Hagerco 2-679-0620 - Concealed Mortise Mount Power Transfer Loop Installation guide

Type
Installation guide
2-679-0620 Power Transfer
Installation Instructions
I-EA00074
Rev 3, Rev Date: 8/20/14
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995
TEMPLATE
CONCEALED POWER TRANSFER
DOOR
PREPARATION
.50" DIA. HOLE x .80" DEPTH
(12.7mm DIA HOLE x 20.32mm DEPTH)
FRAME
PREPARATION
10.25" L x 1.00" W x .75" D
(260.35mm L x 25.4mm W x 19.05mm D)
FOR WOOD AND METAL DOORS AND FRAMES.
INTENDED FOR DOOR
OPENINGS LESS THAN 120°.
NOT INTENDED FOR CENTER HUNG
DOOR APPLICATIONS
NOTE: ACCEPTS JACKETED CABLE
UP TO 5/16" DIAMETER
2"
11/32"
TYP
7/8" FROM OUTSIDE
FACE OF DOOR
#6 SHEET METAL
SCREWS (4 PLACES)
10.25"
.80"
.48" DIA
2X
.594"
10.938"
.75"
11.438"
1.00"