Dometic FL1600, FL2200 Installation guide

Type
Installation guide

This manual is also suitable for

1
A
A
B
B
AB
C
BA
1.
2.
1
1.
2.
2.
1.
1.
1.
6
8
9
10
7
4
5
2
3
11
max.
90 mm
400 mm
700 mm
400 mm
700 mm
400 mm
Freshlight
1
2
6
7
8
3
4
5
9
a
0
FreshLight-I-16s.book Seite 1 Mittwoch, 8. März 2017 9:50 21
2
Dometic WAECO International GmbH
Hollefeldstrasse 63
D-48282 Emsdetten
dometic.com
A
2,5 Nm
1.
2.
3.
1
2
h
1
1
2
1
2
1
3
4
2
1.
2.
4
65
3
d
c
g
h
f
e
b
i
4445101813 ST0183 825 02 01-87 03/2017
FreshLight-I-16s.book Seite 2 Mittwoch, 8. März 2017 9:50 21
FL1600, FL2200
Air conditioning roof unit
Installation Manual. . . . . . . . . . . . . . . . . . . . . 3
Dachklimaanlage
Montageanleitung. . . . . . . . . . . . . . . . . . . .22
Climatiseur de toit
Instructions de montage . . . . . . . . . . . . . . .42
Aire acondicionado de techo
Instrucciones de montaje . . . . . . . . . . . . . . 61
Ar condicionado para tejadilho
Instruções de montagem . . . . . . . . . . . . . . 81
Climatizzatore a tetto
Indicazioni di montaggio . . . . . . . . . . . . . 101
Airconditioning voor dakinbouw
Montagehandleiding . . . . . . . . . . . . . . . .120
Klimaanlæg til tagmontering
Monteringsvejledning. . . . . . . . . . . . . . . .139
Takmonterad klimatanläggning
Monteringsanvisning. . . . . . . . . . . . . . . . .158
Takmontert klimaanlegg
Monteringsanvisning. . . . . . . . . . . . . . . . . 176
Kattooilmastointilaitteisto
Asennusohje . . . . . . . . . . . . . . . . . . . . . . . 194
Накрышный кондиционер
Инструкция по монтажу. . . . . . . . . . . . . . 212
Klimatyzator dachowy
Instrukcja montażu . . . . . . . . . . . . . . . . . . 233
Strešné klimatizačné zariadenie
Návod na montáž . . . . . . . . . . . . . . . . . . . 252
Střešní klimatizace
Návod k montáži . . . . . . . . . . . . . . . . . . . . 271
Tető klíma-ber e nde zés
Szerelési útmutató . . . . . . . . . . . . . . . . . . 289
EN
DE
FR
ES
PT
IT
NL
DA
SV
NO
FI
RU
PL
SK
CS
HU
AIR CONDITIONERS
FRESHLIGHT
FreshLight-I-16s.book Seite 1 Mittwoch, 8. März 2017 8:55 20
FreshLight-I-16s.book Seite 2 Mittwoch, 8. März 2017 8:55 20
EN
FreshLight
3
Please read this instruction manual carefully before installation and first
use, and store it in a safe place. If you pass on the product to another
person, hand over this instruction manual along with it.
Table of contents
1 Explanation of symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2 Safety and installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3 Target group for this instruction manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
4 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
5 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
6 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
7 Labels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
8 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
9 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
10 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
11 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
FreshLight-I-16s.book Seite 3 Mittwoch, 8. März 2017 8:55 20
EN
Explanation of symbols FreshLight
4
1 Explanation of symbols
D
!
!
A
I
2 Safety and installation instructions
Please observe the prescribed safety instructions and stipulations from the
vehicle manufacturer and service workshops.
The manufacturer accepts no liability for damage in the following cases:
Faulty assembly or connection
Damage to the product resulting from mechanical influences and excess voltage
Alterations to the product without express permission from the manufacturer
Use for purposes other than those described in the operating manual
Note the following basic safety information when using electrical devices to protect
against:
Electric shock
Fire hazards
Injury
DANGER!
Safety instruction: Failure to observe this instruction will cause fatal or
serious injury.
WARNING!
Safety instruction: Failure to observe this instruction can cause fatal or
serious injury.
CAUTION!
Safety instruction: Failure to observe this instruction can lead to injury.
NOTICE!
Failure to observe this instruction can cause material damage and impair
the function of the product.
NOTE
Supplementary information for operating the product.
FreshLight-I-16s.book Seite 4 Mittwoch, 8. März 2017 8:55 20
EN
FreshLight Safety and installation instructions
5
2.1 Handling the device
!
WARNING!
Installation and repair of the roof air conditioner may only be carried
out by qualified personnel who are familiar with the risks involved and
the relevant regulations. Inadequate repairs may cause serious
hazards. For repair service, please contact the service centre in your
country (addresses on the back page).
Electrical devices are not toys.
Keep electrical devices out of reach of children or infirm persons. Do
not allow them to use electrical devices without supervision.
Persons (including children) whose physical, sensory or mental
capabilities or whose lack of experience and knowledge prevent them
from using the device safely should not use it without supervision or
instruction by a responsible person.
Do not undo the upper cover of the roof air conditioner in the event of
a fire. Use approved extinguishing agents instead. Do not use water to
extinguish fires.
!
CAUTION!
The roof air conditioner must be installed securely so that it cannot fall
down.
Only operate the roof air conditioner if you are certain that the housing
and the cables are not damaged.
Do not use the roof air conditioner near flammable fluids or in closed
rooms.
Make sure no combustible objects are stored or installed near the air
outlet. A distance of at least 50 cm must be kept.
Do not reach into air outlets or insert any foreign objects in the device.
A
NOTICE!
Only use the device as intended.
The roof air conditioner is not suitable for use in agricultural or
construction vehicles.
Do not make any alterations or conversions to the device.
Never drive through automatic car washes when the roof air
conditioner is mounted.
If faults occur in thes refrigerant circuit, the system must be checked by
a specialist company and repaired properly. The refrigerant must
never be released into the air.
FreshLight-I-16s.book Seite 5 Mittwoch, 8. März 2017 8:55 20
EN
Target group for this instruction manual FreshLight
6
I
NOTE
Please ask your vehicle manufacturer if a technical inspection is
required after fitting an air conditioner and whether the height entered
in the vehicle documents needs to be altered (increased height
210 mm).
2.2 Handling electrical cables
!
WARNING!
The electrical power supply may only be connected by a qualified
electrician (e.g. VDE 0100, Part 721 in Germany).
!
CAUTION!
Attach and lay the cables so that they cannot be tripped over or
damaged.
A
NOTICE!
Use cable ducts to lay cables through walls with sharp edges.
Do not lay loose or bent cables next to electrically conductive
materials (metal).
Do not pull on the cables.
3 Target group for this instruction manual
The instructions in this manual are intended for qualified personnel at workshops
who are familiar with the guidelines and safety precautions to be applied.
FreshLight-I-16s.book Seite 6 Mittwoch, 8. März 2017 8:55 20
EN
FreshLight Scope of delivery
7
4Scope of delivery
5Accessories
Available as accessories (not included in the scope of delivery):
I
No. in fig. 1 Number Description
1 1 Roof air conditioner
2 1 Air outlet unit
3 3 Fastening brackets
4 4 Air filters
52Filter covers
6 4 Seals
7 3 Cable connectors
8 6 Long fastening screws
9 6 Short fastening screws
10 4 Caps
11 1 Remote control
Part designation Reference no.
DC extension kit DC-Kit2 9100300001
DC extension kit DC-Kit3 9100300002
DC extension kit DC-Kit5 9100300073
NOTE
The DC extension kit (accessory) allows the Dometic FreshLight roof air
conditioner to be used while in motion.
FreshLight-I-16s.book Seite 7 Mittwoch, 8. März 2017 8:55 20
EN
Intended use FreshLight
8
6 Intended use
The Dometic roof air conditioner FreshLight with integrated roof window can
condition the interior of campers and caravans with cool or warm air.
The roof air conditioner is not suitable for installation in construction machines, agri-
cultural machines or similar equipment. It will not work properly if exposed to strong
vibrations.
Do not operate the roof air conditioner if the ambient temperature is above 52 °C.
Do not operate the roof air conditioner in the “Heating” air conditioning mode if the
room temperature is above 30 °C.
The heating mode is recommended at ambient temperatures of +2 °C and above.
I
7Labels
Labels are attached to the Dometic FreshLight roof air conditioners. These labels pro-
vide the user and fitter with information on specifications of the device.
NOTE
You can find additional information on roof air conditioners in the oper-
ating manual, such as the technical description or the controls.
FreshLight-I-16s.book Seite 8 Mittwoch, 8. März 2017 8:55 20
EN
FreshLight Installation
9
8 Installation
!
8.1 Note on installation
Read this installation manual completely before installing the roof air conditioner.
The following tips and instructions must be observed while installing the roof air
conditioner:
D
!
A
CAUTION! Beware of injury
The roof air conditioner may only be installed by qualified personnel
from a specialist company. The following information is intended for
technicians who are familiar with the guidelines and safety precautions
to be applied.
DANGER! Danger of electrocution
Disconnect all power supplies when working on the roof air conditioner.
CAUTION! Beware of injury
Improper installation of the roof air conditioner can result in
irreparable damage to the device and put the safety of the user at
risk.
The manufacturer assumes no liability for malfunctions and for the
safety of the roof air conditioner, especially for injury and/or damage
to property, if the roof air conditioner is not fitted in accordance with
these installation instructions.
Always wear the recommended protective clothing (e.g. protective
goggles, gloves).
NOTICE! Beware of damage
Observe the structural engineering of the vehicle and seal of all
openings made when installing the roof air conditioner.
Check whether the roof of the vehicle is able to support the weight
of a person before climbing onto it. Ask the vehicle manufacturer
about the permissible roof loads.
FreshLight-I-16s.book Seite 9 Mittwoch, 8. März 2017 8:55 20
EN
Installation FreshLight
10
Note on transport
Always have someone help you carry the roof air conditioner.
Always lift the roof air conditioner to move it and never drag it over the roof
(fig. 2 A).
Do not use the rear ventilation slots to lift it (fig. 2 B).
Note on installation location
Before installing the roof air conditioner, check whether any vehicle components
could be damaged by the installation of the roof air conditioner (such as lamps,
cupboards, doors).
Before installation, find out (by consulting the manufacturer of the vehicle)
whether the construction is designed for the static weight and the loads of the air
conditioner when the vehicle is in motion. The manufacturer of the roof air
conditioner assumes no liability whatsoever.
The vehicle manufacturer may have already provided points where the opening
for the installation of the roof air conditioner can be made without any risk of
weakening the construction or cutting power cables.
Select a flat and sufficiently level area at the centre of the vehicle roof between
two longitudinal sections for installation.
The roof inclination of the installation surface may not exceed 10°.
The roof air conditioner must be installed above 2 meters.
Make sure no combustible objects are stored or installed near the air outlet.
A distance of at least 50 cm should be kept.
Make sure that there are no objects within the vehicle which could obstruct the
attachment of the air outlet unit or the cooled air from flowing through the
swivelling air distribution nozzles.
For safety reasons, note the location of existing wiring harnesses, wires and other
components within the installation area, in particular those which are not visible,
when installing the roof air conditioner (when drilling or screwing etc.).
FreshLight-I-16s.book Seite 10 Mittwoch, 8. März 2017 8:55 20
EN
FreshLight Installation
11
Note on electrical system
Only a qualified electrician should connect the roof air conditioner to the
electrical power.
Check that the voltage specification on the type plate is the same as that of the
power supply.
If the lighting should also be switched on without a 230 V voltage supply, make
sure that there is a 12 Vg power supply line from the battery to the roof air
conditioner.
Do not lay the 230 V mains cable and the 12/24 Vg cable together in the same
cable duct.
Do not lay cables which are loose or bent next to electrically conductive material
(metal).
Install an all-pole switch with a contact opening width of at least 3 mm on the
installation side.
There are two ways of installing the air conditioner:
Making a new opening (chapter “Making a new opening” on page 11). In this
case the opening must be reinforced by an appropriate frame.
Using the existing roof hatch openings (ventilation hatch) in the vehicle (chapter
“Installing in a roof hatch opening already provided” on page 12).
8.2 Making a new opening
See fig. 3
Select an area at the centre on the roof between two longitudinal supports.
Mark the position and size of the opening using the template included in the
packaging (A and B).
Alternatively, you could create two small openings (C).
See fig. 4
Drill out the corners (A).
Carefully cut out the opening on the roof using a keyhole saw or a similar tool (B).
Make sure no electrical power cables are damaged.
FreshLight-I-16s.book Seite 11 Mittwoch, 8. März 2017 8:55 20
EN
Installation FreshLight
12
See fig. 5
Before installation, check whether the roof hole needs reinforcing.
Remove the foam according to the width of your reinforcing rails (not in scope of
delivery) (A).
Fit the reinforcing rails (B).
8.3 Installing in a roof hatch opening already provided
I
See fig. 6
Remove all screws and fixtures of the existing roof hatch.
Take out the roof hatch.
See fig. 7
Remove the sealant around the opening using a scraper or similar tool.
See fig. 8
A
Seal the screw holes and recesses with a flexible non-hardening butyl sealing
compound (e.g. SikaLastomer-710).
NOTE
Existing roof hatch openings in accordance with fig. 3 are suitable
for installing the roof air conditioner.
Dispose of all waste material, glue, silicone and seals separately.
Observe the disposal guidelines.
The manufacturer only assumes liability for parts included in the
scope of delivery. The validity of the warranty expires if the device is
installed together with third-party parts.
NOTICE!
Observe the sealant manufacturer’s instructions.
FreshLight-I-16s.book Seite 12 Mittwoch, 8. März 2017 8:55 20
EN
FreshLight Installation
13
8.4 Laying the connecting cables
D
The roof air conditioner must be connected to an electric circuit which is able to
supply the required current (see chapter “Technical data” on page 20).
Select the cross-section of the cable corresponding to the length:
Length < 7.5m: 1.5mm²
–Length > 7.5m: 2.5mm²
See fig. 9
Make an opening on one side in order to feed through the electrical power
supply cable.
Feed the 230 Vwcable through the opening into the vehicle interior.
If the lighting should be switched on without the use of a 230 Vwvoltage supply:
Connect the cable with the positive terminal and the negative terminal of the
vehicle battery.
Feed the 12 Vg cable through the opening into the vehicle interior.
8.5 Installing the roof air conditioner
A
See fig. 0
Lift the roof air conditioner onto the roof of the vehicle.
Position the roof air conditioner over the installation opening.
Observe the direction of travel.
DANGER! Danger of electrocution
Make sure there is no voltage at electrically operated components
before carrying out work on them!
NOTICE! Risk of damage
Observe the structural strength of the roof of the vehicle. The roof of the
vehicle must be able to bear the weight of the roof air conditioner. The
roof must not be indented or deformed by the weight of the unit, even
over a longer period of time.
FreshLight-I-16s.book Seite 13 Mittwoch, 8. März 2017 8:55 20
EN
Installation FreshLight
14
Attaching the roof air conditioner
See fig. a
Mount the fastening bracket with the two long fastening screws.
Start with the two fastening brackets on the outside.
See fig. b
A
Tighten the screws using a torque spanner and a fastening torque of 2.5 Nm.
Electrical connection
See fig. c
230 Vw cable
Connect the roof air conditioner with the 230 Vw voltage supply.
Connect the cables (1) to a cable connector (2).
Remote light switch (not included in the scope of delivery)
You can connect the lighting to a remote light switch. This enables you to switch on
the lighting remotely.
To do this, proceed as follows:
Disconnect the 2-pin plug (3) from the socket on the circuit board of the air outlet
unit.
Connect the two cables of the remote light switch to the 2-pin plug (3).
Insert the 2-pin plug (3) into socket on the circuit board.
12 Vg cable
You can connect the lighting to the battery. This enables you to switch on the lighting
even if the 230 Vw voltage supply is not connected.
To do this, proceed as follows:
Disconnect the 2-pin plug (4) from the socket on the main board.
Connect the positive cable (5) with the plug.
Connect the negative cable (6) with the plug.
NOTICE! Risk of damage
Tighten to the specified torque.
FreshLight-I-16s.book Seite 14 Mittwoch, 8. März 2017 8:55 20
EN
FreshLight Installation
15
Connecting the air outlet unit with the roof air conditioner
See fig. d
Remove the premounted filter covers (1).
Remove the premounted air filter (2).
Fitting the seals
See fig. e
Fit the seals (1).
Determine the thickness by referring to the following table:
Connecting the circuit board
See fig. f
Insert the 12-pin plug (1) in the socket (4) on the circuit board of the air outlet unit.
Insert the 2-pin plug (2) in the socket (3) on the circuit board.
Ceiling thickness Seal thickness
25 mm 20 mm
25–30mm 25mm
30–35mm 30mm
35–40mm 35mm
40–45mm 40mm
45–50mm 45mm
50–55mm 50mm
55–60mm 55mm
FreshLight-I-16s.book Seite 15 Mittwoch, 8. März 2017 8:55 20
EN
Installation FreshLight
16
8.6 Installing the air outlet unit
See fig. g
Attach the air outlet unit to the (1) fastening brackets using the short fastening
screws.
Insert the caps (2) in the holes over the fastening screws.
See fig. h
Install the air filter in the specified sequence.
See fig. i
Fit the filter covers.
Enter the new vehicle height and weight in the vehicle documents.
FreshLight-I-16s.book Seite 16 Mittwoch, 8. März 2017 8:55 20
EN
FreshLight Troubleshooting
17
9 Troubleshooting
Problem Cause Remedy
Roof air
conditioner
constantly switches
itself off.
Icing sensor has tripped. Outer temperature is too low or all air
nozzles are closed.
No cooling
capacity
The roof air conditioner is not set to
cooling.
Set the roof air conditioner to
cooling.
The ambient temperature is above 52 °C. The roof air conditioner is only
designed for ambient temperatures of
up to 52 °C.
The temperature set is higher than the
room temperature.
Select a lower temperature.
The ambient temperature is below 16 °C. The roof air conditioner is only
designed for ambient temperatures
above 16 °C.
One of the temperature sensors is
defective.
Contact an authorised workshop.
The vaporiser fan is damaged.
The condenser fan is damaged.
No heating
capacity
The ambient temperature is above 30 °C. Only use the heating function of
the roof air conditioner at
temperatures below 30 °C.
The ambient temperature is below 2 °C. The heating function of the roof air
conditioner is only designed for
ambient temperatures of up to 2 °C.
The temperature set is above 30 °C. Select a lower temperature.
The roof air conditioner is not set to
heating.
Set the roof air conditioning to
heating.
One of the temperature sensors is
defective.
Contact an authorised workshop.
FreshLight-I-16s.book Seite 17 Mittwoch, 8. März 2017 8:55 20
EN
Disposal FreshLight
18
10 Disposal
Regulations for environmental safety and correct disposal
All organisations must apply a set of procedures to identify, evaluate and control the
influence that their activities (manufacturing, products, services, etc.) have on the
environment.
The procedures to be followed to identify significant environmental impact must take
the following factors into account:
use of raw materials and natural resources
atmospheric emissions
discharge of liquids
waste management and recycling
contamination of the soil
Low air output The air intake section is clogged up. Remove any leaves and other dirt
from the ventilation grilles of the
roof air conditioner.
The blower is defective. Contact an authorised workshop.
Water enters the
vehicle
The condensation water drainage
openings are clogged up.
Clean the drainage openings for
condensation water.
The seals are damaged. Contact an authorised workshop.
Roof air
conditioner does
not switch on.
No supply voltage (230 Vw) connected. Check the power supply.
The voltage is too low (under 200 V).
The voltage converter is defective.
Contact an authorised workshop.
One of the temperature sensors is
defective.
The electrical fuse of the power supply is
too low.
Check the electrical fuse of the
power supply.
Roof air
conditioner does
not switch off.
One of the temperature sensors is
defective.
Contact an authorised workshop.
The electrical fuse of the power supply is
too low.
Check the electrical fuse of the
power supply.
Problem Cause Remedy
FreshLight-I-16s.book Seite 18 Mittwoch, 8. März 2017 8:55 20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310

Dometic FL1600, FL2200 Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI