INSTALLATION MANUAL
MULTI
AIR
CONDITIONER
www.lg.com
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it
thoroughly.
ENGLISH TÜRKÇE
1,MFL67737205,영영 2018. 6. 15. 영영 11:50 Page 1
2
TIPS FOR SAVING ENERGY
ENGLISH
• Do not cool excessively indoors. This may be harmful to your health and may consume more elec-
tricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Open windows regularly for ventilation as the indoor air quality may deteriorate if the air condition-
er is used for many hours.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the
air flow or weaken the cooling / dehumidifying functions.
For your records
Staple your receipt to this page in case you need it to prove the date of purchase or for warranty
purposes. Write the model number and the serial number here:
Model number :
Serial number :
You can find them labeled on the side of each unit.
Dealer’s name :
Date of purchase :
Here are some tips that will help you minimize the power consumption when you use the air
conditioner. You can use your air conditioner more efficiently by referring to the instructions
below:
TIPS FOR SAVING ENERGY
1,MFL67737205,영영 2018. 6. 15. 영영 11:50 Page 2
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
3
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous
situations and ensure peak performance of your product.
LG Electronics is not responsible for Product`s malfunction or damage
which caused by improper installation or misuse of operation guide.
WARNING
It can result in serious injury or death when the directions are ignored.
CAUTION
It can result in minor injury or product damage when the directions
are ignored.
WARNING
• Installation or repairs made by unqualified persons can result in
hazards to you and others.
• Installation work must be performed in accordance with the
National Electric Code by qualified and authorized personnel only.
• The information contained in the manual is intended for use by a
qualified service technician familiar with safety procedures and
equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual
can result in equipment malfunction, property damage, personal
injury and/or death.
Installation
• Do not use a defective or underrated circuit breaker. Use the
correctly rated breaker and fuse. There is risk of fire or electric
shock.
For electrical work, contact the dealer, seller, a qualified electrician,
or an Authorized Service Center. Do not disassemble or repair the
product by yourself. There is risk of fire or electric shock.
!
!
!
1,MFL67737205,영영 2018. 6. 15. 영영 11:50 Page 3
4
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
• Always ground the product as per the wiring diagram. Do not
connect the ground wire to gas or water pipes lightening rod or
telephone ground wire. There is risk of fire or electric shock.
• Install the panel and the cover of control box securely. There is
risk of fire or electric shock due to dust, water etc.
• Use the correctly rated breaker or fuse. There is risk of fire or
electric shock.
• Do not modify or extend the power cable. If the power cable or
cord has scrathes or skin peeled off or deteriorated then it must
be replaced. There is risk of fire or electric shock.
• For installation, removal or reinstall , always contact the dealer or
an Authorized Service Center. There is risk of fire, electric shock,
explosion, or injury.
• Do not install the product on a defective installation stand. Be
sure that the installation area does not deteriorate with age. It
may cause product to fall.
• Never install the outdoor unit on a moving base or a place from
where it can fall down.
The falling outdoor unit can cause damage or injury or even death
of a person.
• In outdoor unit the step-up capacitor supplies high voltage
electricity to the electrical components. Be sure to discharge the
capacitor completely before conducting the repair work.
An charged capacitor can cause electrical shock.
• When installing the unit, use the installation kit provided with the
product. Otherwise the unit may fall and cause severe injury.
• Indoor/outdoor wiring connections must be secured tightly and
the cable should be routed properly so that there is no force
pulling the cable from the connection terminals. Improper or
loose connections can cause heat generation or fire.
• Safely dispose off the packing materials. Like screws, nails,
batteries, broken things etc after installation or svc and then tear
away and throw away the plastic packaging bags. Children may
play with them and cause injury.
• Be sure to check the refrigerant to be used. Please read the label
on the product. Incorrect refrigerant used can prevent the normal
operation of the unit.
1,MFL67737205,영영 2018. 6. 15. 영영 11:50 Page 4
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
5
Operation
• When the product is soaked (flooded or submerged) in water ,
contact an Authorized Service Center for repair before using it
again. There is risk of fire or eletric shock.
• Be sure to use only those parts which are listed in the svc parts
list. Never attempt to modify the equipment. The use of
inappropriate parts can cause an electrical shock, excessive heat
generation or fire.
• Do not touch , operate, or repair the product with wet hands.
Hold the plug by hand when taking out. There is risk of electric
shock or fire.
• Do not place a heater or other heating appliances near the power
cable. There is risk of fire and electric shock.
• Do not allow water to run into electric parts. Install the unit away
from water sources. There is risk of fire, failure of the product, or
electric shock.
• Do not store or use or even allow flammable gas or combustibles
near the product. There is risk of fire.
• Do not use the product in a tightly closed space for a long time.
Perform ventilation regularly. Oxygen deficiency could occur and
hence harm your health.
• Do not open the front grille of the product during operation. (Do
not touch the electrostatic filter, if the unit is so equipped.) There
is risk of physical injury, electric shock, or product failure.
• If strange sound, smell or smoke comes from
product.Immediately turn the breaker off or disconnect the
power supply cable. There is risk of electric shock or fire.
• Ventilate the product room from time to time when operating it
together with a stove, or heating element etc. Oxygen deficiency
can occur and hence harm your health.
• When the product is not to be used for a long time, disconnect
the power supply plug or turn off the breaker. There is risk of
product damage or failure, or unintended operation.
• Take care to ensure that nobody especially kids could step on or
fall onto the outdoor unit. This could result in personal injury and
product damage.
1,MFL67737205,영영 2018. 6. 15. 영영 11:50 Page 5
6
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
• Take care to ensure that power cable could not be pulled out or
damaged during operation. There is risk of fire or electric shock.
• Do not place ANYTHING on the power cable. There is risk of fire
or electric shock.
• When flammable gas leaks, turn off the gas and open a window
for ventilation befor turning on the product. Do not use the
telephone or turn switches on or off. There is risk of explosion or
fire.
CAUTION
Installation
• Two or more people must lift and transport the product. Avoid
personal injury.
• Do not install the product where it will be exposed to sea wind
(salt spray) directly. It may cause corrosion on the product.
• Install the drain hose to ensure that the condensed water is
drained away properly. A bad connection may cause water
leakage.
• Keep level even when installing the product. To avoid vibration or
noise.
• Do not install the product where the noise or hot air from the
outdoor unit could damage or disturb the neighborhoods. It may
cause a problem for your neighbors and hence dispute.
• Always check for gas (refrigerant) leakage after installation or
repair of product. Low refrigerant levels may cause failure of
product.
• Please install safely at a place that can sufficiently endure the
weight of the product.
(If the strength is not sufficient, the product may fall and cause
injury.)
Operation
• Do not use the product for special purposes, such as preserving
!
1,MFL67737205,영영 2018. 6. 15. 영영 11:50 Page 6
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
7
foods, works of art, etc. It is a consumer air conditioner, not a
precision refrigeration system. There is risk of damage or loss of
property.
• Do not block the inlet or outlet of air flow. It may cause product
failure.
• Use a soft cloth to clean. Do not use harsh detergents, solvents
or splashing water etc. There is risk of fire, electric shock, or
damage to the plastic parts of the product.
• Do not touch the metal parts of the product when removing the
air filter. There is risk of personal injury.
• Do not step on or put anyting on the product. (outdoor units)
There is risk of personal injury and failure of product.
• Always insert the filter securely after cleaning. Clean the filter
every two weeks or more often if necessary. A dirty filter
reduces the efficiency.
• Do not insert hands or other objects through the air inlet or outlet
while the product is operating. There are sharp and moving parts
that could cause personal injury.
• Be cautious when unpacking and installing the product. Sharp
edges could cause injury.
• If the refrigerant gas leaks during the repair, do not touch the
leakaing refrigerant gas. The refrigernat gas can cause frostbite
(cold burn).
• Do not tilt the unit when removing or uninstalling it. The
condensed water inside can spill.
• Do not mix air or gas other than the specified refrigerant used in
the system. If air enters the refrigerant system, an excessively
high pressure results, causing equipment damage or injury.
• If the refrigerant gas leaks during the installation, ventilate the
area immediately. Otherwise it can be harmfull for your health.
• Dismantling the unit, treatment of the refrigerant oil and eventual
parts should be done in accordance with local and national
standards.
1,MFL67737205,영영 2018. 6. 15. 영영 11:50 Page 7
8
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
• Replace the all batteries in the remote control with new ones of
the same type. Do not mix old and new batteries or different
types of batteries. There is risk of fire or product failure.
• Do not recharge or disassemble the batteries. Do not dispose off
batteries in a fire. They may burn or explode.
• If the liquid from the batteries gets onto your skin or clothes,
wash it well with clean water. Do not use the remote if the
batteries have leaked. The chemicals in batteries could cause
burns or other health hazards.
• If you eat the liquid from the batteries, brush your teeth and see
doctor. Do not use the remote if the batteries have leaked. The
chemicals in batteries could cause burns or other health hazards.
• Do not let the air conditioner run for a long time when the
humidity is very high and a door or a window is left open.
Moisture may condense and wet or damage furniture.
• Do not expose your skin or kids or plants to the cool or hot air
draft. This could harm to your health.
• Do not drink the water drained from the product. It is not sanitary
and could cause serious health issues.
• Use a firm stool or ladder when cleaning, maintaining or repairing
the product at an height. Be careful and avoid personal injury.
1,MFL67737205,영영 2018. 6. 15. 영영 11:50 Page 8
TABLE OF CONTENTS
ENGLISH
9
2 TIPS FOR SAVING
ENERGY
3 IMPORTANT SAFETY
INSTRUCTIONS
10 INSTALLATION
11 INSTALLATION OF
INDOOR, OUTDOOR
UNIT
11 Select the best location
12 Fixing Installation Plate
13 Piping length and elevation
14 Refrigerant charge
15 Preparing work for Installation (ART
COOL Type Only)
16 Sticking the installation guide map and
fixing Indoor unit (ART COOL Type Only)
17 Drill a hole in the wall
18 INSTALLATION OF
WIRED REMOTE
CONTROLLER
20 Wired remote controller installation
21 FLARING WORK AND
CONNECTION OF PIPING
21 Flaring work
22 Connection of piping - Indoor
24 Connection of piping - Outdoor
27 Installation
28 Installation of The Main Unit
29 CONNECTING THE CABLE
BETWEEN INDOOR UNIT
AND OUTDOOR UNIT
29 Connect the cable to the Indoor unit
31 Connect the cable to the Outdoor unit
33 Connection of Wiring
34 CHECKING THE
DRAINAGE AND FORM-
ING THE PIPINGS
34 Checking the Drainage
35 Forming the Piping
36 AIR PURGING AND
EVACUATION
36 Checking method
37 Evacuation
38 PANEL FRONT
ASSEMBLY
(ART COOL TYPE ONLY)
39 INSTALLATION PI485
40 TEST RUNNING
41 FUNCTION
41 Dip S/W Setting
42 Forced Cooling Operation
43 Wiring Error Check
43 Saving Power Consumption
44 Night Quiet Mode
45 Mode Lock
46 PCB Display(14/16/18/21k Model Only)
47 MAX COMBINATION
CAPACITY
48 INSTALLATION GUIDE AT
THE SEASIDE
49 SEASONAL WIND AND
CAUTIONS IN WINTER
TABLE OF CONTENTS
1,MFL67737205,영영 2018. 6. 15. 영영 11:50 Page 9
10
INSTALLATION
ENGLISH
Installation plate
Type "B" screws
Type "A" screw (6 EA) Type "A" screw (8 EA) Type "A" screw (7 EA)
Holder Remote Control
Type "A" screw and plastic anchors
more than
30cm
more than
30cm
Figure FigureName
Screw driver
Electric drill
Measuring tape, Knife
Hole core drill
Spanner
Torque wrench
Multi-meter
Hexagonal wrench
Ammeter
Gas-leak detector
Thermometer,
Level
Flaring tool set
Name
Installation Parts
Installation Tools
INSTALLATION
1,MFL67737205,영영 2018. 6. 15. 영영 11:50 Page 10
INSTALLATION OF INDOOR, OUTDOOR UNIT
ENGLISH
11
Read completely, then follow step by step.
You need to select adequate installation loca-
tion considering the following conditions, and
make sure to acquire the consent of the user.
Select the best location
- Do not have any heat or steam near the unit.
- Select a place where there are no obstacles
in front of the unit.
- Make sure that condensation drainage can
be conveniently routed away.
- Do not install near a doorway.
-
Ensure the spaces indicated by arrows from
the wall, ceiling, fence or other obstacles.
- Use a stud finder to locate studs to prevent
unnecessary damage to the wall.
- If an awning is built over the unit to prevent
direct sunlight or rain exposure, make sure
that heat radiation from the condenser is not
restricted.
- Ensure that the spaces indicated by arrows
around front, back and side of the unit.
- Do not place animals and plants in the path
of the warm air.
- Take the air conditioner weight into account
and select a place where noise and vibration
are minimum.
- Select a place so that the warm air and noise
from the air conditioner do not disturb neigh-
bors.
- Place that can sufficiently endure the weight
and vibration of the outdoor unit and where
even installation is possible.
-
Place that has no direct influence of snow or rain.
- Place with no danger of snowfall or icicle
drop.
- Place without weak floor or base such as
decrepit part of the building or with a lot of
snow accumulation.
If the outdoor unit is installed on a roof struc-
ture, be sure to level the unit. Ensure the roof
structure and anchoring method are adequate
for the unit location. Consult local codes
regarding rooftop mounting.
Install the indoor unit on the wall where
the height from the floors more than 2.3
meters. (ART COOL Type Only 1.5m)
CAUTION
!
More than 20cm
More than
10cm
More than 2.3m
More than
10cm
More than 20cm
More than
10cm
More than 2.3m
More than
10cm
More than 20cm
More
than 50cm
More than 1.5m
More
than 50cm
More than 20cm
More than
10cm
More than 2.3m
More than
10cm
more than
70cm
more than
30cm
more than
30cm
more than
60cm
more than 60cm
more than
70cm
more than
30cm
more than 60cm
more than
30cm
more than
60cm
Indoor unit
Outdoor unit
Rooftop Installations
INSTALLATION OF INDOOR, OUTDOOR UNIT
1,MFL67737205,영영 2018. 6. 15. 영영 11:50 Page 11
12
INSTALLATION OF INDOOR, OUTDOOR UNIT
ENGLISH
<Type 4>
Installation Plate
Type “A”
65mm
Type “A”
65mm
Chassis
Hook
Installation Plate
65mm
Chassis
Hook
Installation Plate
Type “A”
Indoor Type
Capacity
(kBtu/h)
Type
Wall mounted
/ART COOL
Mirror
7,9,12 1,3
18, 24 2,4
65mm
Installation plate
Left rear piping Right rear piping
Ø65
Ø65
105mm
105mm
65mm
55mm
45mm
140mm
Ø65
65mm65mm
65mm
45mm
Ø65
Installation plate
Left rear piping Right rear piping
65mm
(Unit : mm)
Unit
Outline
Left Rear Piping
Right Rear Piping
Place a level on raised tab
Installation plate
Ø65
Ø65
184
220
156
307
567460
Fixing Installation Plate
The wall you select should be strong and solid
enough to prevent vibration
1 Mount the installation plate on the wall
with type "A" screws. If mounting the unit
on a concrete wall, use anchor bolts.
- Mount the installation plate horizontally
by aligning the centerline using a level.
<Type 1>
2 Measure the wall and mark the centerline.
It is also important to use caution concern-
ing the location of the installation plate-
routing of the wiring to power outlets is
through the walls typically. Drilling the hole
through the wall for piping connections
must be done safely.
<Type 1>
<Type 2>
<Type 3>
<Type 2>
<Type 3>
<Type 4>
65mm
Chassis
Hook
Installation Plate
Type “A”
1,MFL67737205,영영 2018. 6. 15. 영영 11:51 Page 12
INSTALLATION OF INDOOR, OUTDOOR UNIT
ENGLISH
13
Piping length and elevation
Multiple Piping Models (Unit: m)
Distributor type Models (Unit: m)
Phase Capacity(kBtu/h) Total Length Max Length(A/B)
Max Elevation
(h1)
In - In Elevation
(h2)
14/16 30 20 15 7.5
18 50 25 15 7.5
21 50 25 15 7.5
24/27 70 25 15 7.5
30 75 25 15 7.5
40 85 25 15 7.5
Phase
Capacity
(kBtu/h)
Total
Length
Max Main Pipe
Length (A/B)
Total Branch
Pipe Length
Max Branch
Pipe Length
Max Elevation
(h1)
In - In
Elevation (h2)
40 100 50 50 15 30 15
48 135 55 80 15 30 15
56 145 55 90 15 30 15
42 125 55 70 15 30 15
48 135 55 80 15 30 15
56 145 55 90 15 30 15
h2
h1
h1
A
A
Branch Pipe
Main Pipe
Distributor
Distributor
B
B
h2
Multiple Piping Type Distributor Type
Capacity is based on standard length and maximum allowance length is on the basis of relia-
bility. If outdoor unit is at higher elevation than the indoor units, after 24m of vertical height,
1 oil trap is required.
CAUTION
!
1,MFL67737205,영영 2018. 6. 15. 영영 11:51 Page 13
14
INSTALLATION OF INDOOR, OUTDOOR UNIT
ENGLISH
Refrigerant charge
The calculation of the additional charge should be taken in account for the length of extra pipe.
Multiple Piping Models (Unit: m)
Distributor type Models (Unit: m)
• Multiple Piping Models
Additional charge (g) = ((A Room Installation Length – Standard Length ) x 20g/m
+ (B Room Installation Length – Standard Length ) x 20g/m +.. )
- CF(Correction Factor) x 150
h CF = Max. number of connectable indoor unit – Total number of connected indoor unit
• Distributor type Models
Additional charge (g) = (( Total Main piping Length - Main Standard Length ) x 50g/m
+ (A Room Branch Length – Standard Length ) x 20g/m
+ (B Room Branch Length – Standard Length ) x 20g/m
+ (C Room Branch Length – Standard Length ) x 20g/m +.. )
- CF(Correction Factor) x 100
h CF = Max. number of connectable indoor unit – Total number of connected indoor unit
Phase Capacity(kBtu/h)
Standard
Length(m)
Max Piping for
one room(m)
Max total Piping
Length
Additional
Charge(g/m)
14/16 7.5 20 30 20
18 7.5 25 50 20
21 7.5 25 50 20
24/27 7.5 25 70 20
30 7.5 25 75 20
40 7.5 25 85 20
Phase Capacity(kBtu/h)
Main Piping length Branch piping length
Standard
length(m)
Additional refrig-
erant(g/m)
Standard
length(m)
Additional refrig-
erant(g/m)
40 5 50 5 20
48 5 50 5 20
56 5 50 5 20
42 5 50 5 20
48 5 50 5 20
56 5 50 5 20
• Total main pipe(A+B+C) = 30m
• Each branch pipe
a = 10m
b = 8m
c = 5m
d = 3m
e = 10m
*Additional Charge
=((30-5) x 50 + (10-5) x 20 + (8-5) x 20
+ (5-5) x 20 + (3-5) x 20 + (10-5) x 20)
- (7-5) x 100 = 1270g
A
Ex) Distributor type Model 1Ø, 40kBtu/h
A
B
C
abc
7k 9k 9k
d
e
9k
18k
1,MFL67737205,영영 2018. 6. 15. 영영 11:51 Page 14
INSTALLATION OF INDOOR, OUTDOOR UNIT
ENGLISH
15
Preparing work for Installation (ART COOL Type Only)
1 First, push the front panel backward and lift it up to remove the two screws.
2 The moment of lifting the both lower parts of panel front, you can hear sound this panel came
out, In this time panel front is separated
3 After pull down this panel a bit, and separate connecting wire with product.
1 Remove two screws(for fixing cover pipe)
2 Pull up the cover side of desired connecting direction, then
cover side is separated.
3 In case of connecting direction is left or right, path through
the hole of cover side.
1 Remove the rubber stopple of desired direction of drainage.
2 As the following picture, Insert drain hose in the handle of
drain pan, and join drain hose and connecting hose.
Panel Front
Connector
Panel Front
Connector
After removing the pipe hole, cut the burr
for safety.
CAUTION
!
Pipe hole
rubber cap
Only one
desiring direction
Connecting
part
Adhesive
Drain
hose
NOTE
!
When connecting pipe path through rear
wall, don’t remove the hole.
Open panel front
Remove cover pipe and cover side
Drain hose junction
1,MFL67737205,영영 2018. 6. 15. 영영 11:51 Page 15
16
INSTALLATION OF INDOOR, OUTDOOR UNIT
ENGLISH
Sticking the installation guide map and fixing Indoor unit
(ART COOL Type Only)
Put an Installation Guide Map on the desired surface.
Make a hole with diameter of 6mm and depth of 30-35mm when piercing a screw point.
Drive the four plastic anchors into drilled points.
Hang the hole of product at the upper screws.
(In this time, Remove the map)
(Falling attention)
Check the fixed product with light power.
Adjust level even by level guage and fix to installation for reference on the wall.
INSTALLATION GUIDE MAP
I
N
ST
AI
IATION
G
UI
DE
M
A
P
Plastic anchors
I
N
STALLATI
ON
GU
I
D
E
M
AP
I
NSTA
LLAT
I
O
N
G
U
IDE
MA
P
Hanger hole
(Rear side of
product)
Horizontality
I
N
S
TA LL
A
TI
O
N
G
UIDE
MA
P
1,MFL67737205,영영 2018. 6. 15. 영영 11:51 Page 16
INSTALLATION OF INDOOR, OUTDOOR UNIT
ENGLISH
17
Drill the piercing part for connecting pipe as diameter Ø65mm. (In case of piercing rear surface)
First, Drive the two points of the upper parts by screws.(Leave 10mm for hanging product)
Drive the lower parts after facing the hole of product with plastic anchors, and fix completely the
upper screws.
In case of nothing wrong in the matter, connect the pipe and the wire. (Installation manual refer-
ence)
Drill a hole in the wall
Drill the piping hole with a Ø65mm hole core drill. Drill the piping hole at either the right or the
left with the hole slightly slanted to the outdoor side.
Refer to No. 5 on this page when making a hole in the wall.
10mm
INSTALLATION GU
Plastic
anchors
5-7mm
(3/16"~5/16")
Indoor
WALL
Outdoor
1,MFL67737205,영영 2018. 6. 15. 영영 11:51 Page 17
18
INSTALLATION OF WIRED REMOTE CONTROLLER
ENGLISH
1 Please fix tightly using provided screw after placing remote controller setup board on the
place where you like to setup.
- Please set it up not to bend because poor setup could take place if setup board bends.
Please set up remote controller board fit to the reclamation box if there is a reclamation box.
2 Can set up Wired remote controller cable into three directions.
- Setup direction: the surface of wall reclamation, upper, right
- If setting up remote controller cable into upper and right side, please set up after removing
remote controller cable guide groove.
h Remove guide groove with long nose.
Reclamation to the surface of the wall
Upper part guide groove
Right part guide groove
3 Please fix remote controller upper part into the
setup board attached to the surface of the wall,
as the picture below, and then, connect with
setup board by pressing lower part.
- Please connect not to make a gap at the remote
controller and setup board’s upper and lower,
right and left part.
When separating remote controller from setup
board, as the picture below, after inserting into
the lower separating hole using screw driver and
then, spinning clockwise, remote controller is
separated.
- There are two separating holes. Please individu-
ally separate one at a time.
- Please be careful not to damage the inside
components when separating.
2
2
1
3
3
<Wire guide grooves>
Wall
Side
Wall
Side
Wall
Side
Wall
Side
<Connecting order>
<Separating order>
INSTALLATION OF WIRED REMOTE CONTROLLER
1,MFL67737205,영영 2018. 6. 15. 영영 11:51 Page 18
INSTALLATION OF WIRED REMOTE CONTROLLER
ENGLISH
19
4 Please connect indoor unit and remote controller using connection cable.
5 Please use extension cable if the distance between wired remote controller and indoor unit is
more than 10m.
Please check if connector is normally connected.
Connecting cable
Indoor
Unit side
When installing the wired remote controller, do not bury it in the wall.
(It can cause damage in the temperature sensor.)
Do not install the cable to be 50m or above.
(It can cause communication error.)
• When installing the extension cable, check the connecting direction of the connector of
the remote controller side and the product side for correct installation.
• If you install the extension cable in the opposite direction, the connector will not be con-
nected.
• Specification of extension cable: 2547 1007 22# 2 core 3 shield 5 or above.
CAUTION
!
1,MFL67737205,영영 2018. 6. 15. 영영 11:51 Page 19
20
INSTALLATION OF WIRED REMOTE CONTROLLER
ENGLISH
5feet
(1.5meters)
no
no
no
yes
Fig.1 Typical locations for remote controller
Wired remote controller installation
- Since the room temperature sensor is in the remote controller, the remote controller box should
be installed in a place away from direct sunlight, high humidity and direct supply of cold air to
maintain proper space temperature. Install the remote controller about 5ft(1.5m) above the floor
in an area with good air circulation at an average temperature.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the
remote controller LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
1,MFL67737205,영영 2018. 6. 15. 영영 11:51 Page 20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51

LG A5UW40GFA0.EWGBBTK Installation guide

Category
Split-system air conditioners
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI