19
Resetable Hours -
The item shows the number of the operation hours that the
Robin 300 Plasma Spot
has been powered on since the counter was last reset.
In order to reset this counter to 0, touch the text box next to the item "Resetable Hours:"
Lamp On Time Hours - Select this menu to read the number of the operation hours with the lamp on.
Total Hours -
The item shows the total number of the operation hours with the lamp
on since
the Robin 300 Plasma Spot has been fabricated.
Resetable Hours -
The item shows the number of the operation hours with the lamp
on that
the Robin 300 Plasma Spot has been powered on since the counter was last reset.
In order to reset this counter to 0, touch the text box next to the item "Resetable Hours:"
Lamp Strikes - Select this menu to read the number of lamp strikes.
Total Strikes - The item shows the total number of the lamp strikes since the
Robin 300 Plasma Spot has been fabricated.
Resetable Strikes - The item shows the number of the lamp strikes since the counter was
last reset.
In order to reset this counter to 0, touch the text box next to the item "Resetable Strikes:"
Fixture Temperatures - The menu is used to view temperatures of the xture´s inside.
Head Temperature - The menu shows temperatures in the xture head near the reector.
Current - A current temperature of the xture head.
Maximum NonRes. - A maximum temperature of the xture head since the xture has
been fabricated.
Maximum Res. - A maximum temperature of the xture head since the counter
was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
Driver Temperature - The menu shows temperature of the plasma source driver in the xture head.
Current - A current temperature of the driver.
Maximum NonRes. - A maximum temperature of the driver since the xture has
been fabricated.
Maximum Res. - A maximum temperature of the driver since the counter
was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
Base Temperature - The menu shows temperature in the xture base (on the display PCB).
Current - A current temperature in the xture base.
Maximum NonRes. - A maximum temperature in the xture base since the xture has
been fabricated.
Maximum Res. - A maximum temperature in the xture base since the counter
was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
Air Filters - Regular cleaning of the air lters is very important for the xture´s life and performance.
Bild-up of dust, dirt and fog uid residues reduces the xture´s light output and cooling ability.
The two items of this menu help you to keep cleaning period of the air lters.
Alert period - Cleaning schedule for the xture depends on the operating environment.
It is therefore impossible to specify accurate cleaning interval. This item allows
you to change the cleaning interval of the air lters. This "alert" value is 300 hours and it
is set as default. Inspect the xture within its 300 hours of operation to see whether cleaning
is necessary. If cleaning is required, clean all air lters and change the value in this menu
on acceptable level. Min. level of alert period is 10 hours, max. is 300 hours.
Elapsed Time - The item allows you to read the time which remains to cleaning air lters.
The time period is set in the menu mentioned above.
Expired time period is signalled by a negative mark (-) at the time value and a warning icon
on the display.
Clean the lters and reset this menu item (by touching the text box next to the item
"Elapsed Time").
DMX Values - The menu is used to read DMX values of each channel received by the xture.
Product IDs - The menu is used to read the MAC Address ,RDM UID and RDM Label.
Software Version - Select this item to read the software version of the xture modules:
Display System - A display processor on the display board in the xture base