Koper Megatron 40 Instructions For Installation, Use And Maintenance Manual

Category
Stoves
Type
Instructions For Installation, Use And Maintenance Manual

Koper Megatron 40 is a pellet stove designed for home heating. It is equipped with a range of features to make it easy to use, efficient, and safe.

The stove has a large hopper that can hold up to 30 kg of pellets, so you don't have to refill it often. It also has a programmable thermostat that allows you to set the desired temperature for your home, and it will automatically adjust the burn rate to maintain that temperature.

The stove is also very efficient, with a burn efficiency of up to 90%. This means that it will use less fuel to heat your home, saving you money on your energy bills.

Koper Megatron 40 is a pellet stove designed for home heating. It is equipped with a range of features to make it easy to use, efficient, and safe.

The stove has a large hopper that can hold up to 30 kg of pellets, so you don't have to refill it often. It also has a programmable thermostat that allows you to set the desired temperature for your home, and it will automatically adjust the burn rate to maintain that temperature.

The stove is also very efficient, with a burn efficiency of up to 90%. This means that it will use less fuel to heat your home, saving you money on your energy bills.

[INSTRUCTIONSFORINSTALLATION,USEANDMAINTENANCE]
Thisusermanualisanintegralpartoftheproduct
MEGATRON 40
2
INDEX
SECTIONTITLEPAGE
Introduction3
Purpose3
1
Importantrecommendations3
2
Safety3
3
Installation4
3.1.Responsibilityoftheinstaller4
3.2.Permittedinstallations4
3.3.Nonpermittedinstallations5
3.4.Chimney5
3.5.Chimneyend6
3.6.Insulation,finishes,coatingsandrecommendationsforsafety7
3.7.Hydraulicconnections7
3.8.National,regional,provincialandmunicipalregulations8
4
Pelletandpelletloading8
4.1.Pelletquality8
4.2.Pelletstorage10
4.3.Pelletloading10
5
Operation10
5.1.ControlBoard11
5.2.TheMenu15
5.3.FunctioningStates21
5.4.OtherFunctions21
6
Connections22
6.1
Installationofexternalthermostat22
6.2.Checkofthermostatproperconnection22
6.3.Circulatorconnection22
6.4.Supplyconnection22
6.5.Componentsconnectiondiagram23
7
Technicaldata24
8
Maintenance24
8.1.Firebox25
8.2.Ashpan25
8.3.Flamechamber25
8.4.Exhaustsystem26
8.5.Fluegasfan26
8.6.Nonoperationperiod26
MEGATRON 40
3
INTRODUCTION
Pleasereadthoroughlythismanualbeforeinstallingandusingthisproduct.
Thepelletsheatersaremanufacturedandtestedinaccordancewiththesafetystandardsofthe
applicableEuropean
Directives.
Thismanualintendstogiveinstructionsfortheuseandmaintenanceoftheproductstotheirownersand
the
installationtechnicians.
Ifyouhaveanydoubtsastothecontentsorforanyotherquestion,pleasecontactanauthorizedservice
center.
PURPOSE
Thepurposeofthismanualistoallowtheusertotakeallpossiblemeasuresandprepareallequipment
and
materialstoensurethesafeandcorrectuseoftheproduct.
1. IMPORTANTRECOMMENDATIONS
Theinstallationshouldbeperformedbytrainedpersonnelorbythetechnicalsupportofthe
manufacturer,taking
fullresponsibilityforthefinalinstallationandsubsequentsmoothoperationofthe
installedproduct.Itisalso
necessarytoconsiderallnational,regional,provincialandmunicipallawsand
regulationsofthecountrywherethe
deviceisinstalled.Therewillbenoliabilityofthemanufacturerfor
failuretocomplywiththeseprecautions.
1.
Electricalconnections:itisthereforerecommendedtotheauthorizedpersonnelafterevery
operation
conductedontheproduct,topayparticularattentiontoelectronicconnections,
notablytothepointofbare
conductorswhichmustnotexittheterminal,thusavoidingpossible
contactwithlivepartsoftheconductor.
2.
Correctuse:theboileristobeusedforthepurposesforwhichitisbuilt.
3.
Responsibilityofthemanufacturer:Themanufacturerassumesnocontractualornon
contractualliability
fordamagecausedtopersons,animalsorthings,frominstallationerrors,
improperuseandmaintenance.
4.
Verifytheintegrityoftheproduct:Afterremovingthepacking,checktheintegrityand
completenessofthe
contents.Incaseofdiscrepancies,pleasecontactthedealerwhereyou
purchasedthedevice.
5.
Electricalcomponents:Allelectricalcomponentsthatmakeuptheproducttobeableto
guaranteethecorrect
operationandshouldbereplacedwithgenuinepartsonlyfromauthorized
serviceprovider.
6.
Maintenance:Dailyandmonthlymaintenanceoftheproductshouldbemadebythebuyerand
atleastonce
ayear,planningitinadvance,byspecializedstafforthetechnicalsupportofthe
manufacturer.
2.SAFETY
For safety reasons, remember that:
Theusetheboilerbypeople(includingchildren)withnoexperienceorwithreducedphysical
andmental
capacity,ifnotsupervisedandarenotguidedintheuseoftheappliancebya
personresponsiblefor
theirsafety,isnotpermitted.
Youshouldcheckandmakesurechildrendonotplaywiththeappliance.
Donottouchtheboilerwhenbarefootorwithwetandmoistareasofthebody.
Donotmodifysafetyequipmentorsettingswithoutthepermissionorthemanufacturer's
instructions.
Donotpull,donotturnandcutofftheelectricalwiresprotrudingfromtheboilerevenifitis
disconnectedfromthenetwork.
Werecommendthatyouputthepowersupplycableinplacenotincontactwiththehotparts
ofthe
appliance.
Thesupplyplugmustbeaccessibleafterinstallation.
Avoidclosingorreducingthesizeofventilationopeningsattheinstallationsite,theventsare
necessary
forpropercombustion.
Donotlettheelementsofthepackagenearchildren.
Duringthenormaloperationoftheproductalldoorsandlidsshouldalwaysremaintightly
closed.
Whenthedeviceworksitiswarmtothetouch,especiallytheexternalsurfaces.Weadvise
youtousein
MEGATRON 40
4
caution.
Checkforobstructionsbeforeturningonthedeviceifithasbeenoutofoperationforalongtime.
Incaseofparticularlyadverseweatherconditions(strongwind,frost)itislikelythatsafety
systems
interveneandturnofftheboiler.Ifthishappenspleasecontacttechnicalsupportand
NEVERdisablesafety
devices.
Incaseoffireinthefluewayobtainthemeanstosuppresstheflamesorseektheintervention
ofthefire
service.
Thisdeviceshouldnotbeusedforburningwastes.
Donotuseflammableliquidsforignition.
Whenfilling,donotbringyourpelletsackincontactwiththeproduct.
3.
INSTALLATION
3.1RESPONSIBILITYOFTHEINSTALLER
Responsibilityoftheinstalleristoperforminspectionsoffluepipes,airinletandalltheelectricaland
hydraulic
solutionsrequiredforyourpelletboiler.Responsibilityoftheinstallerisalsotoensure
compliancewithcurrentspecial
locallawswheretheboilerisinstalled.
Theuseofthepelletboilershouldtakeplaceincompliancewiththedirectionsgivenbythisdocumentand
byall
maintenanceandsafetystandardsinlinewithcurrentspeciallegislation,validwheretheboileris
installed.
Accordingtothestandardsthatdefinetheobligationsofinstaller,theinstallershouldconfirm:
Thetypeoftheinstalledunit
Thecompatibilityoftheinstallationspacewiththeunit,expressedasminimumvolume
installation
accordingtothemanufacturer'sinstructions.
Theinstructionsoftheboilermanufacturerregardingtheconditionsofsmokeremoval
system
(fluepipesorflueways).
Theinternalcrosssectionofthestack,thematerialofwhichithasbeenconstructed,equal
cross
sectionaldimensions,lackofobstructions.
Theheightandverticalextensionofthechimney.
Theheightabovesealevelatthesite.
Theexistenceandadequacyofwatertightclosure.
Thecapacityofexternalairinletsandthesizesofexistingones.
Thepossibilityofparalleluseofthegeneratorsystemwithpreexistingotherequipment.
Iftheresultsofalltestsarepositive,theinstallationcanproceed.Carefullyobservethe
instructionsprovided
bythemanufacturerandcurrentsafetyandfiresafetystandards.
Onceinstallationiscomplete,thesystemshouldbetestedfornolessthan60minutesforall
functionstobe
checked.
Oncetheinstallationandtrialoperationarecompleted,theinstallershouldprovidethecustomer
withthe
following:
Theuseandmaintenanceformoftheunitassuppliedbythemanufacturer(ifnot
already
providedwiththeunit)
Therequireddocumentationforcompliancewiththecurrentstandards.
3.2PERMITTEDINSTALLATIONS
Atthelocationwheretheboilerisinstalled,mayalreadyexist,ormaybeestablishedonlydevicesthat
poseno
recessioninspaceinrelationtotheexternalenvironment.
MEGATRON 40
5
3.3NON‐PERMITTEDINSTALLATIONS
Intheareawhereyouneedtoinstalltheboilermustnotalreadyexistorbeinstalled:
Hoodwithgassuction.
Ventilationductswithgassuction.
Ifthesedevicesexistinareasadjacenttotheinstallationsite,thesimultaneoususeoftheboiler
ispermitted
becauseoftheriskthatoneofthetwoareasfallsintorecession.
3.4CHIMNEY
Toassemblethestacknonflammablematerialsmustbeused
suitableto
withstandthecombustionproductsandany
condensation.
Theuseofflexiblemetaltubesandfibercementtoconnect
theflueof
theboilerisprohibited.
Thechimneymustnotcrossareaswhereinstallationof
combustion
appliancesisprohibited.
Theplacementofthechimneyshouldbedoneinsuchaway
astoensure
theoperatingconditionsofthedevice,toreduce
theformationof
condensateandavoidtheirtransfertothe
device.
theplacementofhorizontalsectionsshouldbeavoidedas
muchaspossible(allowablelimit3m). Fig.1
Fordevicesthatmustreachthetoporthewallthedirectionchangesmustbemadewithopen
elbowsno
morethan45°orangled90°(nomorethan3intotal).
Theuseofreverseinclinationcomponentsisprohibited.
Itisrecommendedthatthechimneyhasacollectionchamber
forsolid
materialsandanycondensate,locatedbelowthe
inletofsmokepipe,so
thatitcaneasilybeopenedand
inspected(Fig.2).
Itisforbiddenforotherairductsandpipingtopassinsidethe
smokepipe,
evenifitisoflargesize.
Itmustbeproperlyspacedfromcombustiblematerials
througham
insulatinglayerofairorproperinsulation(Fig.3,
4,Table1).
Thechimneymustacceptthedischargefromasingleboiler.
Thedirectindoorsdischargeisprohibitedeveninroomswith
openceiling.
Fig.2
Fig.3   Fig.4
MEGATRON 40
6
SYMBOL Flammable
materials Non-
Flammable
materials
A 200 mm 100 mm
B 1.500 mm 750 mm
C 200 mm 100 mm
Table1
ThesmokedischargesystemSHOULDNOTbeconnected:
Influewaysusedbyothergenerators(boilers,furnaces,fireplaces,etc.)
Airexhaustssystems(hoods,airportsetc.)evenifenclosedinpipes.
The draught of the chimney must be 10 – 15 Pa !!!
Fig.5   Fig.6
3.5CHIMNEYEND
Thechimneyendmustmeetthefollowingrequirements:
haveinnersectionequaltothatofthestack.
haveusefuloutletsectionnotlessthantwicethatoftheinteriorofthechimney.
beconstructedinsuchawayastopreventthepenetrationofrain,snow,foreignbodiesinthe
chimney,and
toguaranteethedischargeofcombustionproductsevenincaseofwindsofany
directionandinclination.
bepositionedinsuchawayastoensureproperdispersionanddissolutionofthecombustion
productsand
certainlyoutsidetheregressionareawheretheformationofoppositepressuresis
favored,suchareahas
differentsizesandconfigurationsdependingonthetiltangleofthe

cover.
Theendofthestackmusthavenomechanicalsuction.
MEGATRON 40
7
Thecoatingsregardlessofthematerialtheyaremademustbeaselfsupportingstructurewithrespectto
the eated
Beamsandfinishesofwoodorflammablematerialsmustbeplacedoutsidetheradiationareaofthe
boilerorbe
Ifcoversmadeofflammableorheatsensitivematerialexistinthespaceabovetheboiler,aprotective
barrierof
Componentsmadeofcombustibleorflammablematerialsuchaswoodenfurniture,curtains,etc.thatare
directly
Thisappliancehasbeendesignedtoheatwaterforahotwatertypeheatingsystem.
isnecessarilybelow
boilingpoint
Aqualifiedheatingplumbermustbecalledinto:
checkanexistingheatinginstallation.
installation.
Thewaterheatingsystemmustbesizedinrelationtotheaveragepoweroftheapplianceandthe
heating
h
3.6INSULATION,FI N I S H ,
COATINGANDSAFETY
RECOMMENDATIONS
systemandshouldnotbeincontactwithit.
sufficientlyinsulated.
insulatingornoncombustiblematerialshouldbeplaced.
exposedtotheradiationofthefireshouldbeplacedatasafedistance.Thedeviceinstallation
mustguaranteeeasy
accessforcleaningthedeviceitself,pipelinesandgasdischargepipes.
3.7HYDRAULICCONNECTION
Whentheapplianceisoperatingregularlyitproduceshotwateratatemperaturethat
andaheatingsystemmustthereforebedesignedthatissuitedtothecharacteristicsofthe
appliance.
design,installandcheckanewheating
requirementsofthebuilding(see“TECHNICALDATA”).
Thefittingsforconnectingtheappliancetotheplumbingsystemaretobefoundattherear.Connections:
facilitateany
Shouldthetemperature/pressurereliefvalveactivate,thewatermustbefreetoflowawaywithout
causinginjury
Installingshutoffvalvesontheinletandtheoutletenablemaintenancetobecarriedout
without
stpointsofthesystemmakeiteasiertodrainthesystemif
necessary.
m.
um
sothatitcanbemovedslightly(checkthatanykinks
inthehose
ancedeliveryorreturnfittingstochecktheworkingpressure
ofthe
theappliancepressure/temperaturereliefvalvetoasuitabledripfunneltotakeaway
waterat
eterofthepipework.
thattheydonotweighonthefittingsofthe
unit.
rm,
ingpipeworkadequatelytopreventheatlossandtheformationof
stanceslighttheapplianceunlessthewatercircuitiscompletelyfilledwith
water.
Connecttheappliancetotheheatingplumbingsystem(supplyreturn)usingpipeunionsandstopvalvesto
futuremaintenanceordrainingoftheheatingsystem.
toperson,damagetopropertyortotheelectricalpartsoftheboiler.
havingtodrainthesystem.
Draintapsinsertedinthelowe
Airvalvesinstalledatallthehighestpointsofthesystemmakeiteasiertobleedtheheating
syste
Donotinstallthermostatsonalltheheaters(radiators)oftheheatingsystemsothatatleast
theminim
outputoftheappliancecanbedissipated.
Usesectionsofhosetoconnecttheboiler
donotallowairpocketstoform).
Installamanometerneartheappli
system.
Connect
highpressureandtemperature.
Avoidanynarrowinginthediam
Avoidusingelbowsorbendswithasmallradius.
Provideadequatesupportsforthewaterpipesso
Beforeconnectingtheappliance,flushtheheatingsystemthroughtoeliminateanyresidues
(oil,swa
dropsofweldmaterial,hemp,rust)insidethepipework,whichcouldotherwise
damagetheboileror
causemalfunction.
Insulatetheconnect
condensation.
Undernocircum
MEGATRON 40
8
HYDRAULIC DIAGRAM
fthistype,itis
im
for the resulting
improper
fu
peration, you must:
erentfromthoseprovidedbythemanufacturer.
ves)
Itisalso provincialandmunicipallawsandregulationsof
3.8NATIONAL,REGIONAL,PROVINSIONAL
ANDLOCALREGULATIONS
necessarytokeepinmindallnational,regional,
thecountryinwhichthedeviceisinstalled.
4.PELLETANDPELLETLOADING
ATTENTION!!!
THEUSEOFPELLETSNOTIN STANDARDS,ANDTHEUSE
ACCORDANCEWITHTHE
OFOTHERCOMBUSTIBLEMATERIAL,HARMSTHEPROPERFUNCTIONOFYOUR
PRODUCTANDMAYVOIDTHEWARRANTEEANDTHEATTACHED
MANUFACTURER’SRESPONSIBILITY.
Thepelletboilerisdesignedtousecompressedwood‐pellets.Sincethemarkethasmanyproducts
4.1PELLETQUALITY
o
portanttochoosepelletwithhighstandards.Thelinktotheburningcompressedwoodhasestablishedamodelfor
thatfuelproduct.
Besuretousequalitypelletthatiscompactandhaslowconcentrationofdust.Askyourdealerfortheappropriate
pellet,thediameterofwhichshouldbe6mmanditslengthabout30mm.Theproperfunctioningofthepelletboiler
dependsonthetypeandqualityofthepelletused,andtheheatgeneratedbythedifferenttypesofproductscanhave
varyingdegreesofefficiency.Werecommendpelletwith
specificationsaccordingtoÖNORMM1735,DINplusEN14961.
manufacturer shall not be liable for the use of low quality pellet andThe
nction of the boiler.
To ensure smooth o
‐Avoidusingpelletswithdimensionsdiff
‐Avoidusingpellets,containingsawdust,bark,corn,resinsorchemicals(additives,adhesi
‐Avoidusingwetpellets.
MEGATRON 40
9
duceotherresidualsexceptashesafterburning. 
ueway.
tectiveglass
eden Germany Italy EU
‐Avoidusingpelletsthatpro
Usingunsuitablepelletscauses:
‐Obstructionsoftheburnerandfl
‐Reductioninefficiency.
‐Excessivedirtonthepro
‐Unburnedgrainsandheavyash.
Specifications Units Austria Sw
ÖNORM
M1735 SS187120 DIN 51731 DIN plus CTI EN 14961-1
Diameter mm 4-10 To be
refe
4-10 4-10 6 6-8
renced
Length mm 5* 4* 50 5*D -4*D 3,15-40
Density Kg/m3 - 600 - - 620-720 600
smithereens % of
mass
1 - - -
1 1
Moisture
mass
10
10
12
10
10 10
content
% of
Ash content % of
mass
0,5
0,7
1,5
0,5
0,7
0,7
Calorific value MJ/kg 18 16,9 17,5-19,5 18 16,9 16,5-19
Sulfur % of
mass
0,04
0,08
0,08
0,04
0,05 0,03
Nitrogen mass
0,3 -
0,3
0,3
0,3 0,3
% of
Chlorine % of
mass
0,02
0,03
0,03
0,02
0,03 0,02
Arsenic mg/kg - - 0,8 - - 1
Cadmium mg/kg - - 0,5 - - 0,5
Chromium mg/kg - - 8 - - 10
Copper mg/kg - - 5 - - 10
Mercury mg/kg - - 0,05 - - 0,1
Lead mg/kg - - 10 - - 10
Zinc mg/kg - - 100 - - 100
Nickel mg/kg - - - - - 10
Additives %
2 To be
referenced
-
2 To be
referenced
2
MEGATRON 40
10
Theelletsshouldbestoredinadryplacethatisnottoocold.Essentially,coldandmoistpellet(of
temperature
lenergyofthefuelandrequireextracleaningofthepellet
boiler.
Donotloaddustandsawdustbecauseitcanblockthesupplysystem.
andonlybeopenedduringloadingoffuel.
p
4.2PELLETSTORAGE
below10ºC)reducethetherma
THEPELLETSHOULDNOTbekeptneartheboiler.Keepatleast0,5m1maway.
4.3PELLETLOADING
Cautionwhenloadingthepellettopreventsnapping.
pelletsincontacttotheboilerchassis.
Avoidbringingthepackof
Thepelletsreservoircovermustalwaysremainclosed
5. OPERATION
TURNING ON PROCEDURE
1.
Load the silo with pellet
2.
Check and clean the combustion container
4.
Choose the combustion power (1 to 6 or Auto if you wish the power to be set automatically)
according to
ired power (set)
ice
e of the stove:
agement” (set)
c.
Choose “Boiler Thermostat” (set)
ice
on the stove
performs a check and cleaninig
ce preheat
The flame is lit (if it doesn’t after 25 minutes the error message er12 is shown on the LCD
display)
on state
3.
Close the doors tightly
the following steps:
a.
Press P3 (set)
b.
Choose “Combustion Management” (set)
c.
Choose “Pellet” (set)
d.
Set the des
e.
Press P1 (Esc) tw
5.
Choose the desired water temperatur
a.
Press P3 (set)
b.
Choose “Heating Man
d.
Set the desired water temperature (set)
e.
Press P1 (Esc) tw
6.
Press the P2 button for 3 seconds in order to turn
For half a minute the stove
For 1 – 1,5 minute the stove performs ignition and resistan
After that, it fills the combustion container with pellet
When the exhaust temperature exceeds 45oC the stove goes to Stabilizati
After 7 – 10 minutes the stove goes to Run Mode
MEGATRON 40
11
chambervacuum
Combustion
Thesystemoperatesmaintainingavacuuminthecombustionchamber
ithinacertainrange.Therefore,thecombustionchamberdoormustbetightly
er34messagewillbedisplayedonthescreenafter50
w
closed.Ifitremainsopen,the
60sec.
Buttons
Function Description Button
On/Off Ignition and Extinguishing of the boiler/stove pushing the
button for 3 seconds until the acoustic signal
Unblock
Unblock the system pu n for 3 seconds until
shing the butto
the acoustic signal P2
Modify Menu Values In modify mode change parameter’s value
Run on Menu and Submenu menu Run Menu and Sub
Visualizations Enter visualization menu
P4
P6
Esc Function exit P1
Menu Enter a menu or submenu
Modify Enable modify mode in a menu
Set Save data
P3
Reset System Maintenance 2
P5
Function Reset cleaning timer
s
FDescription Bu
Led
unction tton
Heating Resistance Led On: Heating Resistance On D1
ALed On: Auger On in intervals D2 uger
Circulator Led On: Circulator On D3
Valve Led On: Valve On (Not Used) D4
Output V2 Led On: Output V2 On (Not Used) D5
5.1CONTRO LLPANE
MEGATRON 40
12
2 ot Used)
Output Aux Led On: Output Aux2 On (N D6
Output Aux3 Led On: Output Aux3 On (Not Used) D7
Pellet Level
Led On: Lack of pellet (Not Used) D10
External Thermostat Led On: Contact Open – Thermostat Off D11
Flow switch Led On: Domestic water demand (Not Used) D12
 

Display
VisualizationsonMainFraime
Dateandtime,
BoilerThermos
chronomodality(DDaily,WWeekly,WeWeekEnd),systempower,recipe,systemstate,errorcode,
tat,watertemperature
Systemstates
CheckUp,Ignition,Stabilization,RunMode,Modulation,Standby,Safety,Extinguishing,RecoverIgnition,Block,Off
RORMESSAGEONTHESCREENREMOVEANER
Performthecorrectingactionsaccordingtothecauseoftheerror
WaituntiltheBlockmessageisdisplayedonthescreen
PressP2forsomesecondsuntiltheerrormessagedisappears
RestarttheappliancepressingP2
Errors
AllerrorsresultinBlocksystemstate,excepttheEr04andEr05errors,thatinWoodmodalityresultinSafetystate
Er01
Hughwatertemperature.Over100οCsafety
thermostatisenabled.
Unblockthewatersafetythermostat
Overeating
Waituntilthewatertemperaturedrops
andthesystemgoestoBlock
dhold
PressP2an
Restartthesystem
Er02
Chimneywithoutdraught.Depressurizeswitch
is
enabled.
echimney is
his
replacethe
depressurize switch
Low draught. The draughtofth
notadequateorthedepressurizeswitc
broken.
‐Cleanthechimneyor
Display
Main Frame
MEGATRON 40
13
Er03
Extinguishingwhentheexhausttemperature
dropsbelowthesetvalue(70οC)
l
lisnottransferredcorrectlyinthe
rdueto
tions).Cleantheauger
Lowexhausttemperature
Thesystemranoutoffuel.Loadmorefue
Thefue
combustionchamber(blockedauge
dustorotherobstruc
Er04Extinguishingwhenthewatertemperature
exceedsthesetvalue(90οC)
Wateroverheating
‐WaituntilthesystemgoestoBlock
PressP2andhold
Restartthesystem
Er05
Extinguishingwhentheexhausttemperature
exceedsthesetvalue(280οC)
Highexhausttemperature
mgoestoBlock
Waituntilthesyste
Performthemonthlymaintenance
cleaning
PressP2andhold
Restart the system
Er07
Encodererror.Occursincaseoflackofencoder
signal.
icate
fanencoder
cleaning
n
broken
Encoderproblem
Thecontrolboarddoesnotcommun
withtheexhaust
Theencoderneeds
Theencoderisbroke
Theexhaustfanis
Er08
Encodererror.Occursincaseoffanroundsper
minuteadjustmentproblem
n
Fanrotationproblem
Theencoderneedscleaning
Theencoderisbroken
Theexhaustfanisbroke
Er09Lowwaterpressure‐
Er10Highwaterpressure‐
Er11
Realtimeclockerror
WaituntilthesystemgoestoBlock
PressP2andhold
Restartthesystem
Er12
ExtinguishingduetoIgnitionfailure
nitionfailure
combustioncontainerneedscleaning
cepowerislow
sistanceisbroken
low
dby
er,pressP2
Ig
The
Thecombustioncontainerisnot
positionedcorrectly
Theignitionresistan
Theignitionre
Highmoisturecontentinpellet
Thepellethopperisempty
Pellettemperaturetoo
Theignitionresistancetubeisblocke
ash
Cleanthecombustioncontain
andhold,restartthesystem
Er15
Lackofvoltage
nthecombustioncontainer
WaituntilthesystemgoestoBlock
Powersupplyoutage
Clea
PressP2andhold
Restartthesystem
Er17AirFlowRegulatorError‐
Er18Runoutofpellet‐
MEGATRON 40
14
Er34
Vacuumbelowtheminimumthreshold
Lowvacuuminthecombustionchamber
Thecombustionchamberdoorisopen
Thecombustionchamberdoordoesnot
closetightly
Thesystemandthechimneyneed
cleaning(monthlymaintenance)
Lowchimneydraught(below10Pa)
Theexhaustfanisbroken
Thecombustionfanpoweristohigh
Callservice
Er35VacuumovertheminimumthresholdHigh vacuum in thecombustionchamber.
Call service
Er39AirFlowRegulatorSensorbrokenVacuumsensorbroken.
Call service
Er41Minimum air flow in Check Up not reached -
Er42Maximum air flow reached -
Othermessages
Sound
Visualization of the state of temperature probes.
The message displayed in Check-Up indicates
that the red temperature of one or more probes is
equal to the minimum value (0°C) or maximum (it
depends on probe considered).
Checks that the probes aren’t open (0°C) or in
short-circuit (maximum value of the temperature
scale).
- Check the water, room, exhaust sensors
Service
This message notifies that the planned hours of
operation until service (parameter T66) is
reached. Service is necessary.
The system needs annually service
(cleaning)
-
Perform the annually service
-
Reset the timers (system menu -> Timers -
> Reset all timers)
-
Press P2 and hold until the service
message disappears
CleanThismessagenotifiesthattheplannedhoursof
operationuntilcleaning(parameterT67)is
reached.Cleaningofthestove/boileris
necessary.
Cleanthecombustionchamber
PressP5andholduntilthecleaning
messagedisappears
IgnitionBlockThe message appears if the system is turned off
during Ignition (after Preload) by an external
device: the system will stop only when it goes in
Run Mode.
- Restart the system
Er20Grid Sensor open with the system in Pellet
modality -
PortHighfueltemperature.Fuelthermostatis
enabled
Fueloverheating
Performthemonthlycleaning
Unblockthefuelsafetythermostatby
pressingitsbutton
Restartthesystem
Ifthiserrorpersistscalltheauthorized
dealer
Er06Pelletthermostatopen‐
LinkErrorLackofcommunicationbetweenmotherboard
andkeyboard
‐Checkiftheconnectioncableis
disconnectedfromtheLCDdisplayorthe
controlboard
Visualizations.PressingthebuttonΡ4orΡ6
L3OnPumpP1Lednumberandpumpstate
L4OffValve/PumpP2Lednumberandvalvestate
L5OffOutnotpresLednumberandOutputV2state
L6Of
f
SafetyValveLednumberandOutputAux2state
L7OffPelletEngineLednumberandOutputAux3state
MEGATRON 40
15
ExhaustTemp:103Exhausttemperature
BoilerTemp:55Boilertemperature[°C]
BufferTemp:52Buffertemperature[C](Notused)
RoomTemp:21Roomtemperature[°C](Onlyforstoves)
Pressure:1548Pressure[mbar](Notused)
Airflow:580AirFlow[cm/s](Notused)
Vacuum:280Vacuum[Pa]
Fanspeed:1850CombustionFanSpeed[RPM]
Auger:30AugerSpeed[%]orAugerworktime[s]
ProductCode457–00.00ProductCode
FSYSD01000123.0.0Controlboardfirmware,codeandversion
PSYSF01000184.0.0Keyboardfirmware,codeandversion
5.2THEMENU
The Menu of the control panel consists of a User Menu and a System Menu in which the manufacturer can
modify the
operating parameters, test the outputs, check the history of the system.
Browsing the menu:
Push P3 button to enter the User Menu.
UsingP4andP6buttonsitispossibletoselectthedesiredMenuorSubmenu.PushP3buttontoenterthe
desired
MenuorSubmenu.
To decrease or increase a value, push the buttons P4 or P6. To save the new value push the button P3. To
cancel any
changes and restore the old parameter’s value push the button P1.
If a parameter value is changed, the new value is sent to the control board. If the transmission fails the
following
message is displayed:
MEGATRON 40
16
Transfer
not successful
In this case modify again the parameter’s value.

MENU DESC
Functioning Menu to choose between Wood/Pellet/Combi functions.
Pellet Power Menu to modify the combustion power in Pellet function.
Wood Power Menu to modify the combustion power in Wood function.
Pellet Recipe Menu to set the pellet combustion recipe.
Auger Calibration Menu to modify the speed or working time of the Auger.
Combustion
Management
Fan Calibration Menu to modify the Combustion Fan speed.
Boiler Thermostat Menu to modify the boiler thermostat value.
Buffer Thermostat Menu to modify the Buffer thermostat (Notused)
Room Thermostat Menu to modify the room thermostat value (If a probe is
used) (Only for stoves)
Summer – Winter Menu to select between Summer and Winter function.
Heating Power Menu to modify the heating power.
Heating
Management
Remote Keyboard Menu to enable the Room Thermostat of the remote
keyboard (Notused)
Chrono MenutoselecttheChrono’sprogramandthetimersfor
Ignition/Extinguishingoftheboiler/stove
Load Menu for auger loading
Time and Date Menu to set the time and date
Language Menu to change the language of the LCD display
Keyboard Menu Menu to set the contrast and light of the LCD display
System Mennu Menu to enter the system menu
5.2.1COMBUSTIONMANAGEMENTMENU
This menu is used to change the combustion parameters. It includes the following submenus.
MEGATRON 40
17
FUNCTIONING
This menu is used for changing the function of the appliance between WOOD/PELLET/COMBI functions.
Only the pellet option is available.
PELLETPOWER
This Menu allows the setting of the system’s combustion in automatic or manual mode. If the
manual
mode is set, the user can choose the combustion power between values P1 and P6. If
the automatic
mode is chosen the system sets the combustion power automatically.
Combustion Description
1 – 6 Power manually from 1 to 6
Auto Power set automatically
COMBUSTIONRECIPE
This Menu allows to select the combustion recipe in Pellet modality. The maximum value is the
number of
recipes visible to the user.
AUGERCALIBRATION
Menu to change the Auger’s work time or speed. The system has 10 calibration’s steps (0 value is
set by
the factory). The calibration’s effect is valid only in Run Mode and Modulation for the current
recipe. For
each step the value is increased or decreased by 1% set in the Default Settings
Menu of the System
Menu.
FANCALIBRATION
Menu to change the Combustion Fan speed. The system has 10 calibration’s steps (the 0 value is set by
the
factory). The calibration’s effect is valid only in Run Mode and Modulation for the current recipe. For
each step
the value is increased or decreased 5% set in the Combustion Fan Menu of the System Menu.
5.2.3HEATINGMANAGEMENT
Menu to change the system’s heating parameters. It includes the following submenus.
MEGATRON 40
18
Menu which allows to modify the Boiler Thermostat’s value. It is possible to program the minimum and the
maximum value of the Boiler Thermostat.
ves).
Menu which allows to modify the plumbing plant functioning according to the season. One of these symbols:
BOILERTHERMOSTAT(DESIREDWATER TEMPERATURE)
ROOMTHERMOSTAT(ROOMTEMPERATURE)
Menu which allows to modify the Room Thermostat’s value (only for sto
SUMMER
WINTER
or
is shown on the display.
the system’s heating function in automatic or manual mode (in this case it is
possible for the user to select the heating power).
Description
HEATINGPOWER
This Menu allows to set
Heating
0HeatingFanOff
1PowersetbyuserHeatingpowermanuallyfrom1touserselection
AutomaticHeatingpowerautomaticallysetbythesystem
If the user chooses the automatic mode, the heating is proportional to the exhaust temperature.
nu which allows to enable the Room Ther e Keyboard.
gramming of turning on/off the system.
DESCRIPTIONBUTTONS DISPLAY
REMOTEKEYBOARD
Me mostat of the Remot
5.2.4CHRONOMENU
Menu which allows the pro
CHRONOFUNCTION
Thecurrentsettingblinks
EnterinmodificationmodeP3
SelectfavoritefunctionP4andP6
CancelanyadjustmentandrestoretheprevioussettingP1
SavethenewsettingP3
Exitthemenu
Disable
Daily
Weekly
WeekEnd
P1
PROGRAMSELECTIONBUTTONS SPLAYDI
Thecurrentsettingblinks Daily
EnterthesubmenuP3
SelectfavoriteprogramP4andP6 Weekly
Week
End
CHRONO PROGRAM
MEGATRON 40
19
P1Exitthemenu
T ming are stored separately: if for example the Daily p s set, th
ot anged. After making the programming it is neces y to e desire
mode em by Chrono.
C m type:
Daily: select the day of week and program the times to switch on and off the system. For each day there
are
3 time slots.
he three types of program rogram i
select th e
dher
programs aren’t ch sar
to
turn on/off the syst
hoose the progra
Program across midnight: set the time of extinguishing of a day at 23:59 and the time of ignition for the
next
day at 00:00.
Weekly: program the times to switch on and off the system (there are 3 time slots).
Week-End: choose between 'Monday-Friday' and 'Saturday-Sunday'. There are 3 time slots for each period.
CHRONOPROGRAMMINGΠΛΗΚΤΡΑ
Afterchoosingthefavoriteprogram,selecttheprogrammingtime.P4ήP6
Enterinmodificationmode(theselectedtimeblinks)P3
Modifythetimers.P4ήP6
SavetheprogramP3
Enableaprogram(a“V”appears)ordisableaprogram(a“V”disappears)P5
ExitP1
ystem has to be in off state the loading.
nually started the Exhaust Fan switches on.
This menu allows to manually loading the Auger. The s to do
When
the Auger is ma
5.2.5LOADMENU
MEGATRON 40
20
MEDESCRIPTION
This Menu allows to set the time and date. Push the button P4 and P6 to select hours, minutes, year, month
5.2.6TIMEANDDATEMENU
and day. Push P3 to enter editing, P4 and P6 button to change the value. Push P3 to save and P1 to exit.
This Menu allows changing the language of LCD panel. The highlighted language is currently set.
5.2.7LANGUAGESELECTION
5.2.8LCDMENU
SetContrastMenutosetthecontrastoftheLCDpanel
SetminimumLightMenutosetthelightoftheLCDpanel
This Menu allows to set t ay contrast.
SETCONTRAST
he displ
Push the buttons P4 and P6 to increase or decrease the contrast; P3 to save and exit, P1 to exit without
saving.
This Menu allows setting the display light when any button is pushed.
SETMINIMUMLIGHT
Push the buttons P4 and P6 to increase or decrease the light, P3 to save and exit, P1 to exit without saving.
This menu allows entering System Menu. The access is protected by password.
Push P3 to enter in editing mode, P4 and P6 to increase or decrease the selected digit. Push P3 to save the
digit and
pass to the next. Push P1 to cancel the digit or exit the Menu.
5.2.9SYSTEMMENU
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Koper Megatron 40 Instructions For Installation, Use And Maintenance Manual

Category
Stoves
Type
Instructions For Installation, Use And Maintenance Manual

Koper Megatron 40 is a pellet stove designed for home heating. It is equipped with a range of features to make it easy to use, efficient, and safe.

The stove has a large hopper that can hold up to 30 kg of pellets, so you don't have to refill it often. It also has a programmable thermostat that allows you to set the desired temperature for your home, and it will automatically adjust the burn rate to maintain that temperature.

The stove is also very efficient, with a burn efficiency of up to 90%. This means that it will use less fuel to heat your home, saving you money on your energy bills.