  • Hello! I am an AI chatbot trained to assist you with the Kohler K-5452-ET-96 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Features
Washout urinal.
3/4" top spud.
1-pint or 0.125 gpf ( 0.47 lpf).
Includes inlet and outlet spuds and hangers.
Includes anti-backsplash wall.
14-3/4" (375 mm) extended rim.
Material
Vitreous china.
Water Conservation & Rebates
WaterSense
®
compliant when used with WaterSense
flushometer.
Components
Additional included component/s: 3/4" Inlet Spud, 2" Outlet Spud,
and Hanger (1 required).
Codes/Standards
ASME A112.19.2/CSA B45.1
DOE - Energy Policy Act 1992
EPA WaterSense
®
California Energy Commission (CEC)
ADA
ICC/ANSI A117.1
KOHLER
®
One-Year Limited Warranty
See website for detailed warranty information.
Available Color/Finishes
Color tiles intended for reference only.
DescriptionCodeColor
White0
Biscuit96
Almond47
Black Black7
1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to www.kohler.com.
9-28-2018 12:28
Dexter
1-Pint Urinal
K-5452-ET
2-3/8"
(60 mm)
Outlet Detail
6" (152 mm)
2" NPT
Tap
1/4"
(6 mm)
24" (610 mm)
Standard
Installation
17" (432 mm)
ADA Installation
13-3/4" (349 mm)
30"
(762 mm)
To Floor
for Regular
Installation
For Retrofit
Installation
3/4" Spud
2" NPT
Tap
6-1/2"
(165 mm)
32-1/2"
(832 mm)
To Floor for
Retrofit
Installation
11-3/4"
(298 mm)
14-3/4" (375 mm)
17-1/2" (445 mm)
Standard
Installation
9-1/2" (241 mm)
ADA Installation
20-3/4"
(527 mm)
Floor
Notes
Technical Information
Designed only for use with a 0.125 gpf (0.5 lpf)
flushometer.
All product dimensions are nominal.
WashoutFlush outlet
technology:
Install this product according to the installation
instructions.
3/4", Inlet, TopSpud size:
ADA compliant when installed to the specific
requirements of these regulations.
0.125 gal (0.5 L)Min. Water per Flush:
0.125 gal (0.5 L)Max. Water per Flush:
Designed for the above water use when installed with a
water-saving flushometer.
Pressure and Supply Requirements
25 psi (172.4 kPa)Fixture pressure min
(static):
80 psi (551.6 kPa)Fixture pressure max
(static):
1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to www.kohler.com.
9-28-2018 12:28
Dexter
1-Pint Urinal
K-5452-ET
/