Hearthland NOKOMIS Owner's manual

Category
Pellet stove
Type
Owner's manual

This manual is also suitable for

VS0952_H 2/12/2010
SAFETY NOTICE
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF
THIS PELLET FUEL-BURNING ROOM HEATER. FAILURE TO FOLLOW THESE
INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY
OR EVEN DEATH.
SAVE THESE INSTRUCTIONS.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS
AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA.
WARNINGS
Hot! Do not touch! The glass and surfaces of this ap-
pliance will be hot during operation and will retain
heat for a while after shutting off the appliance. Se-
vere burns may result!
Hearthland pellet burning appliances are designed for
use as a supplemental heater. They are not intended
for continuous use as a primary heat source.
PELLET STOVE
INSTALLATION AND OPERATION MANUAL
Hearthland Itasca
Pellet Stove
Hearthland Hiawatha
Pellet Stove
Hearthland Nokomis
Pellet Stove
VS0952_H 2/12/20102

CONGRATULATIONSonthepurchaseofyourHEARTHLANDstove!Withthepur
chaseofyournewpelletstove,youhavejoinedcountlessindividualswhoseanswer
totheirheatingneedsreflectstheirconcernforaesthetics,efficiencyandourenvi
ronment.
Thefollowingarekeyfactorsrelatingtotheinstallationandoperationof
yourstove
andheatingwithwoodpelletfuel.
1.Aqualityinstallationwhichmeetsallsafetyandbuildingcoderequirementsisa
mustforthesafetyofyourfamilyandforefficient,satisfactoryoperationofyour
stove.
2.UsequalitypelletswithhighBTUcontentandminimum“fines”,
sawdustand
loosematerials.Pelletsvarygreatlyfromcompanytocompany.Pelletquality
contributessignificantlytoyourstovesperformance.Forpeakperformanceitis
recommendedthatyouscreenyourpelletstopreventoperationalproblems.
(SeeSection#5“WoodPelletSpecifications”)

3. Keepyourstove’sburngrateclean.Adirtyburn
graterestrictscombustionair
makingitdifficulttomaintainpropercombustioncontributingtopoorperform
anceandincreasedfuelusage.(SeeSection#6“Maintenance&RequiredClean
ing”)
4.Keepyourstove’sheatexchangerclean.Adirtyheatexchangerreducesheat
transfertoconvectionaircontributingtopoorperformance
andincreasedfuelus
age.(SeeSection#6“Maintenance&RequiredCleaning ”)

Inthemajorityofthecases,operationalproblemsaretheresultofpoorqualitypel
lets,improperinstallation,and/orlackofcleaning.DailycareofyourHEARTHLAND
stovewillprovideclean,efficient,comfortableandenvironmentallyfriendly
heating
formanyyears.Weextendourcontinuedsupporttohelpyoutoachievethemaxi
mumbenefitandenjoymentfromyournewpelletstove.Foradditionalinformation
andoperationaltipsgoto:
www.Hearthlandproducts.com
ThankyouforselectingHearthlandProductspelletstoveasthesolutiontoyourzone
heatingneeds.
COPYRIGHT NOTICE
Copyright 2009, Hearthland Products LLC All rights reserved.
No part of this manual may be copied, transmitted, transcribed, stored in a retrieval system,
in any form or by any means without the expressed written permission of Hearthland
Products LLC; Bloomington, MN
VS0952_H 2/12/20103
TABLEOFCONTENTS
1GENERALINFORMATION 4.12SETTINGMODEOFOPERATION
28
1.1IMPORTANTSAFETYITEMS
4
4.13THERMOSTATMODES(OPTIONAL)
29
1.2SAFETYLISTING
5
5WOODPELLETSPECIFICATIONS
30
1.3HOWYOURHEARTHLANDSTOVEWORKS
6
6MAINTENANCE&REQUIREDCLEANING
31
1.4AUTOMATICSAFETYFEATURES
7
7MANUALIGNITIONOFSTOVE
36
1.5SPECIFICATIONS
8
8WIRINGDIAGRAM
37
1.6ELECTRICALINFORMATION
8
9TROUBLESHOOTING
38
2PREPARATIONFORINSTALLATION
10REPLACEMENTPARTSLIST
41
2.1PREINSTALLATIONCHECKLIST
9
11LIMITEDWARRANTY
49
2.2PELLETVENTTYPE
10
2.3VENTSAFETYPRECAUTIONS
10

2.4D
ETERMINGVENTINGSIZE&DISTANCE
11
2.5PELLETVENTTERMINATION
12
2.6OUTSIDEAIRINTAKE
14
2.7HEARTHPROTECTION&CLEARANCES
15
2.9REQUIREMENTSFORFLOORPROTECTION
15
2.10MINIMUMCLEARANCESTOWALLS&COMBUSTIBLES
15
3INSTALLATION
3.1SUGGESTEDINSTALLATIONTOOLS
18

3.2
INSTALLATION
19

3.3M
OBILEHOMEINSTALLATION
22

4O
PERATINGINSTRUCTIONS

4.1S
ETTINGTHEINTAKEDAMPER
23

4.5I
NTELLIGENTTEMPERATURECONTROL(ITC)GEN
ERAL
OVERVIEW
24

4.6S
TARTINGSTOVE&SHUTTINGOFFSTOVE
25

4.7A
DJUSTINGSTOVESETTINGS

26

4.8S
ETTINGHEATLEVEL
26

4.9S
ETTINGFANSPEED
26

4.10C
OMBUSTIONFANSPEEDADJUSTMENT(F1)
27

4.11ITCT
EMPERATUREADJUSTMENT(T1)
27

4.12A
DJUSTINGAIRINTAKEDAMPER
27




2.8L
OCATINGSTOVE
15
4.3BURNGRATEREMOVAL&INSTALLATION
23

4.2D
OOROPERATION
23

4.4F
ILLINGHOPPERWITHFUEL
24

VS0952_H 2/12/20104
Contactyourlocalbuildingofficialbeforeinstallation,toobtainthenecessarypermitsandinformation
onanyinstallationrestrictionsorinspectionrequirementsinyourarea.
Thisunitmustbeproperlyinstalledtopreventthepossibilityofahousefire.Theinstructionsandlocal
buildingcodesrequirementsmustbestrictlyadheredto.
Read,saveandfollowtheinstructionsinthismanual.Itcontainsimportantsafety,operating
andmaintenanceinstructionsyouwillneed.
Foryourprotectionandwellbeing,HearthlandProductsrecommendsinstallingasmokedetectoras
wellasaCarbonMonoxidedetectorintheroom.
Wheninstalledinamobilehome,theHearthlandmustbeboltedtothefloorandsupplied withoutside
air.Undernocircumstancesshoulditbeinstalledinabedroom(PerH.U.D.requirements).
NEVERtrytorepairorreplaceanypartofthestoveunlessinstructedtodosobytheHearthland
CustomerServiceDepartment.Werecommendyouuseatrainedtechnicianforallrepairs.
Stovesaredangerouslyhot.Youngchildrenshouldbesupervisedwhentheyareinthesameroomas
thestove.
TheHearthlandisdesigned andapprovedforpelletizedwoodfuelonly.Anyothertypeoffuelburned
inthisstovewillvoidthewarrantyandsafetylisting.Keepforeignobjectsoutofthehopper.
NEVERusegasoline,gasolinetypelanternfuel,kerosene,charcoallighterfluid,orsimilarliquidstostart
or’freshenup’afireinthisheater.Keepallsuchliquidswellawayfromtheheaterwhileitisinuse.
TheHearthlandisdesigned touseastandard115Volt3pronggroundedelectricaloutlet.Agrounded
surgeprotectorisstronglyrecommendedtopreventdamagetoyourstoveintheeventoflightningor
otherpowersurgeinstances.
Neveruseanadapterplugorseverthegroundingprongonthe
electricalplug.
Neverroutetheelectricalcordunderneath,infrontof,overthestoveorovertheexhaustpiping.
Ifyoususpectamalfunctionpush the“OFF”TouchPadandinspectthestove.
Note:TheHearthlandStov ewillnotoperateduringapoweroutageunlessattachedtoacorrectly
sizedgeneratororbatterybackup.Ifapoweroutageoccurs, openawindowtoventanysmokefrom
room.Ifthemalfunctionpersistsunplugtheunitandcallyourauthorizeddealer.
Neveroperatethestoveifyousmellsmokecomingfromanywhereonthestove.Ifthisoccursturn

yourstoveoffandcallyourauthorizeddealer.
CAUTION:Fuelisfedtothefireboxbyascrewaugerdrivenbyahightorquemotor.Thisaugercanstart
andstopwithoutwarningwhilestoveisinoperation.NEVERputfingersinornearpelletfeedauger,as
seriousinjurycouldoccur.Note;yourHearthlandstoveisequipped
withahoppermountedcutoff
switchwhichpreventstheaugerfromrunningwhenhopperlidisopen.Donottamperwiththisswitch.
ImportantSafetyItems
 IMPORTANT
VS0952_H 2/12/20105
Shutstoveoffifthefirepotoverfillswithpelletsortheflamebecomesdarkandsooty.Thisindicates
poorfuelcombustionandthecauseshouldbeinvestigatedandremedied.(SeeTroubleShootingtipsfor
possiblecauses)
It’scriticalforproperoperationthatyoumaintainunobstructedairflowthroughtheintakeventsofthe
stove.Theviewingdoorandashpanmustbeclosedandlatchedduringoperation.Neverabusethe
doorbyslammingitshut.
Thepelletapplianceexhaustsystemworkswithnegativecombustionchamberpressureandpositive
chimneypressure.Theexhaustsystemmustbecompletelyairtightandproperlyinstalled.Allexhaust
ventjointsmustbetightlysealedwithgasketandorHITEMP
(550°F)RTVsiliconesealant,andatleast3
sheetmetalscrewsperjoint.
ForrequiredperiodicmaintenanceandcleaningrefertoSection#6“Maintenance&RequiredCleaning”
ofthismanual.Failuretomaintainyourstovemayleadtopooroperationandexhaustfumeleakage
intoyourhome.Onlyusereplacem entcomponentsthatareauthorizedbyHearthlandProducts,LLC.
Alwaysdisconnectpowerfromyourstovebeforeperforminganymaintenance.PowerCordmustbe
unplugged.Pushing” OFF”TouchPaddoesnotdisconnectallpowertothestove.
Toavoidaccidentalfire,DONOTplaceanyflammable itemonornearthestove.
Topreventburns,maintenanceorcleaning,shouldonlybeperformedonacoolstove.
HearthlandProductsgrantsnowarranty,impliedorstated,forthemaintenanceorinstallation
ofyourstove,andassumesnoresponsibilitywhatsoeverofanyconsequentialdamageto
stoveoritssurroundings.
SAFETYLISTING:
InaccordancewiththeproceduresandspecificationslistedinASTME150904,ULC/ORDC1482M1990,andULCS627
00forsolidfuelroomstove,HearthlandProducts,pelletstoveshavebeenindependentlylistedbyOmniTestLaborato
ries,Inc.Portland,Oregon(anaccreditedtestinglaboratory).Itistestedandlistedforresidential
installationaccording
tocurrentnationalandlocalbuildingcodesas:
FREESTANDINGROOMHEATER
ROOMHEATER,PELLETFUELBURNINGTYPE,
ALSOFORUSEINMOBILEHOMES
TheSafetyListingLabelislocatedontherear
panel.Readthelabelcarefully.Itcontainsinfor
mationabouttheinstallationandoperationof
yourstove.Thestove’sserialnumberislocated
onthesafetylabel.Yourserial
numberispre
cededbya“OMNI(exampleOMNI00000).(see
diagram).
 IMPORTANT
VS0952_H 2/12/20106
HOWYOURHEARTHLANDSTOVEWORKS
Theoperationsandmaintenanceofyour
HearthlandSeriesofpelletfuelappli
ancesareuniqueandshouldnotbecon
sideredtobelikeawood,coal,gas,elec
tric,propaneoroilburningstoveappli
ance.
Woodpelletfuelisstoredinthehopper.An
augerdeliversthefueltotheburngrate.The
fuelrate,orheatoutput,issetbyadjusting
theHeatLeveltouchpad,(settings1to4).A
fanprovidescombustionairtotheburngrate.
Theproperamountofcombustionair
issup
pliedtotheburngrateautomaticallyand
changesastheHeatLevelchanges.The
highertheHeatLevel,thelargertheamount
ofcombustionair.Thefuelburnsintheburn
grate,producingheat.Mostofheatpasses
aroundtheheatexchangetubesandisblown
intothe
roombytheconvectionfan.Exhaust
gasesexitthroughthestove’sexhaustvent.
TheHearthland’sheatoutputcanbeadjustedfrom
HeatLevelsetting14,bypressingontheHeatLevel
touchpad.
TheconvectionfancanbeadjustedusingtheFan
Speedtouchpadtorunfasteror
slowertocorre
spondtotheamountofheatbeingproduced.
Toturnoffthestove,simplypressing“OFF”onthe
touchpad,andtheunitwillentershutdownmode
untiltheithassufficientlycooled.
Withuninterruptedfuelsupplyandproperperform
anceofcleaning,yourstovewillrun
efficientlyover
extendedperiodsoftime.(SeeSection#6“Maintenance&RequiredCleaning”)
YourHearthlandstoveisdesignedtoburnonlywoodpelletsthat complytoAssociationof
PelletFuelIndustriesstandards.(SeeSection#5“WoodPelletSpecifications”)
Donottrytooperateyourstovewithviewingdooropen.Pelletswillnot feedunderthese
circumstancesandasafetyconcernmayarisefromsparksorfumesenteringroom.
Ifyouarenotdrawingcombustionairfromoutside,caremustbetakentoallowforade
quateairmakeup,toavoidpossibleroomairstarvationwhenstoveorotherexhaustfans
areinoperation.
Itishighlyrecommendedthatyouinstallahighqualitysmokedetectorandcarbonmonox
idedetectorintheroomwherestoveisinstalled.Careshouldbetakentomakesuredetec
torsareinworkingorderatalltimes.
 IMPORTANT
HEATLEVELCONTROL
FANSPEEDCONTROL
VS0952_H 2/12/20107
AUTOMATICSAFETYFEATURES
ShutdownMode
Thismodestopstheaugerfuelfeedsystemandrunsthecombustion&convectionblowersfor10minutesor
untilthestoveexhaustcoolsbelow120°F,atwhichpointallelectricalcomponentswillbeoff.Shutdownmode
occurswhen“OFF”ispressedonthetouchpadorfromothercauses.If
thishappensunintentionally,findand
correctthecauseandpressstartonthetouchpad.(SeeSection#9“Troubleshooting”)
HopperLidSwitch
Thisdeviceismountedontherightsideofthehopperopening.Whenthehopperdoorisopen,theswitchstops
theaugerfeedsystem.Ifthehopperdoorisleftopenformorethanoneminute,theunitwillentershutdown
mode.Ifthishappensunintentionally,simplyclosethe
doorandpressstartonthetouchpad.
VacuumSwitch
Thevacuumswitchensuresthatthevacuumoftheentirecombustionsystemismaintained.Theswitchislo
catedontheinnerrearwalloftheunitandtakesmeasurementfromthefreshairintaketube.Ifthevacuum
switchfailstoreadadequatenegativepressureformorethanoneminute,
theunitwillentershutdownmode.
Thisfeatureensuresthatthestovewillnotoperatewiththedoorajarortheashpantightenedincompletely.If
thishappens,findandcorrectthecauseandpressstartonthetouchpad.(SeeSection#9“Troubleshooting”)
IntelligentTemperatureController(ITC)
TheITCfeatureofyourstovemonitorstheexhausttemperatureandadjustsfuelfeedaccordinglytomaintain
consistentheatoutputtemperatures.Inthismanner,theITCisabletoregulatestoveheatsettingswithgreat
accuracy,compensatingforvariationsinfuelsuchassizeandBTUcontentaswellasoptimizing
fuelefficiency
andpreventingoverfiring.
L250HighLimitSwitch
Yourpelletappliancehasahightem
peraturelimitswitchasanaddedsafety
measureiftheITCweretofail.Ifthe
temperatureatthislocationexceeds
250°F,theunitwillentershutdown
mode.Ifthisoccurs,findandcorrect
thecauseandpressstartonthetouch
pad.(SeeSection#9“Troubleshooting”)
PowerLossMemory
Ifthepowerlostduringoperation,the
stovewillstoprunningandthefirewill
extinguish.Whenthepowerisre
stored,thestovewillrestartand return
totheheatandfansettingitwasoper
atingatbeforepowerwaslost.
VACUUM
SWITCH
L250
SWITCH
ITC
HOPPER
SWITCH
VS0952_H 2/12/20108
SPECIFICATIONS
ElectricalInformat ion
Yourstoveiswiredatthefactoryfor120V,60Hzoperation,5.5ampsatstartup.Connecttoa120
V,15Acircuitandusea15Atimedelayfuseorcircuitbreaker.Itisrecommendedtouseaground
faultoutlet(GFCI)andasurgeprotector.
*Heatingcapacitywillvarydependingonsuchfactorsasthelayoutofyourhome,aircirculation,degreeofinsulation,
andtheoutsidetemperature.
**PelletBTUcontentwillaffecttheactualrateoffuelfeedandburntimes..
Heatingcapacity(sq.feet)* UpTo2,500 WeightItasca(lbs) 218
Fuelburnrateperhour** 1.25—5.9lbs WeightNokomis(lbs) 254
BTUInput 10,875‐51,300 AirIntakeDiameter 2"
HopperCapacity 70lbs ExhaustDiameter 3"
Hopperburntimeatlowestsetting 56hrs Efficiency 78%
VS0952_H 2/12/20109
PREINSTALLATIONCHECKLIST
Unlessyouareexperiencedinstoveinstallation,werecommendyourHearthlandAppliancereceivea
PredeliveryCheckandbeinstalledbyyourlocalSpecialtyRetailer,NFI(NationalFireplaceInstitute)
PelletSpecialist(USA)orWETTCertifiedInstaller(CAN).
HearthlandProductsneithergrantsor
impliesanywarrantyorresponsibilityforfaultyinstallations!
COMPLETETHISCHECKLISTPRIORTOINSTALLINGYOURHEARTHLANDSTOVE:
_____Carefullyreadandsavethis"OwnersManual”.
_____HaveyourlocalDealerdemonstrateyourHearthland’soperation,cleaningandmaintenancesteps.
_____Selectalocation.Thedesignofyourhomeandthestoveplacementwilldetermineitseffectivenessasa
sourceofheat.Apelletappliancedependsonaircirculationtocirculateheat.Otherpractical
considerations,tobeconsideredbeforeafinalplacementisdecidedonmayinclude:
ExistingChimneys,Fuel
Storage,Aesthetics,RoofDesign(rafterlocations&roofpitch),Room
Traffic,ClearancestoCombustibles,andExistingWiring.
_____Theinstallationofthisappliancemustconformtolocalcodesandapplicablestateandfederal
requirements.Becomingfamiliarwiththeserequirementsbeforeinstallationisessential.
______ Selectalocationforthestovethatadherestorequiredsafetyclearances.
______ Ensurethestovemustbemountedonahearthpad
orequivalent.
______ Attachproofofpurchasetothismanualandsaveforwarrantyquestions.
*******************************************************************************************
COMPLETETHISCHECKLISTWHILEINSTALLINGYOURHEARTHLANDSTOVE:
_____ReadtheInstallationsectionsofthismanual.
_____Determinethelocationandmeasurementsneededtoinstallthestoveinyourchosenlocation.
_____Prefitallitemsbeforeyouinstall,fastenorinstallthestovepermanently.
_____MakesureALLjointsof“PL”ventandsinglewallstainlesssteellineraretightlyconnected,sealedwith
HighTemp(550°F)RTVSiliconeorHiTempfoiltape,includingtotheexhaustconnector,andarecor
rectly
installed.(Followventmanufacturer’sinstructions.)
********************************************************************************************
COMPLETETHISCHECKLIST,BEFORELIGHTINGYOURFIRSTFIRE:
_____Obtainfinalinspectionandapprovalbylocalbuildingofficials.
_____Carefullycleanallmarksoffthepaintedandpolishedmetalpartsbeforethefirstfiring.Useasoftclothanda
mildcleaner.Failuretodosomayresultinmarksorfingerprintsbeingpermanentlyvisibleonthesurface.
Caution:Neveruseanabrasivecleaneronanypart
ofyourstove.
_____Cleanandwipethehoppertoremoveanydebrisorresidualoilfromthemanufacturingprocess.
_____YourstovehasbeenpaintedusingStoveBrighthightemperaturestovepaint.Thispaintisnotfullycureduntil
thestoveisfired(3)times.Theinitial(2)stoveburnsshouldbeatheatsetting2for30minutes.Between
burnsturnoffthestoveandallowpaintedsurfacesto
cooltoroomtemperature.Thethirdburnshouldbeat
heatsetting3for60minutes.Duringthiscuringprocessfumeswillbegivenoff.Openwindowsanddoors
andusefanstoprovidefreshairwhilecuring.Fumeswillnotbepresentafterpaintfullycures.
_____Makesurethatstoveisconnectedtoasurgeprotectionunit.
_____ Removepackagingmaterialsfromtheburnarea.
_____Fillthehopperwithqualitypellets.(Seesection#4.4FillingHopperWithFuel”)Closehopperaccessdoor.
_____FollowtheHearthland’sLightingandIntelligentTemperatureControlInstructions.(Seesection#4.6“Starting
Stove”)
VS0952_H 2/12/201010
EXHAUSTSYSTEM
PELLETVENTTYPE:
Mustbeanapproved3”or4”DiameterType”PL”vent,ventedtotheoutsideorconnecttheventtoa
factorybuilttype“A”chimneyusinganadaptor.
Exception:Asinglewall“AllFuel”StainlessSteelchimneylinermaybeusedinsideafireplaceorfire
placeinstallations.
Someventingmanufacturesdomake“PL”ventforusewithwoodpelletfuelonlyandanothertypeof
“PL”ventforcornorbiomassfuels.Ifindoubt,planforthefutureandusethecornormultifuel.
Use4”diameterventifventorlinerheightis
over15’orifinstallationisover3.000’abovesealevel.
NOTE:4”diameterventmaybeusedinallinstallations.Ifindoubt,use4”diametervent.(Seediagram
onPage11.)
VENTSAFETYPRECAUTIONS:
A“CleanOutTee”(A)mustbeinstalledatthebottomofallverticalruns.These“Tee’s”aretoassistin
periodicallycleaningthevent.SingleorDoublecleanoutteesmaybeused.Theexhaustsystemmust
beinstalledsotheentiresystemcanbecleanedwithout
disassembly.
Terminationmustexhaustabovethefreshairinlet
elevation,andparallelorabovetheexhaustoutput
ofthepelletfuelappliance.
Itishighlyrecommendedthatatleast3feetofvertical
pipe(B)beinstalledtocreatesomenaturaldraft.This
istohelppreventthe
possibilityofsmokeorodordur‐
Ingtheapplianceshutdown.
Horizontalsectionsmusthavea1/4”riseevery12”of
travelafter3’long.
Use(3)fasteningscrewsperjoint.
Pelletventconnectionsmustbesealedgastight.Use
HighTemp(550°F)RTVSiliconeorHitemp
Aluminumfoil
tape.
Sealeachventsectionbyinjectingaliberalamountof
sealantintothegaporwrapwithfoiltape.

Itisstronglyrecommendedthattheexhaustsystem
beterminatedontheprevailingwindsideofthehome.
Appliancemaynotbeplacedin,orvented
through
THEPELLETVENTMUSTMAINTAINAMINIMUM3”CLEARANCETOANYCOMBUSTIBLE.
(INSTALLVENTATCLEARANCESSPECIFIEDBYTHEVENTMANUFACTURER).
DONOTINSTALLAFLUEDAMPERINTHEEXHAUSTVENTINGSYSTEMOFTHISUNIT.
DONOTCONNECTTHISUNITTOACHIMNEYFLUESERVINGANOTHERAPPLIANCE.
 IMPORTANT
VS0952_H 2/12/201011
EXHAUSTSYSTEM(CONTINUED)
DETERMINEVENTINGSIZEANDDISTANCE:
Itisrecommendedthattheventsystembeinstalledwithaminimumofthreefeet(3’)ofvertical
riseabovetheapplianceexhaustport.
EquivalentVentLength(EVL)isthemethodofdeterminingventsizesandlengths,thattakesintoaccountthe
effectofdifferentcomponentpartsonairflow.
Pellet Venting
Component
# of Elbows
OR feet of Pipe
Multiply by Equivalent
Feet
Component
Equivalent
90 Degree or Tee X 5
45 Degree X 3
Horizontal Pipe X 1
Vertical Pipe X .5
Total Equivalent
Step1 Completetableabove.
Step2 EnsuretheTotalEquivalentisoris
lessthan30.
Step3 UsetheSizingCharttodetermine
theproperventingsizeaccording
totheTotalEquivalentandthe
Altitudeabovesealevel.

NOTE: Insomecasesitmaybenecessary

tocontactHearthlandCus tomer
Servicepersonneltodeter
mineacceptableventing
 configurationsandaltitude 
adjustments.
Call: 18888832260.
Diagramforvisualreference.
0 1 2 3 4 5 6 7 8 9 10
10
20
30
Altitud e in Thousa nd s of Fe e t
E
q
u
i
v
a
l
e
n
t
P
i
p
e
L
e
n
g
t
h
i
n
F
e
e
t
3 or 4 Inch Diameter Pipe
4 Inch Diameter Only
VS0952_H 2/12/201012
EXHAUSTSYSTEM(CONTINUED)
PELLETVENTTERMINATION:
Terminationmustbeaminimumof12”above
thechasecap(DIM“A)(note:thechimneymust
meetlocalcodesforheightabovetheroofor
otherobstructions)
Musthaveanapprovedcap(B)(topreventwa
terfromentering)ora45*elbowdownturn.
Ifthe
terminationislocatedonthepredomi
nantlywindysideofthehouse,anapproved
houseshieldisrecommendedtopreventsoot
fromaccumulatingonthesideofthehouse.
Mustnotbelocatedwheresnoworothermate
rialssuchasleafs,snoworgrass,couldblockit.
Musthave
a“MetalSealPlate”or“WallThim
ble”atpoint(C)
Horizontalterminationsmustprotrude12from
thewall,verticalterminations24”
Minimum3’clearanceaboveanyforcedairin
takeofanyotherappliancewithin6’.
Minimum3’aboveagasmeter/regulatorwithin
3’horizontallyofthe
verticalcentrelineofregulator.
Minimum6’clearancetoagasserviceregulatorventout
let.
Minimum1’clearanceunderveranda,porch,deckorbal
cony.Permittedonlyifstructureisfullyopenonamini
mumoftwosidesbeneaththefloor.
VS0952_H 2/12/201013
EXHAUSTSYSTEM(CONTINUED)
PELLETVENTTERMINATION:
VS0952_H 2/12/201014
OUTSIDEAIRINTAKE
Outside air is strongly recommended for all other installations as well. Failure to install intake air
may result in improper combustion as well as the unit emitting smoke during power failures.
Metal pipe, ONLY, either solid or flexible, must be used in all outside air installations.(B)
A wind shield, (C), over the termination of the outside air intake pipe or a 90 degree elbow or
bend directed away from the prevailing winds MUST be used when an outside air pipe is in-
stalled through the side of a building. Keep the outside air pipe termination at least 1 foot away
from the exhaust system termination. Keep the pipe termination clear of debris, ice & snow. In-
spect the termination on a routine basis.
When outside air is taken from an existing chimney, the exhaust system must not terminate in the
same chimney.
The air intake pipe on your stove is 2" OD. The outside air connecting pipe must be at least 2" ID
The outside air connecting pipe must be as short and free of elbows as possible, and must fit
over the air intake pipe on your stove.
2”AIRINTAKE
3”EXHAUST
FORMOBILEHOMEINSTALLATIONS,OUTSIDEAIRINTAKEISREQUIRED.
Nonmetallicmaterial,suchasPVCorABSplasticpiping,mustnotbeusedforoutsideair
 IMPORTANT
VS0952_H 2/12/201015
HEARTHPROTECTION&CLEARANCES
LOCATINGSTOVE:
Keepinmindthefollowingplacementconcerns;ventingobstructions,outsideair,electricalout
let,wallthermostat,heatdistribution,trafficpatternsandroomuse/size.
Ifthestoveisplacedinalocationwheretheceilingheightislessthan7’,itmustfollowthere
quirementsinthesection“AlcoveInstallation”.
Althoughnotrequiredforsafetyreasons,itisstronglysuggestedthatsufficientspacebepro
vided(aminimumof24”)oneachsideoftheapplianceandatthebackoftheappliancetoen
ableservicingtheunitifnecessary.Ifthisspaceisunavailable,aprovisionmustbemade
toen
ableslidingtheapplianceout.
MINIMUMCLEARANCETOWALLS&COMBUSTIBLES:

2”FromBackOfStove
6”FromSideofStove(8”inCanada)
6”FromFrontOfStove(18”inCanada)
16”FromTopOfStove(8”inCanada)
3”FromPLVenttoCombustibles
2”FromBackCornerofStove
36”todrapes,doors,anythingthatcanswingtowardstove.
REQUIREMENTSFORFLOORPROTECTION:
Stoveandfloorprotectionmustbeinstalledonalevelsecurefloor.
Itisimportantforyourappliancetobelevel.Levelingshouldoccurbelowthefloorprotection
pad.
Thestovemustbeinstalledonanoncombustiblefloorprotector(i.e.sheetsteelwithcement,
tileslate)extendingthefullwidthanddepthofthestove.
FLOORPROTECTIONMUSTEXTEND:
6”beyondfrontofthestove(18”inCanada)
6”beyondsidesofthestove(8”inCanada)
2”beyondrearofthestoveandtoeithersideofchimneytee.
VS0952_H 2/12/201016
HEARTHPROTECTION&CLEARANCES
CLEARANCES—STRAIGHTTHROUGHWALLINSTALLATION
CLEARANCES—INTERIORVERTICALINSTALLATION
VS0952_H 2/12/201017
HEARTHPROTECTION&CLEARANCES(CONTINUED)
 CLEARANCES45°CORNERINSTALLATION
CLEARANCESALCOVEINSTALLATION
VS0952_H 2/12/201018
SUGGESTEDINSTALLATIONTOOLS

PowerTools
ShopVacuumforcleanup
Reciprocatingsaw
Electricdrill
Extensioncord
4”or5”diametercoringbitanddrill
(ifgoingthroughconcrete)
HandTools
TapeMeasure
CaulkingGun
Pencil
Allen(Key)wrenchset
StudFinder
Setofsocketsornutdriver(7/16”)
Screwdriver,PhillipTip
Assortmentofmetal,masonry,andwooddrillbits
Flashlight
HandTruckorcart(fortransportingstovetoinstallationlocation)
Hammer
Level
Utilityknife
Adjustablepliers(6to8inches)
Smallhandbroomanddustpan
FurnitureandFloorProtection
Supplies
CaulkingtubeofRTVHiHeatSilicone(550°F)
Selfdrillingscrewsforventingjoints((3)perjoint)
Assortmentofsheetandwoodscrews
Paintfortouchup
CaulkingtubeofClearSilicone
Hi–HeatAluminumFoilTape
Before starting your Hearthland Pellet Stove install, we recommended you review the following list of tools that
may be required and have them ready if needed.
VS0952_H 2/12/201019
INSTALLATION
THROUGHTHEWALL,DIRECTVENTINSTALLATION.
1. Selectthelocationforyourstove,designtheexhaustsystemanddeter
minethebrandandsizeof"PL"venttobeused.
2. Positionthefloorpad.
3. Followingthe"PL"ventmanufacturer'sspecifications,markandcutahole
throughthewalltoaccommodatethewallthimble,(6),
andtheoutsideair
pipe,(9),ifoutsideairistobeused.Rememberthattheoutsideairintake
mustbelocatednocloserthan12fromtheventexhaust.Trytoavoid
cuttingwallstuds,anduseextremecautiontoavoidcuttingintopoweror
waterlineswithinthewall
ofyourhome.
4.Installthewallthimble,(6).Besuretorunabeadofsiliconearoundtheout
side edges of the wall thimble to reduce drafts, both inside and outside.
Insertthepropersizeof"PL"vent,(5),throughthewallthimble,(6).
5.Placeyourstove
on thefloorpad,closetoitsfinalposition.Leaveroomto
connectthe"PL"ventto“Quick Connect”endcollar.Installthegasket (2)
and“QuickConnect”exhaustend(3)toyourstovetothe“QuickConnect”mountingplate.Usethe(4)7/16”nuts,tose
curetightly.
6.
PlaceabeadofHighTemp(550°F)RTVsiliconearoundtheendcollarofthe“QuickConnect”ofyourstove'sexhaust,(3).
Firmlypushthe“PL”ventpipeadaptor(4)intothebeadofHighTemp(550°F)RTVsilicone.
Note:If4"PLventisrequired,usean3”to4”PipeAdaptorIncreaser,(4),onthestoveexhaustpipe.
7. Connectthelength of "PL" vent, (5), that is in the thimble, (6),onto the pipe adaptor (4).Fasten together with at least
threesheetmetalscrews(approx.3/8”inlength).PlaceabeadofHighTemp(550°F)RTVsiliconearoundtheconnection.
8. Placeyourstoveinits finalpositionon thepad.PlaceanotherbeadofHighTemp(550°F)RTVsilicone aroundthe“PL”
vent(6)andtheinsideofthewallthimble,tostopcoldairdrafts.
9.Ontheoutsideofthebuilding,placeanexhaustcap(7)ora45degree"PL"typeelbow,(7),ontotheendofthehorizontal
"PL"vent,(5).Optionally,placearodentscreencap(mayberequiredinsomelocals),ontheendoftheelbow,(7).Runa
beadofHighTemp(550°F)RTVsiliconearoundallconnectionsandaroundthe“PL”ventpipeandtheoutsideofthewall
thimble.Note:Theendoftheexhaustpipemustextendaminimumof12”fromtheoutsideofthebuilding.
Note: Most horizontal, through the wall installations may require a Clean-out Tee and minimum 3 feet vertical
rise of pipe, inside or outside the building.
VS0952_H 2/12/201020
These styles of installation are highly recommended, due to possible backpressure in the exhaust caused by
airflow around the outside of the structure, snow build-up, or power failure, etc.. These designs will improve
venting performance and provide natural draft to help evacuate smoke from the appliance in case of power
failure. Follow the same basic steps in locating your appliance, attaching the exhaust system and outside air
intake to your stove as the previous examples.
INSTALLATION , CONTINUED
HEARTHSTOVE—EXISTINGRELINE
RAIN CAP
STORM COLLAR/ROOF
FLASHING
EXISTING CHIMNEY
16”
24”
PL VENT
OPTIONAL
STEEL PLATE
(CHIMNEY MUST BE SEALED TO PREVENT DOWN-DRAFTS & WEATHER)
MAINFLOOR—VERTICAL
TEE SUPPORT
TEE & END CAP
CEILING SUPPORT
FIRESTOP
PIPE SUPPORT BRKT
STORM COLLAR/ROOF
FLASHING
RAIN CAP
PL VENT
WALL THIMBLE
TEE & CAP
TEE SUPPORT
ROOFLINE
WALKOUTBASEMENTORMAINFLOOR
BASEMENTORGROUNDFLOOR
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51

Hearthland NOKOMIS Owner's manual

Category
Pellet stove
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI