Heavy Duty Power Transfer
Installation Instructions
I-EA00075
Rev 1, Rev Date: 1/29/14
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995
HEAVY DUTY POWER TRANSFER-2WIRE/10WIRE
(Products Covered By This Drawing: 2-679-0621, 2-679-0622, 2-679-0623, 2-679-0624)
ELECTRICAL RATINGS
2WIRE (2) 18AWG WIRES-MAX RATING 24VDC, 5A or 120VAC NEC CLASS 3
10WIRE (10) 24AWG WIRES-MAX RATING 24VDC, 1A
1/4
7-3/4
5/8
FOR
FRAME
1/4
5/8
FOR
DOOR
1-5/8
METAL DOOR
OR FRAME PREP
(SIDE VIEW)
WOOD DOOR
OR FRAME PREP
(SIDE VIEW)
1" DIA
5/8” DIA
THRU TO
WIRE
CHANNEL
1/4
REINFORCEMENT
1/16(16 GA)
MIN
9-1/16"
21/32"
1-1/4
MIN
FRAME
3/8
3/4
DOOR
(OPEN 180 )
8-3/8
11/32"
WOOD:
HOLES DRILLED
DURING INSTALLATION
METAL:
#10-24 TAPPED HOLES
12 PLACES
7/8” FROM
OUTSIDE
FACE OF
DOOR
3-3/4” MAX
WHEN
INSTALLED
C
L
C
L
OF PT IN FRAME MUST ALIGN
WITH OF PT IN DOOR
C
L
C
L
RECOMMENDED 6" BELOW UPPER HINGE
ON DOORS UP TO 7'-0" HIGH.
LOCATE 24" BELOW UPPER HINGE ON DOORS OVER
7'-0" TO 10'-0" HIGH.
NOTE: FOR WOOD FIRE DOOR, CONSULT DOOR
MANUFACTURER FOR APPROVED LOCATION.
Page 1 of 1