Hirschmann OCTOPUS II User manual

Type
User manual
Installation Octopus II
Release
08
08/2019
Technical support
https://hirschmann-support.belden.com
User Manual
Installation
Managed IP65/67 Switch
Octopus II
22.8.19
Installation Octopus II
Release
08
08/2019
The naming of copyrighted trademarks in this manual, even when not specially indicated, should
not be taken to mean that these names may be considered as free in the sense of the trademark
and tradename protection law and hence that they may be freely used by anyone.
© 2019 Hirschmann Automation and Control GmbH
Manuals and software are protected by copyright. All rights reserved. The copying, reproduction,
translation, conversion into any electronic medium or machine scannable form is not permitted,
either in whole or in part. An exception is the preparation of a backup copy of the software for
your own use.
The performance features described here are binding only if they have been expressly agreed
when the contract was made. This document was produced by Hirschmann Automation and
Control GmbH according to the best of the company's knowledge. Hirschmann reserves the right
to change the contents of this document without prior notice. Hirschmann can give no guarantee
in respect of the correctness or accuracy of the information in this document.
Hirschmann can accept no responsibility for damages, resulting from the use of the network
components or the associated operating software. In addition, we refer to the conditions of use
specified in the license contract.
You can get the latest version of this manual on the Internet at the Hirschmann product site
(www.hirschmann.com).
Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany
Installation Octopus II
Release
08
08/2019
3
Contents
Safety instructions 5
About this manual 13
Key 14
1 Description 15
1.1 General description 15
1.2 Device name and product code 15
1.3 Device view 22
1.4 Power supply 25
1.4.1 Supply voltage with the characteristic value BB 25
1.4.2 Supply voltage with the characteristic value FF 25
1.4.3 Supply voltage with the characteristic value HH 25
1.4.4 Supply voltage with the characteristic value M9 25
1.4.5 Supply voltage with the characteristic value N9 25
1.4.6 Supply voltage with the characteristic value QQ 26
1.4.7 Supply voltage with the characteristic value PP 26
1.5 Ethernet ports 26
1.5.1 Twisted pair 26
1.5.2 Support of PoE(+) 27
1.5.3 Optical fiber 29
1.5.4 Pin assignments 30
1.6 Display elements 31
1.6.1 Device state 31
1.6.2 Port status 32
1.7 Management interfaces 32
1.7.1 USB interface 32
1.7.2 V.24 interface (external management) 33
1.8 Signal contact 34
2 Installation 35
2.1 Checking the package contents 35
2.2 Installing and grounding the device 35
2.2.1 Installing the device 35
4
Installation Octopus II
Release
08
08/2019
2.2.2 Grounding the device 36
2.3 Connecting the ferrite 37
2.4 Connecting the power supply and the signal contact lines 37
2.4.1 Supply voltage with the characteristic value BB 37
2.4.2 Supply voltage with the characteristic value FF 39
2.4.3 Supply voltage with the characteristic value HH 39
2.4.4 Supply voltage with the characteristic value M9 40
2.4.5 Supply voltage with the characteristic value N9 40
2.4.6 Supply voltage with the characteristic value QQ 42
2.4.7 Supply voltage with the characteristic value PP 42
2.4.8 Signal contact 44
2.5 Operating the device 44
2.6 Connecting data cables 45
2.7 Filling out the inscription label 45
3 Making basic settings 46
4 Monitoring the ambient air temperature 47
5 Maintenance and service 48
6Disassembly 49
7 Technical data 50
A Further support 65
Installation Octopus II
Release
08
08/2019
5
Safety instructions
General safety instructions
You operate this device with electricity. Improper usage of the device
entails the risk of physical injury or significant property damage. The
proper and safe operation of this device depends on proper handling
during transportation, proper storage and installation, and careful
operation and maintenance procedures.
Before connecting any cable, read this document, and the safety
instructions and warnings.
Operate the device with undamaged components exclusively.
The device is free of any service components. In case of a damaged
or malfunctioning device, turn off the supply voltage and return the
device to Hirschmann for inspection.
Qualification requirements for personnel
Only allow qualified personnel to work on the device.
Qualified personnel have the following characteristics:
Qualified personnel are properly trained. Training as well as practical
knowledge and experience make up their qualifications. This is the
prerequisite for grounding and labeling circuits, devices, and systems
in accordance with current standards in safety technology.
Qualified personnel are aware of the dangers that exist in their work.
Qualified personnel are familiar with appropriate measures against
these hazards in order to reduce the risk for themselves and others.
Qualified personnel receive training on a regular basis.
Installation site requirements
Exclusively for device variants featuring supply voltage with
characteristic value M9 or N9:
Install this device solely in a switch cabinet or in an operating site with
restricted access, to which maintenance staff have exclusive access.
WARNING
UNCONTROLLED MACHINE ACTIONS
To avoid uncontrolled machine actions caused by data loss, configure all
the data transmission devices individually.
Before you start any machine which is controlled via data transmission, be
sure to complete the configuration of all data transmission devices.
Failure to follow these instructions can result in death, serious injury,
or equipment damage.
6
Installation Octopus II
Release
08
08/2019
Certified usage
Use the product only for the application cases described in the
Hirschmann product information, including this manual.
Operate the product only according to the technical specifications.
See “Technical data” on page 50.
Connect to the product only components suitable for the requirements
of the specific application case.
Requirements for connecting electrical wires
Before connecting the electrical wires, always verify that the
requirements listed are complied with.
Requirements for connecting the signal contact
Before connecting the signal contact, always verify that the requirements
listed are complied with.
Requirements for connecting the grounding
Before connecting the grounding, always verify that the requirements
listed are complied with.
All of the following requirements are complied with:
The electrical wires are voltage-free.
The cables used are permitted for the temperature range of the application case.
Table 1: Requirements for connecting electrical wires
All of the following requirements are complied with:
The voltage connected complies with the requirements for a safety extra-low voltage
(SELV) as per IEC/EN 60950-1.
The connected voltage is limited by a current limitation device or a fuse.
Observe the electrical threshold values for the signal contact.
See “General technical data” on page 50.
Table 2: Requirements for connecting the signal contact
Device variant Requirements
Only for device variants
featuring supply voltage with
characteristic value M9:
The wire diameter of the ground conductor in the power supply
cable is the same size as or bigger than the wire diameter of the
power supply cables, however of at least 0.75 mm² (AWG18).
All variants The wire diameter of the ground conductor is at least 1.5 mm² at
the device casing. When connecting the provided cable lug, use
a professional crimping tool specified for the wire size. Follow the
instructions of the crimping tool. The pull out force of the crimped
connection is at least 135 N according to the technical standard
IEC 60352-2.
Table 3: Requirements for connecting the grounding
Installation Octopus II
Release
08
08/2019
7
Requirements for connecting the supply voltage
Before connecting the supply voltage, always verify that the requirements
listed are complied with.
Device variant Requirements
All variants All of the following requirements are complied with:
The supply voltage corresponds to the voltage specified on the type
plate of the device.
The power supply conforms to overvoltage category I or II.
The power supply has an easily accessible disconnecting device (for
example a switch or a plug). This disconnecting device is clearly
identified. So in the case of an emergency, it is clear which
disconnecting device belongs to which power supply cable.
Relevant for North America:
The power supply cables are suitable for ambient air temperatures of
at least 167 °F (75 °C). The power supply cable wires are made of
copper.
Exclusively for
device variants
featuring supply
voltage with
characteristic
value BB, FF, HH,
QQ:
The power supply cable is suitable for the voltage, the current and the
physical load. Hirschmann recommends a wire diameter of 0.5 mm² to
0.75 mm² (AWG20 up to AWG18).
The following requirements are alternatively complied with:
Alternative 1 The power supply complies with the requirements
for a limited power source (LPS) as per EN 60950-1.
Alternative 2 Relevant for North America:
The power supply complies with the requirements
according to NEC Class 2.
Alternative 3 All of the following requirements are complied with:
The power supply complies with the
requirements for a safety extra-low voltage
(SELV) as per IEC/EN 60950-1.
A fuse suitable for DC voltage is located in the
plus conductor of the power supply.
The minus conductor is on ground potential.
Otherwise, a fuse is also located in the minus
conductor.
Regarding the properties of this fuse:
See “General technical data” on page 50.
Table 4: Requirements for connecting the supply voltage
8
Installation Octopus II
Release
08
08/2019
Supply voltage
The supply voltage is connected to the device casing through protective
elements exclusively.
Only for device
variants featuring
supply voltage with
characteristic
value M9:
All of the following requirements are complied with:
A fuse is located in the outer conductor of the power supply.
The neutral conductor is on ground potential at both voltage inputs.
Otherwise, a fuse is also located in the neutral conductor.
Regarding the properties of this fuse:
See “General technical data” on page 50.
The power supply cable is suitable for the voltage, the current and the
physical load. The wire diameter is at least AWG18 (0.75 mm²).
Only for device
variants featuring
supply voltage with
characteristic
value N9:
All of the following requirements are complied with:
A fuse suitable for DC voltage is located in the plus conductor of the
power supply.
The minus conductor is on ground potential. Otherwise, a fuse is also
located in the minus conductor.
Regarding the properties of this fuse:
See “General technical data” on page 50.
The power supply cable is suitable for the voltage, the current and the
physical load. Hirschmann recommends a wire diameter of 0.5 mm²
to 0.75 mm² (AWG20 up to AWG18).
Exclusively for
device variants
featuring supply
voltage with
characteristic
value PP:
All of the following requirements are complied with:
The power supply cable is suitable for the voltage, the current and the
physical load. The wire diameter is at least AWG18 (0.75 mm²).
The power supply inputs of the Octopus II device must not be
grounded.
The following requirements are alternatively complied with:
Alternative 1
For providing the PoE power, use the power
supply unit PC150/110V/54V, which is available
as accessory.
See “Accessories” on page 63.
Alternative 2
For providing the PoE power, use a suitable
power supply unit with an insulation strength of
2250 V DC between output and input and
between output and casing.
The power supply complies with the
requirements for a safety extra-low voltage
(SELV) as per IEC/EN 60950-1.
A fuse suitable for DC voltage is located in the
positive conductor of the power supply.
Regarding the properties of this fuse:
See “General technical data” on page 50.
Table 5: Requirements for connecting the supply voltage
Device variant Requirements
Table 4: Requirements for connecting the supply voltage
Installation Octopus II
Release
08
08/2019
9
Shielding ground
The overall shield of a connected shielded twisted pair cable is
connected to the ground connection on the metal housing as a
conductor.
Beware of possible short circuits when connecting a cable section
with conductive shielding braiding.
Exclusively for device variants featuring supply voltage with
characteristic value QQ, PP:
The overall shield of a connected power supply cable is connected to
the ground connection on the metal casing as a conductor.
Beware of possible short circuits when connecting a cable section
with conductive shielding braiding.
Grounding the device
Grounding the device is by means of a separate ground connection on the
device.
Ground the device before connecting any other cables.
Disconnect the grounding only after disconnecting all other cables.
Use toothed washers to ensure good electrical conductivity at the
connection.
Device casing
Only technicians authorized by the manufacturer are permitted to open
the casing.
Exclusively for device variants featuring temperature range
characteristic value T:
At ambient air temperatures > 140 °F (+60 °C):
The surfaces of the device housing may become hot. Avoid touching
the device while it is operating.
To preserve the suitability of your device for IP65/67, proceed as
follows:
Remove the provided transport protection caps and the transport
protection screws from the device.
Seal unused sockets and plugs with your desired type of protection
screws which you can order separately.
National and international safety regulations
Verify that the electrical installation meets local or nationally applicable
safety regulations.
10
Installation Octopus II
Release
08
08/2019
E marking
The labeled devices comply with the regulations contained in the following
European directive(s):
Regulation No. 10 of the Economic Commission for Europe of the United
Nations (UN/ECE): Devices with an approval are labeled with the
E type approval mark.
For devices labeled with the E type-approval mark, the following
installation conditions apply:
The product code tells you which properties your device has.
See “Device name and product code” on page 15.
Characteristic value
“Customer-specific version”
Installation conditions
Exclusively for device variants
featuring the characteristic
value customer-specific
version HE (Hirschmann EMV)
No special installation conditions must be taken into
account.
All other variants
The entire 24 V power supply network must be installed up
to the battery with shielded power supply cables.
The shield must be grounded near the battery.
Installation Octopus II
Release
08
08/2019
11
CE marking
The labeled devices comply with the regulations contained in the following
European directive(s):
In accordance with the above-named EU directive(s), the EU conformity
declaration will be at the disposal of the relevant authorities at the
following address:
Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany
www.hirschmann.com
The product can be used in the industrial sector.
Interference immunity: EN 61000-6-2
Emitted interference: EN 55032
Reliability: EN 60950-1
You find more information on technical standards here:
“Technical data” on page 50
Warning! This is a class A device. This device can cause interference in
living areas, and in this case the operator may be required to take
appropriate measures.
Note: The assembly guidelines provided in these instructions must be
strictly adhered to in order to observe the EMC threshold values.
Device variant Directive
All variants 2014/30/EU (EMC)
Directive of the European Parliament and of the Council on the
harmonisation of the laws of the Member States relating to
electromagnetic compatibility.
2011/65/EU and 2015/863/EU (RoHS)
Directive of the European Parliament and of the Council on the
restriction of the use of certain hazardous substances in
electrical and electronic equipment.
Exclusively for device variants
featuring supply voltage with
characteristic value M9 or N9:
2014/35/EU
Directive of the European Parliament and of the Council on the
harmonisation of the laws of the Member States relating to the
making available on the market of electrical equipment
designed for use within certain voltage limits.
12
Installation Octopus II
Release
08
08/2019
LED or laser components
LED or LASER components according to IEC 60825-1 (2014):
CLASS 1 LASER PRODUCT
CLASS 1 LED PRODUCT
FCC note:
This device complies with part 15 of the FCC rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference; (2) this device must accept any interference received,
including interference that may cause undesired operation.
Appropriate testing has established that this device fulfills the
requirements of a class A digital device in line with part 15 of the FCC
regulations.
These requirements are designed to provide sufficient protection against
interference when the device is being used in a business environment.
The device creates and uses high frequencies and can also radiate these
frequencies. If it is not installed and used in accordance with this
operating manual, it can cause radio transmission interference. The use
of this device in a residential area can also cause interference, and in this
case the user is obliged to cover the costs of removing the interference.
Recycling note
After usage, this device must be disposed of properly as electronic waste,
in accordance with the current disposal regulations of your county, state,
and country.
Installation Octopus II
Release
08
08/2019
13
About this manual
The “Installation” user manual contains a device description, safety
instructions, a description of the display, and the other information that you
need to install the device.
Documentation mentioned in the “User Manual Installation” that is not
supplied with your device as a printout can be found as PDF files for
downloading on the Internet at: https://www.doc.hirschmann.com
14
Installation Octopus II
Release
08
08/2019
Key
The symbols used in this manual have the following meanings:
Listing
Work step
Subheading
Installation Octopus II
Release
08
08/2019
15
1 Description
1.1 General description
The device is designed for the special requirements of industrial automation.
The device meets the relevant industry standards, provides very high
operational reliability, even under extreme conditions, and also long-term
reliability and flexibility.
You have numerous options of combining the device characteristics. You can
determine the possible combinations using the Configurator which is
available in the Belden E-Catalog (www.e-catalog.beldensolutions.com) on
the web page of the device.
The devices comply with the degrees of protection IP65/67.
The devices work without a fan.
The redundancy concept allows the network to be reconfigured quickly.
There are convenient options for managing the device. Manage your devices
via:
Web browser
SSH
Telnet
V.24 interface (locally on the device)
HiDiscovery (software for putting the device into operation)
Network management software (for example Industrial HiVision)
The Network Management Software Industrial HiVision provides you with
options for smooth configuration and monitoring. You find further
information on the Internet at the Hirschmann product pages:
http://www.hirschmann.com/en/QR/INET-Industrial-HiVision
1.2 Device name and product code
The device name corresponds to the product code. The product code is
made up of characteristics with defined positions. The characteristic values
stand for specific product properties.
16
Installation Octopus II
Release
08
08/2019
Item Characteristic Characteri
stic value
Description
1 ... 2 Product OS Octopus II device
3 Data rate 2 Fast Ethernet ports
3 Fast Ethernet ports and Gigabit Ethernet ports
4 Hardware type 0 Standard
4 Standard with PoE(+)
5 (hyphen)
6 ... 7 Number
PoE(+) ports
00 0 × PoE(+) ports
08 8 × PoE(+) ports
10 10 × PoE(+) ports
11 11 × PoE(+) ports
12 12 × PoE(+) ports
14 14 × PoE(+) ports
15 15 × PoE(+) ports
8 ... 9 Number
Fast Ethernet ports
08 8 × Fast Ethernet ports
12 12 × Fast Ethernet ports
16 16 × Fast Ethernet ports
20 20 × Fast Ethernet ports
24 24 × Fast Ethernet ports
28 28 × Fast Ethernet ports
10 ... 11 Number
Gigabit Ethernet ports
00 0 × Gigabit Ethernet ports
02 2 × Gigabit Ethernet ports
04 4 × Gigabit Ethernet ports
12 ... 13 Configuration of uplink
ports 1 and 2
T5 10/100 Mbit/s twisted pair port
4-pin, “D”-coded M12 socket
R5 10/100 Mbit/s twisted pair port
4-pin, „D“-coded M12 socket with bypass relay
T6 10/100/1000 Mbit/s twisted pair port
8-pin, “X”-coded M12 socket
R6 10/100/1000 Mbit/s twisted pair port
8-pin, “X”-coded M12 socket with bypass relay
99 Not present
You will find the information on the F/O ports in a separate
overview.
See table 8 on page 20.
14 ... 15 Configuration of uplink
ports 3 and 4
T5 10/100 Mbit/s twisted pair port
4-pin, “D”-coded M12 socket
R5 10/100 Mbit/s twisted pair port
4-pin, „D“-coded M12 socket with bypass relay
T6 10/100/1000 Mbit/s twisted pair port
8-pin, “X”-coded M12 socket
R6 10/100/1000 Mbit/s twisted pair port
8-pin, “X”-coded M12 socket with bypass relay
You will find the information on the F/O ports in a separate
overview.
See table 8 on page 20.
16 ... 17 Configuration of the
local ports
T5 10/100 Mbit/s twisted pair port
4-pin, “D”-coded M12 socket
Table 6: Device name and product code
Installation Octopus II
Release
08
08/2019
17
18 (hyphen)
19 Temperature range V Standard 40 °F ... +140 °F
(40 °C ... +60 °C)
T Extended 40 °F ... +158 °F
(40 °C ... +70 °C)
20 ... 21 Supply voltage BB 2 voltage inputs for redundant power supply
Rated voltage
24 V DC
Connection type 5-pin M12 connector
HH 2 voltage inputs for redundant power supply
Rated voltage range
36 V DC ... 48 V DC
Connection type 5-pin M12 connector
FF 2 voltage inputs for redundant power supply
Rated voltage range
24 V DC ... 48 V DC
Connection type 5-pin 7/8" plug
M9 1 voltage input
Rated voltage range
110 V AC ... 230 V AC, 50 Hz ... 60 Hz
Connection type 3-pin, 7/8" connector
N9 1 voltage input
Rated voltage range
72 V DC ... 110 V DC
Connection type 4-pin, 7/8" connector
QQ 2 voltage inputs for redundant power supply
Rated voltage range
24 V DC ... 48 V DC
Connection type 4-pin, “T”-coded M12
power plug
PP PoE 2 voltage inputs for redundant power
supply
Rated voltage range
47 V DC ... 57 V DC
PoE
Plus
2 voltage inputs for redundant power
supply
Rated voltage range
53 V DC ... 57 V DC
Connection type 4-pin, “T”-coded M12
power plug
22 ... 23 Certificates and
declarations
You will find detailed information on the certificates and
declarations applying to your device in a separate overview.
See table 7 on page 19.
24 ... 25 Software packages 99 Reserved
Item Characteristic Characteri
stic value
Description
Table 6: Device name and product code
P
++
18
Installation Octopus II
Release
08
08/2019
26 ... 27 Customer-specific
version
HH Hirschmann standard
HA Hirschmann Angled
H1 Hirschmann Power Supply Side
HE Hirschmann EMV
28 Hardware
configuration
S Standard
M Ports 1 and 2: Fast MRP
P Ports 1 and 2: PRP
H Ports 1 and 2: HSR
D Ports 1 and 2: DLR
N Ports 1 and 2: 1:1 NAT
T Ports 1 ... 4: Train backbone (ETB)
29 Software configuration E Entry (without configuration)
DDLR
P PROFINET/IO
I Ethernet/IP
BBDEW
30 ... 31 Software level 2S HiOS Layer 2 Standard
2A HiOS Layer 2 Advanced
3S HiOS Layer 3 Standard
32 ... 36 Software version 04.1. Software-Version 04.1
XX.X. Current software version
37 ... 38 Maintenance 00 Bugfix version 00
XX Current bugfix version
Item Characteristic Characteri
stic value
Description
Table 6: Device name and product code
Installation Octopus II
Release
08
08/2019
19
Application case Certificates and declarations Characteristic value
Z9 Y9 U9 UY UT US T9 TY S9 SY R9
Standard applications CE X X X X X X X X X X X
EN 60950-1 X X X X X X X X X X X
EN 61131-2 X X X X X X X X X X X
FCC X X X X X X X X X X X
cUL 60950-1 X X X X X X
Navy applications DNV GL X X X X
Railway applications
(trackside)
EN 50121-4 X X X X X X
Railway applications (in
vehicles)
EN 50155 X X X
Motor vehicle applications E1 X
Table 7: Assignment: application cases, certificates and declarations, characteristic values
20
Installation Octopus II
Release
08
08/2019
Port type Built-in transceivers Version Characteristic value
1M 1S 1P 1L 1A 1B 1C 1D 4M 4S 4P 4L 4A 4B 4C 4D 5M 5S 5P 5L 5A 5B 5C 5D
1000 Mbit/s
F/O port
M-SFP-SX/LC-EEC V1 X
V4 X
QODC X
M-SFP-LX/LC-EEC V1 X
V4 X
QODC X
M-SFP-LH/LC-EEC V1 X
V4 X
QODC X
M-SFP-LH+/LC EEC V1 X
V4 X
QODC X
Table 8: Description of the characteristic values for uplink ports 1 and 2 / uplink ports 3 and 4 in F/O types
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66

Hirschmann OCTOPUS II User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI