Mettler Toledo NewClassic Balances MS Semi-Micro Models Operating instructions

Type
Operating instructions
C
1
2
3
4
7
5
6
9
8
10
Cancel running
application
NET
WEIGHING
0
.
00000
g
0
.
00000
g
21
.
01000
g
0
.
00000
g
Net
22
.
00000
g
Unit 1
,
*22
.
00000
g
M
Recall
,
0
.
78000
oz
Unit 2
Execute the assigned
F1 application.
Factory setting:
"Piece Counting"
Execute the assigned
F2 application.
Factory setting:
"Percent Weighing"
Execute the assigned
F3 application.
Factory setting:
"Statistics"
F1
F2
F3
Activate weighing
application
• if activated
• if different
from Unit 1
• if activated
#
,
ADJ.EXT
200
.
00000
g
------
0
.
00000
g
------
ADJ DONE
0
.
00000
g
M
C
C
NewClassic Balances
MS Semi-Micro Models
Quick Guide
Easy Weighing Access
Quick Application Access
Direct Adjustment Access
External Adjustment Procedure
Switching Units
Application Settings
Operation Keys
Display Panel
Tare
Press and hold
Press briefly
Press briefly
Press and hold
Press and hold
Press and hold
Note:
There is a timeout during the setup. The balance switches back
to the last active application.
Press briefly
Press briefly
Execute predefined adjusting
(calibration) procedure
Factory Setting: Internal adjustment
COUNTING
FIX 10
PCS
PERCENT
SET 100
%
STAT
0
.
00000
g
Weight Value Field
Application Icons
Status Icons
Unit Field
Status Icons
Weighing-in aid
Application Icons
Menu locked
Menu settings activated
Application “Weighing”
Application “Piece counting”
Application “Percent weighing”
Application “Statistics”
Application
“Formulation / Net-Total”
Application “Totaling”
Application
“Multiplication factor”
Application
“Division factor”
Application “Density”
Application “PipetteCheck”
Status Icons
Indicates stored values
(memory)
Indicates Net weight values
Adjustments (calibration)
started
FACT activated
Diagnostic mode & Application
“Routine test” activated
Service reminder
Acoustic feedback for pressed
keys activated
Weighing range 1 (Dual Range
models only)
Weighing range 2 (Dual Range
models only)
Not used
Unit Field
Marking of weighing units:
g
gram
mg milligram
ct carat
lb pound
oz ounce
ozt troy ounce
GN grain
dwt pennyweight
mom momme
msg mesghal
tlh Hong Kong taels
tls Singapore taels
tlt Taiwan taels
tola tola
baht baht
>>
Selection available
Weighing-in aid
Marking of nominal or target
weight
Not used
Not used
Weight Value Field
Indicates negative values
Indicates unstable values
Indicates calculated values
Indicates uncertified digits
(approved models only)
Key Functions
No. Key
Press briefly (less than 1.5 s)
Press and hold (longer than 1.5 s)
1
To change display resolution (1/10d
function) while application is running
Note: not available with approved models
in selected countries
no function
2
Enter or leave menu (Parameter settings)
Save parameters
no function
3
Execute predefined adjusting (calibration)
procedure
no function
4
Printout display value
Printout menu settings
Transmit data
no function
5
To navigate back (scroll up) within menu
topics or menu selections
Decrease (numerical) parameters within
menu and in applications
To select the weighing application
Decrease (numerical) parameters quickly
within menu and in applications
6
To navigate forward (scroll down) within
menu topics or menu selections
Increase (numerical) parameters within
menu and in applications
To select assigned F1 application and enter-
ing the parameter settings of application.
Default F1 application assignment: Piece
counting
Increase (numerical) parameters quickly
within menu and in applications
7
With entries: scroll down
To navigate through menu topics or menu
selections
To toggle between unit 1, recall value (if
selected), unit 2 (if different from unit 1)
and the application unit (if any)
To select assigned F2 application and enter-
ing the parameter settings of application.
Default F2 application assignment: Percent
weighing
8
To enter or leave menu selection (from / to
menu topic)
To enter application parameter or switch to
next parameter
To store parameter
To select assigned F3 application and enter-
ing the parameter settings of application.
Default F3 application assignment: Statistics
9
ON/OFF
#
Switch on
Zero/Tare
Switch off
10
C
Cancel and to leave menu without saving
(one step back in the menu).
no function
Net
Mettler-Toledo AG
Laboratory Weighing
CH-8606 Greifensee, Switzerland
Subject to technical changes
© Mettler-Toledo AG 01/2014 11781429E en
www.mt.com/newclassic
*11781429*
Topic Selection
TIME.FORM>>
8
24:MM
12:MM
24
.
MM
12
.
MM
RECALL >>
8
OFF
ON
SHUTOFF >>
8
A.OFF10 min
A.OFF -
A.OFF 2 min
A.OFF 5 min
BCKLIGHT >>
8
B
.
L
.
ON
B.L
.
30 s
B
.
L
.
1 min
B
.
L
.
2 min
B
.
L
.
5 min
DISPLAY >>
8
BRIGHTN. >>
8
50
%
CONTRAST>>
8
75
%
AUTOZERO>>
8
ON
OFF
ZERO RNG>>
8
1.20000 g
LANGUAGE>>
8
ENGLISH
DEUTSCH
FRANCAIS
ESPANOL
ITALIANO
RUSSIAN
POLSKI
CESKY
MAGYAR
NEDERL.
BR.PORTUG.
ASSIGN:F1>>
8
COUNTING
PERCENT
STAT
FORMULA
TOTALING
FACTOR M
FACTOR D
DENSITY
PIPETTE
ASSIGN:F2>>
8
PERCENT
STAT
¦ ¦
COUNTING
ASSIGN:F3>>
8
STAT
¦ ¦
R
.
TEST
COUNTING
PERCENT
DIAGNOSE>>
8
REPEAT.T
DISPLAY
KEYPAD T
CAL
.
MOT. T
BAL
.
HI S T
CAL
.
HI S T
BAL
.
INFO
PROVIDER
SERV.ICON>>
8
ON
OFF
SRV.D.RST>>
8
NO?
YES?
Basic Menu
Advanced Menu
Interface Menu
Protection
Topic Selection
PROTECT>>
8
OFF
ON
Protection
BASIC >>
8
ADVANCED>>
8
INT.FACE >>
8
PROTECT >>
8
,
+
8
C
Topic Selection
WEIG.MODE>>
8
UNIVERS.
DOSING
ENVIRON.>>
8
STANDARD
UNSTABLE
STABLE
CAL >>
8
ADJ
.
INT
ADJ
.
EXT >>
8
200.00
g
ADJ
.
OFF
ADJ.CUST.F>>
8
EXECUTE
RESET >>
8
NO?
YES?
FACT >>
8
TIME >>
8
12:00
OFF
FACT PRT>>
8
ON
OFF
DATE.FORM>>
8
DD.MM.Y
MM/DD/Y
Y-MM-DD
D.MMM Y
MMM D Y
• Enter menu
• Leave menu
with saving
Scroll down
Menu Map
Scroll up
• Enter selection
or menu
• Execute setting
• One step back
• Leave menu
without saving
Menu Operation
Main Menu
Basic Menu
Advanced Menu
Topic Selection
DATE >>
8
01
.
01
.
2008
TIME
>>
8
+
1H
-
1H
SET TIME>>
8
12:00
UNIT 1 >>
8
g
¦
mg
UNIT 2 >>
8
g
¦
mg
NO
KEY BEEP >>
8
MED
HIGH
OFF
LOW
STAB.BEEP>>
8
MED
HIGH
OFF
LOW
RESET
>>
8
NO?
YES?
Interface Menu
Topic Selection
RS232 >>
8
PRINTER >>
8 
PRT.STAB
PRT.AUTO
PRT.ALL
PC-DIR. >>
.
8
PRT.STAB
PRT.AUTO
PRT.ALL
HOST >>
8
SEND.OFF
SEND.STB
SEND.CONT
SEND.AUTO
SEND.ALL
2
.
DISPLAY
¥
HEADER>>
8
NO
DAT/TIM
D/T/B A L
SINGLE>>
8
NET
G/T/N
SIGN.L>>
8
OFF
ON
LINE.FEED>>
8
0
ZERO PRT.>>
8
OFF
ON
COM.SET>>
8
M T- SI C S
M T- P M
SART
BAUDRATE>>
8
9600
¦
4800
BIT/PAR
.
>>
8
8/NO
7/NO
7/MARK
7/SPACE
7/EVEN
7/ODD
S T O P BI T
>>
8
1 BI T
2 BI T S
HD
.
SHAKE>>
8
XON/XOFF
RTS/CTS
OFF
RS.TX.E.O.L.>>
8
<CR><LF>
<CR>
<LF>
<TAB>
RS CHAR >>
8
IBM/DOS
ANSI/WIN
USB >>
8
PC-DIR. >>
.
8 
PRT.STAB
PRT.AUTO
PRT.ALL
HOST >>
8
SEND.OFF
SEND.STB
SEND.CONT
SEND.AUTO
SEND.ALL
USB COM.S.>>
8
M T- SI C S
M T- P M
SART
USB E.O.L.>>
8
<CR><LF>
<CR>
<LF>
<TAB>
USB CHAR>>
8
ANSI/WIN
IBM/DOS
INTERVAL>>
8
0 s
ERGOSENS>>
8
OFF
>0<
>T<
PRINT
Legend
Factory setting
Only those weight units allowed by the appropriate
national legislation are selectable.
Not available with approved models.
¥
Settings are automatically set for the 2
nd
display.
Software version V2.20
For more information
60038400
  • Page 1 1