Greenheck Fan none User manual

Type
User manual

This manual is also suitable for

Greenheck Fan Duct Smoke Detector none

The Greenheck Fan Duct Smoke Detector none is a device that can be used to detect smoke in ducts. It is designed to be installed in ducts that are used to transport air in heating, ventilating, and air conditioning (HVAC) systems. The detector is capable of detecting smoke particles as small as 0.1 microns in size, and it can be used to activate a variety of alarms and controls, such as fire dampers, fans, and smoke evacuation systems.

The detector is easy to install and maintain, and it is designed to be reliable and accurate. It is also UL Classified and Canadian safety standards approved.

Greenheck Fan Duct Smoke Detector none

The Greenheck Fan Duct Smoke Detector none is a device that can be used to detect smoke in ducts. It is designed to be installed in ducts that are used to transport air in heating, ventilating, and air conditioning (HVAC) systems. The detector is capable of detecting smoke particles as small as 0.1 microns in size, and it can be used to activate a variety of alarms and controls, such as fire dampers, fans, and smoke evacuation systems.

The detector is easy to install and maintain, and it is designed to be reliable and accurate. It is also UL Classified and Canadian safety standards approved.

Part number 465915
Installation Instruction Supplement for
SMD, SESMD, & SSSMD Series
Smoke Dampers and
FSD, FSD-3XXV, SEFSD, & SSFSD Series
Combination Fire Smoke Dampers
with Factory Mounted No Flow Duct Smoke Detectors
UL CLASSIFIED (see complete marking on product)
UL CLASSIFIED to Canadian safety standards (see
complete marking on product)
Standard 555 (Listing #R13317)
Standard 555S (Listing # R13447)
Refer to:
‘Installation Instructions for SMD, SESMD, and
SSSMD Series Leakage Rated Smoke Dampers’
(Part #461338)
or
‘Installation Instructions for CFSD, FSD, DFD,
SEFSD, SSFSD Series Combination Fire Smoke
Dampers’ and (Part#461336) and FSD-3XXV series
(Part #461666) for additional details
NOTES
1. Minimum air velocity for smoke detector operation is
0 fpm. Maximum is 3000 fpm.
2. Model 2151 low profile smoke detector is mounted to a
standard electrical box within the duct. The twist-in/
twist-out head allows easy removal from the base for
quick cleaning and maintenance.
3. Smoke detector specifications are:
Operating temperature rating: 32°F to 120°F (0°C to 49°C)
Operating humidity range: 10% to 93% RH
Operation voltage: 120 VAC
4. Refer to System Sensor, 2151, Installation and Maintenance
Instructions for further installation details.
5. Refer to System Sensor, 2151, Installation and Maintenance
Instructions for maintenance and field tests.
6. System Sensor
3825 Ohio Avenue
St. Charles, IL 60174
Phone: 1-800-736-7672
Fax: 1-630-377-6495
Website: www.systemsensor.com
#10 TEK SCREW
4 X 4 X 2 1/8 HANDI BOX
SMOKE DETECTOR ASSEMBLY
(PRIMARY)
L2
WHITE
MOTOR
SWITCHING DEVICE
(BY OTHERS)
L1
(OVERRIDE)
BROWN
BLACK
ORANGE
BLACK
TOR
YELLOW
YELLOW
YELLOW
YELLOW
SWITCH #1
SWITCH #2
WHITE
BLUE
RED
BLUE
BLACK
BLACK
7
6
13
14
12
10
8
9
RED
11
L2
WHITE
MOTOR
L1
BLACK
OCI
YELLOW
YELLOW
YELLOW
YELLOW
SWITCH #1
SWITCH #2
BLUE
RED
BLUE
BLACK
BLACK
7
6
13
14
12
10
8
9
RED
11
L2
WHITE
MOTOR
L1
BLACK
ORANGE
BLACK
RRL/OCI
BLUE
RED
BLUE
BLACK
BLACK
7
6
13
14
12
10
8
9
RED
11
YELLOW
YELLOW
YELLOW
YELLOW
SWITCH #2
SWITCH #1
L2
WHITE
MOTOR
L1
BLACK
ORANGE
BLACK
RRL
BLUE
RED
BLUE
BLACK
BLACK
7
6
13
14
12
10
8
9
RED
11
Wiring Diagrams
RRL
OCI
RRL/OCI
TOR
(PRIMARY)
L2
WHITE
SWITCHING DEVICE
(BY OTHERS)
L1
(OVERRIDE)
BROWN
BLACK
ORANGE
BLACK
TOR
YELLOW
YELLOW
YELLOW
YELLOW
SWITCH #1
SWITCH #2
WHITE
BLUE
RED
BLUE
BLACK
BLACK
7
6
13
14
12
10
8
9
RED
11
E/P SWITCH
WHITE
RED RED
BLACK
L2
WHITE
L1
OCI
YELLOW
YELLOW
YELLOW
YELLOW
SWITCH #1
SWITCH #2
BLUE
RED
BLUE
BLACK
BLACK
7
6
13
14
12
10
8
9
RED
11
E/P SWITCH
RED RED
BLACK
Wiring Diagrams with
EP Switch
L2
L1
BLACK
ORANGE
RRL
BLUE
RED
BLUE
BLACK
BLACK
7
6
13
14
12
10
8
9
RED
11
E/P SWITCH
WHITE
RED RED
BLACK
L2
WHITE
L1
OCI
YELLOW
YELLOW
YELLOW
YELLOW
SWITCH #1
SWITCH #2
BLUE
RED
BLUE
BLACK
BLACK
7
6
13
14
12
10
8
9
RED
11
E/P SWITCH
RED RED
BLACK
RRL
OCI
RRL/OCI
TOR
Copyright ©2006 Greenheck Fan Corporation
465915 No Flow Smoke Detector IOM
Rev. 3 November 2006
  • Page 1 1
  • Page 2 2
  • Page 3 3

Greenheck Fan none User manual

Type
User manual
This manual is also suitable for

Greenheck Fan Duct Smoke Detector none

The Greenheck Fan Duct Smoke Detector none is a device that can be used to detect smoke in ducts. It is designed to be installed in ducts that are used to transport air in heating, ventilating, and air conditioning (HVAC) systems. The detector is capable of detecting smoke particles as small as 0.1 microns in size, and it can be used to activate a variety of alarms and controls, such as fire dampers, fans, and smoke evacuation systems.

The detector is easy to install and maintain, and it is designed to be reliable and accurate. It is also UL Classified and Canadian safety standards approved.