5
19
ZC.l.i.1 ZC.l.i.3ZC.l.i.2
0
1
2
3
4
5
6
7
8
9
10
11
M
0
1
2
3
4
L
0
1
2
3
4
5
6
7
K-I
J
ZC. y2 ZC. y3
ZC. y1
ZC. Io.
ZC. h.i.
ZC.u.y.1
ZC.1n.r.
ZC. y6
ZC.u.y6
R
0
1
2
3
4
0
1
2
3
4
Q
0
1
2
3
4
5
6
7
8
O
P
CONFIGURATION
-999…9999
Beginning value for
linear scales G
M
Full value for
linear scales H
N
=999…C.1o. -100 or
C.1o+100…9999
minimum span 100 counts
None
Manual control
1st memorized Set point
2nd memorized Set point
3rd memorized Set point
Remote Set point
Local Set point
Locked keyboard
(see note on the left)
Functions
of the 3 logic inputs
Relay
Logic
Continuous
Relay
Continuous
Relay
Logic
Continuous
Control output type
Y1(▲) Y1(▼)
Relay
Logic
Continuous
Servomotors
Relay
Relay
Relay
Logic
Logic
Continuous
Continuous
Continuous
SingleDouble
Codes 8,10 and 11, can be selected
if the 2nd analog output option (Y6)
is fitted.
These codes depend on the B Table
(Cy1).
0…1
0…3
4…11
If control action is
(B Tab.) Select
(M Tab.)
On - Off
single P.I.D.
double P.I.D.
Y1 output range N
0
1
2
3
4
4…20 mA
0…20 mA
1…5 V
0…5 V
0…10 V
Current
Voltage
Y2-Y3
Alarm type
N.A.(close)
N.C. (open)
Active high
Active low
Active high
Active low
Active low
Active inside
Disabled
Input
interruption (*)
Independent
Deviation
Band
4…20 mA
0…20 mA
1…5 V
0…5 V
0…10 V
OPTION
Y6 2nd analog output type
Retransmiss.
Measure X1
Set point W
Output Y1
Output Y1(channel ▼)
Disabled
These codes are available only if the
2nd analog output has not been used
as second control output
(C. y6 M Tab codes 8,10,11)
Y6 output range
4…20 mA
0…20 mA
1…5 V
0…5 V
0…10 V
Current
Voltage
These codes are available only if the
2nd analog output is used as second
control output
(C. y6 Q Tab codes1,2,3,4 or
C. yI M Tab codes 8,10,11)
The code is available only if the main
output (Y1) is of the analog type
(see M Table codes 2, 6, 9,11).
Remote Set point
scale range
Current
Voltage
Logic input notes
Each one of the the three logic
inputs can be freely configured to
perform one of the functions listed
in table K-I-J.
Logic signals shall be of the
maintained type.
The function is operating when the
logic input is “ON”.
When the logic input is “OFF” the
function is idnhibited.
“ON” logic inputs have the priority
on the keyboard and Serial comm.s
controls.
1 with OFF input returns on
automatic
2,3,4 with OFF input returns on
local set point
If more than one logic input
are simultaneously ON to
request one of the three
memorized set point, the
last request memorized set
point will be operating.
5 with OFF input returns on
local set point
6 with OFF input returns on
remote set point
7 with OFF input keyboard is
unlocked
When the keyboard is
locked, the other logic
inputs and the serial
comm.s are operative.
2, 3, 4, 5, 6, codes depend
on the type of Set point
previously entered.
(Tab. C)
(*) Only for thermoelements,
4…20mA and 1…5V
Is present only if remote Set point has
been selected Tab. C - codes 2,3