H3C SecPath NSQM2QG2GP40 User manual

  • Hello! I am an AI chatbot trained to assist you with the H3C SecPath NSQM2QG2GP40 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Manual version: 6PW103-20190312 BOM: 3123A1N8
i
H3C SecPath NSQM2QG2GP40 interface module
1 Identifier
The module identifier NSQM2QG2GP40 is in the upper right corner of the front panel.
2 About the module
The NSQM2QG2GP40 interface module provides four 1000BASE-X SFP fiber ports and two
40GBASE-R QSFP+ fiber ports. By using this module with interface switch modules, the device is
capable of providing security for 100G networks.
3 Specifications
Figure 1 Front panel
(1) 1000BASE-X SFP fiber port LEDs (2) 40GBASE-R QSFP+ fiber port LEDs
(3) Ejector lever (4) 40GBASE-R QSFP+ fiber ports
(5) 1000BASE-X SFP fiber ports (6) Captive screw
Table 1 Module specifications
Item Specification
Dimensions (H × W × D) 37.4 × 173.5 × 191.9 mm (1.47 × 6.83 × 7.56 in)
Power consumption 2 W to 10 W
Net weight 0.7 kg (1.54 lb)
Hot swapping Not supported
Ports
4 × 1000BASE-X SFP fiber ports
2 × 40GBASE-R QSFP+ fiber ports
Connector type
LC
MPO
Ambient temperature
Operating: 0°C to 45°C (32°F to 113°F)
Storage: –40°C to +70°C (–40°F to +158°F)
Manual version: 6PW103-20190312 BOM: 3123A1N8
ii
Item Specification
Ambient humidity
Operating: 5% RH to 95% RH, noncondensing
Storage: 5% RH to 95% RH, noncondensing
Transmission rate
SFP fiber port: 1.25 Gbps
QSFP+ fiber port: 41.25 Gbps
Transmission medium and max
transmission distance
1000BASE-X SFP fiber port: see Table 2.
40GBASE-R QSFP+ fiber port: see Table 3
Compatible interface switch modules
and slots
NSQM1MBFEA0 interface switch module (slots 1 and 2)
NSQM2MBFDA0 interface switch module (slots 1 and 2)
NSQM2MBFEA0 interface switch module (slots 1 and 2)
The 1000BASE-X SFP fiber ports support SFP transceiver modules in Table 2.
Table 2 SFP transceiver modules available for the 1000BASE-X-SFP fiber ports
Module
Central
wavelength
Connector
type
Cable specifications
Maximum
transmission
distance
SFP-GE-SX-M
M850-A
850 nm LC 50/125 µm, MMF 550 m (1804.46 ft)
SFP-GE-LX-SM
1310-A
1310 nm LC 9/125 µm, SMF 10 km (6.21 miles)
SFP-GE-LH40-
SM1310
1310 nm LC 9/125 µm, SMF 40 km (24.85 miles)
SFP-GE-LH40-
SM1550
1550 nm LC 9/125 µm, SMF
40 km (24.85 miles)
SFP-GE-LH80-
SM1550
1550 nm LC 9/125 µm, SMF
80 km (49.71 miles)
SFP-GE-LH100
-SM1550
1550 nm LC 9/125 µm, SMF
100 km (62.14 miles)
The 40GBASE-R QSFP+ fiber ports support QSFP+ transceiver modules in Table 3.
Table 3 QSFP+ transceiver modules available for the 40GBASE-R QSFP+ fiber ports
Module
Central
wavelength
Connector
type
Cable
specifications
Modal
bandwidth
Maximum
transmission
distance
QSFP-40G-SR
4-MM850
850 nm MPO 50/125 µm, MMF
2000
(MHz*km)
100 m (328.08 ft)
QSFP-40G-LR4
-WDM1300
1310 nm LC 9/125 µm, SMF N/A 10 km (6.21 miles)
QSFP-40G-CS
R4-MM850
850 nm MPO 50/125 µm, MMF
2000
(MHz*km)
300 m (984.25 ft)
4 LEDs
The module provides a LED for each 1000BASE-X SFP port and 40GBASE-R QSFP+ port to
indicate their operating status.
Manual version: 6PW103-20190312 BOM: 3123A1N8
iii
Table 4 1000BASE-X SFP port LED description
Status Description
Flashing The port is sending or receiving data.
On A link is present on the port.
Off No link is present on the port.
Table 5 40GBASE-R QSFP+ port LED description
Status Description
Flashing The port is sending or receiving data.
On A link is present on the port.
Off No link is present on the port.
5 Installing or removing the interface module
CAUTION:
Wear a reliably-grounded ESD wrist strap or ESD gloves before you install or remove the
interface module.
Do not touch the components on the interface module.
The interface module is not hot swappable. You must first power off the device before installing
or removing the interface module.
5.1
Installing the interface module
To install the interface module on the device, you must first install the module on an interface switch
module.
To install the interface module:
1. Install the interface module on an interface switch module.
a. Place the interface switch module on an antistatic workbench with its PCB components
facing up.
If the interface switch module has been installed on the device, first remove it from the
device. For the removal procedure, see "Removing the interface module."
b. Remove the filler panel from the target slot on the interface switch module.
c. Insert the interface module slowly into the target slot along the guide rails.
d. Use a Phillips screwdriver to fasten the captive screw on the interface module to secure it in
the interface switch module.
Manual version: 6PW103-20190312 BOM: 3123A1N8
iv
Figure 2 Installing the interface module on an interface switch module
2. Install the interface switch module on the device.
a. Open the ejector levers on the interface switch module and then push the module slowly
into the slot along the guide rails.
b. Close the ejector levers to ensure that the module is in close contact with the backplane.
c. Use a Phillips screwdriver to fasten the captive screws on the interface switch module to
secure the module in the device.
Figure 3 Installing the interface switch module on the device
5.2
Removing the interface module
To remove the interface module, first remove the interface switch module where the interface module
is attached from the device.
To remove the interface module:
1. Remove the interface switch module from the device.
a. Use a Phillips screwdriver to loosen the captive screws on the interface switch module until
all pressure is released.
b. Open the ejector levers to disengage the module from the backplane, and then pull the
module slowly out of the slot along the guide rails.
Manual version: 6PW103-20190312 BOM: 3123A1N8
v
2. Remove the interface module from the interface switch module.
a. Use a Phillips screwdriver to loosen the captive screw on the interface module until all
pressure is released.
b. Open the ejector lever to disengage the module from the interface switch module, and then
pull the module slowly out of the slot along the guide rails.
3. Place the interface module on an anti-static workbench or in an anti-static bag with its PCB
components facing up.
4. If you are not to install a new interface module, install a filler panel in the slot to prevent dust and
ensure good ventilation.
Copyright © 2019 New H3C Technologies Co., Ltd.
The information in this document is subject to change without notice.
/