606981 EN Appendix to the User’s Manual
02.03.12 DOL 95 Broiler, Restriktive Chain Feeding
A feeding period starts with a feeding. The chain runs a whole round. The feeding stops when the
cross auger has not been activated for a given period (Stop of feeding - cross auger). At the end of
a feeding it is checked whether the supplied feed is more or less than the required feed quantity
for the whole feeding period. If it is above, the feeding is finished. If it is below, the feeding
continues during the feeding period*. "Start of next feeding" is decided by the amount of feed
missing plus the estimated eating speed.
*If the remaining amount is smaller than "Min. correction", the feeding stops.
Example:
If "Min. correction" is 50 kg, the feeding will stop when the remaining amount is less than 50 kg
compared to the required amount.
"Max. correction +/- " states the allowed correction compared to the feed reference.
Example:
"Max. correction +/-" is 30/10 %. This means that the required amount during a feeding period can
maximum become 30 % larger or 10 % smaller than the feed reference.
If the feed reference is 500 kg in a feeding period, the current required amount could be between
450 and 650 kg due to too much or too little feed in the previous period.
Normally the feeding chain runs a whole round. However, it is possible to adjust the DOL 95 so
that it stops the chain just at the moment when the required amount is reached.
3) Feed program restrictive with correction (continued)
In restrictive feeding it is possible to "transfer" feed from one feeding period to another. One feeding
period consist of one or more feedings. The start of a feeding period is determined by either the
feed program or the light program.
There are two possibilities:
1) "Stop chain at period total". Stops the chain when the required amount in the period has been
reached.
2) "Stop chain at day total". Stops the chain when the required amount for the day as been
reached.
In a normal broiler production it is not desirable to stop the chain before it has run a whole round.
Therefore both parameters should be set to "No".
House 1 Feed program restrictive
Time for a chain round 30:00 m:s
Stop chain at day total No
Stop chain at period total No
Back
Feed/program/chain/setup
House 1 Feed program restrictive
Stop of feeding - cross auger 15 min.
Min. correction 50 kg
Max. correction +/- 30 10 %
Back
Feed/program/restrictive/correction