Danfoss EvoFlat Operating instructions

Type
Operating instructions

Danfoss EvoFlat is a substation designed to connect your house installation to a frost-free room where the temperature does not exceed 50 °C and the humidity does not exceed 80%. It is suitable for various energy sources, such as district heating, central boiler (gas, oil, biomass, etc.), solar, heat pump, or a combination of them. The EvoFlat is equipped with safety valves to prevent accidents and injuries. Do not cover or wall up the substation or in any other way block the entrance to the station.

Danfoss EvoFlat is a substation designed to connect your house installation to a frost-free room where the temperature does not exceed 50 °C and the humidity does not exceed 80%. It is suitable for various energy sources, such as district heating, central boiler (gas, oil, biomass, etc.), solar, heat pump, or a combination of them. The EvoFlat is equipped with safety valves to prevent accidents and injuries. Do not cover or wall up the substation or in any other way block the entrance to the station.

InstallationGuide
EvoFlat
1.0TableofContents
1.0TableofContents.............................................1
2.0Safetynotes.....................................................2
2.1SafetyNotesgeneral............................................2
3.0Mounting........................................................3
3.1Mounting...........................................................3
3.2Start-up..............................................................4
3.3Electricalconnections.............................................5
4.0Design.............................................................6
4.1Design,A............................................................6
4.2Schematic,Adiagram.............................................7
4.3Design,Std..........................................................8
4.4Schematic,Std.diagram..........................................9
5.0Controls..........................................................11
5.1Controls.............................................................11
5.2Maintenance........................................................15
6.0Troubleshooting..............................................16
6.1Troubleshootingingeneral......................................16
6.2TroubleshootingDHW............................................16
6.3TroubleshootingHE...............................................17
6.4Disposal.............................................................18
7.0Declaration......................................................19
7.1Declarationofconformity........................................19
DanfossDistrictEnergy
VI.IQ.C1.02
DEN-LDS
1
InstallationGuideEvoFlat
2.0Safetynotes
2.1SafetyNotesgeneral
Thefollowinginstructionsrefertothestandarddesignof
substation.
Thisoperatingmanualshouldbereadcarefullybeforeinstallation
andstart-upofthesubstation.Themanufactureracceptsno
liabilityfordamageorfaultsthatresultfromnon-compliancewith
theoperatingmanual.Pleasereadandfollowalltheinstructions
carefullytopreventaccidents,injuryanddamagetoproperty.
Assembly,start-upandmaintenanceworkmustbeperformedby
qualiedandauthorizedpersonnelonly.
Pleasecomplywiththeinstructionsissuedbythesystem
manufacturerorsystemoperator.
Corrosionprotection
Allpipesandcomponentsaremadeofstainlesssteelandbrass.
Themaximumchloridecompoundsoftheowmediumshouldnot
behigherthan150mg/l.
Theriskofequipmentcorrosionincreasesconsiderablyifthe
recommendedlevelofpermissiblechloridecompoundsis
exceeded.
Energysource
Thesubstationisdesignedtobeconnectedtodecentralized
heatinginstallationswithvariousenergysources,suchasdistrict
heating,centralboiler(gas,oil,biomass,etc.),solar,heatpumpora
combinationbetweenthemiftheoperatingconditionsallowit.
Application
Thesubstationisdesignedtobeconnectedtothehouse
installationinafrost-freeroom,wherethetemperaturedoesnot
exceed50°Candthehumiditydoesnotexceed80%.Donotcover
orwallupthesubstationorinanyotherwayblocktheentrance
tothestation.
Choiceofmaterial
Choiceofmaterialsalwaysincompliancewithlocallegislation.
Safetyvalve(s)
Werecommendmountingofsafetyvalve(s),however,alwaysin
compliancewithlocalregulations.
Connection
Thesubstationmustbeequippedwithfeaturesthatensurethat
thesubstationcanbeseparatedfromallenergysources(also
powersupply).
Emergency
Incaseofdangeroraccidents-re,leaksorotherdangerous
circumstances-interruptallenergysourcestothestationif
possible,andseekexperthelp.
Incaseofdiscolouredorbad-smellingdomestichotwater,closeall
shut-offvalvesonthesubstation,informtheoperatingpersonnel
andcallforexperthelpimmediately.
Storage
Anystorageofthesubstationwhichmaybenecessarypriorto
installationshouldbeinconditionswhicharedryandheated.
Authorizedpersonnelonly
Assembly,start-upandmaintenanceworkmustbeperformedby
qualiedandauthorizedpersonnelonly.
Pleaseobserveinstructionscarefully
Toavoidinjurytopersonsanddamagetothedevice,itisabsolutely
necessarytoreadandobservetheseinstructionscarefully.
Warningofhighpressureandtemperature
Beawareoftheinstallationspermissiblesystempressureand
temperature.
Themaximumtemperatureoftheowmediuminthesubstationis
95°C.
Themaximumoperatingpressureofthesubstationis10bar.
Theriskofpersonsbeinginjuredandequipmentdamagedincreases
considerablyiftherecommendedpermissibleoperatingparameters
areexceeded.
Thesubstationinstallationmustbeequippedwithsafetyvalves,
however,alwaysinaccordancewithlocalregulations.
Warningofhotsurface
Thesubstationhasgothotsurfaces,whichcancauseskinburns.
Pleasebeextremelycautiousincloseproximitytothesubstation.
Powerfailurecanresultinthemotorvalvesbeingstuckinopen
position.Thesurfacesofthesubstationcangethot,whichcancause
skinburns.Theballvalvesondistrictheatingsupplyandreturnshould
beclosed.
Warningoftransportdamage
Beforesubstationinstallation,pleasemakesurethatthesubstation
hasnotbeendamagedduringtransport.
IMPORTANT-Tighteningofconnections
Duetovibrationsduringtransportallangeconnections,screwjoints
andelectricalclampandscrewconnectionsmustbecheckedand
tightenedbeforewaterisaddedtothesystem.Afterwaterhasbeen
addedtothesystemandthesystemhasbeenputintooperation,
re-tightenALLconnections.Checkthatallhairpinsinclickconnections
arecompletelypushedin.
2
DEN-LDS
VI.IQ.C1.02
DanfossDistrictEnergy
InstallationGuideEvoFlat
3.0Mounting
3.1Mounting
Installationmustbeincompliancewithlocalstandardsand
regulations.
HeatSource(HS)-Inthefollowingsections,HSreferstotheheat
sourcewhichsuppliesthesubstations.Avarietyofenergysources,
suchasoil,gasorsolarpower,couldbeusedastheprimarysupply
toDanfosssubstations.Forthesakeofsimplicity,HScanbetaken
tomeantheprimarysupply.
Authorizedpersonnelonly
Assembly,start-upandmaintenanceworkmustbeperformedby
qualiedandauthorizedpersonnelonly.
3.1.1Installation
Mounting:
Adequatespace
Pleaseallowadequatespacearoundthesubstationformounting
andmaintenancepurposes.
Orientation
Thestationmustbemountedsothatcomponents,keyholes
andlabelsareplacedcorrectly.Ifyouwishtomountthestation
differentlypleasecontactyoursupplier.
Drillings
Wheresubstationsaretobewall-mounted,drillingsareprovided
inthebackmountingplate.
Labelling
Eachconnectiononthesubstationislabelled.
Beforeinstallation:
Cleanandrinse
Priortoinstallation,allsubstationpipesandconnectionsshouldbe
cleanedandrinsed.
Thightening
Duetovibrationduringtransport,allsubstationconnections
mustbecheckedandtightenedbeforeinstallation.Checkthatall
hairpinsinclickconnectionsarecompletelypushedin.
Unusedconnections
Unusedconnectionsandshut-offvalvesmustbesealedwitha
plug.Shouldtheplugsrequireremoval,thismustonlybedoneby
anauthorizedservicetechnician.
Installation:
Strainer
Ifastrainerissuppliedwiththestationitmustbettedaccording
toschematicdiagram.Pleasenotethatthestrainermaybe
suppliedloose.
Connections
Connectiontothehouseholdinstallationanddistrictheatingpipes
connectionsmustbemadeusingthreaded,angedorwelded
connections.
Theinternalconnectionsofthesubstationismadebyclick-t
connections(see5.1.11).
Keyholeformounting.
DanfossDistrictEnergy
VI.IQ.C1.02
DEN-LDS
3
InstallationGuideEvoFlat
3.2Start-up
Start-up,Directheating
Theshut-offvalvesshouldbeopenedandtheunitobservedas
itentersservice.Visualcheckingshouldconrmtemperatures,
pressures,acceptablethermalexpansionandabsenceofleakage.
Iftheheatexchangeroperatesinaccordancewithdesign,itcanbe
puttoregularuse.
Afterwaterhasbeenaddedtothesystemandthesystemhasbeen
putintooperation,re-tightenALLconnections.Checkthatall
hairpinsinclickconnectionsarecompletelypushedin.
Re-thightenconnections
Afterwaterhasbeenaddedtothesystemandthesystemhasbeen
putintooperation,re-tightenALLconnections.Checkthatallhairpins
inclickconnectionsarecompletelypushedin.
Start-up,Heatingwithmixingloop
Start-up:
1:Pumpspeed
Setthepumptoitshighestspeedofrotationbeforestart-up.On
radiatorsystems,theselectorswitchisnormallysetin“Variable
curve/Proportionalcurvesetting,inmax.pos. .Foroorheating
systems,theselectorswitchisnormallysetinConstantcurve
setting,inmax.pos. .
2:Startpump
Startthepumpandheatthroughthesystem.
3:Openshut-offvalves
Theshut-offvalvesshouldthenbeopenedandtheunitobserved
asitentersservice.Visualcheckingshouldconrmtemperatures,
pressures,acceptablethermalexpansionandabsenceofleakage.
Ifthesystemoperatesinaccordancewithdesign,itcanbeput
toregularuse,-alwaystakingintoaccounttheconditionsinthe
building.
4:Ventsystem
Switchoffthepumpandventtheinstallationafterthesystemhas
beenwarmedup.Pleasenotethatsomepumptypesfeaturea
built-inventingfunction.Forotherstheinstallationcanbevented
byusingaventvalveinthesubstationorontheradiators,or,if
appropriate,theairvalveatthehighestpointofthesystemFor
additionalinformation,pleasereferstotheenclosedpumpand
manual.
5:Adjustpumpspeed
Setthepumptothelowestpossibleposition,dependingonthe
heatingrequirementforthebuilding-takingintoaccountaspects
suchascoolingandpowerconsumption.
Iftheheatingrequirementincreasesthepumpsettingcanbe
changedbymeansoftheselectorswitch.Pleaserefertothe
enclosedinstructionmanualfordetailedinformationaboutsetting
ranges.
Inthesummer,youcanswitchoffthepowertothepumpatthe
mainsifyouwanttosaveelectricitybynotheatingyourhome.It
shouldbeensuredthatnoinappropriatehydraulicsituationwill
occur,whenthepowertoyourpumpisturnedoff.
Forstart-upandventingseeaboveandtheenclosedpump
manual.
Re-thightenconnections
Afterwaterhasbeenaddedtothesystemandthesystemhasbeen
putintooperation,re-tightenALLconnections.Checkthatallhairpins
inclickconnectionsarecompletelypushedin.
Pump
Thepumpmustbeswitchedoffduringsystemll.
4
DEN-LDS
VI.IQ.C1.02
DanfossDistrictEnergy
InstallationGuideEvoFlat
3.3Electricalconnections
Beforemakingelectricalconnections,pleasenotethe
following:
Safetynotes
Pleasereadtherelevantpartsofthesafetynotes.
230V
Thesubstationmustbeconnectedto230VACandearth.
Disconnection
Thesubstationmustbeelectricallyconnectedsothatitcanbe
disconnectedforrepairs.
Grounding/potentialcompensation
Thestationshouldbeconnectedtoagroundingpointontheright
sideofthestationmountingrail.
Authorizedelectrician
Electricalconnectionsmustbemadebyanauthorizedelectricianonly.
Localstandards
Electricalconnectionsmustbemadeinaccordancewithcurrent
regulationsandlocalstandards.
DanfossDistrictEnergy
VI.IQ.C1.02
DEN-LDS
5
InstallationGuideEvoFlat
4.0Design
4.1Design,A
Yoursubstationmightlookdifferentthanthesubstationshown.
Designdescription
FSSA26-40(leftphoto)
MSSA26-40(rightphoto)
2
Plateheatexchanger
2
Plateheatexchanger
5
Strainer
5
Strainer
21
Returntemperaturelimiter
6
Checkvalve
23
Sensorpocket
10
Circulationpumpmixingcircuit
24
Fittingpiece,energymeter
23
Sensorpocket
38
Hotwater/dpcontroller
24
Fittingpiece,energymeter
40
Summerby-pass
29
Actuator
58
Fittingpiece,watermeter
30
ValveHE
59A
Fittingpiece,watermeter
38
Hotwater/dpcontroller
59BFittingpiece,watermeter
40
Summerby-pass
64
Flowlimiter
54
Safetyswitch
58
Fittingpiece,watermeter
59A
Fittingpiece,watermeter
59BFittingpiece,watermeter
64
Flowlimiter
6
DEN-LDS
VI.IQ.C1.02
DanfossDistrictEnergy
InstallationGuideEvoFlat
4.2Schematic,Adiagram
FSSA26-40
DHW
DCW
DCW
HS
Supply
HE
Supply
HS
Return
HE
Return
MSSA26-40
DHW
DCW
DCW
HS
Supply
HE
Supply
HS
Return
HE
Return
Yoursubstationmightlookdifferentthantheschematicdiagramshown.
DanfossDistrictEnergy
VI.IQ.C1.02
DEN-LDS
7
InstallationGuideEvoFlat
4.3Design,Std.
Yoursubstationmightlookdifferentthanthesubstationshown.
Designdescription
FSS26-40(leftphoto)
MSS26-40(rightphoto)
2
Plateheatexchanger
2
Plateheatexchanger
5
Strainer
5
Strainer
21
Returntemperaturelimiter
6
Checkvalve
23
Sensorpocket
10
Circulationpumpmixingcircuit
24
Fittingpiece,energymeter
23
Sensorpocket
38
Hotwater/dpcontroller
24
Fittingpiece,energymeter
40
Summerby-pass
29
Actuator
59
Fittingpiece,watermeter
30
ValveHE
38
Hotwater/dpcontroller
40
Summerby-pass
59
Fittingpiece,watermeter
8
DEN-LDS
VI.IQ.C1.02
DanfossDistrictEnergy
InstallationGuideEvoFlat
4.4Schematic,Std.diagram
FSS26-40
DHW
DCW
DCW
HS
Supply
HE
Supply
HS
Return
HE
Return
MSS26-40
DHW
DCW
DCW
HS
Supply
HE
Supply
HS
Return
HE
Return
Yoursubstationmightlookdifferentthantheschematicdiagramshown.
DanfossDistrictEnergy
VI.IQ.C1.02
DEN-LDS
9
InstallationGuideEvoFlat
4.4.1EVOFlatTechnicalparameters
Technicalparameters
Nominalpressure:FSSPN10/PN10andMSSPN6/PN10
Max.DHsupplytemperature:
95°C
Min.DCWstaticpressure:
1.0bar
Brazingmaterial(HEX):
Copper
Heatexchangerstestpressure:25bar
10
DEN-LDS
VI.IQ.C1.02
DanfossDistrictEnergy
InstallationGuideEvoFlat
5.0Controls
5.1Controls
5.1.1TPCmultifunctionalcontroller
Multifunctionalcontrollerwithintegratedzonevalve,airvent,
differentialpressureandDHWtemperaturecontroller.
DHWtemperaturecontrol
Byturningthehandlefortemperaturetemperaturein(+/MAX)
directionthetemperatureisincreased,byturningitin(-/MIN)
directionthetemperatureisdecreased.
Settingrange40-60°C.
DHWtemperatureshouldbeadjustedto45-50°C,asthisprovides
optimalutilizationofDHwater.AtDHWtemperaturesabove55°C
thepossibilityoflimescaledepositsincreasessignicantly.
Differentialpressurecontroller
Thedifferentialpressurecontrollerequalizesthehighuctuations
inpressurearrivingfromtheheatsource,ensuringconstant
operatingpressure
Zonevalve
Thestationissuppliedwithazonevalveandthuspreparedfor
mountingofathermalactuatorTWA-K,whichenablesconnection
ofanelectronicprogrammableroomthermostatTP7000.
5.1.2Airvent
Airvent
Thestationshouldbeventedduringstartup.
DanfossDistrictEnergy
VI.IQ.C1.02
DEN-LDS
11
InstallationGuideEvoFlat
5.1.3TP7000
TP7000electronic7dayprogrammableroomthermostat.
Signalsfromtheroomthermostatcanbeusedtocontrolzone
valves.
Note:Beforemountingofelectronicprogrammableroom
thermostat,thermoactuatorTWA-Kmustbemountedonthezone
valve.
5.1.4Strainer
Strainersshouldbecleanedregularlybyauthorizedpersonnel.The
frequencyofcleaningwoulddependonoperatingconditions.
5.1.5Summerbypass
Thebypassthermostatisdesignedtokeepthesupplylinewarm.
Settingrange:10-50°C.
Scalesetting(indicative).
Factorysetting2,5.
12
DEN-LDS
VI.IQ.C1.02
DanfossDistrictEnergy
InstallationGuideEvoFlat
5.1.6Mixingloop
Themixingloopcreatesasuitabletemperaturelevele.g.foroor
heating.
5.1.7FTCcontrol
TheFTCcontrolsthemixingloopHEsupplytemperature.
Settingrange15-50°C.
Thesettingvaluesmayvarydependingontheoperating
conditions.Itisimportanttosetthesupplytemperaturetothe
radiatorsaslowpossible.
NB!Forhousesthatareheatedexclusivelywithoorheating.
ALWAYSrefertotheinstructionsfromtheoorsupplier.
Factorysetting:50°C.
5.1.8Safetythermostat
ThesafetythermostatwillshutthezonevalveiftheHEsupply
temperatureisabove55°C.
5.1.9Safetyvalve
Thepurposeofthesafetyvalveistoprotectthesubstationfrom
excessivepressure.
Theblow-offpipefromthesafetyvalvemustnotbeclosed.The
blow-offpipeoutletshouldbeplacedsothatitdischargesfreely
anditispossibletoobserveanydrippingfromthesafetyvalve.
Itisrecommendedtochecktheoperationofsafetyvalvesat
intervalsof6months.Thisisdonebyturningthevalveheadin
directionindicated.
DanfossDistrictEnergy
VI.IQ.C1.02
DEN-LDS
13
InstallationGuideEvoFlat
5.1.10ReturntemperaturelimiterFJVR(10-55°C)
ThereturnlimitertypeFJVRautomaticallycontrolsthereturn
temperaturefromheatingsystem.
Thereturntemperaturelimitershouldbesettotherequired
maximumreturntemperature,incompliancewiththelocal
demands.
Factorysetting:3.
5.1.11Fittingpiece
Thesubstationisequippedwithattingpieceforenergymeter.
Mountingofenergymeters:
1:Closeballvalves
ClosetheballvalvesonDHSupplyandDHReturn,ifthereiswater
onthesystem.
2:Loosennuts
Loosenthenutsonthettingpiece.
3:Removettingpiece
Removethettingpieceandreplaceitwiththeenergymeter.Do
notforgetthegaskets.
4:Tightenconnections
Aftermountingoftheenergymeterremembertocheckand
tightenallthreadedconnections.
5.1.12Sensorpocket
Sensorpocket,energymeter
Thesensoroftheenergymeterismountedinthesensorpockets.
Thesensorpocketisplacedinthestrainer.
14
DEN-LDS
VI.IQ.C1.02
DanfossDistrictEnergy
InstallationGuideEvoFlat
5.1.13Clickconnection
Theclickconnectioncanbedismantledduringservice.
5.2Maintenance
Thesubstationrequireslittlemonitoring,apartfromroutine
checks.Itisrecommendedtoreadtheenergymeteratregular
intervals,andtowritedownthemeterreadings.
RegularinspectionsofthesubstationaccordingtothisInstruction
arerecommended,whichshouldinclude:
Strainers
Cleaningofstrainers.
Meters
Checkingofalloperatingparameterssuchasmeterreadings.
Temperatures
Checkingofalltemperatures,suchasHSsupplytemperatureand
DHWtemperature.
Connections
Checkingallconnectionsforleakages.
Safetyvalves
Theoperationofthesafetyvalvesshouldbecheckedbyturning
thevalveheadintheindicateddirection.
Venting
Checkingthatthesystemisthoroughlyvented.
Inspectionsshouldbecarriedoutminimumeverytwoyears.
SparepartscanbeorderedfromDanfoss.Pleaseensurethatany
enquiryincludesthesubstationserialnumber.
Authorizedpersonnelonly
Assembly,start-upandmaintenanceworkmustbeperformedby
qualiedandauthorizedpersonnelonly.
DanfossDistrictEnergy
VI.IQ.C1.02
DEN-LDS
15
InstallationGuideEvoFlat
6.0Troubleshooting
6.1Troubleshootingingeneral
Intheeventofoperatingdisturbances,thefollowingbasicfeatures
shouldbecheckedbeforecarryingoutactualtroubleshooting:
thesubstationisconnectedtoelectricity,
thestrainerontheHSsupplypipeisclean,
thesupplytemperatureoftheHSisatthenormallevel
(summer,atleast60°C-winter,atleast70°C),
thedifferentialpressureisequaltoorhigherthanthenormal
(local)differentialpressureintheHSnetworkifindoubt,ask
theHSplantsupervisor.
Authorizedpersonnelonly
Assembly,start-upandmaintenanceworkmustbeperformedby
qualiedandauthorizedpersonnelonly.
6.2TroubleshootingDHW
ProblemPossiblecauseSolution
Strainerinsupplyorreturnlineclogged.Cleanstrainer(s).
DHWcirculationpumpoutoforderorwith
toolowsetting.(onlyifDHWcirculation
isinstalled).
Checkcirculationpump.
Defectiveorcloggednon-returnvalve.
Replaceclean.
Noelectricity.OnlyifstationarewithDHW
circulation.
Check.
Scalingoftheplateheatexchanger.
Replacerinseout.
Defectivetemperaturesensors.
Checkreplace.
ToolittleornoDHW.
Defectivecontroller.
Checkreplace.
DCWisbeingmixedwiththeDHW,e.g.in
adefectivethermostaticmixingvalve.
Checkreplace. Hotwaterinsometapsbutnotinall.
DHWcirculationpumpoutoforderorwith
toolowsetting.(onlyifDHWcirculation
isinstalled).
Replaceclean.
Taptemperaturetoohigh;DHWtapload
toohigh.
Thermostaticvalveadjustedtoatoohigh
level.Thermostatisdefect.
Checksetreplace.
Scalingoftheplateheatexchanger.
Replacerinseout.
Temperaturedropduringtapping.
LargerDHWowthanthesubstationhas
beendesignedfor.
ReduceDHWow.
16
DEN-LDS
VI.IQ.C1.02
DanfossDistrictEnergy
InstallationGuideEvoFlat
6.3TroubleshootingHE
ProblemPossiblecauseSolution
Toolittleornoheat.StrainercloggedinHSorHEcircuit
(radiatorcircuit).
Cleangate/strainer(s).
ThelterintheenergymeteronHScircuit
clogged.
Cleanthelter(afterconsultingtheHS
plantoperator).
Defectivedifferentialpressurecontroller.
Replacemaincontroller,TPC.
Sensordefective.Checktheoperationofthethermostat
cleanthevalveseatifrequired.
Automaticcontrols,ifany,wronglysetor
defective-possiblypowerfailure.
Checkifthesettingofthecontroller
iscorrectseeseparateinstructions.
Checkthepowersupply.Temporary
settingofmotortomanual”controlsee
instructionsonautomaticcontrols.
Pumpoutofoperation.Checkifthepumpisreceivingpowerand
thatitturns.Checkifthereisairtrappedin
thepumphousingseepumpmanual.
Thepumpissetattoolowspeedof
rotation.
Setthepumpathigherspeedofrotation.
Airpocketsinthesystem.Venttheinstallationthoroughly.
Limitingofthereturntemperature
adjustedtoolow.
Adjustaccordingtoinstructions.
Defectiveradiatorvalves.
Checkreplace.
Unevenheatdistributioninbuilding
becauseofincorrectlysetbalancingvalves,
orbecausetherearenobalancingvalves.
Adjust/installbalancingvalves.
Diameterofpipetosubstationtoosmallor
branchpipetoolong.
Checkpipedimensions.
Unevenheatdistribution.Airpocketsinthesystem.Venttheinstallationthoroughly.
HSsupplytemperaturetoohigh.
Defectivecontroller.Thecontrollerdoes
notreactasitshouldaccordingtothe
instructions.
Callautomaticcontrolsmanufactureror
replacetheregulator.
Defectivesensoronself-actingthermostat.
Replacethermostat.
HSsupplytemperaturetoolow.
Defectivecontroller.Thecontrollerdoes
notreactasitshouldaccordingtothe
instructions.
Callinautomaticcontrolsmanufactureror
replacecontroller.
Strainerclogged.Cleangate/strainer.
ToohighHSreturntemperature.
Toosmallheatingsurface/toosmall
radiatorscomparedtothetotalheating
requirementofthebuilding.
Increasetotalheatingsurface.
Poorutilizationofexistingheatingsurface.
Defectivesensoronself-actingthermostat.
Makesuretheheatisdistributedevenly
acrossthefullheatingsurfaceopenall
radiatorsandkeeptheradiatorsinthe
systemfromheatingupatthebottom.It
isextremelyimportanttokeepthesupply
temperaturetotheradiatorsaslowas
DanfossDistrictEnergy
VI.IQ.C1.02
DEN-LDS
17
InstallationGuideEvoFlat
possible,whilemaintainingareasonable
levelofcomfort.
Thesystemissinglepipeloop.
Thesystemshouldfeatureelectronic
controlsaswellasreturnsensors.
Pumppressuretoohigh.Adjustpumptoalowerlevel.
Airinsystem.
Ventthesystem.
Defectiveorincorrectlysetradiator
valve(s).Singlepipeloopsystemsrequire
specialone-piperadiatorvalves.
Checkset/replace.
Dirtinthedifferentialpressurecontroller.
Checkcleanout.
Defectivemotorizedvalve,sensoror
automaticcontroller.
Checkreplace.
Noiseinsystem.
Pumppressuretoohigh.Noicefrom
radiatorvalves.
Adjustpumptoalowerlevel.Checkow
direction.
Heatloadtoohigh.
Defectivemotorizedvalve,sensoror
electroniccontroller.
Checkreplace.
6.4Disposal
Disposal
Thisproductshouldbedismantledanditscomponents
sorted,ifpossible,invariousgroupsbeforerecycling
ordisposal.
Alwaysfollowthelocaldisposalregulations.
18
DEN-LDS
VI.IQ.C1.02
DanfossDistrictEnergy
InstallationGuideEvoFlat
7.0Declaration
7.1Declarationofconformity
7.1.1Category0withelectricalequipment
ECDeclarationofConformity
DanfossRedanA/S
Omega7
DK-8382Hinnerup
Denmark
Declaresonoursoleresponsibilitythatthebelowproducts:
EvoFlat
coveredbythisdeclarationareinconformitywiththefollowingdirectives,standardsandothernormative
documents,providedthattheyareusedaccordingtoourinstructions.
EMCDirective2004/108/EC
DS/EN61000-6-12007.Electromagnetic
compatibilityGenericstandard:Immunityfor
residentialcommercialandlightindustry.
DS/EN61000-6-32007.Electromagnetic
compatibilityGenericstandard:Emissionfor
residential,commercial&lightindustry.
PressureEquipmentDirective97/23/EC
Equipmentcategory:0(article3.3).
MachineryDirective2006/42/EC
EN14121-1.SafetyofmachineryRiskassessment
EN60204-1.SafetyofmachineryElectrical
equipmentofmachinesPart1:General
requirements.
Hinnerup2013.09.05
PlaceanddateofissueFinnMortensen
ThomasBruunHansen
DanfossDistrictEnergy
VI.IQ.C1.02
DEN-LDS
19
InstallationGuideEvoFlat
ProducedbyDanfossA/S©09/2013
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Danfoss EvoFlat Operating instructions

Type
Operating instructions

Danfoss EvoFlat is a substation designed to connect your house installation to a frost-free room where the temperature does not exceed 50 °C and the humidity does not exceed 80%. It is suitable for various energy sources, such as district heating, central boiler (gas, oil, biomass, etc.), solar, heat pump, or a combination of them. The EvoFlat is equipped with safety valves to prevent accidents and injuries. Do not cover or wall up the substation or in any other way block the entrance to the station.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI