FOR ELECTRICIAN
Non Heated Leads /Supply Leads Yellow / Red from rolls Black from rolls
Box Dimensions: 8 1/2" x 8 1/2" x 4 1/4"
Red Load
From Thermostat Control
Optional Thermostat
Power Source 240V Black (Hot) from
240V Power Source
Red (Hot 240V, Neutral 120V)
Power Source
L2 L1 L2 L1 L2 L1
Front
12
Location of ground
wires from rolls
No Polarity needs
to be respected
Black Load
FLOOR SENSOR
WIRING DIAGRAM
FOR 120V & 240V TEMPZONE TWIN WITH
SOLID STATE RELAY CONTACTOR
ITEM#: RC-40Amp
10113 -A 1/13
BRAIDED GROUND SHEATH
COLD LEAD
BLACK WIRE
RED 240V
or
YELLOW 120V
HOT
FROM POWER SOURCE 120V & 240V
HOT (240V) or
NEUTRAL (120V)
Red
Black
THERMOSTAT
Load
S
L2 (N)
L1 (L)
Free Design Service • 24/7 Installation Support • No Nonsense™ Warranty •(800) 875-5285 • www.WarmlyYours.com