Energizer V23-00208 User manual

Type
User manual

Energizer V23-00208 is a 3-Phase Kit used to measure electrical energy data across multiple phases of both consumption and generation and report it back to the Energizer Homepower system.

It can measure energy data from up to 3 phases of consumption and up to 3 phases of generation from Solar PV systems. It is accompanied by voltage references measured via digital meter(s).

The kit includes CT sensors that can be clipped on each phase between the loads and the grid, and between the PV inverter and the loads.

Energizer V23-00208 is a 3-Phase Kit used to measure electrical energy data across multiple phases of both consumption and generation and report it back to the Energizer Homepower system.

It can measure energy data from up to 3 phases of consumption and up to 3 phases of generation from Solar PV systems. It is accompanied by voltage references measured via digital meter(s).

The kit includes CT sensors that can be clipped on each phase between the loads and the grid, and between the PV inverter and the loads.

3-Phase Kit - (CT)
Installation Instructions
Energizer Homepower 3-Phase Kit - Installation Instructions V23-00208
© 2021 Energizer. Energizer and certain graphic designs are trademarks of Energizer Brands, LLC and related subsidiaries and are used under license by 8 Star Energy Pty Ltd. All
other brand names are trademarks of their respective owners. Neither 8 Star Energy Pty Ltd nor Energizer Brands, LLC is aliated with the respective owners of their trademarks.
2
Determine the system conguration from the list below,
and follow the corresponding line diagram on the
reverse side to complete wiring.
Power digital meter(s) and change settings accordingly.
The 3-Phase Kit is used to measure electrical energy data
across multiple phases of both consumption and generation
and report it back to the Energizer Homepower system.
STEP 1 - WIRINGCONTENTS
INTRODUCTION
There is provision within this kit to measure energy data
from up to 3 phases of consumption by clipping a CT sensor
on each phase between the loads and the grid, and up to 3
phases of generation from Solar PV systems by clipping a CT
sensor on each phase between the PV inverter and the loads.
This is accompanied by voltage references measured via the
digital meter(s).
If the Solar PV system is only Single Phase then a digital meter
is not required for capturing “Generation” as this data may be
captured by the CT (for PV) supplied with the Main Unit (HP-6M).
3
V23-00208
© 2021 Energizer. Energizer and certain graphic designs are trademarks of Energizer Brands, LLC and related subsidiaries and are used under license by 8 Star Energy Pty Ltd. All
other brand names are trademarks of their respective owners. Neither 8 Star Energy Pty Ltd nor Energizer Brands, LLC is aliated with the respective owners of their trademarks.
4
V23-00208
© 2021 Energizer. Energizer and certain graphic designs are trademarks of Energizer Brands, LLC and related subsidiaries and are used under license by 8 Star Energy Pty Ltd. All
other brand names are trademarks of their respective owners. Neither 8 Star Energy Pty Ltd nor Energizer Brands, LLC is aliated with the respective owners of their trademarks.
Grid
Meter
Grid
Meter
Solar
Meter
Solar
Meter
Energizer Homepower 3-Phase Kit - Installation Instructions V23-00208
© 2021 Energizer. Energizer and certain graphic designs are trademarks of Energizer Brands, LLC and related subsidiaries and are used under license by 8 Star Energy Pty Ltd. All
other brand names are trademarks of their respective owners. Neither 8 Star Energy Pty Ltd nor Energizer Brands, LLC is aliated with the respective owners of their trademarks.
5
STEP 2 - CODE & CT
1. Press
2. Press
3. Press
4. Press
5. Press
6. Press
1. Press
2. Toggle between
3. Press
to edit “CT” value.
to exit.
to set value to “20”.
to enter the “code” screen.
to edit code from “600” to “701” to enter menu.
to change the last digit from “0” to “1”.
twice to move to the rst digit.
to change the rst digit from “6” to “7”.
twice to get to settings, you will see “ ”.
Note: “20” is the ratio for the CT’s provided in this kit.
If you are using 3rd party CT’s you may need to adjust this value.
Note: The numbers will reset to “600”.
Energizer Homepower 3-Phase Kit - Installation Instructions V23-00208
© 2021 Energizer. Energizer and certain graphic designs are trademarks of Energizer Brands, LLC and related subsidiaries and are used under license by 8 Star Energy Pty Ltd. All
other brand names are trademarks of their respective owners. Neither 8 Star Energy Pty Ltd nor Energizer Brands, LLC is aliated with the respective owners of their trademarks.
6
STEP 3 - PROTOCOL & ADDRESS
1. Press
2. Press
3. Press
4. Press
1. Press
2. Press
to get to “Addr” screen.
to edit value.
to keep value.
to exit.
to edit value.
set Consumption meter to “1” / Generation meter to “2”.
twice to get to “Prot” screen.
to edit value.
to scroll through to nd “n.1”.
to exit.
3. Toggle between
4. Press
5. Press
Energizer Homepower 3-Phase Kit - Installation Instructions V23-00208
© 2021 Energizer. Energizer and certain graphic designs are trademarks of Energizer Brands, LLC and related subsidiaries and are used under license by 8 Star Energy Pty Ltd. All
other brand names are trademarks of their respective owners. Neither 8 Star Energy Pty Ltd nor Energizer Brands, LLC is aliated with the respective owners of their trademarks.
7
Metering
STEP 5 - INSTALLER APPSTEP 4 - BAUD RATE
Start by selecting
Dual or Three Phase metering
1. Press
2. Press
3. Press
4. Press
to get to “bAud” screen.
to set value.
to scroll to “2.400”.
to exit.
Energizer Homepower 3-Phase Kit - Installation Instructions V23-00208
© 2021 Energizer. Energizer and certain graphic designs are trademarks of Energizer Brands, LLC and related subsidiaries and are used under license by 8 Star Energy Pty Ltd. All
other brand names are trademarks of their respective owners. Neither 8 Star Energy Pty Ltd nor Energizer Brands, LLC is aliated with the respective owners of their trademarks.
8
Select whether you are using:
1 x Digital Meter + 1x CT
or
2 x Digital Meters
Input Ratio: Set Value to “20 Review & Test
Note: “20” is the ratio for the CT’s
provided in this kit. If you are using
3rd party CT’s you may need to
adjust this value.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Energizer V23-00208 User manual

Type
User manual

Energizer V23-00208 is a 3-Phase Kit used to measure electrical energy data across multiple phases of both consumption and generation and report it back to the Energizer Homepower system.

It can measure energy data from up to 3 phases of consumption and up to 3 phases of generation from Solar PV systems. It is accompanied by voltage references measured via digital meter(s).

The kit includes CT sensors that can be clipped on each phase between the loads and the grid, and between the PV inverter and the loads.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI