American Standard 2948LC-RHO.020 Installation guide

Type
Installation guide

This manual is also suitable for

L1
© 2021 AS America, Inc.
spec_2948LC-RHO/LHO Mainstream60x32 8Jet IA-WP 2/21
Mainstream
®
60" x 32" 8 Jet Integral
Apron Whirlpool
Alcove Installation
Mainstream
®
60" x 32" 8 Jet Integral Apron Whirlpool
2948LC-RHO.020 Mainstream 60x32 8 Jet Whirlpool,
Right Hand Drain Outlet
2948LC-LHO.020 Mainstream 60x32 8 Jet Whirlpool,
Left Hand Drain Outlet
• Acrylic with berglass reinforcement
• Features EverClean
®
whirlpool system which
suppresses the growth of unsightly algae, fungus, mold
and mildew.
• Integral apron with removable access panel
• Three-sided, tiling/water retention ange
• 1.4 HP self-draining pump/motor with dry run seal
• 8 Fully adjustable clean jets
• Side-mounted On/Off control
• 2 Silent air volume controls
• Textured, slip-resistant tub oor
• Features easy install heater connection system.
Safe-T-Heater, model 9075.120.000, sold separately
• 1699500.020 Mainstream Deep Soak Drain Kit required,
sold separately
• Limited lifetime warranty
Nominal Dimensions:
60" x 32" x 21-1/2"
(1524 x 813 x 546 mm)
Compliance Certifications -
Meets or Exceeds the Following Specifications:
Underwriters Laboratories - Hydromassage
Bathtubs UL 1795
• ASME A112.19.7M for Whirlpool Appliances
• ANSI Z124.1 for Plastic Bathtubs
• ASTM E162 for Flammability
• NFPA 258 for Smoke Density
Components Required:
Mainstream Whirlpool Drain Kit: 1699500.020
Custom Accessories Available:
Safe-T-Heater: 9075.120.000
NOTE: Whirlpool Heater is designed to maintain water
temperature during operation. It will not heat cold water
to desired bathing temperature.
SEE REVERSE FOR ROUGHING-IN DIMENSIONS
AND PRODUCT SPECIFICATIONS
L2
© 2021 AS America, Inc.
spec_2948LC-RHO/LHO Mainstream60x32 8Jet IA-WP 2/21
Mainstream
®
60" x 32" 8 Jet Integral
Apron Whirlpool
Alcove Installation
NOTES:
BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND, OR PENINSULA TYPE INSTALLATION. SUP-
PORT OF BATH BY SUMP BEDDING. SUPPORT AND ENCLOSING MATERIAL BY OTHERS.
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL INFORMATION.
FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.
IMPORTANT: Dimensions of xtures are nominal and may vary within the range of tolerances established by ANSI Standard Z124.1
These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided leaet.
60"
(1524 mm)
32"
(813 mm)
7-1/2"
(191 mm)
10-1/2"
(267 mm)
3"
(76 mm)
13-1/2"
(343 mm)
32"
(813 mm)
19-1/8"(A)
(486 mm)
20-1/2"(H)
(521 mm)
21-1/2"
(546 mm)
C/L OF
OVERFLOW
16"
(406 mm)
6"
(152 mm)
CUT OUT IN FLOOR
FOR DRAIN
DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE
OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z124.1 AND A112.19.7
GENERAL SPECIFICATIONS FOR 2928LC WHIRLPOOL
WHIRLPOOL ELECTRICAL SPECIFICATIONS
PUMP 1.4 HPR, 9.7 AMPS,120V.
60 x 32 x 20-1/2 (1524 x 813 x 521mm)
92 Lbs. (42 Kg.)
675 Lbs. (306 Kg.)
70 Gal. (265 L.)
39 Gal. (148 L.)
42 x 22 (1067 x 559mm)
53 x 25-1/2 (1346 x 648mm)
17-1/2 (445mm)
51 Lbs./Sq.Ft. (247 Kgs./Sq.m)
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
Model 2948LC-RHO Shown
  • Page 1 1
  • Page 2 2

American Standard 2948LC-RHO.020 Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI