Huawei FusionServer Pro 2288X V5 Product White Paper

Category
Servers
Type
Product White Paper
Huawei FusionServer Pro 2288X V5 Server
V100R005
Technical White Paper
Issue 03
Date 2020-04-20
HUAWEI TECHNOLOGIES CO., LTD.
Copyright © Huawei Technologies Co., Ltd. 2020. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specied in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees
or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every eort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Huawei Technologies Co., Ltd.
Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: https://e.huawei.com
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. i
About This Document
Purpose
This document describes the 2288X V5 rack server in terms of features, structure,
specications, and component compatibility.
Intended Audience
This document is intended for:
Huawei presales engineers
Channel partner presales engineers
Enterprise presales engineers
Symbol Conventions
The symbols that may be found in this document are dened as follows.
Symbol Description
Indicates a hazard with a high level of risk which, if not
avoided, will result in death or serious injury.
Indicates a hazard with a medium level of risk which, if
not avoided, could result in death or serious injury.
Indicates a hazard with a low level of risk which, if not
avoided, could result in minor or moderate injury.
Indicates a potentially hazardous situation which, if not
avoided, could result in equipment damage, data loss,
performance deterioration, or unanticipated results.
NOTICE is used to address practices not related to
personal injury.
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper About This Document
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. ii
Symbol Description
Supplements the important information in the main
text.
NOTE is used to address information not related to
personal injury, equipment damage, and environment
deterioration.
Change History
Issue Date Description
03 2020-04-20 This issue is the third ocial release.
02 2020-03-05 The issue is the second ocial release.
01 2019-12-31 This issue is the rst ocial release.
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper About This Document
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. iii
Contents
About This Document................................................................................................................ ii
1 Overview....................................................................................................................................1
2 Features..................................................................................................................................... 2
3 Physical Structure....................................................................................................................5
4 Logical Structure......................................................................................................................7
5 Hardware Description.............................................................................................................9
5.1 Front Panel................................................................................................................................................................................ 9
5.1.1 Appearance............................................................................................................................................................................ 9
5.1.2 Indicators and Buttons.....................................................................................................................................................11
5.1.3 Ports....................................................................................................................................................................................... 15
5.2 Rear Panel............................................................................................................................................................................... 17
5.2.1 Appearance.......................................................................................................................................................................... 17
5.2.2 Indicators.............................................................................................................................................................................. 18
5.2.3 Ports....................................................................................................................................................................................... 19
5.3 Processor.................................................................................................................................................................................. 21
5.4 Memory.................................................................................................................................................................................... 22
5.4.1 Memory Identier............................................................................................................................................................. 22
5.4.2 Memory Subsystem Architecture................................................................................................................................. 23
5.4.3 Memory Compatibility..................................................................................................................................................... 24
5.4.4 Memory Installation Guidelines................................................................................................................................... 27
5.4.5 Memory Installation Positions...................................................................................................................................... 27
5.4.6 Memory Protection Technologies................................................................................................................................ 29
5.5 Storage..................................................................................................................................................................................... 29
5.5.1 Drive Congurations.........................................................................................................................................................30
5.5.2 Drive Numbering............................................................................................................................................................... 33
5.5.3 Drive Indicators.................................................................................................................................................................. 35
5.5.4 RAID Controller Card........................................................................................................................................................37
5.6 Network................................................................................................................................................................................... 37
5.6.1 LOMs......................................................................................................................................................................................37
5.6.2 OCP 2.0 Mezzanine Cards...............................................................................................................................................40
5.7 I/O Expansion......................................................................................................................................................................... 41
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper Contents
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. iv
5.7.1 PCIe Cards............................................................................................................................................................................ 41
5.7.2 PCIe Slots..............................................................................................................................................................................41
5.7.3 PCIe Slot Description........................................................................................................................................................ 46
5.8 PSUs...........................................................................................................................................................................................50
5.9 Fans............................................................................................................................................................................................51
5.10 Boards.....................................................................................................................................................................................51
5.10.1 Mainboard......................................................................................................................................................................... 52
5.10.2 Drive Backplane............................................................................................................................................................... 54
6 Product Specications.......................................................................................................... 60
6.1 Technical Specications...................................................................................................................................................... 60
6.2 Environmental Specications............................................................................................................................................64
6.3 Physical Specications.........................................................................................................................................................65
7 Software and Hardware Compatibility............................................................................ 67
8 Safety Instructions................................................................................................................ 68
8.1 Safety Instructions................................................................................................................................................................ 68
8.2 Maintenance and Warranty.............................................................................................................................................. 71
9 System Management............................................................................................................72
10 Certications........................................................................................................................ 74
A Appendix................................................................................................................................. 75
A.1 Product SN.............................................................................................................................................................................. 75
A.2 Operating Temperature Limitations ............................................................................................................................. 77
A.3 RAS Features.......................................................................................................................................................................... 79
A.4 Sensor List............................................................................................................................................................................... 81
B Glossary................................................................................................................................... 88
B.1 A-E............................................................................................................................................................................................. 88
B.2 F-J............................................................................................................................................................................................... 89
B.3 K-O.............................................................................................................................................................................................89
B.4 P-T.............................................................................................................................................................................................. 89
B.5 U-Z............................................................................................................................................................................................. 90
C Acronyms and Abbreviations..............................................................................................91
C.1 A-E............................................................................................................................................................................................. 91
C.2 F-J............................................................................................................................................................................................... 92
C.3 K-O.............................................................................................................................................................................................93
C.4 P-T.............................................................................................................................................................................................. 94
C.5 U-Z............................................................................................................................................................................................. 96
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper Contents
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. v
1 Overview
Huawei FusionServer Pro 2288X V5 (marked as H22X-05 on the nameplate, 2288X
V5 for short) is a new-generation 2U 2-socket rack server designed for Internet,
Internet Data Center (IDC), cloud computing, enterprise, and telecom applications.
The 2288X V5 is ideal for IT core services, cloud computing, high-performance
computing, distributed storage, big data processing, enterprise or telecom
applications, and other complex workloads.
The reliable 2288X V5 features low power consumption, high scalability, easy
deployment, and simplied management.
Figure 1-1 Physical structure of a 2288X V5 with 12 x 3.5" drives (example)
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper 1 Overview
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. 1
2 Features
Performance and Scalability
Powered by two Intel® Xeon® Scalable Skylake or Cascade Lake processors, the
server provides up to 28 cores, 3.8 GHz frequency, a 38.5 MB L3 cache, and
two 10.4 GT/s UPI links between the processors, which deliver supreme
processing performance.
It supports up to two processors with 56 cores and 112 threads to
maximize the concurrent execution of multithreaded applications.
An L2 cache is added. Each core can exclusively use 1 MB of L2 cache and
at least 1.375 MB of L3 cache.
Intel Turbo Boost Technology 2.0 allows processor cores to run faster
than the frequency specied in the Thermal Design Power (TDP)
conguration if they are operating below power, current, and
temperature specication limits.
Intel Hyper-Threading Technology enables each processor core to run up
to two threads, improving parallel computation capability.
The hardware-assisted Intel® Virtualization Technology (Intel® VT) allows
operating system (OS) vendors to better use hardware to address
virtualization workloads.
Intel® Advanced Vector Extensions 512 (Intel AVX-512) signicantly
accelerates oating-point performance for computing-intensive
applications.
The Cascade Lake processors support Intel® Deep Learning Boost vector
neural network instructions (VNNI) to improve the performance of deep
learning applications.
The server supports double data rate 4 (DDR4) registered dual in-line
memory modules (RDIMMs) and load-reduced DIMMs (LRDIMMs) with error
checking and correcting (ECC). A server fully congured with twenty-four
2933 MT/s memory modules (only available with Cascade Lake processors)
provides 3072 GB memory space and the maximum theoretical memory
bandwidth of 249.9375 GB/s.
Flexible drive congurations cater to a variety of business requirements and
ensure high elasticity and scalability of storage resources.
The use of all solid-state drives (SSDs) is supported. An SSD supports up to
100 times more I/O operations per second (IOPS) than a typical hard disk
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper 2 Features
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. 2
drive (HDD). The use of all SSDs provides higher I/O performance than the
use of all HDDs or a combination of HDDs and SSDs.
The LANs on motherboard (LOMs) and Open Compute Project (OCP) 2.0
mezzanine cards provide a variety of ports to meet dierent networking
requirements.
With Intel integrated I/O, the Intel® Xeon® Scalable processors integrate the
PCIe 3.0 controller to shortens I/O latency and improve overall system
performance.
The server supports up to eight PCIe 3.0 slots.
Availability and Serviceability
Carrier-class components with process expertise ensure high system reliability
and availability.
The server uses hot-swappable SAS/SATA/NVMe drives. It supports RAID 0, 1,
1E, 10, 5, 50, 6, and 60, depending on the RAID controller card used. It also
uses a supercapacitor to protect the RAID cache data against power failures.
The SSDs oer better reliability than HDDs, ensuring continued system
performance.
The server provides simplied O&M and ecient troubleshooting through the
UID/HLY indicators on the front panel, fault diagnosis LED, and iBMC web
interface.
The built-in iBMC monitors system parameters in real time, triggers alarms,
and performs recovery actions to minimize the system downtime.
Huawei provides a three-year warranty for parts replacement and onsite
repair for the servers used in China. Huawei provides a 10-hour-a-day, 7-day-
a-week support program. Service requests will be handled the next business
day. Optional service upgrades are available.
Huawei provides a three-year warranty for parts replacement and repair for
the servers used outside China. Huawei provides a 9-hour-a-day, 5-day-a-
week support program. Service requests will be handled the next business day.
Huawei delivers the repaired or new parts within 45 calendar days after
receiving the defective parts.
Manageability and Security
The built-in iBMC monitors server operating status and provides remote
management.
A password is required for accessing the BIOS, ensuring system boot and
management security.
The Network Controller Sideband Interface (NC-SI) allows a network port to
serve as a management port and a service port for maximized return on
investment (ROI) for customers. The NC-SI feature is disabled by default and
can be enabled through the iBMC or BIOS.
The integrated Unied Extensible Firmware Interface (UEFI) improves setup,
conguration, and update eciency and simplies fault handling.
Lockable server chassis panel ensures security of local data.
The Advanced Encryption Standard–New Instruction (AES NI) algorithm
allows faster and stronger encryption.
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper 2 Features
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. 3
Intel Execute Disable Bit (EDB) function prevents certain types of malicious
buer overow attacks when working with a supported OS.
Intel Trusted Execution Technology enhances security using hardware-based
defense against malicious software attacks, allowing applications to run
independently.
The trusted platform module (TPM) and trusted cryptography module (TCM)
provide advanced encryption functions, such as digital signatures and remote
authentication.
The service port with NC-SI enabled supports the following conguration:
Conguring any port on the LOM, OCP 2.0 mezzanine card 1, or PCIe NIC as the service
port with NC-SI enabled. Host port 1 is congured by default.
Enabling, disabling, and setting a virtual local area network (VLAN) ID for this port. The
VLAN ID is 0 and disabled by default.
Conguring IPv4 addresses (IPv4 address, subnet mask, and gateway) and IPv6
addresses (IPv6 address, prex length, and gateway) for this port.
Energy Eciency
The 80 Plus Platinum power supply units (PSUs) of multiple power ratings
provide 94% power eciency at 50% load.
The server supports active/standby power supplies and high-voltage DC
(HVDC) for improved power supply eciency.
Ecient voltage regulator-down (VRD) power supplies for boards minimize
the energy loss from DC/DC power conversion.
Area-based, Proportional-Integral-Derivative (PID) intelligent fan speed
adjustment and intelligent CPU frequency scaling optimize heat dissipation
and reduce overall system power consumption.
The improved thermal design with energy-ecient fans ensures optimal heat
dissipation and reduces system power consumption.
The server is protected with power capping and power control measures.
Staggered spin-up for drives reduces the server boot power consumption.
Intel® Intelligent Power Capability allows a processor to be powered on or o
based on requirements.
Low-voltage Intel® Xeon® Scalable processors consume less energy, ideally
suited for data centers and telecommunications environments constrained by
power and thermal limitations.
SSDs consume 80% less power than HDDs.
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper 2 Features
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. 4
3 Physical Structure
Figure 3-1 Physical structure of a 2288X V5 with 12 x 3.5" drives (example)
1 I/O module 1 2 I/O module 2
3 PSUs 4 Chassis
5 I/O module 3 6 Supercapacitor holders
7 Air duct 8 Front-drive backplane
9 Fan module brackets 10 Fan modules
11 Front drives 12 Heat sinks
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper 3 Physical Structure
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. 5
13 Memory modules 14 Processors
15 Cable organizers 16 TPM/TCM
17 Mainboard 18 Screw-in RAID controller
card
19 OCP 2.0 mezzanine cards - -
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper 3 Physical Structure
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. 6
4 Logical Structure
Figure 4-1 2288X V5 logical structure
The server supports one or two Intel® Xeon® Scalable processors.
The server supports up to 24 memory modules.
The CPUs (processors) interconnect with each other through two UPI links at
a speed of up to 10.4 GT/s.
Three PCIe riser cards connect to the processors through PCIe buses to provide
ease of expandability and connection.
CPUs 1 and 2 each support one OCP 2.0 mezzanine card.
The RAID controller card on the mainboard connects to CPU 1 through PCIe
buses, and connects to the drive backplane through SAS signal cables. A
variety of drive backplanes are provided to support dierent local storage
congurations.
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper 4 Logical Structure
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. 7
The LBG-2 Platform Controller Hub (PCH) supports two 10GE optical LOM
ports.
The server uses Hi1710 management chip and supports a video graphic array
(VGA) port, a management network port, and a debug serial port.
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper 4 Logical Structure
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. 8
5 Hardware Description
5.1 Front Panel
5.2 Rear Panel
5.3 Processor
5.4 Memory
5.5 Storage
5.6 Network
5.7 I/O Expansion
5.8 PSUs
5.9 Fans
5.10 Boards
5.1 Front Panel
5.1.1 Appearance
8 x 2.5" drive conguration
Figure 5-1 Front view
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper 5 Hardware Description
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. 9
1 Drives 2 (Optional) Built-in DVD
drive
3 Slide-out label plate
(with an SN label)
- -
12 x 3.5" drive conguration
Figure 5-2 Front view
1 Drives 2 Slide-out label plate
(with an SN label)
24 x 2.5" drive conguration
Figure 5-3 Front view
1Drives 2 Slide-out label plate
(with an SN label)
25 x 2.5" drive conguration
Figure 5-4 Front view
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper 5 Hardware Description
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. 10
1 Drives 2 Slide-out label plate
(with an SN label)
5.1.2 Indicators and Buttons
Positions
8 x 2.5" drive conguration
Figure 5-5 Indicators and buttons on the front panel
1 10GE LOM port 1
connection status
indicator
2 10GE LOM port 2
connection status
indicator
3 GE LOM port connection
status indicator
NOTE
The indicator is reserved.
4 Non-Maskable Interrupt
(NMI) button
5 Fault diagnosis LED 6 Health status indicator
7 UID button/indicator 8 Power button/indicator
12 x 3.5" drive conguration
Figure 5-6 Indicators and buttons on the front panel
110GE LOM port 1
connection status
indicator
2 10GE LOM port 2
connection status
indicator
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper 5 Hardware Description
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. 11
3 GE LOM port connection
status indicator
NOTE
The indicator is reserved.
4 Fault diagnosis LED
5 Health status indicator 6 UID button/indicator
7 Power button/indicator - -
24 x 2.5" drive conguration
Figure 5-7 Indicators and buttons on the front panel
1 10GE LOM port 1
connection status
indicator
2 10GE LOM port 2
connection status
indicator
3 GE LOM port connection
status indicator
NOTE
The indicator is reserved.
4 Fault diagnosis LED
5 Health status indicator 6 UID button/indicator
7 Power button/indicator 8 NMI button
25 x 2.5" drive conguration
Figure 5-8 Indicators and buttons on the front panel
110GE LOM port 1
connection status
indicator
2 10GE LOM port 2
connection status
indicator
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper 5 Hardware Description
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. 12
3 GE LOM port connection
status indicator
NOTE
The indicator is reserved.
4 Fault diagnosis LED
5 Health status indicator 6 UID button/indicator
7 Power button/indicator - -
Indicator and Button Description
Table 5-1 Indicators and buttons on the front panel
Silkscreen Indicator/
Button
Description
Fault
diagnosis LED
---: The device is operating normally.
Fault code: A component is faulty.
For details about error codes, see
FusionServer Pro Rack Server iBMC Alarm
Handling.
Power
button/
indicator
Power indicator:
O: The device is not powered on.
Steady green: The device is powered on.
Blinking yellow: The power button is locked.
The power button is locked when the iBMC
is starting.
Steady yellow: The device is ready to power
on.
Power button:
When the device is powered on, you can
press this button to gracefully shut down
the OS.
When the device is powered on, holding
down this button for 6 seconds will forcibly
power o the device.
When the power indicator is steady green,
you can press this button to power on the
device.
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper 5 Hardware Description
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. 13
Silkscreen Indicator/
Button
Description
UID button/
indicator
The UID button/indicator helps identify and
locate a device.
UID indicator:
O: The device is not being located.
Blinking blue: The device has been located
and is distinguished from other devices that
have also been located.
Steady blue: The device is being located.
UID button:
You can turn on or o the UID indicator by
pressing the UID button on the panel or by
using the iBMC CLI or WebUI.
You can press this button to turn on or o
the UID indicator.
You can press and hold down this button for
4 to 6 seconds to reset the iBMC.
Health status
indicator
O: The device is powered o or is faulty.
Blinking red at 1 Hz: A major alarm has
been generated on the system.
Blinking red at 5 Hz: A critical alarm has
been generated on the system.
Steady green: The device is operating
properly.
NMI button A non-maskable interrupt (NMI) is generally
triggered to stop the OS for debugging. To
trigger an NMI, press this button or click the
button on the iBMC WebUI.
NOTICE
Press the NMI button only when the OS is
abnormal. Do not press this button when the
server is operating properly. An NMI does not
gracefully shut down the OS and causes service
interruption and data loss.
Before pressing the NMI button, ensure that the
OS has the NMI processing program. Otherwise,
the OS may crash. Exercise caution when pressing
this button.
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper 5 Hardware Description
Issue 03 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. 14
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102

Huawei FusionServer Pro 2288X V5 Product White Paper

Category
Servers
Type
Product White Paper

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI