Soyal ISP Tool Owner's manual

Type
Owner's manual
System Requirements
Operating System: Win7/ Win10, Windows Server 2012/2016/2018, hyper V
Processor Server: Intel® Pentium® and above
Installed Memory (RAM): min. 8GB
Hard Disk: 80GB of free space
Built-in USB transmission interface
Software Download
SOYAL Software Series
V211012
Software Manual
ISP Tool
SOYAL Website
02
02
03
01
01
05
07
08
09
Main Features
Note ID Setting
1
2
3
4
Software Window
ntroduction
Software Operation
3-1 Execute ISP Tool ................................................
3-2 Software Window Introduction ............................
3-3 Model Name Selection ........................................
4-1 Upgrade Firmware for H Series Controller...........
4-2 Reset Master code for H Series Controller...........
4-3 Read EEPROM Data of H Series Controller.........
4-4 Write EEPROM Data of H Series Controller..........
....................................................................................
....................................................................................
Contents
10
10
Reference
55-1 FAQ .....................................................................
5-2 YouTube Videos ..................................................
SOYAL Software Series
ISP Tool
SOYAL TECHNOLOGY CO., LTD
RS485
SOYAL
ISP Tool Main functions :
Be suitable for rmware upgrading of Home H Series ControllerAR-716-E18(AR-
716E)AR-716-E02(AR-721E)AR-401 and AR-403 I/O Module
(Note: SOYAL Proximity Readers only support to upgrade rmware via COM Port Communication)
Reset Master code for H Series Controller
Read EEPROM Data of H Series Controller
Write EEPROM Data of H Series Controller
Before Upgrading Firmware by ISP Tool, Node ID should be set for each device so it
can communicate with computer, and then ISP Tool will be able to send commands to
the assigned Node ID of each device.
node ID 001
AR-321-CM
AR-888-H
What to do if forget the node ID :
If the node ID is forget or not conrmed, please refer to the below method to set node ID.
(Method 1)
Use command to change Node ID (Be suitable for H series controller and master code is
necessary)
(Method 2 )
When only one controller is connected for firmware upgrade, you can enter 255 as Node ID
instead of actual Node ID.
Step1 Enter programming Mode
Input 123456 or PPPPPP
Enter the program mode
Enter the program mode
[e.g.] The Default Value= 123456, if the Master Code is already changed= 876112, input 876112 → program
Step2 Change Node ID
Input 00 NNN [Node ID: 001~254; if the access controller is connected to AR-716E, its Node ID will be 001~016.]
1.
2.
Main Features
Node ID Setting
1. Main Features / 2. Note ID Setting
SOYAL Software Series
ISP Tool
SOYAL TECHNOLOGY CO., LTD 01
1 4
5
6
7
8
9
2
3
1 4
3 6
2 5
7
8
9
Model Name Selection
Processing Status Bar
Communication
Port Selection
Node ID Number
Load Firmware File
Upgrade Firmware
Reset Master Code
Read EEPROM User
Write EEPROM User
Execute ISP Tool
Software Window Introduction
3-1
3-2
After installing SoyalToolSetup ,Run ISP Tool on your computer:
(※Note: If your computer has running 701 Server software, you need to close 701Server before
running this software to avoid communication port being occupied. Please make sure to install
USB Driver before running the software.
1
2
Shortcut “ SP Tool “ is created on Desktop and twice click to run ISP Tool
Or you can execute it on your computer > Start > Soyal Software folder >
click to run ISP Tool
3. Execute ISP Tool
3. Software Window Introduction
SOYAL Software Series
ISP Tool
SOYAL TECHNOLOGY CO., LTD
02
1
AR-101-H / AR-321-H / AR-331-H / AR-721-H / AR-725-H / AR-757-H / AR-888-H /
AR-888-W / AR-323-D / AR-401 Series / AR-403 Series / AR-716-E02
The No.1 is suitable for below devices either EM Frequency or Mifare Frequency
Applicable Model Name:
Model Name Selection :
3-3
3. Software Window Introduction
SOYAL Software Series
ISP Tool
SOYAL TECHNOLOGY CO., LTD 03
2
3
2
3
AR-716-E18
AR-101-U / AR-723-U / AR-721-K / AR-725-U / AR-725-K
Applicable Model Name:
Applicable Model Name:
The No.3 is suitable for Multi-door controller AR-716-E18
The No.2 is suitable for below Mifare Wigeand Readers
3. Software Window Introduction
SOYAL Software Series
ISP Tool
SOYAL TECHNOLOGY CO., LTD
04
1
2
3
4
5
STEP 1 : Select the COM Port of the actual connected device.
STEP 2 : Select the Model name according to the device you are using
( AR-888-H / Node ID 001 as example).
STEP 3 : Enter the Node ID of the controller.
STEP 4 : Load the correct rmware le.
STEP 5 : Click “ Upgrade Target ” button to program.
4. Software Operation
Upgrade Firmware for H Series Controller
4-1
4. Software Operation
SOYAL Software Series
ISP Tool
SOYAL TECHNOLOGY CO., LTD 05
6
7
STEP 6 : The rmware is programming ( The bar indicate the programing status).
{It is normal if some devices sound a long beep during the update process}
STEP 7 : The program is completed and click “Yes” to exit.
There is a risk in upgrading the firmware of the device. If the communication is interrupted
during the upgrade process or using incorrect the firmware file to upgrade, the CPU of
the device will be broken. Therefore, it is suggested that the distance between the device
and computer is as short as possible, and it is best to only connect one device under USB
Converter to upgrade and disconnected other devices in the same communication port.
Home H series devices do not support updating firmware via TCP/IP communication
interface.
Note:
4. Software Operation
SOYAL Software Series
ISP Tool
SOYAL TECHNOLOGY CO., LTD
06
1
2
3
4
5
STEP 1 : Select the COM Port of the actual connected device.
STEP 2 : Select the Model name according to the device you are using
( AR-888-H / Node ID 001 as example).
STEP 3 : Enter the Node ID of the controller.
( If Node ID is forgotten, please enter “255” as Node ID).
STEP 4 : Click “Reset Master Code “ option to start to reset.
STEP 5 : Till Pop-up the window as below, that indicate Master Code has been
reset to default value 123456
Reset Master code for H Series Controller
4-2
4. Software Operation
SOYAL Software Series
ISP Tool
SOYAL TECHNOLOGY CO., LTD 07
1
5
2
3
4
6
STEP 1 : Select the COM Port of the actual connected device
STEP 2 : Select the Model name according to the device you are using
( AR-888-H / Node ID 001 as example)
STEP 3 : Enter the Node ID of the controller.
STEP 4 : Click “ Read EEPROM User” button to start to read data
from controller.
STEP 5 : The bar indicates the reading status.
STEP 5 : After completed, name the data in . EEP le format and save.
Read EEPROM Data of H Series Controller
4-3
4. Software Operation
SOYAL Software Series
ISP Tool
SOYAL TECHNOLOGY CO., LTD
08
1
5
2
3
4
STEP 1 : Select the COM Port of the actual connected device.
STEP 2 : Select the Model name according to the device you are using
( AR-888-H / Node ID 001 as example).
STEP 3 : Enter the Node ID of the controller.
STEP 4 : Click “ Write EEPROM User” button.
STEP 5 : Select the data .EEP File you want to write and start.
Write EEPROM Data of H Series Controller
4-4
4. Software Operation
SOYAL Software Series
ISP Tool
SOYAL TECHNOLOGY CO., LTD 09
STEP 6 : Until the progress bar is completely green , it means the writing
program is completed.
4. Software Operation / 5. Reference
FAQ
YouTube Videos
5-1
5-2
How to read the card user data from 721H mode 6 and then write into another 721H?
Why one error message File Type didn´t Match the Target CPUUpdate ISP
Tools to latest version,Please!:721C?
How to reset master code if I forgot it ?
How do I upgrade AR-401E firmware?
Firmware UpdatingISP Tools & UDP Updater Setting step
5. Reference
SOYAL Software Series
ISP Tool
SOYAL TECHNOLOGY CO., LTD
10
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Soyal ISP Tool Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI