Awarepoint S2 User manual

Type
User manual

This manual is also suitable for

The Awarepoint S2 is a wireless sensor designed for use in real-time locating systems. It can be plugged into a standard electrical outlet and communicates with other S2 sensors and a central bridge to create a mesh network that tracks the location of tagged assets and people. The S2 provides accurate positioning data and can be used for applications such as inventory tracking, asset management, and personnel safety monitoring. Its compact size and easy installation make it suitable for a variety of indoor environments, including hospitals, warehouses, and manufacturing facilities.

The Awarepoint S2 is a wireless sensor designed for use in real-time locating systems. It can be plugged into a standard electrical outlet and communicates with other S2 sensors and a central bridge to create a mesh network that tracks the location of tagged assets and people. The S2 provides accurate positioning data and can be used for applications such as inventory tracking, asset management, and personnel safety monitoring. Its compact size and easy installation make it suitable for a variety of indoor environments, including hospitals, warehouses, and manufacturing facilities.

Awarepoint Sensor S2
Installation Manual
Date: 02/14/2008
AwarepointCorporation
225Broadway,Suite1670
SanDiego,CA92101
www.awarepoint.com
Document History
Date Author Changes
02/14/2008 Derek Smith Initial Draft
1
Awarepoint Sensor S2 © 2008 Awarepoint Corporation
Installation Manual
Copyright
Copyright2008AwarepointCorporation
Allrightsreserved.Thisproductordocumentisprotectedbycopyrightanddistributedunder
licensesrestrictingitsuse,copying,distribution,anddecompilation.Nopartofthisproductor
documentmaybereproducedinanyformbyanymeanswithoutpriorwrittenauthorizationof
Awarepointandits
licensors,ifany.
Awarepoint,theAwarepointlogo,andRealtimeAwarenessSolution,aretrademarksor
registeredtrademarksofAwarepointCorporationintheUnitedStatesandinothercountries.
FCCCompliance
AwarepointSensormodelS2FCCID:UAGS2
ThisdevicecomplieswithPart15oftheFCCRules.Operationis
subjecttothefollowingtwo
conditions:(1)thisDevicemaynotcauseharmfulinterferenceand(2)thisDevicemustaccept
anyinterferencereceived,includingInterferencethatmaycauseundesiredoperation.
CAUTION:Changesormodificationsnotexpresslyapprovedbythepartyresponsiblefor
compliancecouldvoidtheuser'sauthoritytooperate
theequipment.
CAUTION:Thismanualdescribesinstallationproceduresforelectricalequipment.Proper
precautionsarerequired.Particularattentionshouldbegiventotexthighlightedwiththe
followingsymbol:
2
Awarepoint Sensor S2 © 2008 Awarepoint Corporation
Installation Manual
TableofContents
Section Page
1
Introduction ............................................................................................... 3
1.1 Overview .............................................................................................. 3
1.2 Preparing for Installation – Read this First! .......................................... 3
1.2.1 Tools and Supplies .................................................................................................. 3
1.2.2 Information ............................................................................................................... 3
1.3 System Components ............................................................................ 4
1.3.1 Sensor ..................................................................................................................... 4
2 Awarepoint Sensor Installation ................................................................ 5
2.1 Physical Installation ............................................................................. 5
2.2 Secure Awarepoint Sensors ................................................................. 6
2.3 Verify the Sensor Connects to the Network ......................................... 6
2.4 Place Awarepoint Sensor on Map ........................................................ 6
3 Troubleshooting ...................................................................................... 30
3.1 Awarepoint Sensor ............................................................................. 30
3
Awarepoint Sensor S2 © 2008 Awarepoint Corporation
Installation Manual
1 Introduction
Customersupport:1888TAGITNOW
1.1 Overview
ThissysteminstallationmanualisforanAwarepointemployeeorAwarepointtrained
serviceproviderwhointendstoinstalltheAwarepointSensor.
1.2 Preparing for Installation – Read this First!
1.2.1 Tools and Supplies
Priortoinstallation,youwillneedthefollowingtoolsandsupplies:
1. SmallEthernetswitches(ifnecessarytopluginyourlaptop)
2. HospitalGradePowerStrips(ifnecessarytoputanAwarepointSensorinanoutlet
thatisfull)
3. InstallationKit,consistingofthefollowing:
SerialCablewith
NullModemAdapterandFFGenderChanger
EthernetCable
ZipTies
DoubleSidedTapeMountingStrips
4. InstallationTools,consistingofthefollowing:
Laptop
Terminalemulatorsoftware(werecommendTeraTerm,availablefrom
http://www.tucows.com/preview/195282
)
USBtoSerialadapter(iflaptopdoesnothaveaserialport)
WirecuttersfortrimmingZipties
Insulatedbladescrewdriverforelectricalfaceplates,ifyoumakeanerror
whentapingtheAwarepointSensorsdown
PhillipsscrewdriverforinstallingtheAwarepointAppliance
1.2.2 Information
Priortoinstallation,youwillneedthefollowinginformation:
1. Mapsforallfloors,inpaperandelectronicformatwithcoverageareaoutlined
2. AwarepointBridge
IPAddressing:DHCPorStatic.IfusingStaticaddressingthen: IPAddress,Default
Gateway,andSubnetMask.
IPAddressofAwarepointAppliance
4
Awarepoint Sensor S2 © 2008 Awarepoint Corporation
Installation Manual
Location,withanEthernetportthathasbeentestedandconfiguredtowork
with10BaseT,fullduplexEthern et.(A10/100autosensesettingshouldbe
adequate)
1.3 System Components
TheAwarepointRealtimeAwarenessSolutionconsistsofseveralcomponentsasshown
inthediagrambelow.Thepartsofthesystemthatrequireinstallationinclude
AwarepointTags,AwarepointSensors,AwarepointBri dges,and theAwarepoint
Appliance.TheAwarepointAppliancecontainsallsoftwarenecessaryforsystem
operation.
Figure 1-1.1: System Diagram
1.3.1 Sensor
ThereareseveralmodelsofSensors.
5
Awarepoint Sensor S2 © 2008 Awarepoint Corporation
Installation Manual
Figure 1.1-2: Awarepoint Sensor model R1 Figure 1.1-3: Awarepoint Sensor model S2
TheSensormodelR1displaysitsstatusthreevisualindicatorsintheformofLight
EmittingDiodes(LEDs).ThetopmostLEDindicatesnetworkstatus.Redindicatesthat
theSensorcannotcommunicatewithanyotherdevices.Yellowindicatesthatitcan
communicatewiththeBridgebutnottheAppliance.Greenmeansthat
itcan
communicatewiththeBridgeandAppliance.ThemiddleLEDindicatesnetworkactivity.
Innormaloperation,itwilloccasionallyblink.Thebottom LED(blue)indicatespower.If
thedeviceispluggedintoanoutletthathaspowerthenitisilluminated.
TheSensormodelS2displaysitsstatuswith
oneLEDvisualindicator.Ifitisoffthenthe
deviceisdefectiveornotpowered.RedindicatesthattheSe nsorcannotcommunicate
withanyotherdevices.YellowindicatesthatitcancommunicatewiththeBridgebut
nottheAppliance.Greenmeans thatitcancommunicatewiththeBridgeandAppliance.
2 Awarepoint Sensor Installation
Sensorsneedtobelocatedthroughoutthecoveragearea,includingalongthe
perimeter.WheninstallingSensors,beginbyinstallingSensorsneartheBridge andwork
progressivelyoutwardinconcentriccircles.Inthismanner,youwillminimizethe
numberofSensorsthatmustbemoved.
PriortoinstallingtheSensors,theAppliance
andBridgemustbeinstalledcorrectly.
2.1 Physical Installation
TheSensorsareinstalledinstandardelectricalpowerreceptacles.Priortoinstallingthe
Sensoryoumustlocateapoweredoutlet.Verifythatthereceptaclehaspowerbyusing
anelectricaltester.
6
Awarepoint Sensor S2 © 2008 Awarepoint Corporation
Installation Manual
2.2 Secure Awarepoint Sensors
Onceyouhaveoptimizedthemeshnetwork,removetheSensor;applydoublesided
tapestriptothetopoftheoutputfaceplateandreinstalltheSensor,pressingfirmlyto
adhere.

CAUTION:Toremoveasensorthathasbeensecuredinplace,usetheinsulated
bladescrewdrivertofirstremovetheelectricalfaceplateandsensorfromthewall,
thenseparatethesensorfromthefaceplate.NEVERreachbehindthesensorinan
efforttoinsertorremoveitfromtheoutletaselectricalshockmayoccurifyou
contacttheelectricalprongswhiletheyarestillinsertedintheoutlet.Forinsertionor
removal,graspthesensorbythesidesonly.
2.3 Verify the Sensor Connects to the Network
OnceyouplugtheSensorintoanoutlet,itwillattempttoconnecttotheAwarepoint
network.Thisprocesswilltakeapproximately one minute.WhentheSensorhas
completedthisprocess,theNetworkLEDwillbeilluminatedGreen.IftheSensoris
unabletoconnecttothenetwork(outofrange
ofanetworkornetworknotproperly
configured),theSensorwillcontinuetoattempttoconnecttothenetworkandthe
NetworkLEDwillbeRed.
OncetheSensorhassuccessfullyconnectedtothenetwork,marktheSensorlocation
anditsMACaddressonapapercopyofthemap.
2.4 Place Awarepoint Sensor on Map
OpentheSystemManagerandclickonthePositioning:Configurationtab.TheSensor
youjustinstalledshouldshowupintheUnassignedsectionofthedevicetree.Ifitis
functioningcorrectly,theiconfortheSensorshouldbegre en.
Inthedevicetree,expandtheCampusandBuildingsothat
youcanseethefloor.Click
onthefloortodisplaythemapforthefloor.DragtheSensoriconontothemapand
placeitwhereitislocated.
Figure21:Positioning:ConfigurationTab‐PlacingAwarepointSensor
30
Awarepoint Sensor S2 © 2008 Awarepoint Corporation
Installation Manual
Finally, click the Apply button.
ContinuetoplaceallSensors.Astheyareplaced,theywilljointhenetwork.Some
routinglineswillbedisplayedasshownbelow.
Figure22:Positioning:ConfigurationTab‐PlacingallAwarepointSensors
3 Troubleshooting
CustomerSupport:1888TAGITNOW
3.1 Awarepoint Sensor
IftheSensorappearsRedinthePositioning:ConfigurationtaborontheAwarepoint
NetworkOperationsCenter,theSensorhasaproblem.Try thefollowingsteps:
1. VerifytheBridgenearesttheSensorisfunctioningcorrectly.VerifytheApplianceis
functioningcorrectly.
2. IfmultipleSensorsweredownandtheyare
allgroupedtogether,likelythesewere
allroutingthroughoneSensorandthatSensorlostconnectivity.Wait
approximatelyonehourandcheckthestatusagain. IftheSensorsarestilldown,
proceedtostep3.
3. VerifythattheSensorisphysicallypresent.Ifso,thenproceed.
4. Unplugand
replugtheSensor.Ifitisstillred,replacetheSensor.If anotherSensoris
redinthesamelocation,likelytheSensorisoutofrangeofthenextnearestSensor.
MovetheSensorclosertotheSensorsthatareworking.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Awarepoint S2 User manual

Type
User manual
This manual is also suitable for

The Awarepoint S2 is a wireless sensor designed for use in real-time locating systems. It can be plugged into a standard electrical outlet and communicates with other S2 sensors and a central bridge to create a mesh network that tracks the location of tagged assets and people. The S2 provides accurate positioning data and can be used for applications such as inventory tracking, asset management, and personnel safety monitoring. Its compact size and easy installation make it suitable for a variety of indoor environments, including hospitals, warehouses, and manufacturing facilities.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI