Jenn-Air CCG2523B Installation guide

Type
Installation guide

This manual is also suitable for

SEALEDGAS COOKTOPS
CCG2423AND CCG2523
JGC7430 AND JGC7536
=JENN-AIR
403WEST FOURTHSTREET,NORTH° NEWTON,IA50208
IMPORTANT:DimensionsShown in Both Inchesand Centimeters.
IMPORTANT:Besuretheappliancebeinginstalledis equippedforthegasto besupplied.Referto serialplateon undersideof burnerboxfor this
information.Donotattempttoconvertthis appliancefor usewith a gasotherthanthetype specified.
76.2 cm
"4
Manifold 1 V21' _
Entrance Min. Clearance
3.81cm
37&6"
2%"
8.73__¢m_k,i_ _ _ _ ,_6.67cm
Lf
......_t_,_.._ MAN,FO_I
*II ENTRANClEJ
121/32" -- 27.9 cm
4.21 cm
2" Min.
5.08cm
9/16=
1.43cm
32_
82.71 cm
2" Min.
Manifold
Entrance 53.34 cm
3.81cm
37/16"
8.73 cmL, _
I
I _ MANIFOLD I
T-[-I ENTeNtE I
119/_.. 35.57 cm
4,05 cm
2%"
/
,,__ 6.67 cm
SPECIALWARNING:Improperinstallation,adjustment,alteration,service,maintenanceoruseofappliance
canresultinseriousinjuryor propertydamage.
NOTICETO INSTALLER:LEAVETHESE INSTRUCTIONSWITH THE APPLIANCE.
NOTICETO CONSUMER: RETAINTHESE INSTRUCTIONSFOR FUTURE REFERENCE.
8101 P401-60
(08-01-00)
LOCATIONOF YOUR JENN-AIRAPPLIANCE
Locatethisapplianceawayfromcombustiblematerialssuch aswindow
curtainsandcombustiblewalldecorations.
Minimumhorizontalclearancebetweenthe edge of the applianceand
combustibleconstructionextendingfromthecookingsurfaceto 18" (45.72
cm)abovethecookingsurfaceis
1" (2.54cm)atrear
4" (10.16cm) atsides
(Dimensionsapplyto both30" and36" widemodels)
I a
(2.54 cm)
I
I
I
1½" Min.
(3.81 cm)
(10.16cm)
FIGURE 1
PREPARATIONOF COUNTERTOP
The countertopcutoutmustbe preparedaccordingto the illustrationon
page1oftheseinstructions.
CAUTION:Cutoutdimensionsarecritical.Dimensionsmustbemeasured
andcutaccuratelytowithin+_1/16" (.159cm)to ensureproperfit.
* Jenn-AirOver-the-Rangemicrowaveovens(model#M418and M438)
have been listed by UL for use over Gasand ElectricRanges.When
properlyinstalledataminimumheightof66 inches(167.64cm) fromthe
floorto thetop ofthe microwave,the clearanceto thecookingsurfaceat
the centerwillbe 13-3/4inches(34.93cm).
IMPORTANTPREPARATIONSUGGESTIONS
1. Chamferall exposededgesof decorativelaminatetopreventdamage
fromchipping.
2. Radiuscornersof cutoutandfile to insuresmoothedgesandprevent
cornercracking.
3. Roughedges,insidecornerswhichhavenotbeenroundedandforced
fitscancontributeto crackingofthecountertoplaminate.
4. Countertopmustbesupportedwithin3" (7.62cm)of cutout.
INSTALLINGCABINETRYOVERYOUR
JENN-AIRCOOKTOP
A= 30" (76.2 cm) minimum vertical
clearancebetweencookingsurfaceand
constructionabovethe appliance.This
clearancemay be reducedto not less
than24inches(60.96cm) byprotecting
theundersideofthecornbustibiematerial
or metal cabinet above the cooking
surfacewith notlessthan1/4inch(.635
cm) insulatingmillboard covered with
sheet metalnot less than 0.0122inch
thick*
B = 13" (33.02 cm) maximum depth of
cabinetsinstalledabovecookingtop.
A
I
FIGURE2
Avoid use of cabinets abovecooktop for storage space to eliminate
associatedpotentialhazardssuchasreachingoveropenflames.
INSTALLATIONOF APPLIANCE
Theinstallationofthisappliancemustconformwithlocalcodesor,inthe
absence of local codes, with the National Fuel Gas Code, ANSI
Z223.1-LatestEdition,or,inCanada,CAN!CGA-B149InstallationCode,
LatestEdition.
This appliance, when installed, must be electrically grounded in
accordancewith localcodesor,inthe absenceof localcodes,with the
NationalElectricalCodeANSI!NFPANo.70-LatestEdition,or,inCanada,
currentCSAStandardC22.1CanadianElectricalCode,Part1.
All supply piping,exceptas noted, shoulduse commonNational Pipe
Thread (N.P.T.).For all pipe connectionsuse an approvedpipe joint
compoundresistantto theactionof LPgas.
CAUTION:WarrantyisvoidonJenn-Airequipmentinstalledotherthanas
recommendedbymanufacturer.
This applianceis designedfor use with the appliancegas pressure
regulatorsuppliedwiththisappliance.It mustbeinstalledinthe gasway
aheadofthegasmanifoldentrance.Itispresetforusewithnaturalgasand
mustbe converted,as describedon page6, for usewith LP gas. (See
figures10and11.)
This applianceis designedto operateat a pressureof 5 inchesofwater
columnon naturalgasor, if convertedfor usewith LPgas (propaneor
butane),10incheswatercolumn.Makesurethisapplianceissuppliedwith
andadjustedforthetype ofgasforwhich itisdesigned.
Thisappliancewasadjustedatthefactoryforusewithnaturalgas.If,atany
time,this applianceis to be usedwith a differenttype of gas,all ofthe
conversionadjustmentsdescribedon pages5 and7 mustbe madebya
qualifiedservicetechnicianbeforeattemptingto operatethe cooktopon
thatgas.Naturalgasshouldbesuppliedtotheappliancepressureregulator
atalinepressurebetween6and14inchesofwatercolumnor,ifconverted
for LPgas,between11and 14inches.
WARNING: If the line pressuresupplyingthe appliancepressure
regulatorexceeds14"W.C. (anygas),an externalregulatormustbe
installedinthegaslineaheadoftheapplianceregulatorto reducetheI
pressureto no morethan 14" W.C.Failureto do this can result in
mafuncton anddamagetotheapp ance.
Insurethisapplianceisadjustedforthetypeof gassuppliedto itandthat
the gas supplypressureto the applianceregulatoris within the proper
pressurerange.
Ifthis isa 36" wide model,or if it is a 30" widemodeland no other
applianceis to be installed in the cabinetrybelow it, proceedas
instructedunderparagraphI.
Ifthis is a 30"wide modelanda Jenn-AirModelW30XXXor W131
ElectricWall Ovenis to be installedin cabinetrybelow, proceedas
instructedunderparagraph11.
Donotremoveprotectivecapfrompipestubatmanifoldentranceuntil
readyto joingassupplypipingto appliance.
NOTE:InCanada,gasutilizationcodesprohibituseofstreetelbows.Use
standardpipe elbowsand makemodificationsto these instructionsas
necessary.
CONNECTINGAPPLIANCETO GAS SUPPLY
A TRAINEDSERVICEMANORGASAPPLIANCEINSTALLERMUST
MAKETHEGASSUPPLYCONNECTION.Leaktestingoftheappliance
shall be conductedby the installeraccordingto the instructions
given.
1. IF NOOTHERAPPLIANCEIS TO BE INSTALLEDBELOWTHIS
COOKTOP
Join theappliancepressureregulatorsuppliedwith thisapplianceto the
entrancethreadsoftheGasManifold.Theapplianceregulatorismarked
with a directionalarrowindicatingcorrectdirectionof gasflow.Ensurethe
applianceregulatoris installedwith the arrowpointingtoward the gas
manifoldentrance.Tightenthe applianceregulatorto 20 to 30 ft-tbsof
torque.
I IMPORTANT approved
Nevertightentomorethan35ft-lbsoftorque.Alwaysusean
pipejointcompoundresistantto theactionof LPgas.
Installtheappliancein itscountercutout.
Makethe gasconnectionto the inletof the appliancepressureregulator
with 1/2"malepipethreads.
Installa manualshut-offvalvein an accessiblelocationinthe gasline
aheadoftheappliancepressureregulatorandexternaltothisappliancefor
the purposeofturningonorshuttingoff gastotheappliance.
Makeadditionalpipeconnectionsasnecessaryaheadoftheshut-offvalve
to thegassupplysource.Assureall pipejointconnectionsaregastight.
IMPORTANT
Applya non-corrosiveleakdetectionfluidto alljointsandfittingsinthe
gasconnectionbetweenthe supplyline shut-offvalveand the range.
Includegasfittingsandjointsin therangeifconnectionsweredisturbed
duringinstallation.Checkforleaks!Bubblesappearingaroundfittings
andconnectionswillindicatealeak.Ifaleakappears,turnoffsupplyline
gasshut-offvalve,tightenconnections,turnonthesupplylinegasshut
offvalve,andretestfor leaks.Nevertestfor gas leakswithan open
flame.
ILLUSTRATIVEGAS SUPPLYPIPING
i (NO OTHER APPLIANCE BELOW COOK'TOP)
BURNER BOX
(REAROFAPPLIANCE)
U MANIFOLDENTRANCE
APPLIANCEPRESSURE
i REGULATOR
I
I
ALL PIPEJOINTS
1/2 N.P.T.
I
ELBOW
MANUAL
SHUTOFF
VALVE
!1---_ _
TOGAS
INLET
FIGURE3
2. IFTHISISA30"WIDECOOKTOPANDAJENN-AIR,MODEL
W30XXXORW131,ELECTRICWALLOVENISTOBEINSTALLED
BELOWTHISCOOKTOP.
NOTE1:Thisapplianceanditsgasandelectricalsupplysourcesmustbe
installedbeforethewallovenisinstalled.Seeillustration(ElectricalWiring
Information- page4;figure6)for recommendedelectricalsupplysource
locations.
NOTE2:Itmaybenecessarytoextendgassupplypipingforthisappliance
intoadjacentunder-countercabinetrywhenawallovenisinstalledbelow
thisappliance.
Joina 1/2" NPTpipeelbow(locallyavailable)to themalethreadsatthe
manifoldentrance.Whenjoined,causetheopenthreadsofthe elbowto
facetowardtheleftsideoftheappliance.Installtheapplianceinitscounter
cutout.
Joina 1/2"NPTpipenippletotheelbowusinga pipesectionofsufficient
lengthto extend,horizontally,beyondthe left sideof thewall oven. (To
accomplishthisitmaybenecessarytoextendthepipesectionintoadjacent
cabinetry.)Join additional 1/2" NPT elbow(s) and pipe nipples, as
necessary,to accomplishthefollowing:
Join the outlet of the appliancepressureregulatorsuppliedwith this
applianceto the matethreadsof the newlyinstalledgassupply piping.
Installtheapplianceregulatorinalocationwhichwillbeaccessiblebeside
or belowthewalloven.Insurethe applianceregulatorisinstalledwith its
directionalarrowpointinginthedirectionofgasflow.Tightentheappliance
regulatorto20to 30ft-tbsoftorque.
IMPORTANT approved
Nevertightento morethan35ft-tbsoftorque.Alwaysusean
pipejointcompoundresistanttotheactionof LPgas.
Locateandjoinamanualshut-offvalveinanaccessiblelocationinthegas
lineaheadoftheapplianceregulatorandexternalto theapplianceforthe
purposeofturningonor shuttingoffgasto theappliance.
Makeadditionalpipeconnectionsasnecessaryaheadoftheshut-offvalve
tothegassupplysource.Assureall pipejointconnectionsaregastight.
IMPORTANT
Applya non-corrosiveleakdetectionfluidto all jointsandfittingsinthe
gasconnectionbetweenthesupply lineshut-offvalveandthe range.
Includegasfittingsandjointsintherangeif connectionsweredisturbed
duringinstallation.Checkfor leaks!Bubblesappearingaroundfittings
andconnectionswiltindicatealeak.Ifa leakappears,turnoffsupplyline
gasshut-offvalve,tightenconnections,turnonthesupplylinegasshut
off valve,and retestfor leaks. Nevertest for gasleakswith an open
flame.
ILLUSTRATIVEGASSUPPLY PIPING
(WALLOVENINSTALLEDBELOW30" OOOKTOP)
/ BURNER BOX
.J _ (REAROF APPLIANCE)
MANIFOLD
f
PIPING PASSES THROUGH DIVIDING
_VALL BETWEEN ADJACENT CAB NETS
NIPPLES
(Lengths
I tosuit)
I I ALL PIPE JOINTS1/2 N.P.T.
APPLIANCE MANUAL
I PRESSURE SHUTOFF
REGULATOR VALVE
INLET
APPROXIMATE CROSS SECTION
PROFILE OF WALL OVEN
FIGURE4
Note,regardingFigure4,above:
Forconveniencein servicea groundjointunion(notshown:locally
available)shouldbeincludedin the pipingillustratedin figure4, ina
locationmostpracticalfortheinstallation.Generally,a practicallocation
isinthecabinetbelowthisappliance,nearthemanifoldentrance,rather
thaninanadjoiningcabinet.
Ifthe alternativepiping methodshownin figure5 is selectedfor the
installation,no groundjoint unionisrequired.(Theflexibleappliance
connectorillustratedprovidestheunionjointsnecessaryforservicing.)
Whena dividingwall is presentand a flexibleconnectoris usedit is
recommendedfor convenience,in both installationand service,the
flexibleconnector,itself, passthroughthe dividingwall. Any flexible
connectorusedwiththis appliancemustsatisfyall requirements
statedin the text accompanyingfigure 5.
ALTERNATIVEPIPING METHODSTO CONNECT
APPLIANCETO GAS SUPPLY
A TRAINEDSERVICEMANOR GASAPPLIANCEINSTALLERMUST
MAKETHEGASSUPPLYCONNECTION.Leaktestingoftheappliance
shall be conductedby the installeraccordingto the instructions
given.
Unlessprohibitedbylocalcodesor ordinances,anewA.G.A.- Certified,
flexiblemetalapplianceconnectormaybeusedtoconnectthisappliance
to itsgassupply.Theconnectormusthavean internaldiameternotless
thannominal1/2"NPTpipeandbenomorethan5feet inlength.A 1/2"
NPT x 1/2" flare unionadapteris requiredat each end of the flexible
connector.If a flexibleconnectoris usedassurethatboththeappliance
pressureregulatorand manualshut-offvalvearejoined solidlyto other
permanenthardpiping(eithergassupplyortheappliancemanifold)soas
to bephysicallystationary.Seeillustrationsbelow:
ILLUSTRATIVEALTERNATIVEPIPING
I
_ -'<1- Rare
Union
Adaptor
I
Valve
!
.,_._ " Ngr Pipe
(Stationary
supplypips)
NO APPLIANCE
MOUNTED BELOW
THIS COOKTOP
WALL OVEN MOUNTED
IN CABINETRY BELOW
THIS COOKTOP
I
I_ _=l-- Flare
Union
Adaptor
I
-,91--- ppliancePressu
Regulator,suppli_
(Observe
directionality
of6as Flow)
I
Nipple
I
Valve
I
1-- " NPTPipe
(Stationary
supplypipe)
FIGURE5
CAUTION:Donotattemptto attachtheflexibleconnectordirectlyto an
externalpipethread.Connectionrequiresflareunionadapters.
IMPORTANT
Applya non-corrosiveleakdetectionfluidto alljointsandfittingsinthe
gasconnectionbetweenthe supplyline shut-offvalveand the range.
Includegasfittingsandjointsin therangeifconnectionsweredisturbed
duringinstallation.Checkforleaks!Bubblesappearingaroundfittings
andconnectionswillindicatealeak.Ifaleakappears,turnoffsupplyline
gasshut-offvalve,tightenconnections,turnonthesupplylinegasshut
offvalve,andretestfor leaks.Nevertestfor gas leakswithan open
flame.
PRESSURETESTING
The appliancemustbe isolatedfromthe gas supplypiping systemby
closingits individualmanualshut-offvalveduringanypressuretestingof
the gassupplypipingsystemattest pressuresequalto or lessthan1/2
PSIG(3.5kPa).
This appliance, as well as its individual shut-off valve, must be
disconnectedfrom the gas supply pipingsystemduring any pressure
testingofthesystemattestpressuresinexcessof1/2PSIG(3.5kPa).
When checkingapplianceregulatorfunction, make certainpressureof
naturalgas supply is between6 and 14 inchesof water columnor, if
convertedfor LPgas,between11and 14inches.
ELECTRICALWIRINGINFORMATION
Thisapplianceisequippedwitha groundedtypepowercord.Agrounded
outletmustbeprovided,ttisrecommended,forconvenience,theoutletbe
located(withreferencetofigure6)as inAorB,below:
A. Ifnootherapplianceistobeinstalledbelowthisappliance:withineither
theshadedareaorthecrosshatchedareashowninfigure6.
B. If aModelW30XXXorW131electricovenisto beinstalledbelowthis
appliance,either:
1. withinthecrosshatchedareaoffigure6, or,
2. withinanadjacentcabinet.
CABINET BO'i-rOM
FIGURE6
DimensionA:
W30XXX:5-1/2" (13.97cm)
W131:4" (10.16cm)
If awallovenisto beinstalledbelowthisapplianceandthecounterunit's
outletisto bemountedwithinthe crosshatchedareaoffigure6:
1. The cabinet's lower front panel, belowthe oven, must be made
removableforaccesstothe outlet.
2. A clearancehole for the powercord's plug(1-1/4" (3.18cm) dia is
recommended)mustbeprovidedthroughtheoven'sfloorsupportshelf
and,ifnecessary,throughtheslatssupportingtheshelf.Theclearance
holeshouldbelocatedas nearas practicaltothe rearoftheshelfand
(iftheovenismodelW30XXX)asnearaspracticaltotheleftrearcorner.
3. WhenmodetW30XXXismountedbelowthisappliance,andifthepower
outletfor this applianceis to be locatedin thecrosshatchedarea of
figure 6, it is recommendedthe powercord be routedthroughthe
externalverticalclearancechannelat the left rearof the oven.The
channel'scrosssectionisapproximately4.2" x 2.25" (10.7x5.7cm),
extendingthefull heightofthe oven.(ModelW131providesasimilar,
butlarger,verticalchannelnearthecenterofthemainbackoftheoven.)
If the outlet isto be mountedin eithera leftor rightadjacentcabinet,a
clearancehole,asdescribedabove,mustbe providedinthedividingwall
betweenthe cabinets.Figure4; page 3, illustratesa typical (leftside)
dividingwall.Theclearancehole(notshownin figure4)canbelocatedas
isconvenientinthis leftwallor inthecorrespondingrightwall.
In planningany installation,notethat the freelengthof this appliance's
powercord,extendingbeyonda point3-3/4"(9.53cm)leftof thenominal
centeroftherearwalloftheburnerbox,whenviewedfromthefrontofthe
unit,isapproximately46" (117cm).
WARNING
ELECTRICALGROUNDING INSTRUCTIONS
THIS APPLIANCE IS EQUIPPED WITH A THREE PRONG
GROUNDINGPLUGFORYOURPROTECTIONAGAINSTSHOCK
HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A
PROPERLY GROUNDED RECEPTACLE. DO NOT CUT OR
REMOVETHEGROUNDINGPRONGFROMTHISPLUG.
WARNING
THIS APPLIANCE MUST BE DISCONNECTED FROM ITSI
ELECTRICALSUPPLY AT THE WALL RECEPTACLEBEFORE
SERVC NGTHEAPPLANCE.
CONVERTINGAPPLIANCE FOR USE
WITH LP GAS
WARNING
Propaneconversionistobe performedbyaJENN-AIRAUTHORIZED
SERVICER (or other qualified agency) in accordance with the
manufacturer'sinstructionsand all codes and requirementsof the
authorityhavingjurisdiction.Failuretofollowinstructionscouldresultin
seriousinjuryor propertydamage,Thequalifiedagencyperformingthis
workassumesresponsibilityforthisconversion.
WARNING
Electrical power and gas must be turned off prior to
conversion.
This appliancewas adjustedat the factoryfor usewith naturalgas. To
convertit forusewith LPgas(propaneor butane),eachof thefollowing
modificationsmustbeperformed:
A. Replaceallorificespuds
Step1: Removethegratesandburnerheads.
Step2: Removealuminumventuritube.
Step3: Trima smallpieceof maskingtapeto thesizeof adimeand
affixit overtheendof a5/16" nutdriver.
Step4: Firmlypressthenutdriverovertheorificespud(figure7)and
loosenspud byturningcounterclockwise.Carefully lift nut
driveroutofburnerthroat.Orificespudshouldbecapturedin
therecess.Repeatthisstepforeachburner.
REMOVALOF ORIFICESPUD
ALI_MH',IUM VENTURI _/_ 5,/16"NUT DRIVER
7" ICNITER
FIGURE7
Step5: LocatetheLPorificespudpackettapedtotheundersideofthe
burnerbox.Thespudshavesmall numbersstampedon the
side.This numbercodestheorifice diameterand its correct
burner location.Thefollowingillustrationsshow correctLP
orifice spud location for 4 burner and 5 burner models,
respectively.
INSTALLATIONOF LP ORIFICE SPUDS
4 BURNER MODEL (30"WIDE)
OO
OO
FIGURE8
5 BURNER MODEL (36"WIDE)
©©©
O O
A_T #9219 991-0
FIGURE9
Step6: With the maskingtapestill in placein the recessof the nut
driver,pressan LP orificespudinto the recesssothat it is
snuglycaptured.
Step7: Carefullyinstalltheorificespudintheappropriateburnerthroat
byturningclockwisetotighten.Tightentoatorqueof 15to20
inch-lbs,
Step8: Replacecylindricalaluminumventuritubes, Replaceburner
headsandgrates,Indexeachgratetoits burnerpan,
Step9: Savetheorificesremovedfromthe applianceforfutureuse.
B. Invertcapin appliancepressureregulator
(Seefigures10and 11.)
Withtheapplianceinstalled,theapplianceregulatorshouldbelocated
asshowninfigure3or4. Identifythetypeofapplianceregulatoronthe
unitandfollowtheinstructionsintheappropriateillustration.
CONVERSIONOF MAXITROLAPPLIANCE
PRESSURE REGULATOR
CONVERTER_ _ LP
_z,.A CAP I
NDPIN . J
.J
NAT ! /-_'[_
APPLYDOWNWARD
FINGERPRESSURE
ATDISCEDGESTO
REPLACEPININ_1_
APPLYSIDEWARD
FINGERPRESSURE
I_T0 REMOVEPIN
FROMCAP
NAT IL_P
FIGURE10
CONVERSIONOF HARPER-WYMANAPPLIANCE
PRESSURE REGULATOR
i
NaturalSetting
O
LPSetting
FIGURE11
C. LowFlameAdjustment
(Seefigure12.)
This applianceisshippedfromthefactorywith lowandmediumflame
settingsadjustedfor usewith naturalgas. If further adjustmentis
necessary,orto readjustfor usewith LP,proceedasfollows:
1. Lightburnerandsetcontrolknowfor lowflame.
2. Removecontrolknobfromvalvestem.
CAUTION:NEVERUSEA METALBLADETOPRYKNOBOFF.IF
KNOBCANNOTBEEASILYREMOVED,TUCKTHE FOLDSOFA
CLOTHDISHTOWELUNDERTHEKNOBANDPULLTHETOWEL
UPWARDWITHSTEADY,EVENPRESSURE.
3. Inserta slender,thin-bladescrewdriverintotherecessatcenterof
valvestemandengagebladewithslot inadjustingscrew.
4. Turncenterstemadjustingscrewto setflamesize.
... clockwisetoreduce
... counterclockwiseto increase
5. Replacecontrolknobwhenadjustmentiscompleted.
Properadjustmentwill producea stable,steadyblueflame of minimum
size.Thefinaladjustmentshouldbecheckedbyturningknobfromhighto
lowseveraltimeswithoutextinguishingtheflame.
Thisadjustment,atlowsetting,willautomaticallyprovidetheproperflame
sizeat mediumsetting.
I
CLOCKWISE
TO REDUCE
FLAME SIZE
COUNTERCLOCKWISE
TO INCREASE FLAME
;IZE
1
VALVE
STEM
FIGURE12
After ConversionSteps A, B and C have been completed,checkthe
appearanceofeachburner'sflameattheHiandLosettingsagainstfigure
13.Ifthe flamesappeartoo largeortoo small,revieweachstepto make
sureitwas completedcorrectly.
FLAMEAPPEARANCE ATHIAND LO
Mad
LO_ HI
LO_ HI
Off
Mad
LO_ HI
011
FIGURE13
TO CONVERTAPPLIANCE FOR USEWITH
NATURALGAS
WARNING
Electrical power and gas must be turnedoff prior to
conversion.
If this appliancehas been convertedfor usewith LPgas, eachof the
following modificationsmust be performedto convertthe unit back to
naturalgas.
A. Replaceallorificespuds
PerformSteps 1through4 onpage5.
ForStep5:Locatethecoloredbrassnaturalgasorificespudsthatwere
originallyinstalledinthisappliancebeforeitsconversionforusewithLP
gas.Observethecolorofeachofthespudsandnotethecorrectburner
locationfor eachspudasshowninfigures14and15.
CompleteSteps6through9 on page5 to completethe installationof
naturalgasmainspudsintheircorrectlocations.
Savethe orificesremovedfromthe applianceforfutureuse.Theywill
beneededifthisapplianceisagainconvertedforusewith LPgas.
B. Invertcapin appliancepressureregulator.
(Seefigures10and 11.)
With theapplianceinstalledtheapplianceregulatorshouldbelocated
as shownin eitherfigure 3 or figure4 (page3). Identifythe type of
applianceregulatorand follow the instructionsin the appropriate
illustration.
C. Adjustlowflameas instructedon page6 itemC.
AfterStepsA,BandChavebeencompleted,checktheappearanceof
eachburner'sflameat theHi andLosettingsagainstfigure13.tf the
flames appear too large or too small, make sure all steps were
completedcorrectly.
INSTALLATIONOF NATURALGAS
ORIFICESPUDS
4 BURNER MODEL (30"
OO
QO
FIGURE14
5 BURNER MODEL(36" WIDE)
OO
O O
)
FIGURE15
BURNERIGNITIONAND AUTO-REIGNITION
This applianceis equippedfor electronicauto-reignitionby meansof a
sparkigniterlocatedatthe rearofeachburner.Theburnersaredesigned
tolightatanyvalverotationthatadmitssufficientgasflowtosupportaflame
andto automaticallyretightfollowinga lossofflamedueto adraftorother
adversecondition.This featureisprovidedas a convenienceandis not
intendedasa safetyfeature.
CAUTION:Neverusea metalbladeto pryoff a controlknob.tf a knob
cannotbe easilyremovedtuckthe folds of a clothdishtowelunderand
aroundtheknobandpullthetowelupwardwith steadyevenpressure.
CAUTION:Nevercovercontrolknobsorsurroundingcontrolsurfacewith
utensils,towels,orotherobjects.Neverobstructfreeairpassagepastthe
controlknobs.Theknobopeningshavebeensizedto properlycontrolair
entrytotheinterioroftheapplianceduringoperation.
This appliance has no air shutters. Primary air adjustments are
unnecessary.Theburnersaredesignedtoprovideoptimumaerationforall
gases without air shutters.When operatingproperly,burners should
produceclearlydefined,evenblueflames.Iftheflameshaveyellowtipsor
arehazyandotherwiseappearto haveinsufficientair,obtaintheservices
ofa qualifiedservicetechnician.
Specifiedinputratesareasshowninfigures16and 17,below.
4 BURNER MODEL
FIGURE16
BURNER
LOCATION
RightFront
RightRear
LeftFront
LeftRear
5 BURNER MODEL
INPUTRATES- NATURALGAS(BTU/HR)
Hi Lo
12,000 1,500
9,100 1,050
6,500 830
10,500 1,500
TOP GRATEREPLACEMENT
Thetopgratesonthiscooktophaveundersideprojectionlugsdesignedto
nestin matchingdepressionsinthespillovertrays.Duringgrateplacement
alwayspositiongratestomakethisengagement.Correctindexingofgrates
aboveburnerportswill preservethe grates'appearanceandhelpassure
longlife.
DETENT
WITH
INDENTATION
REQUIREDADJUSTMENTSAT TIME
OF INSTALLATION
Theinstallationofthis appliancemustconformwith localcodes,or inthe
absenceof localcodes,with the latesteditionof the NationalFuelGas
Code ANSI Z223.1 USA or current CAN!CGA-B149INSTALLATION
CODE.
D ThisappliancewasmanufacturedforusewithNaturalGas.If LPgas
isthefuelofchoice,followtheconversiontoLPprocedurefoundinthe
installationinstructions.
D Testall externalconnectionsfor gasleaks.Nevertest forgasleaks
withan openflame.
D Testall electricalconnections.
FIGURE17
BURNER
LOCATION
RightFront
RightRear
Center
LeftFront
LeftRear
INPUTRATES- NATURALGAS(BTU/HR)
Hi Lo
12,000 1,500
9,100 1,050
6,500 830
9,100 1,050
10,500 1,500
10
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Jenn-Air CCG2523B Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI