DLED8 INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding
is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining xture.
SAFETY INSTRUCTIONS
WARNING – Risk of re or electric shock. LED Retrot Kit installation requires knowledge of luminaires electrical systems.
If not qualied, do not attempt installation. Contact a qualied electrician.
WARNING – Risk of re or electric shock. Install this kit only in the luminaires that have the construction features and
dimensions shown in the photographs and/or drawings.
WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
WARNING - Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit
installation. Do not leave any other open holes in an enclosure of wiring or electrical components.
WARNING - Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
EXISTING MOUNTING FRAME
DLED8 is suitable for installation in Non-Insulated Ceilings.
Insulation not to be placed over the top of or within 3” of
DLED8.
DLED8 can be used in Existing Mounting Frames with
opening of minimum 7-7/8” (200mm) and maximum of
8-7/8” (225.4mm).
1. Disconnect power to the Existing Fixture (Fig. 1).
2. Remove/ detach existing reector, Socket Cap, Yoke
or any obstruction above ceiling within Existing
Mounting Frames as shown in Fig. 2 to allow
installation of the DLED8 and to have access to Junction
Box.
Note - Height of DLED8 is 8-3/4” (222.3mm).
3. Open access plate on Junction Box and disconnect
power connections.
Fig.1. Existing Fixture
Socket Cap
YokeJunction Box
Fig.2. Remove/ Detach all obstructions
Existing
Mounting Frame
Existing
Mounting Frame