FEATURES
• Lightcomesonwhenmotionisdetected.
• Automaticallyturnslightoff.
• HalfpowerAccentlighting.
• Photocell keeps the light off during daylight
hours.
REQUIREMENTS
• Thelightcontrolrequires120voltsAC.
• IfyouwanttouseManualMode,thecontrolmust
bewiredthroughaswitch.
• Some electrical codes require installation by
a qualified electrician.
Diecast Motion
Sensing Porch Light
Thispackageincludes:
• PorchLight
• EasytouseUniversalMountingBracket
• MountingHardware
• WireNuts
• LensShield
Model4300
©2012HeathCoLLC 204062-01A
Mode: On-Time Works: Day Night
Test 5Seconds x x
Auto/ 1,5,or10minutes x
AccentOff,3,6Hr,toDawn x
Manual UntilDawn* x
OPERATION
Note: Whenrstturnedonwaitabout1
1
/
2
minutes
forthecircuitrytocalibrate.
*resetstoAutoModeatdawn.
ON-TIME
TEST 1 510MIN
TEST
SetON-TIMEswitchto
1,5,or10minutes.
AUTO
ON-TIME Switch at 1, 5, or
10 minutes
...backon.
1Second
OFFthen...
Manual mode only works at
nightbecausedaylightreturns
thesensortoAUTO.
Flipthelightswitchoffforone
secondthenbackontotoggle
betweenAUTOandMANUAL
MODE.
Manualmodeworksonlywith
theON-TIMEswitchinthe1,
5,or10position.
MODE SWITCHING SUMMARY
Flip light switch off
for one second then
back on*
*Ifyougetconfusedwhileswitchingmodes,turnthe
poweroffforoneminute,thenbackon.Afterthecali-
brationtimethecontrolwillbeintheAUTOmode.
MANUAL MODE
AUTO
TEST
MANUAL MODE
ON-TIME
TEST 1 5 10 MIN
Before installation, record the model number
listed inside the fixture. Attach receipt in case
of possible warranty issues.
Model Number:
SettheON-TIMEswitch
onthesensortoTEST.
2
204062-01
DUAL BRITE
®
ON-TIME
TEST 1 5
1
0 MIN
OFF 3 6
DUSK
TO DAWN
DUAL BRITE
®
ON-TIME
TEST 1 5 10 MIN
OFF 3 6
DUSK
TO DAWN
INSTALL UNIVERSAL MOUNTING
BRACKET
Forbestperformance,mountthextureatleast
8feet(2.4m)abovetheground.
FixtureScrew(Tightened
FingerTight)
JunctionBox
UniversalMounting
Bracket
JunctionBoxScrew
WIRING LIGHT FIXTURE
1. Connectthejunctionboxwiresandthexture
wirestogetherasshowninthefollowingdia-
grams.
CAUTION: DO NOT remove wire connec-
tor from RED wire or connect the RED wire
unless you want to control other lights from
this motion sensor fixture.
DISASSEMBLE LIGHT FIXTURE
1. Removetwodecorativenutsfromlightxture
cover.
2. Removecoverfrombase.
3. Removetwodecorativenutsfromxturescrews
inuniversalmountingbracket.
4. Remove universal mounting bracket from
base.
DecorativeNut
LightFixtureBase
LightFixtureCover
DecorativeNut
Universal
Mounting
Bracket
Note:Ifyouhaveametaljunctionboxusetherecom-
mendedgroundingmethodshowninthefollowing
illustration.Ifyouareuncertainaboutthegrounding
method,consultyourlocalbuildingcode.
2. Twistandsecurewireswithwirenuts.
DualBrite
®
DIMMER CONTROL
Lightcomesonhalfbrightforselectedtimeafterdusk
(Off,3hr.,6hr.,untildawn).SelectingOFFdisablesthis
feature.Themotionsensingfeatureswillcontinueto
workasdescribedinthismanual.Ifmotionissensed,
thelightturnsonfullbrightfortheON-TIME(1,5,or
10minutes)thenreturnstodimmode.
WARNING: Turn power off at circuit
breaker or fuse.
1. Tightenthetwoxturescrewsngertight.
2. Attachuniversalmountingbrackettojunction
boxsecurelywiththetwoscrewsprovided.
3
204062-01
GroundScrew
WhitetoWhite
BlacktoBlack
Recommended Grounding Method
One Motion Sensing Light
Two Motion Sensing Lights (Working Independently)
Other Wiring Options
Thisxturecanbewiredtocontrolanotherstandard
ormotionsensinglightxture(s).Seethefollowing
wiringdiagramsforproperconnections.
Note:Allwiringshouldberuninaccordancewith
the National Electrical Codethroughconduit or
anotheracceptablemeans.Contact a qualified
electrician if there is any question as to the
suitability of the system.
BlacktoBlack
WhitetoWhite
Ground
toGround
BlacktoBlack
WhitetoWhite
GroundtoGround
MetalJunction
Box
Pigtail(not
supplied)
FixtureBare
GroundWire
BareGroundWire
Wiring Motion Sensing Light to Control Standard
Fixture
Groundto
Ground
StandardLightFixtureMotionSensingLight
BlacktoBlack
WhitetoWhite
RedtoBlack
Maximum Load for
Motion Sensor –
200 Watts
Maximum Lamp
Wattage Rating
for Light Fixture –
100 Watts
Maximum Lamp
Wattage Rating
for Light Fixture –
100 Watts
TOTAL Load for
Motion Sensor –
200 Watts
CONTROLLING Fixture
CONTROLLED Fixture 1
Whencontrollinganadditionallightxture(s),the
maximumwattageofthemotionsensoron this
xtureshouldbeobserved.Seeillustrationbelow
foranexampleofamaximumlampwattageload
calculation.
IMPORTANT: When determining the maximum
lampwattageratingofthexturetobecontrolled,
refertothemaximumlampwattagelabelonthe
xtureandnotthewattageratingonthelamp(s)
currentlyinstalledinthexture.
Wiring Motion Sensing Light to Control Another
Motion Sensing Light
BlacktoBlack
WhitetoWhite
GroundtoGround
BlacktoRed
and Black
RedtoBlack
ControlledMotion
SensingLight
MotionSensingLight
4
204062-01
TESTING
1. Turn on the circuit breaker and light switch.
Note:Sensorhasa1
1
/
2
minutewarmupperiod
beforeitwilldetectmotion.Whenrstturnedon
wait1
1
/
2
minutes.
2. SettheON-TIMEswitchtotheTESTposition
andtheDualBrite
®
switchtotheOFFposition.
3. Walkthroughthecoverageareanotingwhere
youarewhenthelightsturnon.InTESTmode,
lightwillstayonforonly5secondsthenturn
off.
4. AdjusttheSENSITIVITYtoincreaseordecrease
therangeasneeded.Toomuchsensitivitymay
causefalsetriggeringduetoheatsourcesinthe
coverage area (see Adjustment of Coverage
AreaorTroubleshootingsection).
Itisalsopossibletowiretwomotionsensinglights
sothateitherunitwillturnonbothlightsatthesame
time(dualcontrolledsystem).Itisrecommendedthat
onlypeoplewithelectricalwiringexperienceattempt
thisconguration.Pleasecallourcustomerservice
number (1-800-858-8501) before attempting this
wiring.If the dual controlled wiring is not done
correctly, it can destroy both motion sensing
fixtures and void your warranty.
INSTALL FIXTURE BASE TO
JUNCTION BOX
1. Pushwiresintothejunctionbox.
2. Slide lightxture base onto xture screwsand
tightendecorativenutssnuglyagainstthebase.
3. Install four candelabra base light bulbs (25
Watts maximum each).
4. Refer to TESTING section before installing
cover.
5. Afterswitchesaresetandtestingiscomplete,
usethe2decorativenutstoinstallthecover.
DUAL BRITE
®
ON-TIME
TEST 1
5 10 MIN
OFF 3 6
DUSK
TO DAWN
DualBrite
®
ON-TIME
DUSK
OFF
3
HR 6HR TO DAWN
TEST 1 5 10 MIN
Sensor
Lens
5. SettheamountofON-TIMEyouwantthelight
tostayonaftermotionisdetected(1,5,or10
minutes).
6. Settheamountoftimeyouwantthelightto
stayonintheAccentmode(Off,3hours,6
hours,ordusk-to-dawn).
SENSITIVITY
+
+
SENSITIVITY
FixtureScrew
JunctionBox
DecorativeNut
25WattCandelabra
BaseBulb
Maximum Range Coverage Angle*
(Top View)
360°
30Feet(9.1m)
inallDirections
*Withoutlensshieldinstalled.
8ft.(2.4m)
5
204062-01
Least Sensitive Most Sensitive
The sensor is less sensitive to motion directly
towardsit and moresensitive to motion across
coveragearea.
Sensor
Motion
Motion
SPECIFICATIONS
Range...........................Upto30ft.(9.1m)
[varieswithsurrounding
temperature].
SensingAngle.............. 360°
ElectricalLoad..............Upto100Watt
MaximumTungsten
Incandescent(Upto25
WattMaximumeach
lampholder).
BulbType...................... CandelabraBase,Type
“B”,25WattMaximum
SensorCapacity...........Upto200Watt(1.7A.)
MaximumTungsten
Incandescent
PowerRequirements.... 120VAC,60Hz
OperatingModes..........TEST,AUTO/ACCENT,
andMANUALMODE
ON-Timer......................1,5,10minutes
DualBrite
®
Timer..........Off,3,6Hrs,Dusk-to-
Dawn
HeathCo LLC reserves the right to discontinue
productsandtochangespecicationsatanytime
withoutincurringanyobligationtoincorporatenew
featuresinproductspreviouslysold.
ADJUSTMENT OF COVERAGE
AREA
Thesensor onthis light xturedetects“motion”
bythemovementofheat(bodyheat)acrossthe
coveragearea.However,followingareexamples
ofobjectsthatalsoproduceheatandcancause
thesensortofalsetrigger:
•PoolsofWater •AirConditioners
•DryerVents •Fenced-InAnimals
•HeatingVents •AutomobileTrafc
Ifyoususpectthataheatsourceofthistypeisfalsely
triggeringthesensorandreducingthesensitivity
does not solve the problem, then a lens shield
(included)can be installed.Theplasticlensshield
isdividedinto6sections.Eachsectionwillreducethe
coverageangleby30degrees.Also,thetipofeach
sectionmaybe removedtochange the effective
rangeofthesensor.
1. Break off the
amountoflens
shield needed
toblockthede-
sired area of
coverage.
2. Cut desired
amountoffoam
tapeneededto
adherethelens
shieldtothesensorlens.
3. Removepaperbackingfromonesideofcut
foamtapeandadherefoamtapetoinsideof
lensshield.
4. Removepaperbackingfromothersideofcutfoam
tapeandadherelensshieldtosensorlens.
5. Retesttoconrmthatthesensorisnolonger
falsetriggering.
Note:To help determine amount of lens shield
required,applysmallsectionsoneatatime.Ad-
ditionalsectionscanbeappliedifnecessary.
Area
Blocked
Area
Blocked
Lens
Shield
Lens
Shield
Portion
Removed
Effective
CoverageArea
(TopView)
LensShield
SensorLens
DUAL BRITE
®
ON-
TIME
TEST 1 5 10 MIN
OFF 3 6
DUSK
TO DAWN
6
204062-01
SYMPTOM
Light stays on
continuously.
Light flashes on
and off.
Light does not
stay on in Man-
ual mode.
POSSIBLE CAUSE
1.
Thereisaheatsourcelikeanair
vent,dryervent,orbrightly-painted,
heat-reectivesurfaceinthecover-
agearea.(Install shield on sensor
in the direction of heat source.)
2. LightcontrolisinManualMode.
(Switch to Auto.)
3. Light control is in DualBrite
®
mode.
4. Sensitivityissettoohigh.(Reduce
sensitivity.)
1. SensorisintheTestmode.(While
in TEST mode, light only stays on
for 5 seconds.)
1. Nearbylarge,light-coloredobjects
reecting light may trigger the
shut-offfeature.Donotpointother
lightsatthesensor.
POSSIBLE CAUSE
1. Lightswitchisturnedoff.
2. Bulbsarelooseorburnedout.
3. Fuseisblownorcircuitbreaker
isturnedoff.
4. Daylightturn-offisineffect(re-
check after dark).
5. Incorrectcircuitwiring,ifthisis
anewinstallation.
1. Sensor may be installed in a
relativelydarklocation.
2. Sensor is in Test. (Set control
switch to an ON-TIME position.)
1. Sensor may be sensing small
animals or automobile traffic.
(Reduce sensitivity.)
SYMPTOM
Light will not
come on.
Light comes on
in daylight.
Light comes on
for no apparent
reason.
TROUBLESHOOTING GUIDE
TWO YEAR LIMITED WARRANTY
Thisisa“LimitedWarranty”whichgivesyouspeciclegalrights.Youmayalsohaveotherrightswhichvaryfromstateto
stateorprovincetoprovince.
Foraperiodoftwoyearsfromthedateofpurchase,anymalfunctioncausedbyfactorydefectivepartsorworkmanship
willbecorrectedatnochargetoyou.
Not Covered - Repairservice,adjustmentandcalibrationduetomisuse,abuseornegligence,lightbulbs,batteries,and
otherexpendableitemsarenotcoveredbythiswarranty.Unauthorizedserviceormodicationoftheproductorofany
furnishedcomponentwillvoidthiswarrantyinitsentirety.Thiswarrantydoesnotincludereimbursementforinconvenience,
installation,setuptime,lossofuse,unauthorizedservice,orreturnshippingcharges.
ThiswarrantycoversonlyHeathCoLLCassembledproductsandisnotextendedtootherequipmentandcomponentsthat
acustomerusesinconjunctionwithourproducts.
THISWARRANTYISEXPRESSLYINLIEUOFALLOTHERWARRANTIES,EXPRESSORIMPLIED,INCLUDINGANY
WARRANTY,REPRESENTATIONORCONDITIONOFMERCHANTABILITYORTHATTHEPRODUCTSAREFITFOR
ANYPARTICULARPURPOSEORUSE,ANDSPECIFICALLYINLIEUOFALLSPECIAL,INDIRECT,INCIDENTAL,OR
CONSEQUENTIALDAMAGES.
REPAIRORREPLACEMENTSHALLBETHESOLEREMEDYOFTHECUSTOMERANDTHERESHALLBENOLIABILITY
ONTHEPARTOFHEATHCOLLCFORANYSPECIAL,INDIRECT,INCIDENTAL,ORCONSEQUENTIALDAMAGES,
INCLUDINGBUTNOTLIMITEDTOANYLOSSOFBUSINESSORPROFITS,WHETHERORNOTFORESEEABLE.Some
statesorprovincesdonotallowtheexclusionorlimitationofincidentalorconsequentialdamages,sotheabovelimita-
tionorexclusionmaynotapplytoyou.Please keep your dated sales receipt, it is required for all warranty requests.
TECHNICAL SERVICE
Please call 1-800-858-8501 (English speaking only) for assistance before returning
product to store.
Ifyouexperienceaproblem,followthisguide.YoumayalsowanttovisitourWebsiteat:www.hzsupport.
com.Iftheproblempersists,call*forassistanceat1-800-858-8501(Englishspeakingonly),8:00AMto
5:00PMCST(M-F).Youmayalsowrite*to:
HeathCoLLC
P.O.Box90045,BowlingGreen,KY42102-9045
ATTN:TechnicalService
*IfcontactingTechnicalService,pleasehavethefollowinginformationavailable:ModelNumber,Dateof
Purchase,andPlaceofPurchase.
No Service Parts Available for this Product
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Heath Zenith HZ-4300-BK User manual

Category
Work lights
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI