American Standard 7353101.278, 7353101.002, 7353101.013, 7353101.295 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the American Standard 7353101.278 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
- 1 -
Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2016
Thank you for selecting American Standard...
the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly-please read
these instructions carefully before you begin.
RECOMMENDED TOOLS
1
M965722 Rev. 1.0 (7/16)
INSTALL FAUCET
TOWNSEND
®
MONOBLOCK LAVATORY FAUCET
WITH SPEED CONNECT
®
DRAIN
INSTALLATION
INSTRUCTIONS
7353.101
Screwdriver Adjustable Wrench Tubing CutterChannel Locks
Certied to comply with ANSI A112.18.1M
1
2
5
4
GROOVE
(FAUCET
BASE)
MOUNTING
SURFACE
3
8
Figure A
CAUTION
Turn off hot and cold water
supplies before begining.
Seat SEAL (1) into under side of ESCUTCHEON RING (2).
Seat ESCUTCHEON RING (2) with collar facing up into groove in faucet
base.
Feed FAUCET SUPPLIES (3), MOUNTING STUD (4) and DRAIN CABLE
ASSEMBLY (8) through ESCUTCHEON RING (2) and the mounting hole
of lavatory or mounting surface. Figure A.
From below, push GASKET (7) and RETAINING WASHER (5) onto
MOUNTING STUD (4). Secure Faucet with MOUNTING NUT (6), pulling
faucet to front of sink, so SUPPLIES (3) rests against mounting hole.
Before nal tightening, make sure collar on MOUNTING NUT (6) is
seated into RETAINING WASHER (5).
Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6) to
complete faucet mounting.
6
4
COLLAR ON
MOUNTING NUT
7
5
Figure B
- 2 -
2
M965722 Rev. 1.0 (7/16)
3
REMOVE FLANGE
• Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3).
Tighten TAILPIECE (4) on DRAIN BODY before
installing DRAIN BODY. Fig. B.
POP-UP DRAIN
Thread FLANGE (1) counter-clockwise and
remove FLANGE (1) and FOAM GASKET (2)
from drain body. Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of
drain body. Push GASKET (4) down against
LOCKNUT (3). Fig. B.
4
INSTALL DRAIN FROM
BELOW FIXTURE
From under side of SINK
install DRAIN BODY (1) up
through drain outlet.
Note: No plumber’s putty
or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards
the rear of the SINK.
Install FOAM GASKET (3) and
FLANGE (4) onto drain body
from above SINK and tighten
FLANGE (4) rmly.
2
3
1
Fig. A. Fig. B.
DRAIN
BODY
4
2
3
4
Fig. B.
1
Fig. A.
6
FLANGE GASKET AND POP-UP KNOB
Check DRAIN FLANGE in SINK to ensure that
WHITE FOAM GASKET (3) is fully compressed
and not visible. Fig. A.
POP-UP KNOB (1) must be fully down. Fig. B.
2
DRAIN
OUTLET
1
3
4
REAR OF SINK
5
TIGHTEN LOCKNUT
Tighten LOCKNUT (1) rmly with Adjustable
Wrench or Channel Locks.
1
WHITE FOAM
GASKET
NOT VISIBLE
DRAIN
FLANGE
Fig. A. Fig. B.
DOWN
1
- 3 -
8
9
Thread CABLE CONNECTOR (1) clockwise
onto DRAIN BODY CONNECTION (2) and
hand tighten. Fig. A.
Your new POP-UP DRAIN installation is
now complete. Fig. B.
Note: Tailpipe on pop-up drain is 1-1/4"
O.D. Fig. B.
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and
closes.
Note: If STOPPER (2) does not open and close properly then
refer to the “troubleshooting section” of these instructions.
CHECK OPERATION OF POP-UP
MAKE WATER SUPPLY AND WASTE CONNECTIONS
ATTACH CABLE CONNECTOR
7
M965722 Rev. 1.0 (7/16)
Fig. A.
2
1
Fig. B.
1-1/4" O.D.
2
1
1
APPROX. 20"
2
COLD
HOT
3/8" COMPRESSION
RED
BAND
BLUE
BAND
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on tting supplies are 3/8" compression.
Connect left SUPPLY (1) to Hot (Marked with a Red Band)
and right supply to COLD (2) wall supply.
Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer must
purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinking.
Connect 1-1/4" O.D. tail piece on POP-UP DRAIN to
waste outlet.
M965722 Rev. 1.0 (7/16)
11
12
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to ush water lines thoroughly.
Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and ll lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in Sink. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and “P” trap for leaks. Tighten
if necessary.
To remove or replace cartridge:
– Turn valve to OFF position.
– Pull out PLUG BUTTON (1) and remove HANDLE SCREW (2).
– Pull off HANDLE (3) and CAP (4).
– Unthread CARTRIDGE NUT (5) and remove.
– Pull out CARTRIDGE (6).
– Inspect CARTRIDGE (6) and O-RINGS (7) for debris and
clean if necessary.
– Clean MANIFOLD (8) and rinse clean.
– Reinstall CARTRIDGE (6) and O-RINGS (7) onto
MANIFOLD (8).
– Reinstall CARTRIDGE NUT (5), CAP (4) and HANDLE
ASSEMBLY (3).
If spout drips, operate handle several times from OFF to ON
and HOT to COLD position. Do not force - handle turns only 90˚.
ADJUST HOT LIMIT SAFETY STOP
By restricting HANDLE rotation and limiting the amount of
hot water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP (9) reduces risk of accidental scalding. To lower the
maximum hot water temperature of your faucet, all you need to
do is adjust the setting on the HOT LIMIT SAFETY STOP (9).
Note: The HOT LIMIT SAFETY STOP (9) is set at the neutral
setting from the factory. Fig. A.
To adjust HOT LIMIT SAFETY STOP:
– Remove HANDLE ASSEMBLY (3), CAP (4) and
CARTRIDGE NUT (5).
– Set the CARTRIDGE STEM (10) to the OFF position.
– Lift up the HOT LIMIT SAFETY STOP (9).
– Place the HOT LIMIT SAFETY STOP (9) in the desired GRAY
SHADED AREA (11) to limit the hot water. Fig. B.
Reinstall CARTRIDGE NUT (5), CAP (4) and HANDLE ASSEMBLY (3).
SERVICE
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
TEST INSTALLED FITTING
10
1
4
3
OFF
ON
HOT
COLD
5
“P” TRAP
WASTE
OUTLET
2
2
CAUTION
Turn off hot and cold water
supplies before beginning.
8
4
5
6
REMOVE
INSTALL
7
10
9
1
2
2.5mm HEX KEY
3
+HOTTER
COLDER
9
10
A
B
11
SETTING
MARKS
M965722 Rev. 1.0 (7/16)
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
• Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
Speed Connect
®
Drain
Troubleshooting Guide
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
CABLE ADJUSTMENT PROCEDURE
CAM
CAM CAP
Fig. B.Fig. A.
2
1
RE-ATTACH
DISCONNECT
Fig. C.
STOPPER
DOWN
1
REMOVE
CAM
Fig. E.
Fig. F.
Fig. D.
REMOVE
CAM CAP
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use ngers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
STOPPER REMOVAL PROCEDURE
- 6 -
M965722 Rev. 1.0 (7/16)
Unlocked Mode
Locked Mode
(Vandal Proof)
LOGO
DRAIN
Fig. G.
LOOP TOWARD
REAR OF SINK
LOOP TOWARD
FRONT OF SINK
180˚
LOGO
DRAIN
Fig. H.
Fig. J. Fig. K.
INSTALL
CAM CAP
CAM
INSTALL CAM
STOPPER INSTALLATION PROCEDURE
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
Removed) or “Unlock” Mode (Stopper is removable).
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice that the
Loop is on one side of the Stopper. Fig. G.
To install the stopper in “Locked” mode, insert the Stopper into the Drain so
that the Plastic Loop is facing toward the rear of the Sink and the American
Standard logo is facing front. Rotate Stopper slightly if necessary so that the
Stopper slides all the way down. Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary to make sure
it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing outward. If
the Cam Cap does not “snap” into place, then rotate the Cam to make sure
it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in Troubling
Shooting Guide to complete installation. Stopper will be in “Locked” mode
and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice that the
Loop is on one side of the Stopper. Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into the Drain
so that the Plastic Loop is facing toward the front of the Sink and the American
Standard logo is facing rear. Rotate Stopper slightly if necessary so that the
Stopper slides all the way down. Fig. H.
Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it
is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing outward. If the
Cam Cap does not “snap” into place, then rotate the Cam to make sure it is
fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troubleshooting Guide” to complete installation. Stopper will be in
“Unlocked” mode and removable.
M970054-0070A
CARTRIDGE
M962492-0070A
MOUNTING KIT
M918462-0070A
CABLE ADAPTER
M970045-YYY0A
POP-UP ROD
M970053-0070A
CARTRIDGE NUT
7353101P-YYY
ESCUTCHEON KIT
(OPTIONAL)
M907326-YYY0A
CARTRIDGE CAP
M970044-YYY0A
HANDLE KIT
M970168-0070A
AERATOR
(1.2 GPM)
M919660-0020A
6” TAILPIECE
(NOT INCLUDED
WITH FAUCET)
M952425-YYY0A
DRAIN ASSEMBLY
M952430-0070A
CABLE ASSEMBLY
- 7 -
M965722 Rev. 1.0 (7/16)
TOWNSEND
®
MONOBLOCK LAVATORY
FAUCET WITH
SPEED CONNECT
®
DRAIN
MODEL NUMBER
7353.101
Replace the “YYY” with
appropriate finish code
POLISHED CHROME 002
SATIN NICKEL 295
LEGACY BRONZE 278
POLISH NICKEL 013
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST
Saturday 10:00 a.m. to 4:00 p.m. EST
IN CANADA 1-800-387-0369
(TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
/