  • Hello! I am an AI chatbot trained to assist you with the Maxcess SE-37 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Fife Corporation
P.O. Box 26508, Oklahoma City, OK 73126, U.S.A.
Phone: 405.755.1600 / Fax: 405.755.8425
www.fife.com / E-mail: fife@fife.com
Copyright© 2004 Fife Corporation. All rights reserved. Revised 10-22-2004
1 of 4 Figure Sheet 1-820-B
INSTALLATION
INSTRUCTIONS FOR SE-37 ULTRASONIC SENSOR
SE-37 SENSOR ASSEMBLY
0.75 [19.1]
2.16 [54.8]
2.66 [67.5]
7/16-20 UNF THD THRU
(1) HOLE
M8 THREAD THRU
(1) HOLE
0.66 [16.7]
M5 THD
(2) PLACES 0.63 [15.9]
6.00 [152.4]
1.00 [25.4]
PROPORTIONAL
BAND
1.16 [29.4]
REF
3.00 [76.2]
1.16 [29.4]
5.31 [134.9]
5.50 [139.7]
3.38 [85.7] 1.00 [25.4]
1.75
[44.5]
1.50
[38.1]
1.25 [31.8]
Figure 1.
Product Specifications:
Weights:
SE-37 Sensor:
20 oz (566 g)
With M-17 Mounting Assembly:
23 oz (652 g)
With M-18 Mounting Assembly:
24 oz (680 g)
Operating Temperature:
32° to 140° F (0° to 60° C)
Voltage Required for Operation:
10-15 VDC
Max Supply Current:
27 mA
Output Signal:
0 to 10 mA
Proportional Band:
1.00 inch (25.4 mm)
ESD Protected:
Designed to IEC 801-2
SE-37 ULTRASONIC SENSOR
Revised 10-22-2004
Figure Sheet 1-820-B 2 of 4
INSTALLATION - Continued
INSTRUCTIONS FOR SE-37 ULTRASONIC SENSOR
B
OPTIONAL M17 OR M18
SENSOR MOUNTING
(SEE TABLE)
CD
1.88
[47.6]
A
SQUARE
BAR SIZE 1.50
[38.1]
2.50
[63.5] 2.00
[50.8]
Figure 2.
SE-37 SENSOR ASSEMBLY
WITH OPTIONAL M-18
MOUNTING BRACKET
SENSOR
MOUNTING
SQUARE BAR
BC
D
SE-37
3” GAP
A
SIZE
MAXIMUM
LENGTH
M-17 0.75
(19)
60.00
(1524)
0.63
(16)
1.53
(39)
0.63
(16)
M-18 1.00
(25)
86.00
(2184)
0.75
(19)
1.53
(39)
0.75
(19)
(All dimensions in parantheses are millimeters)
SE-37 ULTRASONIC SENSOR MOUNTING
INSTALLATION - Continued
INSTRUCTIONS FOR SE-37 ULTRASONIC SENSOR
Revised 10-22-2004
3 of 4 Figure Sheet 1-820-B
The SE-37 Sensor will provide satisfactory web guidng in a
position perpendicular to the WEB PASS LINE. However, if the
application warrants more accuracy, the SE-37 Sensor will
provide the optimum performance when installed at a 45°
angle to the WEB PASS LINE. When the SE-37 Sensor (P/N
67386-001) with a gap of 3.00 inches (76 mm) is installed at
a 45° angle to the WEB PASS LINE the EFFECTIVE GAP (E) is
1.24 inches (32 mm).
3.00 [76.2]
E
SENSOR AXIS
WEB PASS LINE
ϕ
Figure 3.
SE-37 ULTRASONIC SENSOR MOUNTING
E = [sin(
ϕ
-22.62)]3.25
Recommended angle of installation is 45°.
45° to 90°angle is acceptable BUT will
reduce sensor preformance.
Revised 10-22-2004
Figure Sheet 1-820-B 4 of 4
INSTALLATION - Continued
INSTRUCTIONS FOR SE-37 ULTRASONIC SENSOR
0.50 [13]
B
D
A
C
E
G
F
SQUARE
BAR
SE-37
M-1935 MOUNTING
0.50 [13]
B
D
A
C
E
G
F
SQUARE
BAR
SE-37
M-1935 MOUNTING
Figure 4.
SENSOR
MOUNTING
SQUARE BAR AB
ADJUSTABLE
CD
ADJUSTABLE
EF
ADJUSTABLE
G
ADJUSTABLE
SIZE MAXIMUM
LENGTH
M-1935
1.00
(25)
86.00
(2184)
2.00
(51) 8.88-10.01
(226-254)
2.00
(50.8)
10.00-11.13
(254-283)
2.94
(75) 1.80-3.30
(46-84)
1.00-5.50
(25-140)
1.25
(32)
96.00
(2438)
2.50
(64)
4.50
(114)
1.00-7.00
(25-178)
M-7925
1.00
(25)
86.00
(2184)
2.0
(51) 8.00-9.13
(203-232)
1.12
(28)
9.12-10.25
(232-260)
2.94
(75) 1.80-3.30
(46-84)
1.00-5.50
(25-140)
1.25
(32)
96.00
(2438)
2.50
(64)
4.50
(114)
1.00-7.00
(25-178)
(All dimensions in parantheses are millimeters)
SE-37 SENSOR ASSEMBLY
WITH OPTIONAL M-1935
MOUNTING BRACKET
SE-37 SENSOR ASSEMBLY
WITH OPTIONAL M-7925
MOUNTING BRACKET
/