SSP 200

Extron SSP 200 User manual

  • Hello! I am an AI chatbot trained to assist you with the Extron SSP 200 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1
IMPORTANT:
IMPORTANT:
Go to www.extron.com for the complete
user guide, installation instructions, and
specifications before connecting the
product to the power source.
SSP 200 • Setup Guide
The Extron SSP 200 is a high-performance surround sound processor that automatically decodes Dolby
®
, DTS
®
, and PCM
formats from digital input sources to discrete audio outputs. Providing up to ten built-in balanced analog outputs, the SSP200
provides the exibility needed for pro A/V applications in corporate, commercial, and education environments. It supports
the latest immersive formats of Dolby Atmos and DTS:X plus legacy Dolby and DTS formats. An upmix function synthesizes
exceptional multichannel audio from stereo content. The SSP 200 features an HDMI input with loop through, coaxial and optical
digital inputs, and an analog stereo input. It is designed for integration into pro A/V installations, featuring a compact, half-rack
metal enclosure, RS-232 serial and LAN control, and balanced line level outputs.
This guide provides instructions for an experienced user to set up and congure the SSP 200. It covers how to connect
other devices and perform basic operations using rear panel connections and the front panel controls. For full operation and
conguration through Extron Product Configuration Software (PCS), internal web pages, and Simple Instruction Set (SIS™)
commands, see the SSP 200 User Guide.
NOTE: For information while using PCS, see the SSP 200 PCS Help File.
Rear Panel Connectors
50-60 Hz
100-240V
--A MAX
1 THRU
OUTS
DMP EXP
INPUTS
SSP 200
2
5
LR
34
1(LF) 2(RF) 3(C) 4(SUB) 5(LS) 6(RS)789 10(MIX)
RS-232
Tx Rx G
LAN
RESET
e
SSP 200
CONFIG
PCM
2-CH
ATMOS
HDCP
EXP
SURROUND SOUND PROCESSOR
SOURCE INPUT VOLUME
1 2 3 4 5
AAA
AAA CCC
BBB CCC
BBB
H
H
H
DDD EEE
DDD EEE FFFGGG
Figure 1. Rear Panel Connectors
A
AC power connector
B
Audio inputs
C
DMP expansion port
D
RS-232 port
E
LAN port
F
Reset button
G
Status light
H
Analog outputs
The SSP 200 (
A
) uses an IEC power cable to connect to a 100-240 VAC, 50-60 Hz, power source.
The SSP 200 (
B
) accepts one HDMI input with embedded audio, three digital inputs, and one analog input. In addition, there is
an HDMI loop out (through) connector.
Input 1 accepts digital signals through an HDMI cable, supporting HDMI version 2.0 with HDCP version 2.3 compliance.
Input 2 accepts a 75 ohm unbalanced digital coaxial S/PDIF input.
Inputs 3 and 4 accept digital signals through S/PDIF optical (TOSLINK
®
) cables.
Input 5 accepts a balanced or unbalanced, stereo or mono, analog input through a 6-pole captive screw connector.
Connect an EXP-enabled device to the DMP expansion port (
C
) for a digital audio connection using Extron proprietary protocol.
Use the included one-foot long shielded CAT6 cable to connect the SSP 200 to a Primary EXP-enabled device (see the SSP 200
User Guide for EXP bus operation details).
The ten outputs (
H
) are balanced or unbalanced, line level, analog signals made available through captive screw connectors
providing outputs for the following surround sound channels.
Number Abbreviation Channel Description Number Abbreviation Channel Description
1
LF Left front 6 RS Right surround
2 RF Right front 7 See note below
3 C Center 8 See note below
4 SUB Subwoofer 9 See note below
5 LS Left surround 10 See note below
NOTE: Numbers 7 through 10 are configurable as back, height, or downmix channels using PCS.
By default, the SSP 200 is set to 7.1 with downmix enabled with all ten analog outputs enabled. Outputs in this conguration are
7 – Left Back, 8 – Right Back, 9 – Downmix Left, and 10 – Downmix Right.
1
2
SSP200 • Setup Guide (Continued)
Mounting and Cabling
Step 1 Mount the device
a. Turn off or disconnect all equipment power sources.
b. Mount the SSP 200 using optional rack and under-furniture mounting kits (available at www.extron.com), or place on a table
using the provided rubber feet. The SSP 200 is housed in a 1U-high, 8.5 inch deep, half-rack wide enclosure.
Step 2 Connect inputs
Make the following input connections as needed (see figure1,
B
, on the previous page):
Connect digital sources to Inputs 1 through 4 depending on connector type.
Connect balanced or unbalanced analog audio sources to Input 5 through the 6-pole input connector.
Step 3 Connect outputs
Make the following output connections as needed:
Connect balanced or unbalanced analog audio output devices to the captive screw output connector (
H
). Refer to Audio
Wiring on the next page for more information. A representative application diagram is shown below.
ATTENUATION 8Ω/4Ω OUTPUTSREMOTEINPUTS
0
1
1
2
4
6
8
10
12
18
14
26
0
2
1
2
4
6
8
10
12
14
0
3
1
2
4
6
8
10
12
14
0
4
1
2
4
6
8
10
12
14
1
2
3
4
G
STANDBY
CLASS 2 WIRING
1
2
3
4
LIMITER/
PROTECT
SIGNAL
1 2 3 4
100-240V 1.0A, 50-60Hz
XPA U 1004
Tx
RS-232
Rx G
DMP EXP
OUTS
INPUTS
5
1 2 3 4
THRU
RESET
LAN
100-240V --A MAX
50-60Hz
SSP 200
L
R
1 (LF)
2 (RF)
3 (C)
4 (SUB)
5 (LS)
6 (RS)
7
8
9
10(MIX)
ATTENUATION 8Ω/4Ω OUTPUTSREMOTEINPUTS
0
1
1
2
4
6
8
10
12
18
14
26
0
2
1
2
4
6
8
10
12
14
0
3
1
2
4
6
8
10
12
14
0
4
1
2
4
6
8
10
12
14
1
2
3
4
G
STANDBY
CLASS 2 WIRING
1
2
3
4
LIMITER/
PROTECT
SIGNAL
1 2 3 4
100-240V 1.0A, 50-60Hz
XPA U 1004
ATTENUATION
0
1
1
2
4
6
8
10
12
18
14
26
0
2
1
2
4
6
8
10
12
14
1
2
CLASS 2 WIRING
1
2
LIMITER/
PROTECT
SIGNAL
1 2
100-240V 0.6A, 50-60Hz
XPA U 1002
G
STANDBY
REMOTEINPUTS 8Ω/4Ω OUTPUTS
Extron Extron Extron
Extron Extron
100-240V 1.5A, 50-60 Hz
STANDBY
XPA 4002
GREEN - ACTIVE
AMBER - STANDBY
1
G
2
1
LIMITER/
PROTECT
SIGNAL
0
2
4
6
8
10
12
18
14
26
2 1 2
0
2
4
6
8
10
12
18
14
26
ATTENUATION
INPUTS
BRIDGE MODE 8Ω / 4Ω OUTPUTS
REMOTE
ON
OFF
1 2
CLASS 2 WIRING
BRIDGE
8Ω ONLY
(BRIDGE)
BRIDGE
Extron
XPA U 1004
Power Amplier
Extron
SSP 200
Surround Sound
Processor
Extron
XPA U 1004
Power Amplier
Extron
XPA U 1002
Power Amplier
Extron
SM 26
Speakers
HDMI
Audio
Audio
Audio
Ch. 1 & 2
Bridged
Extron
SM 28
Speakers
Extron
XPA 4002
Power Amplier
LF
LS
Extron
SF 26CT
Two-Way Ceiling Speakers
LHF RHF LHB RHB
RS
C RF
Extron
SF 10C SUB
Subwoofer
HDMI Source
Audio
Figure 2. Typical Application Diagram for a 5.1.4 Speaker Setup
Step 4 Connect control devices
To control the SSP 200 through Ethernet, connect a LAN or WAN to the LAN connector (
E
).
For serial RS-232 control, connect a host device to the 3-pole captive screw connector (
D
). The default baud rate is 9600.
For control through USB, connect a host device to the front panel USB mini-B port (see figure3 ,
B
, on the next page).
Step 6 Connect power
Connect a 100 to 240 VAC, 50-60 Hz power source to the AC power connector (figure1,
A
, on the previous page).
2
3
Audio Wiring
Wire the audio input and output connectors as shown at right. Use
the supplied tie wrap to strap the audio cable to the extended tail of
the connector.
NOTE: The length of exposed wires is important. The ideal
length is 3/16 inch (5 mm).
RS-232 Port Wiring
To transmit and receive IR signals, connect a control device to
the three-pole RS-232 connector (
D
) as shown below.
RS-232
Tx Rx G
REMOTE
Transmit
Receive
Ground
Tx
Rx
G
RS-232 protocol defaults
9600 baud no parity 1 stop bit
8 data bits no flow control
Ethernet Connection
The Ethernet cable can be terminated as a straight-through
cable or a crossover cable and must be properly terminated
for your application as shown at right.
Crossover cable — Direct connection between the
computer and the SSP.
Patch (straight) cable — Connection of the SSP to
an Ethernet LAN.
Front Panel Features
50-60 Hz
100-240V
--A MAX
1 THRU
OUTS
DMP EXP
INPUTS
SSP 200
2
5
LR
34
1(LF) 2(RF) 3(C) 4(SUB) 5(LS) 6(RS)789 10(MIX)
RS-232
Tx Rx G
LAN
RESET
e
SSP 200
CONFIG
PCM
2-CH
ATMOS
HDCP
EXP
SURROUND SOUND PROCESSOR
SOURCE INPUT VOLUME
1 2 3 4 5
A
A
A
A
A
A C
C
C
B
B
B C
C
C
B
B
B
H
H
H
D
D
D E
E
E
D
D
D E
E
E F
F
FG
G
G
Figure 3. Front Panel Features
A
Status LED
B
Configuration port
C
Input source format indicators
D
Input selection buttons
E
Volume adjustment knob and LED
bar
A
Status LED — This LED indicates the current power and boot status of the SSP 200. It lights solid green when operational
and solid amber during bootup and reset.
"
(5 mm) MAX. (typ)
3
16
3-pole Audio Input Wiring
Balanced Input
Sleev
e
Ring
Tip
Tip
Sleeve
Jumper
Unbalanced Input
3
Tip
Slee
ve
Ring
Tip
Sleeve
Ring
Tip
Sleeve
Tip
Sleeve
6-pole Audio Input Wiring
Balanced Input Unbalanced Input
Jumper
Jumper
3-pole Audio Output Wiring
Unbalanced Output
Tip
Sleeve
NO Ground Here
Balanced Output
Tip
Sleev
e
Ring
Tip
Sleeve
Tip
Sleeve
Tip
Slee
ve
Ring
Tip
Sleeve
Ring
6-pole Audio Output Wiring
Balanced Output Unbalanced Output
NO Ground Here
NO Ground Here
12345678
RJ-45
Connector
Insert T
wisted
Pair Wires
Pins:
A cable that is wired as TIA/EIA T568A at one
end and T568B at the other (Tx and Rx pairs
reversed) is a "crossover" cable.
A cable wired the same at both ends is called
a "straight-through" cable because no pin/pair
assignments are swapped.
T568B T568A T568B T568B
Straight-through Cable
(for connection to a switch, hub, or router)
End 1 End 2
Pin Wire Color Pin Wire Color
1 white-orange 1 white-orange
2 orange 2 orange
3 white-green 3 white-green
4 blue 4 blue
5 white-blue 5 white-blue
6 green 6 green
7 white-brown 7 white-brown
8 brown 8 brown
Crossover Cable
(for direct connection to a PC)
End 1 End 2
Pin Wire Color Pin Wire Color
1 white-orange 1 white-green
2 orange 2 green
3 white-green 3 white-orange
4 blue 4 blue
5 white-blue 5 white-blue
6 green 6 orange
7 white-brown 7 white-brown
8 brown 8 brown
4
68-3281-50 Rev. A
12 20
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide on the Extron website.
© 2020 Extron — All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876
B
Configuration port — The SSP200 can be configured through PCS or by using SIS commands through this USB mini-B
port or through the LAN and RS-232 ports on the rear panel. In addition, this configuration port is used for firmware updates
from a PC.
C
Input Source format indicators — The bank of eight LEDs identify the format of the audio input.
D
Input selection buttons — Push one of the buttons to select between the five audio inputs. When a button is selected, the
button lights green indicating it is the active input. For digital inputs 1 through 4, the button turns amber when it is selected
and the digital clock signal has not been detected.
E
Volume adjustment knob and LED bar — Use the rotary encoder to adjust the output volume from 0to 100. The default
setting is 80.
Configuration and Operation
Extron PCS
To congure and operate the SSP 200 using PCS, install the software (available on the Extron website, www.extron.com) to
a PC connected to the processor via Ethernet (using the LAN connection) or the front panel USB conguration port. After the
installation, start the program and connect to the device (see the SSP 200 User Guide at www.extron.com). For full instructions
while operating PCS, press <F1> on the keyboard or click the ? button in the software and select Help File.
Toolbelt Software
To manage the SSP 200 using Toolbelt, install the software (available on the Extron website, www.extron.com) to a PC
connected to the processor via Ethernet (using the LAN connection). After the installation, start the program and connect to the
device by using Device Discovery to locate and then select the desired device. For full instructions while operating Toolbelt,
press <F1> on the keyboard or click the Help button in the software and select Toolbelt Help.
Internal Web Pages
To congure the SSP 200 using the factory-installed web pages in a web browser, connect the LAN connector to a LAN or WAN.
The default IP address is 192.168.254.254. There is a limited amount of conguration that can be performed with the web pages
(see the SSP 200 User Guide at www.extron.com).
SIS Commands
To congure the SSP 200 with SIS commands via an RS-232, USB, or Ethernet connection, use the Extron DataViewer utility or
a control system to send and receive SIS commands. For a list of SIS commands and variables, see the SSP 200 User Guide at
www.extron.com.
Firmware Updates
Download rmware updates from www.extron.com to a local computer and upload them via the internal web pages or PCS (see
the SSP 200 User Guide at www.extron.com).
/