*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
ceiling
Screw/Anchor
Cable Coupler Installation
Screw
Cable Coupler Installation
1.2 If using the supplied toggle anchor, drill a 3/8” hole at all marked locations.
1.3 Feed the screw through the cap, washer, and toggle anchor and properly secure into
place. Repeat for all remaining mounting points.
1.4 If securing to a solid surface or into framing, feed the screw
(not provided) through the cap and washer, and secure directly
into the surface. Repeat for all remaining mounting points.
1.4
Mounting Preparations
Note: Prior to installation all 24VDC wires must be present in junction box. Refer to
the power supply installation instruction for additional information.
Note: More than one person is recommended for this installation.
1.1 Refer to approved Custom Layout Drawing by Luminii for A/C cable
mountingpoints. Mark these mounting points on the ceiling in preparation
for cable coupler and canopy installation.
A/C cable
Cap cover
drill
bit
drill
anchor
cap
screw
washer
screw
cap
washer
anchor
1
1.2
Power feed location
On continuous runs cable grippers
are attached to mechanical joiners
Max 72”
for track sections greater than 72” an additional
cable gripper is required in middle of track
Max 72”
for track sections greater than 72” an additional
cable gripper is required in middle of track
4”
or less
Note: If not using the supplied toggle anchor, and installing to a hollow ceiling or concrete, must use a #6 screw size anchor, that must be rated for a minimum of 30lbs.
Route A/C cable through cap cover and thread cap cover into cap.
1
Stenos Installation Instructions
Suspended Track
Please read all instructions prior to installation and keep for future reference!
1. Product to be installed by a qualified electrician
2. Use only with class 2 power unit
3. 24 Volts DC
4. Suitable for dry locations only
5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are
used to continue power down the track.
7. System shapes and power feed locations shown are for reference only. Refer
to custom drawing package for the particulars of a specific custom system.