Part Number 10400049-102 07/2007 ©2007 Overland Storage, Inc. W Page 4 of 4
7. Operator/Control Panel
The ULTAMUS RAID 1200 front panel incorporates an
Operator’s (OPS) Panel with four LEDs (Figure 8). The
OPS Panel provides a high-level indication of the
operation of the appliance.
NOTE:
The OPS Panel is an integral part of the chassis assembly
and can only be replaced with a replacement chassis. Chassis
replacement should only be performed by trained personnel.
Figure 8. Operator’s Panel LEDs
8. Additional Information
The ULTAMUS RAID 1200 appliance is preconfigured
with default IP addresses:
• 10.1.1.5 for the lower RAID Controller (Controller 0)
• 10.1.1.6 for the upper RAID Controller (Controller 1)
• 10.1.1.7 if an error is detected
• 255.0.0.0 for the subnet mask
IMPORTANT: Do not connect the unit to a DHCP network
before establishing the IP addresses with the host.
Launching ULTAMUS RAID manager
1. In your Web browser on the management system, enter
the applicable IP address to access the array, in the
following format (example):
http://10.1.1.5:9292
2. Use the following default login (case-sensitive):
Logon: admin
Password: password
3. Begin the configuration process.
For detailed instructions on how to connect the ULTAMUS RAID 1200 Storage Appliance to a network, and all other
appliance configuration information, see the ULTAMUS RAID 1200 Setup Guide found on the ULTAMUS RAID 1200
Software and Documentation CD.
All information contained in or disclosed by this document is considered proprietary by Overland Storage. By accepting this material, the recipient agrees that this material and the information contained therein are held in confidence and in trust and will not be
used, reproduced in whole or in part, nor its contents revealed to others, except to meet the purpose for which it was delivered. It is understood that no right is conveyed to reproduce or have reproduced any item herein disclosed without express permission from
Overland Storage. Overland Storage provides this document as is, without warranty of any kind, either expressed or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Overland Storage may make
improvements or changes in the product(s) or program(s) described in this document at any time. These changes will be incorporated in new editions of this publication.
Overland Storage assumes no responsibility for the accuracy, completeness, sufficiency, or usefulness of this document, nor for any problem that might arise from the use of the information in this document.
Table 1: Operator’s Panel LED Definitions
OPS Panel LEDs
Other LEDs or Alarms State Description
Power
On
System
Fault
Logical
Fault
Box
Identify
ON ON ON ON
Single beep, two double beeps Power-On Self Test
ON OFF
Power On, all functions good
ON ON
PSU Fault LED or Cooling Fan
Module Fault LED
Any PSU Fault, Cooling Fan Module Fault, or Over/
Under Temperature Condition
ON ON
RAID Controller Fault LED on the
specific controller
A RAID Controller Fault
ON ON
Drive Fault LED Drive failure has occurred causing loss of availability or
redundancy
ON ON
Array is performing background function such as a
parity check, initialization, or expansion
ON
Chassis identification mode. When illuminated it
identifies the specific chassis
Additional Help
You can get additional technical support on the Internet at http://support.overlandstorage.com, or call
1-877-654-3429 (toll-free U.S. & Canada), +44 (0) 118-9898050 (Europe), or +1 (858) 571-5555 Option 5 (International).