Altronix MAXIMAL3R Datasheet

Category
Power distribution units (PDUs)
Type
Datasheet
Altronix new Maximal3R rack mount access power controller distributes and switches power to access control
systems and accessories. It converts a 115VAC 50/60Hz input into sixteen (16) independently controlled 12VDC
or 24VDC fuse protected outputs. Outputs are activated by an normally open (NO) or normally closed (NC)
dry trigger input from an Access Control System, Card Reader, Keypad,
Push Button, PIR, etc. This unit will route power to a variety of
access control hardware devices including: Mag Locks, Electric
Strikes, Magnetic Door Holders, etc. Outputs will operate in both
Fail-Safe and/or Fail-Secure modes. The FACP Interface enables
Emergency Egress, Alarm Monitoring, or may be used to
trigger other auxiliary devices. The fire alarm disconnect
feature is individually selectable for any or all of the outputs.
Input:
• 115VAC60Hz.,1.9amp.
• Normallyclosed[NC]ornormallyopen[NO]
dry contact inputs (switch selectable).
Outputs:
• 12VDCor24VDC@6amptotaloutputcurrent.
• Sixteen(16)fuseprotectedoutputs.
• MaximumcurrentperACM8R-Moutputis2.5amp.
• IndividuallyselectableMagLock/Strike(Fail-Safe,
Fail-Secure) solid state fuse protected outputs.
• Thermalandshortcircuitprotectionwithautoreset.
Fire Alarm Interface:
• LatchingorNon-Latchingfirealarmresetswitch
individually selectable for each output.
• RemoteresetcapabilityforlatchingFireAlarm
Interface mode.
• FireAlarmdisconnectinputoptions:
a) Normallyopen[NO]ornormallyclosed[NC]
dry contact input.
b) Polarity reversal input from FACP signaling
circuit.
Visual Indicators:
• IndividualOutputStatusLEDslocatedonthe
front panel.
Battery Backup:
• Built-inchargerforsealedleadacidorgeltype
batteries (if batteries are required install
separate enclosure).
• Maximumchargecurrent0.7amp.
• Automaticswitchovertostand-bybattery
when AC fails.
• Zerovoltagedropwhenunitswitchesovertobattery
backup (AC failure condition).
Supervision:
• ACfailsupervision(form“C”contact).
• Lowbatteryandbatterypresencesupervision
(form“C”contact).
Additional Features:
• Removableterminalblockswithlockingscrewflange.
• 3-wirelinecord.
• Illuminatedmasterpowerdisconnectcircuitbreaker
with manual reset.
Rack Dimensions:
3.25”Hx19.125”Wx8.5”D
Shipping Weight (approximate):
- Maximal3R:12.7lbs.
Maximal3R
Rack Mount Access Power Controller
Rev.DSMaximal3R-A19K
Overview
Specifications
Altronix Corp. - 140 58th Street, Brooklyn, NY 11220 • 718-567-8181 • 888-258-7669 • altronix.com
FRONT
3.125"
8.5"
.75"
19.125"
17.625"
- - - +
OUT1
- - - +
OUT2
- - - +
OUT3
- - - +
OUT4
- - - +
OUT5
- - - +
OUT6
- - - +
OUT7
- - - +
2 1
OUT8
- - - +
OUT9
- - - +
OUT10
- - - +
OUT11
- - - +
OUT12
- - - +
OUT13
- - - +
OUT14
- - - +
OUT15
- - - +
OUT16
IN1
IN2
IN3
IN5
IN6
IN7
IN8
IN4
GND
GND
GND
RESET
FACP
GND
2 1
IN14
IN15
IN16
GND
RESET
FACP
GND
GND
IN9
IN10
IN11
IN13
IN12
GND
GND
GND
TOP & BOTTOM
REAR
Maximal3R Rack Chassis Dimensions
3.25”Hx19.125”Wx8.5”D
  • Page 1 1
  • Page 2 2

Altronix MAXIMAL3R Datasheet

Category
Power distribution units (PDUs)
Type
Datasheet

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI