INSTALLATIONOF APPLIANCE
Theinstallationofthisappliancemustconformwithlocalcodesor,inthe
absence of local codes, with the National Fuel Gas Code, ANSI
Z223.1-LatestEdition,or,inCanada,CAN!CGA-B149InstallationCode,
LatestEdition.
This appliance, when installed, must be electrically grounded in
accordancewith localcodesor,inthe absenceof localcodes,with the
NationalElectricalCodeANSI!NFPANo.70-LatestEdition,or,inCanada,
currentCSAStandardC22.1CanadianElectricalCode,Part1.
All supply piping,exceptas noted, shoulduse commonNational Pipe
Thread (N.P.T.).For all pipe connectionsuse an approvedpipe joint
compoundresistantto theactionof LPgas.
CAUTION:WarrantyisvoidonJenn-Airequipmentinstalledotherthanas
recommendedbymanufacturer.
This applianceis designedfor use with the appliancegas pressure
regulatorsuppliedwiththisappliance.It mustbeinstalledinthe gasway
aheadofthegasmanifoldentrance.Itispresetforusewithnaturalgasand
mustbe converted,as describedon page6, for usewith LP gas. (See
figures10and11.)
This applianceis designedto operateat a pressureof 5 inchesofwater
columnon naturalgasor, if convertedfor usewith LPgas (propaneor
butane),10incheswatercolumn.Makesurethisapplianceissuppliedwith
andadjustedforthetype ofgasforwhich itisdesigned.
Thisappliancewasadjustedatthefactoryforusewithnaturalgas.If,atany
time,this applianceis to be usedwith a differenttype of gas,all ofthe
conversionadjustmentsdescribedon pages5 and7 mustbe madebya
qualifiedservicetechnicianbeforeattemptingto operatethe cooktopon
thatgas.Naturalgasshouldbesuppliedtotheappliancepressureregulator
atalinepressurebetween6and14inchesofwatercolumnor,ifconverted
for LPgas,between11and 14inches.
WARNING: If the line pressuresupplyingthe appliancepressure
regulatorexceeds14"W.C. (anygas),an externalregulatormustbe
installedinthegaslineaheadoftheapplianceregulatorto reducetheI
pressureto no morethan 14" W.C.Failureto do this can result in
mafuncton anddamagetotheapp ance.
Insurethisapplianceisadjustedforthetypeof gassuppliedto itandthat
the gas supplypressureto the applianceregulatoris within the proper
pressurerange.
• Ifthis isa 36" wide model,or if it is a 30" widemodeland no other
applianceis to be installed in the cabinetrybelow it, proceedas
instructedunderparagraphI.
• Ifthis is a 30"wide modelanda Jenn-AirModelW30XXXor W131
ElectricWall Ovenis to be installedin cabinetrybelow, proceedas
instructedunderparagraph11.
• Donotremoveprotectivecapfrompipestubatmanifoldentranceuntil
readyto joingassupplypipingto appliance.
NOTE:InCanada,gasutilizationcodesprohibituseofstreetelbows.Use
standardpipe elbowsand makemodificationsto these instructionsas
necessary.
CONNECTINGAPPLIANCETO GAS SUPPLY
A TRAINEDSERVICEMANORGASAPPLIANCEINSTALLERMUST
MAKETHEGASSUPPLYCONNECTION.Leaktestingoftheappliance
shall be conductedby the installeraccordingto the instructions
given.
1. IF NOOTHERAPPLIANCEIS TO BE INSTALLEDBELOWTHIS
COOKTOP
Join theappliancepressureregulatorsuppliedwith thisapplianceto the
entrancethreadsoftheGasManifold.Theapplianceregulatorismarked
with a directionalarrowindicatingcorrectdirectionof gasflow.Ensurethe
applianceregulatoris installedwith the arrowpointingtoward the gas
manifoldentrance.Tightenthe applianceregulatorto 20 to 30 ft-tbsof
torque.
I IMPORTANT approved
Nevertightentomorethan35ft-lbsoftorque.Alwaysusean
pipejointcompoundresistantto theactionof LPgas.
Installtheappliancein itscountercutout.
Makethe gasconnectionto the inletof the appliancepressureregulator
with 1/2"malepipethreads.
Installa manualshut-offvalvein an accessiblelocationinthe gasline
aheadoftheappliancepressureregulatorandexternaltothisappliancefor
the purposeofturningonorshuttingoff gastotheappliance.
Makeadditionalpipeconnectionsasnecessaryaheadoftheshut-offvalve
to thegassupplysource.Assureall pipejointconnectionsaregastight.
IMPORTANT
Applya non-corrosiveleakdetectionfluidto alljointsandfittingsinthe
gasconnectionbetweenthe supplyline shut-offvalveand the range.
Includegasfittingsandjointsin therangeifconnectionsweredisturbed
duringinstallation.Checkforleaks!Bubblesappearingaroundfittings
andconnectionswillindicatealeak.Ifaleakappears,turnoffsupplyline
gasshut-offvalve,tightenconnections,turnonthesupplylinegasshut
offvalve,andretestfor leaks.Nevertestfor gas leakswithan open
flame.
ILLUSTRATIVEGAS SUPPLYPIPING
i (NO OTHER APPLIANCE BELOW COOK'TOP)
BURNER BOX
(REAROFAPPLIANCE)
U MANIFOLDENTRANCE
APPLIANCEPRESSURE
i REGULATOR
I
I
ALL PIPEJOINTS
1/2 N.P.T.
I
ELBOW
MANUAL
SHUTOFF
VALVE
!1---_ _
TOGAS
INLET
FIGURE3