensor will remain in the
selected mode.This operation selects the units of operation for the configuration of the transmitter.This
selection has no effect on the output of the sensor.The 420 mA output can be scaled to read in any
engineeringunits.
Tocha
ngetocentimeters Tochangetoinches

1. RemovepowertotheLVU201Aandwait10
seconds.
2. Simultaneouslypress[]and[SET]whileadding
powertothetransmitter.
3. TheLVU201Awillnowreadincentimeters.
1. RemovepowertotheLVU201Aandwait10
seconds.
2. Simultaneo
uslypress[]and[SET]whileadding
powertothetransmitter.
3. TheLVU201Awillnowreadininches.

9
PROGRAMMING StepFive
ConfiguretheSensor’sCurrentRangeusingEC4andEC20
EC4:
1. Measure the distance from the bottom of the sensor to the
desiredEC4setpoint.
2. Hold[MENU]keyuntilEC4appearsindisplay.
3. Release[MENU]keyandwaituntilavalueappears.
a. The value that appears is the current distance from the
sensortothesurfaceoftheliquid.
4. Immediatelypress the [] or [] keys to view the memory value
forEC4.
5. Usethe[]or[]keystoraiseorlowerthedisplaytothedesired
value.
a. Ifthekeysremainuntouchedformorethan3seconds,the
sensorwillexitthemenu.
6. Pressthe[SET]keytoenterthisvalueasthenewEC4setpoint.
EC20:
1. MeasurethedistancefromthebottomofthesensortothedesiredEC20setpoint.
2. Hold[MENU]keyuntilEC20appearsindisplay.
3. Release[MENU]keyandwaituntilavalueappears.
a. Thevaluethatappearsisthecurrentdistancefromthesensortothesurfaceoftheliquid.
4. Immediatelypressthe[]or[]keystoviewthememoryvalueforEC20.
5. Usethe[]or[]keystoraiseorlowerthedisplaytothedesiredvalue.
a. Ifthekeysremainuntouchedformorethan3seconds,thesensorwillexitthemenu.
6. Pressthe[SET]keytoenterthisvalueasthenewEC20setpoint.

10
PROGRAMMING StepFive
SetOperationalRangeusingMAXRandMINR
MAXR:
1. Measurethedistancefromthebottomofthesensortothedesired
MAXRsetpoint.
2. Hold[MENU]keyuntilthevalueafterMAXRappearsinthedisplay.
a. ThisvalueisthecurrentMAXRsetting.
3. If this is acceptable, press [SET] to lock the value as the MAXR
setting.Ifnot,usethe[]or[]keystoraiseorlower thevalueto
thedesiredsetting.
4. Pressthe[SET]keytoenterthisvalueasthenewMAXRsetting.
MINR:
1. Measurethedistancefromthebottomofthesensortothedesired
MINRsetpoint.
2. Hold[MENU]keyuntilthevalueafterMINRappearsinthedisplay.
a. ThisvalueisthecurrentMINRsetting.
3. Ifthisisacceptable,press[SET]tolockthevalueastheMINRsetting.Ifnot,usethe[]or[]keys
toraiseorlowerthevaluetothedesiredsetting.
4. Pressthe[SET]keytoenterthisvalueasthenewMINRsetting.
SelecttheFailSafeSetting
SAF_:
1. Hold[MENU]keyuntilSAF1,SAF2,orSAF3appearsinthedisplay.
2. Release [MENU] key and hold [SET] key to toggle between SAF1,
SAF2andSAF3.
3. Whendesiredsettingisreached,release[SET]key.Thelastdisplay
settingwillbelockedintomemory.

11
WIRINGGENERALPURPOSE StepSix
TheLVU201Arequires1232VDCpowerwithatleastwith25mAsupplyinordertooperate.
WiringtotheLVCN51LevelController:

WiringtoaGenericLoopPoweredDisplay:
WiringtoaGenericPLC

12
INSTALLATION StepEight
The LVU201A should always be mounted perpendicular to the liquid.Make sure that the fitting and
transmitter threads are not damaged or worn.Always handtighten the transmitter within the fitting.
Performaninstalledleaktestundernormalprocessconditionspriortosystemstartup.
MountingGuide
1. Donotmountatanangle
2. Liquidshouldneverenterthedeadband
3. SideWall‐UsetheBeamWidthdatatofindtheclosestthesensorcanbetothesidewall
4. Donotmountwhereobstacleswillintrudeonsensor’sbeamwidth
5. Donotmountinavacuum
6. Avoidmountinginthecenterofadometoptank.
7. Inconebottomtank,positionthesensoroverthedeepestpartofthetank.
DonotinstallLVU
201Aatanangle
AvoidInterference
fromsideoftank
Donotinstallwith
objectsinthebeam.
Donotinstallin
applicationswith
vacuum.
Installation in existing fittings:If the existing fitting is larger than the threads of the
LVU201A, select a reducer bushing such as LVU8002N80 (3”thread x 2”thread) or
LVU8003N80(4”threadx2”thread).
Beam Angle:LVU201A features an beam angle.As the distance to the liquid
increases, the beam will increase in size.Keep any object that can interfere with the
soundpulsesoutsideofthisbeamangle.Usethedataprovidedtosizethefootprintof
thesoundpulse.
Depth Radius Depth Radius Depth Radius
1’ 1.2” 7’ 6.2” 13’ 11.3”
2’ 2.1” 8’ 7.1” 14’ 12.1”
3’ 2.9” 9’ 7.9” 15’ 13.0”
4’ 3.7” 10’ 8.8” 16’ 13.8”
5’ 4.6” 11’ 9.6” 17’ 14.6”
6’ 5.4” 12’ 10.4” 18’ 15.5”
13
INSTALLATION StepEight
FittingSelection:LVU201Aiscommonlyinstalledintankadapters,flanges,bracketsorstandpipes.
1. TankAdapter:Selectatankadapter
fitting,suchastheLVU8002Bforthe
LVU201Aseries.
a. Avoidtankadapter(threadx
thread)stylesand/orpipestops
forwardoftheinstalled
transducer.
a. Forlargertankadapters,itis
OKtouseareducerbushing
suchastheLVU8002N80(3”
threadx2”thread).
2. Riser:Installationswithtall,narrowriserscanimpedetheacousticsignal.
a. 2”(5cm)diameterrisersshouldbenotallerthan3”(7.6cm).Largerdiameterrisersshouldbe
notallerthan12”(30.5cm).
RiserSpecifications
InnerDiameter MaximumHeight
3”~(75mm)
4”~(100mm)
5”~(125mm)
6”~(150mm)
7”~(175mm)
8”~(200mm)
3”~(75mm)
7”~(175mm)
10”~(250mm)
12”~(300mm)
14”~(350mm)
16”~(400mm)
Note:Donotexceedthedimensionslistedabove
3. Flange:Ifinstallingonaflange,selectaflangewithathreadthatisequaltothethreadoftheLVU
201A.
a. Whenusingaflangewithariser,pleaseobservetheriserdimensionalinformationabove.
b. Ifthe size of the flange is largerthan the thread of th
esensor, use a reducer bushing to help
mountthesensor.

2”TankAdapter
SocketxThread
TankAdapter
ThreadxThread
Donotusethreadxthread
14
INSTALLATION StepEight
4. SideMountBracket:Forinstallationsinopentanksandsumps,usethe
LVM30seriessidemountbracket.
a. BeawareofthebeamanglewiththeLVU201Atransmitter.
b. UsetheBeamWidthdatatoavoidhavingthesensor’sbeamaway
fromthesidewall.
5. StandPipe:Astandpipemaybeusedtodampenturbulenceorwhenfoamispresentinthe
application.
a. Pipecanbemadeofanymaterial.
b. Selectaminimum2”IDpipeforthestandpipe.
i. Alargerdiameterpipecanbeused.
c. UseacouplingandreducerbushingtoattachtheLVU201A
tothepipe.
d. Thepipelengthshouldrunthemeasurementspanandthe
bottomofthepipeshouldremainsubmergedatalltimesto
preventfoamfromenteringthepipe.
e. Thepipemustbeacontinuouslengthwithnojoints,
couplingsorextensions.
f. Cuta45°notchatthebottomofthepipeanddrilla
1/4”pressureequalizationholeinthedeadband.
i. Theventholemustbewithinthedeadbandofthe
LVU201A.
g. Thepumpsshouldnotdriveliquidpasttheopenendofthe
standpipewhichcausestheliquidinthepipetooscillate.

15
APPENDIX StepNine
ReturntoFactorySetting:TheLVU201Aispresetattimeofshipmentwiththe
Factory Settings listed below.If at any time you need to return to the Factory
Settings, remove power from the LVU201A and wait 10 seconds.Press the
[MENU] and [SET] buttons simultaneously while powering up the transmitter.
Note: If po wer is cycled on and off or removed for a long duration of time, the
configuration will not change.The only way to return to Factory Settings is to
holdboththe[MENU]and[SET]buttonswhileapplyingpower.
FactorySettings:
EC4 216”(548.4cm) ON/OFF OFF
EC20 8”(20.3cm) MAXR N/A
SAF1/2/3 SAF1 value 216”(548.6cm)
FAST/SLOW FAST MINR N/A
ALIN N/A value 8”(20.3cm)
Changing Display Units: The LVU201A comes preset to measure in inches (default setting).To change the
display to show centimeters or to return to inches, flow the steps below.Note:If power is removed, the
sensorwillremainintheselectedmode.
Tochangetocentimeters Tochangetoinches
1. RemovepowertotheLVU201Aandwait10
seconds.
2. Simultaneouslypress[]and[SET]whileadding
powertothetransmitter.
3. TheLVU201Awillnowreadincentimeters.
1. RemovepowertotheLVU201Aandwait10
seconds.
2. Simultaneouslypress[]and[SET]whileadding
powertothetransmitter.
3. TheLVU201Awillnowreadininches.

16
TROUBLESHOOTING StepTen
PROBLEM SOLUTION
Transmitteroutputs
currentof0mA
Check the wiring for an open circuit.An open circuit is the most
commonissuewitha0mAsignal
Transmitterjumpstoa
currentoutputbetween19
and20mA
Check the installation of the transmitter.Bad installation fittings will
cause false signals near the top of the tank, which typically translates
to a signal between 19 and 20 mA.Also look for interference just
belowthetransmitter.
Transmitteroutputsa
currentover22mA
Immediately check the wiring for a short circuit.The LVU201A is
current limited to 22 mA.Anything above 22 mA indicates a short
circuit.
Transmitteralwaysjumps
toLOSTcondition
A reading of LOST in the display of the LVU201A indicates the
transmitterisnotreceivinga validreturnsignal.IfLOSTappears,please
checkthefollowingtroubleshootingitems:
1. Beamconeinterferencesuchasthesidewall,ladder,seams,rungs
orpipeswithintheLVU201A’sbeamcone.
2. ProperinstallationsuchthattheLVU201Aisinstalledlevelandfree
frominterferencefromtheinstallationfittingorflange.
3. Sufficient power being supplied to the LVU201A.The LVU201A
requires1232VDCwithaminimumsupplyof25mA.
4. Proper Programming of the MAXR or MINR function. For best
results,set theMAXR function asthedistance from the bottom of
the tank to the bottom of the transmitter. Also set the MINR
distanceabovethehighestlevelinthetank.DonotsettheMINRto
lessthan6inches.
5. Makesuretha
tthetransmitter isnotinstalledatanangle.Evena5
degreeoffsetcanreducethesignalreturnstrengthgreatly.
Outputoftransmitteris
oppositeofthelevelof
liquid
Check the EC4
&
EC20 Setting. For 4mA at empty tank and20 mA at
full tank, the EC4 must be the larger value and the EC20 to smaller
value.For20mAatemptytankand4mAatfulltank,theEC20must be
thelargervalueandtheEC4tosmallervalue.

17
TROUBLESHOOTING StepTen
PROBLEM SOLUTION
Thedisplayonthe
transmitterdoesnot
matchthedisplayonthe
sideofthetank
The display for the LVU201A will always show the distance from the
liquidsurfacetothebottomofthesensor(ininchesorcm).The420
mA output can be scaled to read in any engineering units, thus the
displayswillnevermatchunlessthelocal displayisconfiguredtoread
theairgapinthetank.
Sensorappearstohave
resetitself
CheckthesettingsforEC4&EC20.Rememberthatthefirstvalueseen
inEC4&EC20isthecurrentdistancefromthesensortotheliquid.
1. TocheckEC4setting:
a. PressMENUuntilEC4appears.
b. Waituntilanumberappears.
c. Immediatelypressthebutton&theEC4settingwillappear.
2. TocheckEC20setting:
a. PressMENUuntilEC20appears.
b. Waituntilanumberappears.
c. Immediatelypressthebutton&theEC20settingwillappear.
DisplayreadsCM8Qor
CM8O
These are actually firmware codes for the sensor.The appearance of
eithercode indicates that the sensor is stuck in a reboot stage due to
thepowerflickeringonandoff.Checkthatthepower beingsuppliedis
consistentanddoesnotflickeroff.Alsocheckthewireconnectionsat
theterminals.
Other Hints:Current must change with all level movement.Example: For the illustration below, as level
increases, the current output will increase. If the output of the LVU201A is always reading 4mA or 20mA,
checktheinputvaluesfortheLVU201A.
Thedisplayonthe LVU201Awillalwaysindicatethedistancefromthebottomofth
esensortothesurfaceof
theliquid.Astheliquidlevelincreases,thevalueonthedisplaywilldecrease.Astheliquidleveldecreases,
thevalueonthedisplaywillincrease.

18
TROUBLESHOOTING StepTen
TestingtheTransmitter
1. Ifinstalledinaclassifiedarea,removethesensorfromthehazardouslocation beforetesting.
2. Connectamultimeterinserieswiththeblackwiretoreadthecurrentoutput.
3. Verifythatthecurrentincreases(tankfilling)anddecreases(tankemptying)appropriatelyinthe
calibratedspan.
If not, carefully observe and attempt to correlate any installation, level or application event for more specific
troubleshootingdirection.
UserSettings:
Filloutthechartbelowandkeepasarecordofyourconfiguration.
CurrentRange
EC4= EC20=
LoopFailSafe(selectone)
SAF1(22mA) SAF2(4mA) SAF3(HoldLastValue)
OperationRange
MINR= MAXR=


19

20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Omega LVU-201A Owner's manual

Category
Processors
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI