Huawei FusionServer Pro CH242 V5 Technical White Paper

Type
Technical White Paper
Huawei FusionServer Pro CH242 V5 Compute
Node
V100R005
Technical White Paper
Issue 07
Date 2020-07-31
HUAWEI TECHNOLOGIES CO., LTD.
Copyright © Huawei Technologies Co., Ltd. 2020. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specied in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees
or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every eort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Huawei Technologies Co., Ltd.
Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: https://e.huawei.com
Issue 07 (2020-07-31) Copyright © Huawei Technologies Co., Ltd. i
About This Document
Overview
This document describes the appearance, features, specications, and
congurations of the new-generation CH242 V5 compute node of the Huawei
E9000 blade server.
Intended Audience
This document is intended for:
Huawei presales engineers
Channel partner presales engineers
Enterprise presales engineers
Symbol Conventions
The symbols that may be found in this document are dened as follows.
Symbol Description
Indicates a hazard with a high level of risk which, if not
avoided, will result in death or serious injury.
Indicates a hazard with a medium level of risk which, if
not avoided, could result in death or serious injury.
Indicates a hazard with a low level of risk which, if not
avoided, could result in minor or moderate injury.
Indicates a potentially hazardous situation which, if not
avoided, could result in equipment damage, data loss,
performance deterioration, or unanticipated results.
NOTICE is used to address practices not related to
personal injury.
Huawei FusionServer Pro CH242 V5 Compute Node
Technical White Paper About This Document
Issue 07 (2020-07-31) Copyright © Huawei Technologies Co., Ltd. ii
Symbol Description
Supplements the important information in the main
text.
NOTE is used to address information not related to
personal injury, equipment damage, and environment
deterioration.
Change History
Issue Date Description
07 2020-07-31 This issue is the seventh ocial release.
06 2020-06-05 This issue is the sixth ocial release.
05 2020-04-20 This issue is the fth ocial release.
04 2019-08-10 Added the support for Cascade Lake
processors.
03 2018-12-04 Modied the physical structure.
02 2018-11-28 Modied the appearance.
Modied the physical structure.
Modied the logical structure.
Modied technical specications.
01 2018-03-14 This issue is the rst ocial release.
Huawei FusionServer Pro CH242 V5 Compute Node
Technical White Paper About This Document
Issue 07 (2020-07-31) Copyright © Huawei Technologies Co., Ltd. iii
Contents
About This Document................................................................................................................ ii
1 Overview....................................................................................................................................1
2 Features..................................................................................................................................... 2
3 Physical Structure....................................................................................................................5
4 Logical Structure......................................................................................................................7
5 Hardware Description.............................................................................................................9
5.1 Front Panel................................................................................................................................................................................ 9
5.1.1 Appearance............................................................................................................................................................................ 9
5.1.2 Indicators and Buttons.....................................................................................................................................................10
5.1.3 Ports....................................................................................................................................................................................... 12
5.1.4 Installation Positions........................................................................................................................................................ 12
5.2 Processor.................................................................................................................................................................................. 13
5.3 Memory.................................................................................................................................................................................... 14
5.3.1 Memory Identier............................................................................................................................................................. 14
5.3.2 Memory Subsystem Architecture................................................................................................................................. 15
5.3.3 Memory Compatibility..................................................................................................................................................... 17
5.3.4 Memory Installation Guidelines................................................................................................................................... 19
5.3.5 Memory Installation Positions...................................................................................................................................... 20
5.3.6 Memory Protection Technologies................................................................................................................................ 21
5.4 Storage..................................................................................................................................................................................... 22
5.4.1 Drive Congurations.........................................................................................................................................................22
5.4.2 Drive Numbering............................................................................................................................................................... 22
5.4.3 Drive Indicators.................................................................................................................................................................. 23
5.4.4 RAID Controller Card........................................................................................................................................................25
5.5 Network................................................................................................................................................................................... 25
5.5.1 LOMs......................................................................................................................................................................................26
5.6 I/O Expansion......................................................................................................................................................................... 27
5.6.1 PCIe Cards............................................................................................................................................................................ 27
5.6.2 PCIe Slot Description........................................................................................................................................................ 27
5.7 Boards....................................................................................................................................................................................... 29
5.7.1 Mainboard............................................................................................................................................................................29
Huawei FusionServer Pro CH242 V5 Compute Node
Technical White Paper Contents
Issue 07 (2020-07-31) Copyright © Huawei Technologies Co., Ltd. iv
6 Product Specications.......................................................................................................... 31
6.1 Technical Specications...................................................................................................................................................... 31
6.2 Environment specications................................................................................................................................................ 34
6.3 Physical Specications.........................................................................................................................................................35
7 Software and Hardware Compatibility............................................................................ 36
8 Safety Instructions................................................................................................................ 37
8.1 Safety Instructions................................................................................................................................................................ 37
8.2 Maintenance and Warranty.............................................................................................................................................. 40
9 System Management............................................................................................................41
10 Certications........................................................................................................................ 43
A Appendix................................................................................................................................. 45
A.1 Product SN.............................................................................................................................................................................. 45
A.2 RAS Features.......................................................................................................................................................................... 46
B Glossary................................................................................................................................... 49
B.1 A-E............................................................................................................................................................................................. 49
B.2 F-J............................................................................................................................................................................................... 50
B.3 K-O.............................................................................................................................................................................................50
B.4 P-T.............................................................................................................................................................................................. 50
B.5 U-Z............................................................................................................................................................................................. 51
C Acronyms and Abbreviations..............................................................................................52
C.1 A-E............................................................................................................................................................................................. 52
C.2 F-J............................................................................................................................................................................................... 53
C.3 K-O.............................................................................................................................................................................................54
C.4 P-T.............................................................................................................................................................................................. 55
C.5 U-Z............................................................................................................................................................................................. 57
Huawei FusionServer Pro CH242 V5 Compute Node
Technical White Paper Contents
Issue 07 (2020-07-31) Copyright © Huawei Technologies Co., Ltd. v
1 Overview
The CH242 V5 is a full-width compute node powered by Intel® Xeon® Scalable
processors. It provides a unique blend of supreme computing power, large
memory, and high exibility and expandability.
The CH242 V5 provides dense computing capability and an ultra-large memory. It
is optimized for virtualization, cloud computing, high-performance computing, and
compute-intensive enterprise applications.
The CH242 V5 compute nodes are installed in an E9000 chassis and are centrally
managed by the management module.
Figure 1-1 CH242 V5
Huawei FusionServer Pro CH242 V5 Compute Node
Technical White Paper 1 Overview
Issue 07 (2020-07-31) Copyright © Huawei Technologies Co., Ltd. 1
2 Features
Performance and Scalability
Powered by Intel® Xeon® Scalable Skylake or Cascade Lake processors, the
server provides up to 28 cores, 3.8 GHz frequency, a 38.5 MB L3 cache, and
three 10.4 GT/s UPI links between the processors, which deliver supreme
processing performance.
It supports four processors with 112 cores and 224 threads to maximize
the concurrent execution of multithreaded applications.
Intel Turbo Boost Technology 2.0 allows processor cores to run faster
than the frequency specied in the Thermal Design Power (TDP)
conguration if they are operating below power, current, and
temperature specication limits.
Intel Hyper-Threading Technology enables each processor core to run up
to two threads, improving parallel computation capability.
The hardware-assisted Intel® Virtualization Technology (Intel® VT) allows
operating system (OS) vendors to better use hardware to address
virtualization workloads.
Intel® Advanced Vector Extensions 512 (Intel AVX-512) signicantly
accelerates oating-point performance for computing-intensive
applications.
The Cascade Lake processors support Intel® Deep Learning Boost vector
neural network instructions (VNNI) to improve the performance of deep
learning applications.
The CH242 V5 fully congured with 48 LRDIMMs provides supreme speed,
high availability, and a maximum memory capacity of 6 TB.
The maximum theoretical memory bandwidth is 550 GB/s (64 bit/8 x 2933
MHz x 6 channels x 4), which is 83.3% higher than that of the previous-
generation platform.
The use of all solid-state drives (SSDs) is supported. An SSD supports up to
100 times more I/O operations per second (IOPS) than a typical hard disk
drive (HDD). The use of all SSDs provides higher I/O performance than the
use of all HDDs or a combination of HDDs and SSDs.
The compute node supports 192-lane PCIe 3.0 (8 GT/s per lane) to provide
20% higher I/O bandwidth than the previous 160-lane PCIe.
Huawei FusionServer Pro CH242 V5 Compute Node
Technical White Paper 2 Features
Issue 07 (2020-07-31) Copyright © Huawei Technologies Co., Ltd. 2
With Intel integrated I/O, the Intel® Xeon® Scalable processors integrate the
PCIe 3.0 controller to shortens I/O latency and improve overall system
performance.
The compute node supports mezzanine cards with a variety of network ports
to meet requirements for exible networking.
The compute node supports standard PCIe SSD cards.
The compute node supports LOM that provides two 10GE ports.
Availability and Serviceability
Memory mirroring and memory module backup prevent system shutdown
caused by uncorrectable memory errors.
Data is protected using hot-swappable drives and RAID properties.
The server provides simplied O&M and ecient troubleshooting through the
UID/HLY indicators on the front panel, fault diagnosis LED, and iBMC web
interface.
The SSDs oer better reliability than HDDs, ensuring continued system
performance.
The built-in iBMC monitors system parameters in real time, triggers alarms,
and performs recovery actions to minimize the system downtime.
Huawei provides a three-year warranty for parts replacement and onsite
repair for the servers used in China. Huawei provides a 10-hour-a-day, 7-day-
a-week support program. Service requests will be handled the next business
day. Optional service upgrades are available.
Huawei provides a three-year warranty for parts replacement and repair for
the servers used outside China. Huawei provides a 9-hour-a-day, 5-day-a-
week support program. Service requests will be handled the next business day.
Huawei delivers the repaired or new parts within 45 calendar days after
receiving the defective parts.
Manageability and Security
The built-in iBMC monitors server operating status and provides remote
management.
The integrated Unied Extensible Firmware Interface (UEFI) improves setup,
conguration, and update eciency and simplies fault handling.
The Advanced Encryption Standard–New Instruction (AES NI) algorithm
allows faster and stronger encryption.
Intel Execute Disable Bit (EDB) function prevents certain types of malicious
buer overow attacks when working with a supported OS.
Intel Trusted Execution Technology enhances security using hardware-based
defense against malicious software attacks, allowing applications to run
independently.
The trusted platform module (TPM) 2.0 provides advanced encryption
functions, such as digital signatures and remote authentication.
Energy Eciency
The Intel® Xeon® Scalable processors outperform the previous-generation
processors while tting into the same TDP.
Huawei FusionServer Pro CH242 V5 Compute Node
Technical White Paper 2 Features
Issue 07 (2020-07-31) Copyright © Huawei Technologies Co., Ltd. 3
Intel® Intelligent Power Capability allows a processor to be powered on or o
based on requirements.
Low-voltage Intel® Xeon® Scalable processors consume less energy, ideally
suited for data centers and telecommunications environments constrained by
power and thermal limitations.
The 1.2 V DDR4 RDIMMs consume 20% to 30% less power than 1.35 V DDR3
RDIMMs.
SSDs consume 80% less power than HDDs.
The hexagonal ventilation holes on the compute node provide higher
ventilation density than round holes, increasing system cooling eciency.
Ecient voltage regulator-down (VRD) power supplies for boards minimize
the energy loss from DC/DC power conversion.
The server is protected with power capping and power control measures.
Huawei FusionServer Pro CH242 V5 Compute Node
Technical White Paper 2 Features
Issue 07 (2020-07-31) Copyright © Huawei Technologies Co., Ltd. 4
3 Physical Structure
Figure 3-1 CH242 V5 physical structure
1 (Optional) HHHL PCIe
riser module
2 (Optional) HHHL PCIe
card
3 (Optional) M.2 SSDs 4 (Optional) USB ash drive
5 (Optional) TPM 6 Screw-in RAID controller
card
7 (Optional) Supercapacitor 8 Heat sinks
9(Optional) M.2 FRUsb10 (Optional) M.2 adapterb
Huawei FusionServer Pro CH242 V5 Compute Node
Technical White Paper 3 Physical Structure
Issue 07 (2020-07-31) Copyright © Huawei Technologies Co., Ltd. 5
11 Drivesa12 Drive cage
13 BIOS battery 14 Processors
15 Mezzanine cards 16 Mainboard
17 DIMMs - -
a: The drive slots support 2.5-inch SAS/SATA/NVMe drives and M.2 modules
and mixed conguration of them.
b: An M.2 module is a 2.5-inch drive module that consists of one M.2 adapter
and two M.2 FRUs.
Huawei FusionServer Pro CH242 V5 Compute Node
Technical White Paper 3 Physical Structure
Issue 07 (2020-07-31) Copyright © Huawei Technologies Co., Ltd. 6
4 Logical Structure
Figure 4-1 CH242 V5 logical structure
The server supports two or four Intel® Xeon® Scalable processors.
The server supports up to 48 memory modules.
The CPUs (processors) interconnect with each other through three UPI links at
a speed of up to 10.4 GT/s.
The mezzanine cards connect to the processors through PCIe buses to provide
service ports.
The Platform Controller Hub (PCH) has a built-in MAC chip and provides two
10 Gbit/s ports.
The storage module, consisting of a RAID controller card and a drive
backplane, connects to the CPUs through PCIe buses.
Huawei FusionServer Pro CH242 V5 Compute Node
Technical White Paper 4 Logical Structure
Issue 07 (2020-07-31) Copyright © Huawei Technologies Co., Ltd. 7
The BMC provides device management functions, such as compute node
power control, slot number acquisition, PSU detection, and KVM over IP.
Huawei FusionServer Pro CH242 V5 Compute Node
Technical White Paper 4 Logical Structure
Issue 07 (2020-07-31) Copyright © Huawei Technologies Co., Ltd. 8
5 Hardware Description
5.1 Front Panel
5.2 Processor
5.3 Memory
5.4 Storage
5.5 Network
5.6 I/O Expansion
5.7 Boards
5.1 Front Panel
5.1.1 Appearance
Figure 5-1 Front view
1Slide-out label plate (with an
SN label)
2 Ejector levers
3 Ejector release buttons 4 2.5" drivesa
5 Model 6 M.2 FRU
7 M.2 adapter 8 M.2 moduleb
Huawei FusionServer Pro CH242 V5 Compute Node
Technical White Paper 5 Hardware Description
Issue 07 (2020-07-31) Copyright © Huawei Technologies Co., Ltd. 9
9 PCIe panel - -
a: The drive slots support 2.5-inch SAS/SATA/NVMe drives and M.2 modules
and mixed conguration of them.
b: An M.2 module is a 2.5-inch drive module that consists of one M.2 adapter
and two M.2 FRUs.
5.1.2 Indicators and Buttons
Positions
Figure 5-2 Indicators and buttons on the front panel
1 Power button/indicator 2 UID button/indicator
3 Health status indicator - -
Huawei FusionServer Pro CH242 V5 Compute Node
Technical White Paper 5 Hardware Description
Issue 07 (2020-07-31) Copyright © Huawei Technologies Co., Ltd. 10
Indicator and Button Description
Table 5-1 Indicators and buttons on the front panel
Silkscreen Indicator/
Button
Description
Power
button/
indicator
Power indicator:
O: The device is not powered on.
Steady green: The device is powered on.
Blinking yellow: The power button is locked.
The power button is locked when the iBMC
is starting.
Steady yellow: The device is ready to power
on.
Power button:
When the device is powered on, you can
press this button to gracefully shut down
the OS.
When the device is powered on, holding
down this button for 6 seconds will forcibly
power o the device.
When the power indicator is steady green,
you can press this button to power on the
device.
UID UID button/
indicator
The UID button/indicator helps identify and
locate a device.
UID indicator:
O: The device is not being located.
Blinking blue: The device has been located
and is distinguished from other devices that
have also been located.
Steady blue: The device is being located.
UID button:
You can turn on or o the UID indicator by
pressing the UID button or by using the
iBMC or MM910 CLI or WebUI.
You can press this button to turn on or o
the UID indicator.
You can press and hold down this button for
4 to 6 seconds to reset the iBMC.
Huawei FusionServer Pro CH242 V5 Compute Node
Technical White Paper 5 Hardware Description
Issue 07 (2020-07-31) Copyright © Huawei Technologies Co., Ltd. 11
Silkscreen Indicator/
Button
Description
HLY Health status
indicator
O: The device is powered o or is faulty.
Blinking red at 1 Hz: A major alarm has
been generated for the device.
Blinking red at 5 Hz: A critical alarm has
been generated for the device, or the device
is not securely installed.
Steady green: The device is operating
properly.
5.1.3 Ports
Port Positions
Figure 5-3 Ports on the front panel
1 USB port 2 -
Port Description
Port Type Quantity Description
USB port USB 3.0 2 Used to connect to a USB
device.
NOTICE
Before connecting an external
USB device, check that the USB
device functions properly. The
server may operate abnormally if
an abnormal USB device is
connected.
5.1.4 Installation Positions
The CH242 V5 is installed in a full-width slot in the front of the E9000 chassis. An
E9000 chassis can house a maximum of eight CH242 V5 compute nodes.
Huawei FusionServer Pro CH242 V5 Compute Node
Technical White Paper 5 Hardware Description
Issue 07 (2020-07-31) Copyright © Huawei Technologies Co., Ltd. 12
Figure 5-4 Installation positions
5.2 Processor
The server supports two or four processors.
If two processors are required, install them in sockets CPU1 and CPU2.
The same model of processors must be used in a server.
Contact your local Huawei sales representative or use the Intelligent
Computing Compatibility Checker to determine the components to be used.
Huawei FusionServer Pro CH242 V5 Compute Node
Technical White Paper 5 Hardware Description
Issue 07 (2020-07-31) Copyright © Huawei Technologies Co., Ltd. 13
Figure 5-5 Processor positions
5.3 Memory
5.3.1 Memory Identier
You can determine the memory module properties based on the label attached to
the memory module.
Figure 5-6 Memory identier
Huawei FusionServer Pro CH242 V5 Compute Node
Technical White Paper 5 Hardware Description
Issue 07 (2020-07-31) Copyright © Huawei Technologies Co., Ltd. 14
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63

Huawei FusionServer Pro CH242 V5 Technical White Paper

Type
Technical White Paper

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI