Koper Fox IT 10 User And Service Manual

Category
Stoves
Type
User And Service Manual

This manual is also suitable for

INSTRUCTIONSFORCONNECTING,OPERATION,ANDMAINTENANCEOFTHESTOVE
Hydro+AirPelletstovesBearIT
USER AND SERVICE MANUAL
BEARITPage1
BEARITPage2
TABLEOFCONTENTS
1.0INTRODUCTION………………………………………………………………………………………………………………. 3
2.0UPDATINGTHEINSTRUCTIONS……………………………………………………………………………………….. 3
3.0PRECAUSTIONSANDSAFETY……………………………………………………………………………………………3
4.0.RESPONSIBILITIESOFTHEMANUFACTURER……………………………………………………………….. 4
4.1.RESPONSIBILITIESOFTHEINSTALLER…………………………………………………………………………….. 4
5.0TECHNICALCHARACTERISTICS………………………………………………………………………………………… 5
5.1ACCESSORIES………………………………………………………………………………………………………………….. 5
5.2ASSEMBLINGTHECONTROLPANEL………………………………………………………………………………… 5
5.3TECHNICALDESCRIPTION……………………………………………………………………………………………….. 5
5.4TECHNICALDATAANDDIMENSIONS………………………………………………………………………………. 6
6.0INSTALLATIONSITEPREPARATION………………………………………………………………………………….. 7
6.1GENERALRULES……………………………………………………………………………………………………………… 7
6.2CONNECTIONOFTHEOUTERAIRPIPE……………………………………………………………………………. 8
6.3EXHAUSTGASSYSTEM……………………………………………………………………………………………………. 8
6.4EXHAUSTGASESANDINSTALLATION……………………………………………………………………………… 8
6.5USABLEPIPES…………………………………………………………………………………………………………………. 8
6.6INSTALLATIONSCHEMES………………………………………………………………………………………………… 9
6.7REARENDOFTHEEXHAUSTGASPIPE…………………………………………………………………………….. 9
6.8CONNECTIONTOTHEELECTRICALPOWERSUPPLY…………………………………………………………. 10
7.0USAGE…............................................................................................................................... 10
7.1IMPORTANTINSTRUCTIONS……………………………………………………………………………………………. 10
7.2SAFETYPRECAUTIONS…………………………………………………………………………………………………….. 11
7.3WARNINGSAFETYMEASURESFORSTAFF………………………………………………………………………. 11
7.4WARNINGSAFETYMEASURESFORTHEUSER…………………………………………………………………. 11
7.5SAFETYGUIDILINESFORIGNITIONANDCLEANINGOFTHESTOVE…………………………………. 12
8.0FUELS……………………………………………………………………………………………………………………………… 13
9.0TECHNICALSPECIFICATIONS…………………………………………………………………………….……………… 13
10.0ELECTRONICCOMPONENTSSCHEME………………………………………………………….……………… 14
11.0EXPLANATIONOFTHEELECTRONICCONTROLPANEL………............................................... 15
12.0HYDRAULICINSTALLATION…………………………………………………………….……………………………… 25
13.0PELLETS…………………………………………………………………………………………………………………………. 29
13.1STORAGEOFPELLETS.…………………………………………………………………………………………………… 29
13.2POURINGTHEPELLETS………………………………………………………………………………………………….. 29
14.0CLEANINGANDMAINTENANCE…………………………………………………………………………………….. 30
14.1CLEANINGANDMAINTENANCEOFTHEEXHAUSTPIPE…………………………………………………. 30
14.2CLEANINGANDMAINTENANCEOFTHESTOVE…………………………………………………………….. 30
14.3PERIODICALCLEANING…………………………………………………………………………………………………. 30
14.4GENERALCLEANING……………………………………………………………………………………………………… 31
15.0POSTSALESUPPORT………………………………………………………………………………………………………32
16.0FAILURES‐CAUSES–SOLUTIONS…………………………………………………………………………………. 33
17.0WARRANTYTERMSANDCONDITIONS………………………………………………………………………….. 36
BEARITPage3
1.0.INTRODUCTION
Dearbuyer,wethankyouforchoosingthisproduct.
 ThisproductismadeinaccordancewiththesafetyrequirementsspecifiedbytherelevantEuropean
directives.Thismanualisintendedtoowners,installers,usersandmaintenancepersonnelofthisproduct
andisanintegralpartoftheproduct.Ifthereareanydoubtsregardingthecontentsofthismanualorofany
explanationpleasecontactmanufactureroranauthorisedservicecentre.Noprintingtranslationor
reproducingofthismanualisallowedwithoutthepermissionofKOPER.Thetechnicalinformation,
illustrationandspecificationincludedinthismanualmaynotbedisclosed.
 Donotoperatetheapplianceifanyoftheinstructionprovidedinthemanualarenotunderstood.
KOPERreservestherighttomodifythetechnicaland/orfunctionalspecificationofthestoveatanytime
withoutpriornote.Byusingthisinstructionmanualyouwilllearnhowtouseyourpelletburningstove
roperly;pleasereaditcarefullybeforeuse.p
Thisproductismanufacturedinaccordancetothefollowingdirectivesandstandards:
Directive89/106/EEC–Approximationofthelaws,regulationandadministrativeprovisionsofthemember
statesrelatingtoconstructionproducts.
Directive2004/108/EC–Approximationofthelawsofthememberstatesrelatedtoelectromagnetic
compatibility.
Directive2006/95/EC–Electricalequipmentdesignedforusewithincertainvoltagelimits.Directive
89/391/EEC–Introductionofmeasurestoencourageimprovementsinthesafetyandhealthoftheworkers
atwork.
Directive85/374/EEC–Approximationofthelaws,regulationsandadministrativeprovisionsofthemembers
statesconcerningliabilityfordefectiveproducts.
Directive1999/374/EC–Radioequipmentandtelecommunicationterminalequipmentandthemutual
recognitionoftheirconformity.
StandardEN14785/2006Residentialspaceheatingappliancesfiredbywoodpellets–Requirementsandtest
methods.
2.0.UPDATINGTHEINSTRUCTIONS
Thismanualreflectsaworkofartatthemomentwhenthestovewasplacedonthemarket.Therefore,we
doesnottakeintoaccountthestovesthatarealreadyonthemarketwiththeappropriatetechnical
documentationandconsidersthemasdefectiveorinadequateafteranykindofmodification,adaptationor
applicationofnewtechnologiestonewlyproducedmachines.
Thecontentsofthismanualshouldbecarefullyreadandstudied.Itisnecessarytostrictlyfollowallthe
instructionsgiveninthismanual.Allinformationcontainedinthismanualisnecessaryforproperconnection,
use,andmaintenanceofyourstove.
Therefore,thismanualhastobecarefullystoredforthenecessaryinstructionsintheeventofanyproblems
orconcerns.
Ifthestoveisgivenorsoldtoanotherperson,thenewownermustalsobegiventhisinstructionsmanual.
Ifyouhavelostyourmanual,wecanprovideyouwithanewone.
3.0.PRECAUTIONSANDSAFETY
Thecombined(hydro+air)pelletstovesaredesignedtoprovidemaximumsafetyandeasyofoperation.
Howeveritisnecessarytoobservethefollowingsafetyguidelinestoensureanaccident‐freeoperation.
1. Itisrecommendedthattheauthorizedmaintenancestaffshouldmakesurenottoleavebarepartsof
thewiresnotcompletelyinsertedintotheconnectors,sothatnolivepartsofthewiresmaycontactother
bjects.o
2. Theinstallationshouldbeperformedbyspeciallytrainedstaffauthorizedbythemanufacturer;afterits
completion,thestaffisobligedtogivetotheenduserastatementwhichstatesthatthepelletstoves
connectedaccordingtoallapplicablestandardsandthatthestafftakesoverthecompleteresponsibilityfor
itsinstallation.
3. Itisimportanttoobserveallapplicablenationallawsofthecountrywheretheproductistobeinstalled.
4. Themanufacturerdoesnotbearanyresponsibilityiftheabovestatedobligationsarenotobserved.
5. TheInstructionmanualisoneinseparablepartoftheproduct.IncasetheInstructionmanualismissing
BEARITPage4
o
rlost,theenduserscouldhaveitprovidedbytheseller.
6. Thispelletstoveshouldbeusedonlyforthepurposeitisintendedfor.
7. Themanufacturerdoesnothaveanyresponsibilityfordamagesmadebypeople,animalsorobjects
ausedduetoinstallationerrorsorimproperuse.c
8. Afterremovingthepackaging,theusershouldcheckwhetherallthepartsareinplaceandifanyparts
missing,theusershouldhavethesellerprovidethemissingparts.
9. Onlyoriginalpartsmustbeusedforreplacementoffaultyones.Pleasereferonlytoauthorizedservice
gentsholdingcertificateformaintenanceofequipment.a
10. Forproperoperationoftheproduct,itshouldbeservicedonceafterconsumptionof1800kgcertified
pelletsoronceayear.Theserviceshouldbeperformedbyauthorizedstaff.
Forsafetypurposes,thefollowingmustbestrictlyobserved:
Thepelletstoveisnottobeoperatedbychildrenordisabledpersons.
Itisforbiddentoinstalltheproductinatoilet,dampspaces,suchaslaundryroom,aswellasto
touchthepelletstovewithwethandsorlegs.Powersupplysocketwithagroundterminal(safetysocket)
shouldprovidetopowertheappliance.
Itisforbiddentochangeorcancelthesafetyprecautionswitchoutanauthorizationbyaauthorized
technician.
Donotpull,tear,burnthecablescomingoutfromtheproductevenifitisoff.
Donotleavethepackagingclosetochildrenordisabledpersons.
Duringthenormaloperationoftheproduct,thedoorshouldbeclosedatalltimes.
Avoiddirectcontactwithhotpartsoftheproduct.
Checkiftherearedifficultieswhileturningtheproductonafteralongperiodofnon‐operation(see
chapter6.0).
Thepelletstoveisdesignedtoworkeveninextremeweatherconditions,however,incaseofstrong
windorfrostyconditions,thesafetysystemsmighttriggeronandshutthepelletstoveoff.Insuchcase,the
usershouldcontacttheauthorizedservice.Itisnotadvisabletodisableorresetthesafetydevicesonthe
user’sdiscretion.
Fireextinguishershouldbeinreachincaseofaccidentaloccurrenceoffireintheexhaustgaspipe.
4.0.RESPONSIBILITIESOFTHEMANUFACTURER
Inissuingtheseinstructions,weacceptnocivilorlegalliability,directorindirect,dueto:
Accidentscausedbynotrespectingthestandardsandspecificationsgiveninthismanual,
Accidentscausedbyimproperhandlingoruseofthestovebytheuser,
Accidentsresultingfrommodificationsandrepairs,whichwerenotapprovedbyus,
Poormaintenance,
Unforeseenevents,
Accidentsresultingfromtheuseofsparepartsthatwerenotoriginalornotintendedforthesemodelsof
stoves.
Responsibilityforconnectingisfullyassumedbytheinstaller‐contractor.
4.1.RESPONSIBILITIESOFTHEINSTALLER
Installer'sresponsibilityistodoallthetestsofthefluepipeline,airsupply,andallthethingsthatare
necessaryforconnecting(installing)yourstove.
Installer'sresponsibilityistoadjustthestovetolocalregulationswhichapplywherethestoveisconnected
(installed).
Theuseofthestovemustbeinaccordancewiththeinstructionsforuseandmaintenance,aswellaswithall
thesecuritystandardsthataregivenbythelocalregulationsthatapplywherethestoveisconnected
(installed).
Theinstallerhastocheck:
‐ Thetypeofstovetobeconnected,
‐ Whethertheroomcorrespondstothestovewherethestovewillbeinstalled,whichisexpressedasthe
minimumsizerequiredforinstallation,setforthbythemanufacturerofthestove,
‐ Heatgenerator
‐ Manufacturer’sinstructionsregardingtherequirementsofsmokeremovalsystems(ductsandpipesfor
smokeexhaust),
‐ innercrosssectionofthechimney,thematerialoutofwhichthechimneyismade,uniformcross
section,
‐ Thattherearenodisturbancesandobstaclesinthechimney,
‐ Heightandverticalextensionofthechimney,
‐ Altitudeattheplaceofconnectingthestove,
‐ Theexistenceandsuitabilityoftheprotectivecoverforthechimneythatisresistanttothewind,
‐ Thepossibilityofsecuringtheexternalairsupplyandthesizeofthenecessaryopenings,
‐ Simultaneoususeofstovethatneedstobeconnectedwithotherequipmentthatalreadyexistsatthat
place.Iftheresultsofallchecksarepositive,thenwecanproceedwithconnectingthestove.Makesureyou
followtheinstructionsofthemanufacturerofthestove,aswellasthestandardsforfireprotectionandthe
safetystandardsprovided.
Whenyouarefinishedconnecting,thestovehastobeturnedonintrialmodeforatleast30minutestotest
ifthestoveisworkingproperly.
Whentheinstallationandimportantdetailsarecompleted,theinstallermustprovidetheclientthe
following:
‐ Instructionsforuseandmaintenanceissuedbythemanufacturerofthestove(ifsuchinstructionsare
notprovidedwiththestove),
‐ Thedocumentationnecessarytocomplywiththeexistingstandards.
5.0.TECHNICALCHARACTERISTICS
5.1Accessories
B
eforetheinitialinstallationofthepelletstove,youshouldcheckwhetherallaccessoriesareinplace:
Remotecontroller(ifitsprovided)
Controlpanel+screwsforitsmounting(inthereservoirforpellets)
Powercordwithcable
Documentation(warranty,instructionmanual,service)
Important:Readcarefullythewholedocumentationandkeepitattentively.
5.2Assemblingthecontrolpanel
Whenyoutakethepelletstoveoutfromitspackaging,inthe
reservoirforpelletsyouwillfindthecontrolpanel(2)wrapped
inafoilandM5screws(3)mountedonbacksideoftop,which
reusedforitsassembling
a
(1).TaketheM5screwsoutandattachthepaneltothecover.
Important:Whenconnectingthepanel,becarefulnottocut
thecable
5.3Technicaldescription
TheMODELSisdesignedforheatingresidenceorofficespacestobeconnectedonsystemforcentral
heating,atthesametimecontributingtothemorepleasantambience.
BEARITPage5
Theboilerofthepelletstoveismadeofspecialmetalsheet,aswellasasupportingstructurewhichiscoated
ithhightemperaturepaint.Theburnerandpellettransporteraremadefromcastiron.
w
Thecombustionchamberhasadoorwithceramicglasswhichisheatresistantatatemperatureofupto
700oC.Bythissolutionwewantedyoutoseethefireinsidethechamber,atthesametimeavoidingcontact
withthedangeroussparklesandappearanceofsmoke.Thedoorishermeticallyclosed.
A–CONTROLPANEL
B–PELLETTANKANDCOVER
C–COVERFORCLEANINGOFTURBOLATORS
D–EXCHANGEROFHOTAIRWITHFAN
E–DOOR
F–CERAMICGLASS
G–HANDLE
H–ASHCOMPARATMNET
J–BURNER
K–OPENINGCOVERFORGENERALCLEANING
5.4Technicaldataanddimensions
BEARITPage6
Modelofthepelletstove:
BearIT
10+5kW
BearIT
12+5kW
BearIT
15+5kW
BearIT
17+5kW
BearIT
20+5kW
BearIT
25+5kW
Height(C)mm105010501150 1150 1250 1250
Width(A)mm660660660 660 660 660
Depth(B)mm660660660 660 660 660
Weightkg195205211 216 230 235
Distanceforexhaustpipe(D,E) mm 295,110 295,110 295,110 295,110 295,110 295,110
Distanceforcoolwaterpipe
(G,H) mm 355,145 355,145 355,145 355,145 355,145 355,145
Distanceforhotwaterpipe(F,J) mm 890,60 890,60 990,60 990,60 1090,60 1090,60
Diameterofexhaustgaspipe(K)mm808080 80 80 80
Heatingvolume(*)min‐maxm290‐120102‐136 120‐160 132‐176 150‐200 180‐240
Nominalthermalpower(Ptn)kW151720 22 25 30
Waterheatingoutput kW 10 12 15 17 20 25
Heatoutputtospace kW 5 5 5 5 5 5
Reducedthermalpower(Ptr)kW666 6 6 6
Max.consumptionperhourkg/h2.12.63.1 3.4 4.2 5,2
Min.consumptionperhourkg/h1.21.21.2 1.2 1.2 1.2
Reservoircapacitykg202025 25 30 30
Autonomyatnominalpowerh9.57.78.1 7.4 5.7 8
Autonomyatreducedpowerh16.616.620.8 20.8 25 25
Energyefficiency%939393 93 93 93
Workingpressure bar 1.8 1.8 1.8 1.8 1.8 1.8
Maximumallowedpressure bar 3 3 3 3 3 3
NominalelectricalpowerW340340340 340 340 340
NominalvoltageV230230230 230 230 230
NominalfrequencyHz505050 50 50 50
Theabovetableismadeonthebasisoftestsconductedusingwoodenpelletswithcaloricpowerof18220
j/kg(equalto4350Kcal/kg) K
*)Thesevaluesdependontheplaceofinstallation. (
Theabovevaluesareindicative,notobligatory.Themanufacturerretainshisrighttochangethevaluesin
everymomentinordertoimprovetheperformanceoftheproduct.
6.0.INSTALLATIONSITEPREPARATION
.1.Generalrules
BEARITPage7
6
Knowingthattheproperassemblyisveryimportant,aswellastheproperconnectionoftheexhaustgas
systemandthatthepossibleerrorsmadeduringtheassemblyarenotcoveredbythewarrantyof
MANUFACTURER,ourcompanyadvicestheinstallationtobemadeafterthefollowingchecks:
Minimumvolumeofthespacewherethepelletstoveisinstalled(avoidspacessmallerthan40m3);
Providegoodairflow;
Observeallthenorms;
Properoperationoftheexhaustgassystem;
oushouldalsoobservethefollowinglegalnormative: Y
Bansoninstallation
Therighttooccupyaspace
Itisnotallowedaninstallationofthepelletstoveinbedrooms,toilets,andinspaceswherealreadyexists
anotherheatingbodywithoutsufficientairintake(pelletstove,pelletstoveetc.).Itisnotallowedthe
nstallationofthepelletstoveinspacescontainingexplosivematerials. i
Theinstallationofthepelletstoveshouldbemadeinaccordancetoallpracticalknowledge.Thespace
aroundthepelletstoveshouldbemadeofstone,cementorotherfireproofmaterial.Thepelletstove
generatesheataroundtheburner.Therefore,youshouldavoidcontactofflammablematerialswiththe
burner(alcohol,paper,plastics…)
BEARITPage8
Minimal distance from the flammable materials is 200 mm except dimension explained on picture:
A = 200 mm , B = 200 mm , C = 100 mm
Ifthefloorismadeofflammablematerial(parquet...)itshouldbeadequatelyisolated.
Themetalpipesintendedforthegasexhaustshouldbeatadistanceof1,5mfromflammable
materials.
Werecommendthatthepelletstoveshouldbeinstalledascloseraspossibletotheexhaustgassystem,
alwayshavingmaximum3+1Tcurvesandmaximum3mofhorizontalflowwithminimalelevationof3‐5%.
Assoonastheplaceofinstallationisdefined,removethecardboardandtheotherprotectivematerialand
checkwhetherthedoorisproperlyclosed.
6.2CONNECTIONOFTHEOUTERAIRPIPE
Forproperoperationandproperdistributionofthetemperature,thepelletstoveshouldhavesufficientair
intakeandtobeplacedonsuitableplace(aspecialholeforairintakecanbemade).
T
heholeforairintakeshouldbe80cm2minimumandthereshouldnotbeanyobstacles.
Theairmaybealsotakenfromanotherroomwhichisconstantlyventilatedandinwhichthereisnoother
pelletstoveorothersystemwhichneedsanairintake.Thatroomcannotbeabedroom,toilet,andanother
spacewherethereisadangeroffire,suchasagarage,basement,andwarehousecontainingflammable
aterials. m
Ifthereisapelletstoveinthesameroomusinggasfromanopensystemoranyothersourceofharmfulgas,
theairintakeshouldbedirectlyfromoutside.
ANEXAMPLEOFCONNECTIONDIRECTLYFROMOUTSIDE
Forthesakeofproperoperationofthepelletstoveadirectconnectionfromoutsideispossible,usingmetal
pipeprovidedwithsiliconsealer.Itisimportantthatthefrontopeningofthepipeisprotectedagainstwind,
waterorother,usingacurveof90oturneddownwards.
Manufacturerdoesnotbearanyresponsibilityiftheaboveindicatedinstructionsarenotobserved.
Forproperplacementoftheairintakeyoushouldobservethefollowingdistances:1,5munderneath,1,5m
horizontally,0,3mfromabovethedoors,windows2,0mfromtheexhaustgassystem.
6.3EXHAUSTGASSYSTEM
Itisalwaysimportanttoknowthatthechimneyisimportantasthepelletstove.
Theinstallationoftheexhaustsystemonchimneyshouldbeperformedbyauthorizedpersons.Theauthorized
personshouldbeguidedbythefollowingdatafornormalworkingofstoveonreduced,maximalandnominal
power,Thisdataisoptimalandusedinlaboratorywhenstovearetested.
DraftofthepelletstovePa12
Massofthecombustedair g/s5.3
6.4EXHAUSTGASESANDINSTALLATION
Theexhaustgassystemoperatesasaresultofdepressionwhichoccursinthecombustionarea.Itisvery
mportantfortheexhaustgassystem,abovemarkedasSIG,tobemadeofcertifiedmaterialsand: i
Tobehermeticallyclosed,meaningthesystemshouldbemadeofspecialpipeswithadequatesilicon
sealer.
Tobeabletooperateunderhighpressureandundertemperaturerangingfrom200‐250oC(pipeswith
hicknessnotlessthan1mmisrecommended).t
Ifthepelletstoveisconnectedtotheexistingsystem,thesystemshouldbecheckedbyanauthorized
person.Thesystemcannotbeinstalledindoors.Periodicalcleaningoftheexhaustgassystemis
recommended.
6.5USABLEPIPES
Thepipesusedfortheexhaustgasesshouldberesistant, smoothfrominside,madeofmetalandtohave
siliconsealer.Thediameterofthepipesupto3mlongshouldbe80mmor100mmforpipeslongerthan3
orover1200mheightabovesealevel. m
Thelengthiscalculatedalongthewholehorizontalandverticallength,countingeachcurveof90oas1mof
ength. l
A
TTENTION
Donotconnectthesystemtotheexistingsystemortotheaspirationsystem.
BEARITPage9
6.6INSTALLATIONSCHEMES(optional)
DANGER!
It is forbidden to install shut‐off valves forthe flow (draft)of air (flap valves that can prevent airflow or
disabledrafts).
ATTENTION!!!
If the ejection path of smoke creates such a bad draft, of a bad flow of air (many curves, improper
completion of the ejection of smoke,constriction,etc.)dischargeofsmokecanbebad,orinasituation
likethissmokedischargingisnotasgoodasitcouldbe.
The smoke ejection system from the stove operates under negativepressure in thestove chamber and
with mild pressure from the smoke drain pipe. It is veryimportant that the smoke extraction system is
hermeticallyclosed(sealed). Thisrequirestheuse of asmooth tube onthe inside. First of all you must
carefullystudythe planandstructureoftheroomwhenthesmokeextractionpipeis set up through the
wallsandroof,sothattheinstallationofpipesisperformedproperlyinaccordancewiththestandardsof
fireprotection.
You should first ensure that the room where the stove is located has enough air for combustion. It is
advisable to periodically perform check so as to ensure that the combustion air comes right uptothe
combustion chamber. The stove operates at 230 V~ 50 Hz. Make sure that the electrical cord is not
underneaththefurnace,tobeawayfromthestove,tobeawayfromhotspots,andnottotouchanysharp
edges that it could interdict. If the stove is electrically overloaded, this can lead to shortening of the
lifetimeoftheelectronicsofthestove.
Never turn off the power supplyby pulling the plugwhen thereis a burning flamein the stove.
This
couldjeopardizetheproperfunctioningofthestove.
6.7REARENDOFTHEEXHAUSTGASPIPE
Therearendoftheexhaustgaspipeisintendedforproperexhaustofthegasesintheatmosphere,its
protectionagainstrain,snoworanyotherobjectsinordertoguaranteeexcellentexhaustofthegasesin
indyconditions,aswell. w
T
herearendoftheexhaustgaspipeshouldmeetthefollowingrequirements:
theinnerpartshouldbethesameasthatofthepelletstove;
theouterpartshouldnotbelessthantwicethantheoneofthepelletstove;
themanufactureshouldprotectthesystemagainstrain,snowandwind;
easydisassemblingforcleaningpurposes;
Possibilityforattractivefinishwhichfitstothebuilding.
Thesystemshouldnothaveobstaclesatadistanceoflessthan10m,suchaswalls,trees.Insuchacasethe
systemshouldend1mabovetheobstacles,andincaseofothersystems,2mfromthem,andineverycase
thesystemshouldbeatleast1abovetheroof.
Dimension and position
Angle Deference Min H of chimney
β A (m) H (m)
< 1.85 0.5 m
15 o
> 1.85 1 m
< 1.50 0.5 m
30 o
> 1.50 1 m
< 1.30 0.5 m
45 o
> 1.30 1 m
< 1.20 0.5 m
60 o
> 1.20 1 m
YES
NO
O
PERATIONALPROBLEMSDUETODEFECTSOFTHESYSTEMCAPACITY
Besidesallinfluencingatmosphereagents,thewindisthemostimportantagentforthesystemoperation.
6.8CONNECTIONTOTHEELECTRICALPOWERSUPPLY
ThestovemusttobeinstalledbyqualifiedpersonnelincompliancewithEN10683.
Allrequiredcablesandconnectorsareputintothepelletstove.Theinstallationisquickandsimple.
Beforeeachassemblingofthesystem,anautomatictestofthesystemisperformedforitsproperoperation.
Dependofsomeconfigurationsomecablesandconnectorscanbechanged.Whenyouturnontheproduct
forthefirsttime,youshoulddothefollowing:Whenyouaresurethattheassemblyisproperlydone,itis
possibletostartinitialturningONthepelletstovethesettingmightbemadeeitherthroughthecontrol
panelorthesoftware.
FornormaloperationofthestoveALLPARAMETERSISSAVEONTHEMOTHERBOARD.
Theproductshouldbeconnectedtotheelectricalpowersupply.Ourpelletstovesaresuppliedwitha
mediumtemperaturepersistentcable.Incaseyouneedtoreplacethecable,callanauthorizedservice
gent.Beforeyouconnecttotheelectricalpowersupply,youshouldcheckthefollowing: a
whetherthecharacteristicsoftheelectricalpowersupplymeettherequirementsindicatedontheplate
whethertheconnectionisproperlygrounded
Thecableshouldnothavetemperaturehigherthan75oC.
Incaseofadirectconnectiontotheelectricalpowersupply,callanauthorizedperson,anelectrician.Ifyou
donotusethepelletstoveforalongertimeperiod,youshoulddisconnectitfromtheelectricalpower
supply.Theconnectionshouldbeeasilyaccessible.
7.0USAGE
7.1SAFETYPRECAUTIONS
BEARIT Page10
Takingintoconsiderationthatthepelletstovedevelopshightemperature,theyoungandadultpersons
shouldbecareful,andespeciallythechildren.Itisforbiddentopourwateroranyotherliquidwhichmight
causetemperatureshock.Donotplaceflammableobjectsnearthepelletstove.
BEARIT Page11
7.2IMPORTANTINSTRUCTIONS
THEFOLLOWINGINSTRUCTIONSAREREQUIREDFORTHESAFETYOFPEOPLE,ANIMALS,AND
PROPERTY.
Wewishtoinformtheinstallerofthestoveonsomeofthegeneralguidelineswhichmustbefollowedfor
properinstallationandforproperstovemounting.Thesestandardsarerequired,butnotcompletely.For
furtherandmoredetailedinformationoneneedstoreadtherestofthisinstructionsmanual.
‐Plugthestoveintoanoutletthatisgrounded
‐Theswitchontherearofthestoveissettoposition1
‐Donotallowchildrenorpetstobenearthestove.
‐Usepelletsonly,nototherfuel.
‐Notifyallusersaboutthepotentialrisksanddangersandteachthemhowtohandletheappliance.
Ifthestoveisplacedonawooden floor, thenit is recommended to isolate the pedestal on which it
stands.
Thestoveoperateswithacombustionchamber,whichisinthenegativepressure.Therefore,makesure
thatthesmokeiswellthermallyinsulated.
Whenthestoveisturnedonforthefirsttimethen,duetothestabilizationprocessasmallamount
ofpaint
(notharmfultohealth)thatcoversthestovevaporizes.Itisthereforenecessarytoairthe
roomsothatit
isclearedfromthefumes.
7.3WARNINGSAFETYMEASURESFORSTAFF
MAINTENANCE
Thecontractorswhoworkinmaintenance,inadditiontofollowingallsafetymeasures,must:
‐Alwaysusesafetyequipmentandpersonalprotectiveequipment,
‐Turnoffthepowersupplybeforetheystartworking,
‐Alwaysusetheappropriatetools,
‐Beforetheybegin anyworkonthestovetheyneedtokeepinmindthatitshouldbecoldandthatthe
ashesshouldbecoldaswell.Theyneedtomakesurethehandlesarecoldaswell.
–NEVERTURNTHESTOVEONifthereisjustoneofthesafetydevicesthatisdefective,improperlyset
up
oritdoesnotworkatall.
‐Donotmakemodificationsofanykind,foranyreason,otherthanthosepermittedandexplainedbythe
manufacturerhimself.
‐Alwaysuseoriginalspareparts.Neverwaituntilthecomponentswearoutbeforeyoureplacethem.
Replacing the worn parts or the components of the stove before they stop working contributes to the
preventionofdamage causedbyaccidentsduetosuddenfailure, or breakingof thecomponents,which
canleadtoseriousconsequencesforpeopleand/orpropertylocatedaroundthestove.
‐Cleanthefireboxbeforelightingthestove.
‐Makesurethereisnocondensation.Ifcondensationoccursitshowsthatthereiswaterfromthecooling
smoke.
Werecommendyoufindthepossiblecausestobeabletoestablisharegularandcorrectoperationofthe
stove.
7.4WARNINGSAFETYMEASURESFORTHEUSER
Theplacewherethestoveistobesetup,calledthemountingplace,mustbepreparedbylocal,national,
andEuropeanregulations.
The stove is a “heating machine" and while it is on it has outer surfaces that are very hot or that
achieveveryhightemperatures.
Thisstoveisdesignedtoburnfuelfrompressedwoodmass(apellet withadiameterof6mmwiththe
lengthof30mm,withmaximummoisture8‐9%).
BEARIT Page12
Itisthereforeveryimportanttopayattentiontothefollowingwhenthestoveison:
Donotapproachandtouchtheglassonthedoor,thereisaBURNINGHAZARD
Donotapproachandtouchthesmokedrainpipe,thereisaBURNINGHAZARD
Donotdoanycleanups
Donotopenthedoorbecausethestoveisworkingproperlyonlywhenitissealed
DonotthrowawaytheasheswhenthestoveisON
Childrenandpetsneedtostandawayfromthestove
FOLLOWALLINSTRUCTIONSGIVENINTHISMANUAL
Likewise,theproperuseofbiofuelpelletsmeans:
Onlyusethefuelthatmeetsthemanufacturer'sinstructions,
Alwaysfollowthemaintenanceplanforthestove,
Cleanthestoveeveryday(onlywhenthestoveandtheasharecold),
Do not use the stove in case of any defects or abnormalities, in the case of unusual noise and/or
suspected faults,
Do not spray water on the stove, even when fire fighting,
Donotturnoffthestovebypullingtheplug.Usethebuttonontheboardtoturnoff,
Donottiltthestove,ITMAYBECOMEUNSTABLE,
Donotusethestoveasasupportoraholder.Neverleavethetanklidopen.
DonottouchthedyedpartsofthestovewhileitisON,
Donotusewoodorcoalasafuel,butonlythepelletwiththefollowingcharacteristics:diameterof6‐7
mm,maximumlength30mm,maximummoisturecontent8‐9%,
Donotusethestovetoburnwaste,
Alwaysperformalloperationswithmaximumsecuritymeasures.
7.5SAFETYGUIDILINESFORIGNITIONANDCLEANINGOFTHESTOVE
-
ForturningthestoveONneverusegasoline,keroseneoranyotherflammableliquid.Keepthesetypes
offluidawayfromthestovewhileitisrunning,
-
NeverturnthestoveONiftheglassisdamaged.Donotstriketheglassorthedoorsothattheydo
not
getdamaged,
-
WhilethestoveisON,donotopenthedoortocleantheglass.Cleantheglassonlywhenthestoveis
cold,usingacottonclothorpapertowelandaglasscleaner,
-
Makesurethestoveissecuretopreventanymovement,
-
Makesurethattheashboxisinsertedandthatitisfullyclosed,sothatthedoorsareleaning
properly
onthebox,
-
MakesurethestovedoorisfirmlyclosedwhilethestoveisON,
-
Useavacuumcleanertopulltheashesfromthestoveonlywhenthestoveiscompletelycool,
-
Neveruseabrasivecleanersforcleaningthesurfaceofthestove.
IMPORTANTSAFETYINFORMATION
Themanufacturerisalwaysatyourservicetoprovideyouwithalltheinformationyoumayneed
regarding
thestoveandinstructionsforassemblyandinstallationinyourgeographicalconditions.
Properly
connectingthestove,accordingtotheseinstructions,isveryimportanttopreventthedangerof
fireand
anydefects.
The stove works with a combustion suction pressure. Therefore, make sure that the smoke is well
thermallyinsulated.
BEARIT Page13
DANGER!
Incaseoffireinthesmokeexhaustpipetakeallthepeopleandpetsoutoftheroom,unplugthe
powersupplyusingthepowerswitchinthehouseorremovetheplugfromthewall(plugmustalwaysbe
easilyaccessibleandfreeofobstacles),andimmediatelycallthefiredepartment.
DANGER!
Youcannotuseconventionalfirewood.
DANGER!
Donotusethestovetoburnwaste.
8.0FUELS
TheonlyfuelwhichisallowedforusebytheManufacturerpelletstoveisthewoodenpellets.
Inordertoguaranteecombustionwithoutproblem,thepelletsshouldbekeptinadryplace.We
recommendusageofhighqualitypellets,compactandnotpowder‐like.Informyourselfatyourpellet
vendor,whichpelletsarethebest.Keepthepelletsonadistancefromthepelletstove,notlessthan1,5m
(seechapter5.0).
ATTENTION:Thepelletstoveismanufacturedandtestedonlybyusingcertifiedpellets.Themanufacturer
doesnottakeanyresponsibilityifyouusenon‐certifiedpellets.
9.0TECHNICALSPECIFICATIONS
E
lectricalpowersupply230V,50/50Hz,maximumconsumption13/20mA.
Inputs:Exhaustgastemperatureprobe,Temperatureroomprobe,Temperatureboilerprobe,Differential
pressuresensor(HuboControl),Safetyboilertemperaturethermostat,Safetypellettemperature
hermostat,SafetyPressureswitch,Encoderforcombustionfan,RS232connector. t
Outputs:Combustionfanwithencoder,heatingfan,Igniter,Circulationpump,Augerpelletengine,
CN1Keyboardconnection
Roomspecifications:
O
perativetemperature–from0to40oC,Storagetemperature–from‐10to50oC
Maximumrelativehumidity–95%
INSTALLATION
Allrequiredcablesandconnectorsareputintothepelletstove.Theinstallationisquickandsimple.
Before
eachassemblingofthesystem,anautomatictestofthesystemisperformedforitsproper
operation.
Whenyouturnontheproductforthefirsttime,youshoulddothefollowing:
Whenyouaresurethattheassemblyisproperlydone,itispossibletostartinitialturningONthepellet
stove
thesettingmightbemadeeitherthroughthecontrolpanelorthesoftware.
FornormaloperationofthestoveALLPARAMETERSISSAVEONTHEMOTHERBOARD.
10.0ELECTRONICCOMPONENTSSCHEME
EasyTech.FullisacontrolsystemforpelletstovesavailableintheversionsAirandIdro.Itischaracterisedfor:
installingandusesimplicity
simpleanddirectuser’sfunctions
reliableandflexiblefunctioningsoftwarewithwell‐establishedTiEmmeelettronicatechnology
advancedfunctionsavailableforthebuildertoadapttodifferentstovesandinstallations
Productcomposition:
controlboardwith4fixingpoints,solidandsure
extractableconnectors
exhausttemperatureprobe
roomtemperatureprobe
connectioncablemainboard‐controlpanel
controlpanelwithantistaticcover
Safetyrules
Beforeworkingonthesystemmakefollow:
theaccidentpreventionandroompreventionrules
thenationalinstituterulesagainsttheworkaccidents
thelegalsafetyrules
theseinstructions areonl
y
fortechnical
p
ersonnel onl
y
Conformity declaration
Applied rules: EN 60730-1 50081-1 EN 60730-1 A1 50081-2
This manual is done with care and attention, but the information could be incomplete, not comprehensive or could have mistakes. For this reason
the
design, the information could be modified without advance notice according to he model. t
TiEmme elettronica is not responsible for the incomplete or not correct information
Electrical connections
It is possible to use this control board matching or not an additional module.
BEARIT Page14
BEARIT Page15
PIN Function Technical Specifications
1 L
2 N Voltage Power Supply 230 Vac ± 10% 50/60 Hz
F1= Fuse T5,0 A
3 NN
4 FF Combustion Fan Triac Regulation 0,9 A max
5 NN
6 FF
Output V2 configurable (configuration’s
parameter: P36) Triac Regulation 0,9 A max
7 N
8 F
Output R configurable (configuration’s
parameter: P52) Triac Regulation 1,6 A max
9 N
10 L Auger Pellet Engine Triac Regulation 0,9 A max
11
12 Safety Thermostat Input AT1 Contact ON/OFF Normally
closed
To Bypass if not
13
14 Safety Pressures witch Input AT2 Contact ON/OFF Normally
closed
To Bypass if not
15 Red +
16 Green Exhaust Gas Temperature Probe Thermocouple K: 500 or 1200 °C max
17
18
Configurable Input IN2 (configuration’s
parameter: P74) NTC 10K @25 °C: 120 °C max
19
20 Boiler Probe NTC 10K @25 °C: 120 °C max
21 +5V
22 GND
23 SEG
Encoder Signal (see parameter A57)
Signal TTL 0 / 5 V
24 GND
25 SEG
Configurable Input IN5 (configuration’s
parameter: P70)
26 GND
27 SEG
30 +5V
Configurable Input IN6 (configuration’s
parameter: P72)
-
28 GND
29 SEG
30 +5V
Pressure Sensor
31 +12V - -
32 F - -
33 COM/N
35 NO/FON
34 NC/FOFF
Output Aux1 configurable (configuration’s
parameter: P44)
Relé 3 A max
36 COM
37 NO
Output Aux2* configurable (configuration’s
parameter: P48) Relé 1 A max, free contact output
38 SEG
39 GND
Configurable Input IN8* (configuration’s
parameter: P71) Contact ON/OFF
40 SEG
43 +5V
Configurable Input IN9* (configuration’s
parameter: P76) Contact ON/OFF
41 GND
42 SEG
44 +V
Encoder Fan Signal*
Signal TTL 0 / 5 V
RS232 RS232 Connector Connection for Programmer, Modem, Computer
RS485 RS485 Connector Connection for keyboard, Key Pro
CN1 - -
*only present in the board with the additional module
NOTE: for the outputs Combustion Fan (pin 3-4), Heating Fan (pin 5-6) and R Output (pin 7-8),
the total maximum
consumption must not exceed 3,5 A.
11.0EXPLANATIONOFTHEELECTRONICCONTROLPANEL
LCDVERSION
DisplayLCD100
Themainframeshows:time and date,
chrono activation,
combustion powerand
recipe,,
functioning state, error code,
main
temperature, main thermostat,
summer/wintermode.
Button Function
P1 Exit Menu/Submenu
P2 Ignition and extinguishing (push for 3 seconds), Reset errors (push for 3 seconds), Enable/disable chrono
P3 Enter in User Menu 1/submenu, Enter in User Menu 2 (push for 3 seconds), Save data
P4 Enter in Visualizations Menu, Increase
P5 Activation chrono time band
P6 Enter in Visualizations Menu, Decrease
Led Function
D1 Auger ON D9 External Chrono reached
D2 V2 ON Output D10 Lack of pellet
D3 R output ON D11 Local Room Thermostat reached
D4 Aux1 ON Output D12 Sanitary water demand
D5 Aux2 ON Output
DisplayK100
The main frame shows:
time,
chrono activation,
combustion
power, heating power,
functioning state, main
temperature, main thermostat,
Button Function
K1 Exit Menu/Submenu
K2 Ignition and extinguishing (push for 3 seconds), Reset errors (push for 3 seconds), Enable/disable chrono
K3 Enter in User Menu 1/submenu, Enter in User Menu 2 (push for 3 seconds), Save data
K4 Enter in Visualizations Menu, Increase
K5 Enter in Visualizations Menu, Decrease
Led Function Led Function
Lack of pellet External Chrono reached
Domestic hot water demand Local room Thermostat reached
Winter Summer
BEARIT Page16
BEARIT Page17
DisplayK200
Themainframeshows:
dateandtime,chrono
activation,
combustion power
andrecipes,
functioningstate,
errorcode,main
temperature,
main thermostat
pincipale,
summer/wintermodality
KeysfortheMenuselection:
SystemIgnitionbypressingandholdingfor3seconds AccesstoUserMenu2
AlarmsResetifpressedduring3seconds AccesstoInformationMenu
AccesstoUserMenu1
NavigationKeys:
BacktotheMainFrame ExittheMenuandsavedata
Backtoupperlevel ExittheMenuwithoutsavingdata
ScrollIncreaseofthevalue Scrolltotheleft
ScrollDecreaseofthevalue Scrolltotheright
Led:
TheLedzoneisnotalwaysvisibleinthemainframeofthedisplay.Tomakeitappear/disappear,pressdownon
thedisplay
areacontainingthemaintemperatureorthefunctioningstate.ThevisibleLed’sare:
AugerOn ExternalChronoReached
V2OutputOn Lackofmaterialinthetank
ROutputOn RoomThermostatReached
Aux1OutputOn DomesticHotWaterDemand
Aux2OutputOn
SummerModality WinterModality
TouchScreenCalibration:
TheTouchScreenKeyboardisalreadyfactorycalibrated,butif,inanytime,imprecisionintouchingthescreenstart
to
comeup,anewCalibrationcanbedone.
ToCalibratethescreenfollowtheprocedurebelow:
1.
Turnoffthekeyboard.
2.
Presswithafingeronanypointofthescreenandturnonthekeyboardagain.
3.
Onthescreen,awarningframewillappearsayingKeeptouchingtoforcescreencalibration”.
4.
AfewsecondslaterasecondwarningframewillappearsayingRemovetouchnow”.
5.
Ifeachofthegivencommandsisnotdonewithinafewseconds,theCalibrationprocedurewon’tstartand
thedisplay
willvisualizethemainframe.
OncethecommandsgivenbytheKeyboardarecorrectlyexecuted,theCalibrationprocedurewillstartand
thefig1willappearonthescreen.
6.
Withastylus,orwithfingers,pressonthecentreofthesymbol“+“locatedintheupperleftcornerofthe
screen
7.
Thekeyboardwillstorethecoordinatesofthepointandwillmovethesymbol“+“tothecentreofthescreen
(Fig.2).
8.
Pressagainonthesymbol“+“,thiswillmovetothelowerrightcornerofthescreen(Fig.3).
9.
Oncepressedthislastpoint,theCalibrationprocedureiscompletedandthedisplaywillvisualizethe
mainframe.
Checknow,pressingonthescreen,ifthekeyboardreactstothecommandsgivenmore
preciselythanbefore.
BEARIT Page18
Alarms
DescriptionSystemStateCode
ErrorSafetyHighVoltage1:signalledalsowiththesystemOffBlockEr01
ErrorSafetyHighVoltage2:signalledonlyiftheCombustionFanisOnBlockEr02
ExtinguishingforexhaustundertemperatureBlockEr03
ExtinguishingforwaterovertemperatureBlockEr04
ExtinguishingforexhaustovertemperatureBlockEr05
PelletThermostatopen(flamereturnfromthebrazier)BlockEr06
Encoderfanerror:noEncodersignal(incaseofP25=1or2)BlockEr07
Encoderfanerror:CombustionFanregulationfailed(incaseofP25=1or2)BlockEr08
Lowwaterpressure(theerrorisnotreportedifthe system isin Off orBlockstate and P1
PumpisOff)BlockEr09
HighwaterpressureBlockEr10
DayandtimenotcorrectduetoprolongedabsenceofpowersupplyBlockEr11
FailedignitionBlockEr12
LackofvoltagesupplyBlockEr15
CommunicationRS485errorBlockEr16
AirflowregulatorerrorBlockEr17
RunoutofpelletBlockEr18
BoilerprobeorBufferprobeopenBlockEr23
ErrorEnginecleaningBrazierBlockEr25
AirFlowsensordamagedBlockEr39
MinimumairflowinCheckUpnot reached(FL20)/Test ’Forced Draught Low’ in Check Up
fail(FL71)BlockEr41
Maximumairflowreached(F40)BlockEr42
OpendoorerrorBlockEr44
AugerEncodererror:noEncodersignal(ifP81=1or2)BlockEr47
AugerEncodererror:augerspeedregulationfailed(ifP81=1or2)BlockEr48
ModuleI/OI2CerrorBlockEr52
Messages
DescriptionCode
Anomalyoftheprobeschecking,duringCheckUpphase.Sond
Roomtemperaturegreaterthan99°C.Hi
Thismessagenotifiesthattheplannedhoursoffunctioning(parameterT67)arereached.Clean
DoorOpen.Port
Themessageappearsifthesystemisturnedoffduring Ignition (after Preload) not manually: thesystem
willstoponlywhenitgoesinRun Mode.Ignitionblock
PeriodicalCleaninginprogress.Cleaningon
NocommunicationbetweenmotherboardandkeyboardLinkError
Visualizations
DisplayDescription
ExhaustT.[°C]103Exhausttemperature
RoomT.[°C]25Localroomtemperature;itisvisibleonlyifA19=1
BEARIT Page19
PufferT.[°C]48PufferTemperature,itisvisibleonlyifP26isseton2,3,4
Pressure[mbar]2100Waterpressure
AirFlux750Airflow;itisvisibleonlyifA24isdifferentfrom5
FanSpeed[rpm]1250Exhaustfanspeed;itisvisibleonlyifP25isdifferentfrom0
Auger[s]1.2Augerworktime;itisvisibleonlyifP81isequalto0
Recipe[nr]2Combustionrecipeset;itisvisibleonlyifP04isgreaterthan1
ProductCode:5100000Productcode
User Menu 1
Power
Inthismenuispossibletomodifythecombustionpowerofthesystem.Itcanbesetin
modalityautomaticormanual.Inthefirstcasethesystemchoosesthecombustionpower.In
thesecondcasetheuserselectsthedesiredpower.
Ontheleftsideofthedisplayaresignalledthecombustionmodality(A=automatic
combustion,M=manualcombustion)andtheworkingpowerofthesystem.
Recipe
Menutoselectthecombustionrecipe.Themaximumvalueisthenumberofrecipesvisibleto
theuser(parameterP04).IfP04=1theMenuisn’tvisible.
AugerCalibration
ItallowstomodifythevaluesetinfirmofAuger’sspeedorOntimes.Thevaluesareinthe
range–7÷7.Thefirm’svalueis0
Combustion
Management
FanCalibration
ItallowstomodifythevaluesetinfirmofCombustionFan’sspeed.Thevaluesareintherange
–7÷7.Thefirm’svalueis0.
Boilerthermostat
Menutochangethevalueoftheboilerthermostat.Theminimumandthemaximumvalue
canbeprogrammedbysettingthethermostatsrespectivelyTh26andTh27.
Bufferthermostat
MenutochangethevalueoftheBufferThermostat(Th58);itisvisibleonlyifP26=2,3,4.
Theminimumandthemaximumvaluecanbeprogrammedbysettingthermostats
respectivelyTh51andTh52.
HeatingPower
Itallowstochangethepowerofthefanheating.Thismenuisvisibleonlybysettinganoutput
configurableto6andA04=0.Youcansetthemanagementoftheheatingsystemin
automaticormanualmode.
Heating Description
0FF
 Heatingfanisstopped(itispossibleonlyifP95=0)
1
Poweruser
number
Powerisadjustedmanuallyfrom1tothemaximumnumberofpoweruser
(parameterP03)
Auto
Powerisadjustedautomaticallyaccordingtothevalueofthe
parameterP06
RoomThermostat
ThisMenuallowsmodifyingtheLocalRoomThermostat’svalue.Itisvisibleonlyiftheambient
probeisselect.
Heating
Management
Summer‐Winter
MenuthatallowstheselectionSummer‐Winter
BEARIT Page20
RemoteControl
ThisMenuallowsenablingordisablingtheremotecontrol.
Buttons
Button1activatesextinguishing 
Button2activatesignition
Button3or4decrease/increasethecombustionpower
LearningCode
OntheRemoteController:
• Openthebatterycaseslidingthecovertowardsright
• modifytheconfigurationoftheinternaldip‐switchandclose
OntheControlBoard:
• switchoffthepowersupply
switchonthepowersupplypressingatthesametimeonebuttonontheremotecontrol
waitingabout5secondsuntilanacousticsignalisemittedconfirmingthecodelearned
ManualLoadTheprocedureactivatesthepelletmanualloadingwithactivationincontinuemodalityofthe
Augerengine.Theloadingisstoppedautomaticallyafter600seconds.Thesystemmustbe
OFFforthefunctioncanbeactivated.
CleaningRese
t
Menutoresetthe‘SystemMaintenance2’function.ItisvisibleonlyifT67>0.
EnablingThermostat
Itallowstoactivate/deactivatethefunctionRoomThermostat.
RemoteKeyboard
(onlyonremote
keypad;itisonly
visibleifA52>0)
RoomThermostat
Menutochangethevalueoftheroomthermostatofremotekeypad.
ThisMenuallowsselectingtheprogrammingmodalitiesandandtheIgnition/Extinguishing
timeslots
Modality
Itallowsselectingthe desired modality, or
disable all set
programming.
entermodificationmodethroughthekeyP3
orK3
selectthechosenmodality(Daily,Weekly
orWeek
end)
enable/disablechronomodalitythroughthe
keysP2orK2
savethesettingsthroughthekeysP3orK3
Chrono
(forLCD100and
K100
Keyboards)
Programming
Thesystemincludesthreetypeofprogramming:Daily,
Weekly,Weekend.Afterselectingthedesiredkindof
programming:
‐selecttheprogrammingtimethroughthekeysP4/P6
orK4/K5
‐entertheadjustmentmodality(selectedtimewillbe
flashing)throughthekeysP3orK3
‐changethetimeviakeysP4/P6orK4/K5
‐savetheprogrammingwiththekeysP3orK3
‐enable(a“V”isdisplayed)ordisablethetimeslot(a
“V”isnotdisplayed”)bypressingthekeysP5orK2
Daily
Selectthedayoftheweektoprogramandsetthe
ignitionandextinguishingtimes.
Programsaroundmidnight
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Koper Fox IT 10 User And Service Manual

Category
Stoves
Type
User And Service Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI