American Standard 7455107.295 Installation guide

Category
Sanitary ware
Type
Installation guide
- 1 -
Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2018
Thank you for selecting American Standard...
the benchmark of fine quality for over 140 years.
To ensure that your installation proceeds smoothly-please read
these instructions carefully before you begin.
RECOMMENDED TOOLS
1
INSTALL FAUCET
TOWN SQUARE
®
S
MONOBLOCK LAVATORY FAUCET
WITH PUSH DRAIN
INSTALLATION
INSTRUCTIONS
74551XX
Screwdriver Adjustable WrenchChannel Locks
Certied to comply with ANSI A112.18.1M
CAUTION
Turn off hot and cold water
supplies before begining.
COLLAR ON
MOUNTING NUT
2
4
3
1
GROOVE
(FAUCET
BASE)
MOUNTING SURFACE
6
4
7
5
Fig. C.
Fig. B.
Fig. A.
8
PUTTY
IF REQUIRED
M965899 (4/18)
Installation with ESCUTCHEON PLATE: Apply a light bead of
plumbers putty to underside of ESCUTCHEON PLATE (8)
if mounting surface is uneven. Place ESCUTCHEON PLATE (8)
onto sink or mounting surface. Feed FAUCET SUPPLIES (3),
MOUNTING STUD (4) through ESCUTCHEON PLATE and
PUTTY PLATE and mounting hole of lavatory or mounting
surface. Fig. A.
Installation less ESCUTCHEON PLATE: Seat SEAL (1)
into under side of FAUCET BASE (2).
Feed FAUCET SUPPLIES (3), MOUNTING STUD (4)
through the mounting hole of lavatory or
mounting surface. Fig. B.
From below, push GASKET (7) and RETAINING WASHER (5) onto
MOUNTING STUD (4). Secure Faucet with MOUNTING NUT (6),
pulling faucet to front of sink, so SUPPLIES (3) rests against
mounting hole. Before nal tightening, make sure collar on
MOUNTING NUT (6) is seated into RETAINING WASHER (5). Fig. C .
Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6)
to complete faucet mounting.
- 2 -
M965899 (4/18)
4 5
6
FLANGE GASKET AND POP-UP KNOB CHECK OPERATION OF POP-UP
Check DRAIN FLANGE in SINK to ensure that
FOAM GASKET (3) is fully compressed and not visible.
FOAM
GASKET
NOT VISIBLE
DRAIN
FLANGE
2 3
INSTALL DRAIN FROM BELOW FIXTURE
• Install DRAIN (1) by dropping it from the top of the sink.
From under side of SINK install GASKET (2) and
MOUNTING NUT (3).
Note: Plumber’s putty or caulk is recommended.
Thread TAIL PIECE NUT (1) clockwise onto
DRAIN BODY (2).
DRAIN
OUTLET
REAR OF SINK
1
2
3
1
2
1
Operate DRAIN STOPPER (1) to verify that it opens
and closes.
MAKE WATER SUPPLY AND WASTE CONNECTIONS
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on tting supplies are 3/8" compression. Connect
left SUPPLY (1) to Hot (Marked with a Red Band) and right
supplyto COLD (2) wall supply.
• Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer
must purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop
as illustrated to avoid kinking.
Connect 1-1/4" O.D. tailpiece on POP-UP DRAIN to
waste outlet.
1
APPROX. 20"
2
COLD
HOT
3/8" COMPRESSION
RED
BAND
BLUE
BAND
- 3 -
8
9
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
• Remove AERATOR (3).
• Operate HANDLE (1) to ush water lines thoroughly.
• Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
Fill lavatory with water. Check that DRAIN STOPPER (4)
makes a good seal and retains water in SINK.
Release DRAIN STOPPER (4) down and check all drain
connections and “P” trap for leaks. Tighten if necessary.
To remove or replace cartridge:
— Turn valve to OFF position.
— Pull out INDEX (1).
— Loosen SET SCREW (2). Pull off HANDLE (3).
— Pull off CAP (4).
— Pull out CARTRIDGE (5).
Inspect CARTRIDGE (5) for debris and clean if necessary.
— Clean MANIFOLD (6) and rinse clean.
— Reinstall CARTRIDGE (5) onto MANIFOLD (6).
Reinstall CAP (4) and HANDLE ASSEMBLY (3).
If spout drips, operate handle several times from OFF to ON
and HOT to COLD position. Do not force
CARE INSTRUCTIONS:
TEST INSTALLED FITTING
7
M965899 (4/18)
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
Operate DRAIN STOPPER (1) to verify that it opens
and closes.
SERVICE
CAUTION
Turn off hot and cold water
supplies before begining.
2
4
2
“P” TRAP
WASTE
OUTLET
1
OFF
ON
COLD
HOT
3
4
5
1
6
3
2
2.5mm
HEX KEY
- 4 -
M970455-YYY0A
HANDLE KIT
M970518-YYY0A
HANDLE KIT WITH
RED/BLUE INDEX
7455.114/117
M962682-0070A
CARTRIDGE
M923840-0070A
AERATOR (1.2 GPM)
M907063-YYY0A
CAP
M904528-0070A
CARTRIDGE NUT
M964369-YYY0A
PLUG BUTTON &
SET SCREW
M911793-0070A
SEAL SPOUT
M962090-0070A
MOUNTING KIT
M970458-YYY0A
SPOUT
ESCUTCHEON
M953456-YYY0A
DRAIN ASSEMBLY
2555101P.YYY
ESCUTCHEON
& PUTTY PLATE
M918053-0070A
HANDLE ADAPTER
A918657-0070A
HANDLE SCREW
- 4 -
M965899 (4/18)
TOWN SQUARE
®
S
MONOBLOCK LAVATORY
FAUCET WITH
PUSH DRAIN
MODEL NUMBER
74551XX
Replace the “YYY” with
appropriate finish code
POLISHED CHROME 002
BRUSHED NICKEL 295
LEGACY BRONZE 278
POLISH NICKEL 013
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST
Saturday 10:00 a.m. to 4:00 p.m. EST
IN CANADA 1-800-387-0369
(TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

American Standard 7455107.295 Installation guide

Category
Sanitary ware
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI