ENGLISH
VERSO, VERSO COMPACT,
VERSO POLAR
Side-opening polycarbonate camera housing
EN
English - Instruction manual
ENGLISH
VERSO, VERSO COMPACT,
VERSO POLAR
Side-opening polycarbonate camera housing
Contents
ENGLISH 1
1 About this manual ....................................................................................................................5
1.1 Typographical conventions ................................................................................................................................................ 5
2 Notes on copyright and information on trademarks .............................................................5
3 Safety rules................................................................................................................................5
4 Identication .............................................................................................................................7
4.1 Product description and type designation ................................................................................................................... 7
4.1.1 VERSO ...........................................................................................................................................................................................................7
4.1.2 VERSO COMPACT...................................................................................................................................................................................... 7
4.1.3 VERSO POLAR ............................................................................................................................................................................................ 7
4.2 Product marking ..................................................................................................................................................................... 7
5 Preparing the product for use .................................................................................................8
5.1 Unpacking ................................................................................................................................................................................. 8
5.2 Contents .................................................................................................................................................................................... 8
5.3 Safely disposing of packaging material ......................................................................................................................... 8
5.4 Preparatory work before installation............................................................................................................................... 8
5.4.1 Mounting the bracket ............................................................................................................................................................................ 8
6 Installation ................................................................................................................................9
6.1 Housing opening .................................................................................................................................................................... 9
6.2 How to install the camera .................................................................................................................................................... 9
6.3 Board description ................................................................................................................................................................. 10
6.4 Connection of the power supply line ............................................................................................................................12
6.4.1 Type of cable ............................................................................................................................................................................................12
6.5 Installation of the version with double lter for air renewal ................................................................................12
6.6 Desiccant bag ........................................................................................................................................................................12
7 Accessories ..............................................................................................................................13
7.1 Heater .......................................................................................................................................................................................13
7.1.1 Heater installation .................................................................................................................................................................................13
7.2 Camera power supply ......................................................................................................................................................... 13
7.2.1 Camera power supply installation ................................................................................................................................................... 13
7.3 Blower ....................................................................................................................................................................................... 14
7.3.1 Blower installation .................................................................................................................................................................................14
8 Cleaning ..................................................................................................................................14
8.1 Cleaning the window and plastic parts ........................................................................................................................14
9 Information on disposal and recycling .................................................................................14
10 Technical data .......................................................................................................................15
10.1 VERSO ..................................................................................................................................................................................... 15
10.1.1 General ....................................................................................................................................................................................................15
10.1.2 Mechanical ............................................................................................................................................................................................. 15
10.1.3 Electrical .................................................................................................................................................................................................15
10.1.4 Environment..........................................................................................................................................................................................15
10.1.5 Certications .........................................................................................................................................................................................15
10.2 VERSO COMPACT ................................................................................................................................................................16
10.2.1 General ....................................................................................................................................................................................................16
10.2.2 Mechanical ............................................................................................................................................................................................. 16
10.2.3 Electrical .................................................................................................................................................................................................16
10.2.4 Environment..........................................................................................................................................................................................16
10.2.5 Certications .........................................................................................................................................................................................16
10.3 VERSO POLAR ......................................................................................................................................................................17
10.3.1 General ....................................................................................................................................................................................................17
10.3.2 Mechanical ............................................................................................................................................................................................. 17
10.3.3 Electrical .................................................................................................................................................................................................17
10.3.4 Environment..........................................................................................................................................................................................17
10.3.5 Certications .........................................................................................................................................................................................17
11 Technical drawings ...............................................................................................................18
Instruction manual - English - EN
5MNVCHPVB_2024_EN
1 About this manual
Read all the documentation supplied carefully before
installing and using this product. Keep the manual in
a convenient place for future reference.
1.1 Typographical conventions
DANGER!
High level hazard.
Risk of electric shock. Disconnect the
power supply before proceeding with any
operation, unless indicated otherwise.
CAUTION!
Medium level hazard.
This operation is very important for the
system to function properly. Please read
the procedure described very carefully and
carry it out as instructed.
INFO
Description of system specications.
We recommend reading this part carefully
in order to understand the subsequent
stages.
2 Notes on copyright and
information on trademarks
The mentioned names of products or companies are
trademarks or registered trademarks.
3 Safety rules
CAUTION! Device installation and
maintaining must be performed by
specialist technical sta only.
CAUTION! The electrical system to which the unit
is connected must be equipped with an automatic
bipolar circuit breaker. The circuit breaker for main
supply voltage phase units must have a level of
intervention of 20A max. The circuit breaker for low
voltage units must have a level of intervention of
6A max. This circuit breaker must be of the Listed
type. The minimum distance between the circuit
breaker contacts must be 3mm (0.1in). The circuit
breaker must be provided with protection against
the fault current towards the ground (dierential)
and the overcurrent (magnetothermal).
The manufacturer declines all responsibility
for any damage caused by an improper use
of the appliances mentioned in this manual.
Furthermore, the manufacturer reserves the right
to modify its contents without any prior notice.
The documentation contained in this manual has
been collected and veried with great care. The
manufacturer, however, cannot take any liability
for its use. The same thing can be said for any
person or company involved in the creation and
production of this manual.
Before starting any operation, make sure the
power supply is disconnected.
Be careful not to use cables that seem worn or old.
Never, under any circumstances, make any
changes or connections that are not shown in
this handbook. Improper use of the appliance
can cause serious hazards, risking the safety of
personnel and of the installation.
Use only original spare parts. Non-original spare
parts could cause re, electrical discharge or other
hazards.
EN - English - Instruction manual
6 MNVCHPVB_2024_EN
Comply with all the national standards during the
device installation.
This device was designed to be permanently
secured and connected on a building or on a
suitable structure. The device must be permanently
secured and connected before any operation.
Before proceeding with installation, check the
supplied material to make sure it corresponds
to the order specication by examining the
identication labels (4.2 Product marking, page 7).
Any device which could be installed inside the
product must comply with the current safety
standards.
If the installation is NEMA TYPE 4X, the installer
must replace the cable glands of the product with
NEMA TYPE 4X cable glands.
For all connections, use cables that are able to
withstand temperatures of at least 75°C (167°F).
The product is designed to house only cameras
that are properly certied according to IEC/UL
60950-1 or IEC/UL 62368-1 (7W max).
A power disconnect device must be included
in the electrical installation, and it must be very
quickly recognizable and operated if needed.
To connect the power supply line use the
appropriate junction-box (UPTJBUL). For further
information, refer to the product use and
installation manual.
Use Listed tube crimping lugs for the connection
of the network conductors to the terminals. The
copper tube crimping lugs must be suitable for
the type of installation (from -20°C (-4°F) a +80°C
(+176°F) min., V-0). Copper tube crimping lugs
examples: RP, BP o YP (Cembre).
Installation category (also called Overvoltage
Category) species the level of mains voltage
surges that the equipment will be subjected to.
The category depends upon the location of the
equipment, and on any surge voltage protection
provided. Equipment in an industrial environment,
directly connected to major feeders/short branch
circuits, is subjected to Installation Category
III. If this is the case, a reduction to Installation
Category II is required. This can be achieved by
use of an insulating transformer with an earthed
screen between primary and secondary windings,
or by tting UL listed Surge Protective Devices
(SPDs) from live to neutral and from neutral to
earth. Listed SPDs shall be designed for repeated
limiting of transient voltage surges and the
following rated operation conditions: Type 2 (SPDs
permanently connected to the power network and
intended for installation on the load side of the
service equipment); Nominal Discharge Current
(In) 20kA min. For example: FERRAZ SHAWMUT,
STT2240SPG-CN, STT2BL240SPG-CN rated
120Vac/240Vac, (In=20kA). Maximum distance
between installation and reduction is 5m.
Instruction manual - English - EN
7MNVCHPVB_2024_EN
4 Identication
4.1 Product description and type
designation
4.1.1 VERSO
Sturdy, tamper-proof housing designed to simplify
installation and service and guarantee total
protection against all environmental conditions.
Its dimensions make it suitable for a variety of
combinations of cameras and lenses.
Entirely constructed from technopolymer, it
guarantees high impact resistance and perfect
weather protection from external agents and UV rays.
Very easy to install thanks to the side-opening system
that allows the full access to the camera, lenses and
all internal connections.
The housing proposes various mounting options,
wall or ceiling brackets, feedthrough and non-
feedthrough, or Pan & Tilt head.
4.1.2 VERSO COMPACT
Entirely constructed from technopolymer, it
guarantees high impact resistance and perfect
weather protection from external agents and UV rays.
4.1.3 VERSO POLAR
This housing is provided with a high performance
heating system which it will continue working at
even the most severe temperatures, right down to-
55°C (-67°F).
4.2 Product marking
See the label attached to the product.
EN - English - Instruction manual
8 MNVCHPVB_2024_EN
5 Preparing the product for
use
Any change that is not expressly approved
by the manufacturer will invalidate the
guarantee.
5.1 Unpacking
When the product is delivered, make sure that the
package is intact and that there are no signs that it
has been dropped or scratched.
If there are obvious signs of damage, contact the
supplier immediately.
When returning a faulty product we recommend
using the original packaging for shipping.
Keep the packaging in case you need to send the
product for repairs.
5.2 Contents
Check the contents to make sure they correspond
with the list of materials as below:
Housing
Housing equipment:
Allen wrench
Spacers
Cable glands gaskets
Cable glands (x3)
Bolts and screws
Screws for camera
Instruction manual
5.3 Safely disposing of packaging
material
The packaging material can all be recycled. The
installer technician will be responsible for separating
the material for disposal, and in any case for
compliance with the legislation in force where the
device is to be used.
5.4 Preparatory work before
installation
5.4.1 Mounting the bracket
The product must be fastened with suitable
equipment. The fastening means must
guarantee mechanical sealing when a force
equal to at least 4 times the weight of the
device is applied.
Instruction manual - English - EN
9MNVCHPVB_2024_EN
6 Installation
6.1 Housing opening
Loosen the 2 screws on the side, turn the cover and
the upper half of the body about the opening hinge
axis.
Fig. 1
After installation and wiring, close the
product.
6.2 How to install the camera
Open the housing as described in the relative chapter
(6.1 Housing opening, page9).
Partially loosening the fastening screws (01).
Remove the internal slide (02) by sliding it until the
holes coincide with the slide fastening screws.
Fasten the camera with the 1/4" screw (03). To
position the camera and lens correctly, if necessary,
use the supplied spacers. (04).
01
04
02
03
Fig. 2
Reposition the internal slide and tighten the screws
that had been loosened previously.
Remove the conductors protective sheathing and
connect them to terminal (camera power supply, 6.3
Board description, page10).
The cameras power supply cable conductors must be
tied up with a cable tie next to the terminal. Keep the
signalling and power supply cables separated from
each other.
EN - English - Instruction manual
10 MNVCHPVB_2024_EN
6.3 Board description
Connect the safety earth to the relative
terminal of the power supply connector.
The board may appear dierent to that
illustrated.
Depending on the product version, the
board may not be equipped with all
functions.
BOARD DESCRIPTION (VERSO, VERSO COMPACT)
Connector Function
J1 Camera power supply (V
OUT)
Tamper switch contacts
J2 Heater power supply (V
OUT)
J3 Power supply for the board (V
IN)
J4 Auxiliary output (V
OUT)
J5 Power supply connector/jumper
J6 Fan power supply (V
OUT)
SW1 Tamper switch
Tab. 1
1
Dierent alternatives are available depending on the
version. VOUT = 12Vdc o VOUT = 24Vac, in relation to the
type of power supply installed (7.2.1 Camera power
supply installation, page13). VOUT = VIN, only for hou-
sings powered in 12Vdc or 24Vac, with jumper inserted
(J5).
2
Optional. Only available for VERSO housing.
3
From 100Vac a 240Vac, 24Vac o12Vdc.
4
Same voltage applied to power supply terminal of the
board (J3).
5
To install a power supply in 12Vdc or 24Vac refer to the
relative chapter (7.2.1 Camera power supply installa-
tion, page13).
J3J4 J1
J6 SW1
J2
J5
Fig. 3 VERSO.
J4 J1J3 J6
J5J2
Fig. 4 VERSO COMPACT.
Instruction manual - English - EN
11MNVCHPVB_2024_EN
BOARD DESCRIPTION (VERSO, VERSION WITH DOUBLE FILTER FOR
AIR RENEWAL)
Connector Function
J1 Power supply for the board (V
IN)
J2 Auxiliary output (V
OUT)
J3 Heater power supply (V
OUT)
J4 Tamper switch contacts
J5 Camera power supply (V
OUT)
J7 Power supply connector/jumper
J8 Fan power supply (V
OUT)
SW1 Tamper switch
Tab. 2
1
From 100Vac a 240Vac, 24Vac o12Vdc.
2
Same voltage applied to power supply terminal of the
board (J1).
3
Optional.
4
Dierent alternatives are available depending on the
version. VOUT = 12Vdc o VOUT = 24Vac, in relation to the
type of power supply installed (7.2.1 Camera power
supply installation, page13). VOUT = VIN, only for hou-
sings powered in 12Vdc or 24Vac, with jumper inserted
(J7).
5
To install a power supply in 12Vdc or 24Vac refer to the
relative chapter (7.2.1 Camera power supply installa-
tion, page13).
J1 J4J2J8
J7SW1 J3
J5
Fig. 5 VERSO (version with double lter for air renewal).
BOARD DESCRIPTION (VERSO POLAR)
Connector Function
J1, J2, J3 Heater power supply (V
OUT)
J6 Camera power supply (V
OUT)
J7 Power supply for the board (V
IN)
J8 Power supply connector/jumper
J10 Auxiliary output (V
OUT)
Tab. 3
1
Dierent alternatives are available depending on the
version. VOUT = 12Vdc o VOUT = 24Vac, in relation to the
type of power supply installed (7.2.1 Camera power
supply installation, page13). VOUT = VIN, only for hou-
sings powered in 12Vdc or 24Vac, with jumper inserted
(J8).
2
From 100Vac a 240Vac, 24Vac o12Vdc.
3
To install a power supply in 12Vdc or 24Vac refer to the
relative chapter (7.2.1 Camera power supply installa-
tion, page13).
4
Same voltage applied to power supply terminal of the
board (J7).
J6
J10 J7 J1 J2
J3 J8
Fig. 6 VERSO POLAR.
EN - English - Instruction manual
12 MNVCHPVB_2024_EN
6.4 Connection of the power
supply line
Earth cable should be about 10mm longer
than the other two, so that it will not be
disconnected accidentally if pulled.
Insert the cables inside the housing using the cable
glands. The cable glands are suitable for conductors
with diameters of between 5mm and 10mm. The
section of the cable inside the housing must be
suciently long to allow connection. Suitably lock
the cable glands.
Remove the conductors protective sheathing and
connect them to terminal (Power supply for the
board, 6.3 Board description, page10).
6.4.1 Type of cable
The cable used for the connection to the power
supply line must be suitable for the intended use.
Comply with the current national standards on
electrical installations.
6.5 Installation of the version
with double lter for air renewal
During installation pay attention to the
orientation of the air inlet lter ns.
Fig. 7
Depending on the angle of inclination of the housing,
the orientation of the lter ns must prevent water
penetrating in case of rain:
To guarantee weatherproof protection, install the
housing on the support following the inclination
limits as shown in the picture.
45°
45°
Fig. 8 Maximum tilt of the transversal axis: 0°.
Maximum tilt of the longitudinal axis: ±45°.
6.6 Desiccant bag
Take the dessicant salt bag out of its pack and insert it
into the product.
Instruction manual - English - EN
13MNVCHPVB_2024_EN
7 Accessories
For further details on conguration and
use, refer to the relative manual.
7.1 Heater
7.1.1 Heater installation
Open the housing as described in the relative chapter
(6.1 Housing opening, page9).
Fix the heater kit to the prearranged points on the
body of the housing.
The pre-wired heating element (01) should be
positioned between the 2 dissipators (02) before
attachment to ensure contact and hence guarantee
correct heat transmission.
02
01
02
Fig. 9
Pass the heating wiring into the provided seatings.
Fig. 10
Reposition the internal slide and tighten the screws
that had been loosened previously.
7.2 Camera power supply
7.2.1 Camera power supply installation
Pay attention to the voltage used to power
the circuit. Depending on requirements use
the correct power supply kit.
Usable power supplies:
IN from 100Vac up to 240Vac, 50/60Hz - OUT
12Vdc, 1.25A
IN 230Vac, 50Hz - OUT 24Vac, 50Hz, 400mA
Fig. 11 Camera power supply.
Open the housing as described in the relative chapter
(6.1 Housing opening, page9).
Position the camera power supply in the provided
seating, parallel to the support ribs. Fix the power
supply to the body of the housing using the corner
bracket and screws supplied in the camera power
supply kit.
Fig. 12
EN - English - Instruction manual
14 MNVCHPVB_2024_EN
At the end of istallation, connect the wiring to
the terminal (power supply connector, 6.3 Board
description, page10).
Fig. 13
7.3 Blower
7.3.1 Blower installation
Not usable in versions with double lter for
air renewal.
Pay attention to the voltage used to power
the circuit. Depending on requirements use
the correct power supply kit.
The blower kit should be assembled
according to the instructions to ensure a
correct air circulation inside the housing.
Open the housing as described in the relative chapter
(6.1 Housing opening, page9).
Fix the blower using the corner bracket and screws.
The VERSO housing is provided with a single
installation location for the blower (01). In VERSO
COMPACT housing you can choose between two
dierent installation locations (02).
01
02
Fig. 14
8 Cleaning
8.1 Cleaning the window and
plastic parts
Avoid ethyl alcohol, solvents, hydrogenated
hydrocarbide, strong acid and alkali. Such
products may irreparably damage the
surface.
We recommend using a soft cloth with neutral soap
diluted with water or specic products to clean the
glasses lenses.
9 Information on disposal
and recycling
The European Directive 2012/19/EU on Waste
Electrical and Electronic Equipment (WEEE) mandates
that these devices should not be disposed of in the
normal ow of municipal solid waste, but they should
be collected separately in order to optimize the
recovery stream and recycling of the materials that
they contain and to reduce the impact on human
health and the environment due to the presence of
potentially hazardous substances.
The symbol of the crossed out bin is marked
on all products to remember this.
The waste may be delivered to appropriate collection
centers, or may be delivered free of charge to the
distributor where you purchased the equipment at
the time of purchase of a new equivalent or without
obligation to a new purchase for equipment with size
smaller than 25cm (9.8in).
For more information on proper disposal of these
devices, you can contact the responsible public
service.
Instruction manual - English - EN
15MNVCHPVB_2024_EN
10 Technical data
10.1 VERSO
10.1.1 General
Made of strong technopolymer (polycarbonate)
Sunshield in ABS
RAL9002 Colour
Stainless steel external screws
10.1.2 Mechanical
Internal usable area (WxH): 70x70mm (2.7x2.7in)
Internal usable length (with or without accessories):
270mm (10.6in)
Cable glands: 3xM16
Polycarbonate window (WxH): 105x64mm (4.1x2.5in)
Unit weight: 1.5kg (3.3lb)
10.1.3 Electrical
Supply voltage/Current consumption (empty
version):
• From 12Vdc up to 24Vdc, 1A max
• From 12Vac up to 24Vac, 1A max, 50/60Hz
• From 120Vac up to 230Vac, 400mA max, 50/60Hz
Supply voltage/Current consumption (version with
heater, Ton 15°C±3°C (59°F ±5°F), To 22°C±3°C
(72°F±5°F)):
• From 12Vdc up to 24Vdc, 5A max
• From 12Vac up to 24Vac, 5A max, 50/60Hz
• From 120Vac up to 230Vac, 700mA max, 50/60Hz
Supply voltage/Current consumption (version with
heater fan assistant, continuous duty):
• 12Vdc, 400mA max
• 24Vac, 200mA max, 50/60Hz
• From 100Vac up to 240Vac, 40mA max,
50/60Hz (with wide-range power supply)
Supply voltage/Current consumption (version with
blower and thermostat for models with double
lter for air renewal, Ton 35°C±3°C (95°F±5°F), To
20°C±3°C (71°F±5°F)):
• 12Vdc, 400mA max
• 24Vac, 200mA max, 50/60Hz
Camera power supply:
• IN from 100Vac up to 240Vac, 50/60Hz - OUT
12Vdc, 1.25A
• IN 230Vac, 50Hz - OUT 24Vac, 50Hz, 400mA
10.1.4 Environment
For indoors and outdoors installation
Operating temperature (with heater): From -20°C
(-4°F) up to +60°C (140°F)
Chemical agents resistance
• High resistance: basics, alcohols, gas, hydrocarbon
• Good resistance: Organic acids, inorganic acids,
oils
• Low resistance: Solvents
10.1.5 Certications
Electrical safety (CE): EN60950-1, IEC60950-1
Electromagnetic compatibility (CE): EN50130-4,
EN61000-6-3, EN55032 Class B, FCC Part. 15 Class B,
ICES-003 Class B
Outdoor installation (CE): EN60950-22, IEC 60950-22
IP protection degree (EN60529):
• IP66/IP67 (with cable glands)
• IP66/IP67 (with bracket with internal cable
channel, with sealing rings)
• IP55 (with bracket with internal cable channel)
• IP44 (for models with a double lter for air
renewal)
IK protection degree (EN62262): IK10
UL certication:
• cULus Listed, TYPE 4X (except for versions with
double lter for the air exchange)
• UL94, V1 (re-self extinguish)
EAC certication
EN - English - Instruction manual
16 MNVCHPVB_2024_EN
10.2 VERSO COMPACT
10.2.1 General
Made of strong technopolymer (polycarbonate)
Sunshield in ABS
RAL9002 Colour
Stainless steel external screws
10.2.2 Mechanical
Internal usable area (WxH): 63x63mm (2.5x2.5in)
Internal usable length (with or without accessories):
210mm (8.3in)
Cable glands: 2xM16
Polycarbonate window (WxH): 98x55mm (3.9x2.2in)
Unit weight: 1.1kg (2.2lb)
10.2.3 Electrical
Supply voltage/Current consumption (empty
version):
• From 12Vdc up to 24Vdc, 1A max
• From 12Vac up to 24Vac, 1A max, 50/60Hz
• From 120Vac up to 230Vac, 400mA max, 50/60Hz
Supply voltage/Current consumption (version with
heater, Ton 15°C±3°C (59°F ±5°F), To 22°C±3°C
(72°F±5°F)):
• From 12Vdc up to 24Vdc, 5A max
• From 12Vac up to 24Vac, 5A max, 50/60Hz
• From 120Vac up to 230Vac, 700mA max, 50/60Hz
Supply voltage/Current consumption (version with
heater fan assistant, continuous duty):
• 12Vdc, 400mA max
• 24Vac, 200mA max, 50/60Hz
• From 100Vac up to 240Vac, 40mA max,
50/60Hz (with wide-range power supply)
Camera power supply:
• IN from 100Vac up to 240Vac, 50/60Hz - OUT
12Vdc, 1.25A
• IN 230Vac, 50Hz - OUT 24Vac, 50Hz, 400mA
10.2.4 Environment
For indoors and outdoors installation
Operating temperature (with heater): from -20°C
(-4°F) up to +60°C (140°F)
Chemical agents resistance
• High resistance: basics, alcohols, gas, hydrocarbon
• Good resistance: Organic acids, inorganic acids,
oils
• Low resistance: Solvents
10.2.5 Certications
Electrical safety (CE): EN60950-1, IEC60950-1
Electromagnetic compatibility (CE): EN50130-4,
EN61000-6-3, EN55032 Class B, FCC Part. 15 Class B,
ICES-003 Class B
Outdoor installation (CE): EN60950-22, IEC 60950-22
IP protection degree (EN60529):
• IP66 (with cable glands)
• IP66 (with bracket with internal cable channel,
with sealing rings)
IK protection degree: EN62262, IK10
UL certication:
• cULus Listed, TYPE 4X
• UL94, V1 (re-self extinguish)
EAC certication
Instruction manual - English - EN
17MNVCHPVB_2024_EN
10.3 VERSO POLAR
10.3.1 General
Made of strong technopolymer (polycarbonate)
Sunshield in ABS
RAL9002 Colour
Stainless steel external screws
10.3.2 Mechanical
Internal usable area (WxH): 70x70mm (2.7x2.7in)
Internal usable length (with or without accessories):
270mm (10.6in)
Cable glands: 3xM16 (nickel-plated brass for external
connections)
Polycarbonate window (WxH): 105x64mm (4.1x2.5in)
Unit weight: 1.5kg (3.3lb)
10.3.3 Electrical
Supply voltage/Current consumption (version with
heater, Ton 15°C±3°C (59°F ±5°F), To 22°C±3°C
(72°F±5°F)):
• From 12Vdc up to 24Vdc, 5A max
• From 12Vac up to 24Vac, 5A max, 50/60Hz
• From 120Vac up to 230Vac, 700mA max, 50/60Hz
Camera power supply:
• IN from 100Vac up to 240Vac, 50/60Hz - OUT
12Vdc, 1.25A
• IN 230Vac, 50Hz - OUT 24Vac, 50Hz, 400mA
10.3.4 Environment
For indoors and outdoors installation
Operating temperature (with heater): From -55°C
(-67°F) up to +60°C (140°F)
Chemical agents resistance
• High resistance: basics, alcohols, gas, hydrocarbon
• Good resistance: Organic acids, inorganic acids,
oils
• Low resistance: Solvents
10.3.5 Certications
Electrical safety (CE): EN60950-1, IEC60950-1
Electromagnetic compatibility (CE): EN50130-4,
EN61000-6-3, EN55032 Class B, FCC Part. 15 Class B,
ICES-003 Class B
Outdoor installation (CE): EN60950-22, IEC 60950-22
IP protection degree (EN60529):
• IP66 (with cable glands)
• IP66 (with bracket with internal cable channel,
with sealing rings)
• IP55 (with bracket with internal cable channel)
IK protection degree: EN62262, IK10
UL certication:
• cULus Listed, TYPE 4X
• UL94, V1 (re-self extinguish)
EAC certication
EN - English - Instruction manual
18 MNVCHPVB_2024_EN
11 Technical drawings
The indicated measurements are expressed in millimetres.
77
100
26
156
270 70
70
70 171
40 73
70
62
15
101
113
466
B
B
A
A
A - A B - B
70
USABLE
AREA
USABLE AREA
Fig. 15 VERSO.
210
400
94 15
135
18
94
106
63
63
B
B
A
A
A - A B - B
USABLE
AREA
USABLE AREA
Fig. 16 VERSO COMPACT.
Instruction manual - English - EN
19MNVCHPVB_2024_EN
156
270 70
70
70 171
40 73
70
62
15
101
113
466
B
B
A
A
A - A B - B
70
USABLE
AREA
USABLE AREA
Fig. 17 VERSO POLAR.
MNVCHPVB_2024_EN
Headquarters Italy Videotec S.p.A.
Via Friuli, 6 - I-36015 Schio (VI) - Italy
Tel. +39 0445 697411 - Fax +39 0445 697414
France Videotec France SARL
Immeuble Le Montreal, 19bis Avenue du Québec, ZA de Courtaboeuf
91140 Villebon sur Yvette - France
Tel. +33 1 60491816 - Fax +33 1 69284736
Email: info.fr@videotec.com
Asia Pacic Videotec (HK) Ltd
Flat 8, 19/F. On Dak Industrial Building, No. 2-6 Wah Sing Street
Kwai Chung, New Territories - Hong Kong
Tel. +852 2333 0601 - Fax +852 2311 0026
Email: info.hk@videotec.com
Americas Videotec Security, Inc.
Gateway Industrial Park, 35 Gateway Drive, Suite 100
Plattsburgh, NY 12901 - U.S.A.
Tel. +1 518 825 0020 - Fax +1 518 825 0022
Email: info.usa@videotec.com
www.videotec.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104

Videotec VERSO POLAR User manual

Category
Security camera accessories
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI