alpro EB1001 Operating instructions

Type
Operating instructions
Electric Bolt
E
B1001 - Instructions
15
126.5
203
57.5
9.5
40
1
4
172
3
AUTOLOCK TIME DELAY SETTING
0 SEC
3 SEC
6 SEC
9 SEC
1 2
ON
OFF
1 2
ON
OFF
1 2
ON
OFF
1 2
ON
OFF
17
9.5
TECHNICAL INFORMATION
Power to Lock/Fail open.
Stainless steel bolt - diameter 15mm
- throw 15mm
Voltage required 12vDC
Activating current 1.0A
Holding current 250 mA
Fully protected against transients and
reverse polarity
The Autolock Time Delay can be set for
0, 3, 6 or 9 seconds.
Monitoring - Door position switch (DSS)
- Bolt position indicator
GENERAL INSTALLATION
INSTRUCTIONS
Ensure you have the following:-
- Strike plate
- Electric bolt
All rebate strips and/or frame stops
should be fitted before starting.
A 2 amp Power Supply should be
provided to ensure there is a Full 1
amp for the bolt. This should allow for
a basic Access System and a back up
battery to be connected to the same
source.
WARNING - THE CONNECTION
OF AN INCORRECT VOLTAGE
MAY RESULT IN DAMAGE NOT
COVERED BY THE PRODUCT
WARRANTY.
The selection of appropriate power
supply cable is very important to
ensure lock receives sufficient power
to operate.
First Choice for Locking Solutions
012 0 2 676262 01202 680101 alpro@iecltd.co.uk www.alpro.co.uk
T F E W
1
2
4
3
alpro
®
Bolt Face Plate 203 x 34 x 3mm
Strike Plate 98 x 34 x 3mm
EB1001 Instructions_A5:EB501-22 Instructions 1/8/07 17:53 Page 1
Electric Bolt
E
B1001 - Instructions
Connect flying leads (+) Red (-)
Black. Note - other leads for
connection of LED via plug in lead
*NOT FOR POWER INPUT*.
This product has been designed for
use in weather protected areas and
under normal circumstances does not
require any maintenance. DO NOT
OIL OR LUBRICATE.
This product must be used in
conjuction with a quality floor spring
or door closer to ensure positive
realignment on closing.
6
7
5
0120 2 676 2 6 2
0 1 2 0 2 6 8 0 1 0 1
alpro@iecltd.co.uk
w w w. a l p r o . c o . u k
T
F
E
W
I
I
E
E
C
C
L
L
i
i
m
m
i
i
t
t
e
e
d
d
Harwell Road Nuffield Estate Poole Dorset BH17 0BD Great Britain
Registered in England 1925537
© July 2007 IEC. All rights reserved.
All dimensions are nominal and subject to tolerances
79
15.5
98.4
15.5
30.4
15.2
M5 x 0.8 x 2
ø5.1 x 2
C Of Door
17.2
34.4
184
203.4
15.5
10
10
15.5
50 REF
M5 x 0.8 x 2
ø8 LED
C Of Door
ø5.1 x 2
Door Status Sensor
W
hite Normally Open
White Common
Rated 0.5A
12vDC
LED
BLACK (-) Negative
R
ED (+) Positive