Hagerco 2-679-0621 - 2 Conductor, - Alum. Powder Coat Power Transfer, 2-679-0622 - 2 Conductor, Dark Brown Powder Coat Power Transfer, 2-679-0623 - 10 Conductor, - Alum. Powder Coat Power Transfer, 2-679-0624 - 10 Conductor, - Dark Brown Powder Coat Power Transfer Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Hagerco 2-679-0621 - 2 Conductor, - Alum. Powder Coat Power Transfer Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Heavy Duty Power Transfer
Installation Instructions
I-EA00075
Rev 1, Rev Date: 1/29/14
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995
HEAVY DUTY POWER TRANSFER-2WIRE/10WIRE
(Products Covered By This Drawing: 2-679-0621, 2-679-0622, 2-679-0623, 2-679-0624)
ELECTRICAL RATINGS
2WIRE (2) 18AWG WIRES-MAX RATING 24VDC, 5A or 120VAC NEC CLASS 3
10WIRE (10) 24AWG WIRES-MAX RATING 24VDC, 1A
1/4
7-3/4
5/8
FOR
FRAME
1/4
5/8
FOR
DOOR
1-5/8
METAL DOOR
OR FRAME PREP
(SIDE VIEW)
WOOD DOOR
OR FRAME PREP
(SIDE VIEW)
1" DIA
5/8” DIA
THRU TO
WIRE
CHANNEL
1/4
REINFORCEMENT
1/16(16 GA)
MIN
9-1/16"
21/32"
1-1/4
MIN
FRAME
3/8
3/4
DOOR
(OPEN 180 )
8-3/8
11/32"
WOOD:
HOLES DRILLED
DURING INSTALLATION
METAL:
#10-24 TAPPED HOLES
12 PLACES
7/8” FROM
OUTSIDE
FACE OF
DOOR
3-3/4” MAX
WHEN
INSTALLED
C
L
C
L
OF PT IN FRAME MUST ALIGN
WITH OF PT IN DOOR
C
L
C
L
RECOMMENDED 6" BELOW UPPER HINGE
ON DOORS UP TO 7'-0" HIGH.
LOCATE 24" BELOW UPPER HINGE ON DOORS OVER
7'-0" TO 10'-0" HIGH.
NOTE: FOR WOOD FIRE DOOR, CONSULT DOOR
MANUFACTURER FOR APPROVED LOCATION.
Page 1 of 1
/