d Symbols
A
C (Alternating
C
D
C (Direct Curre
B
oth AC and DC
R
isk of Electric
p
ossible.
C
aution: risk o
f
nformation.
W
arning: a haz
a
or de
a
C
aution: conditi
meter
o
D
ouble insulatio
n
E
arth
F
use
C
apacitor
D
iode
C
ontinuity
DVM87
0
3
USER MA
N
E
uropean Unio
n
t
al information
h
e device or the
ts lifecycle could
n
it (or batteries)
t
o a specialized
c
u
ld be returned t
o
e
. Respect the lo
c
u
r local waste
d
e
lleman! Please
r
e
rvice. If the de
v
c
t your dealer.
C
urrent)
nt)
shock. A poten
t
f
danger, refer t
a
rdous condition
a
th
on or action tha
t
o
r equipment un
n
(class II-protec
0
N
UAL
n
about this pro
d
package indicat
e
harm the envir
o
as unsorted mu
n
c
ompany for rec
y
o
your distributo
r
c
al environment
a
d
isposal author
i
r
ead the manual
v
ice was damag
e
t
ially hazardous
v
o the user manu
or action that m
t
may result in d
a
der test
tion)
Rev.
0
©Velleman
d
uct
e
s that disposal
o
o
nment. Do not
n
icipal waste; it
y
cling.
r
or to a local
a
l rules.
i
ties.
thoroughly befo
r
e
d in transit, don
'
v
oltage is
al for safety
ay result in inju
r
a
mage to the
0
1
nv
o
f
r
e
'
t
r
y
04.02.2010
3. Sa
f
4. Ov
e
DMMs ar
e
overvolta
g
bursts of
power lin
e
The existi
CAT I
A
e
e
CAT II
A
e
t
e
C
a
CAT III
A
C
m
f
d
o
f
ety Instruct
WARNING: To
a
leads prior to o
p
only use batteri
e
this manual.
Remark: refer
t
For indoor use o
splashing and d
r
Keep the device
Risk of electri
c
measuring live
c
There are no us
e
Refer to an auth
This is an inst
a
instrument. N
e
environment. R
e
e
rvoltage/i
n
e
categorized de
p
g
e that might oc
energy induced i
e
.
ng categories a
c
A
CAT I-rated m
e
e
lectronic circuit
s
e
.g. electronics
c
A
CAT II-rated
m
e
nvironments an
t
he mains by me
e
nvironment, pr
o
C
AT III- or 20m
a
a
ppliances, port
a
A
CAT III-rated
m
C
AT II-environm
e
m
ono- or poly-p
h
f
rom of a CAT IV
d
istribution level
o
vens).
DVM87
0
4
ions
a
void electrical s
p
ening the housi
n
e
s and fuses wit
h
t
o the warning o
n
nly. Keep this d
e
r
ipping liquids.
away from child
c
shock during
o
c
ircuits.
er
-serviceable p
a
orized dealer fo
r
a
llation catego
r
e
ver use this eq
u
e
fer to §4 Over
v
n
stallation c
a
p
ending on the ri
cur at the point
o
n a system, e.g.
c
cording EN 610
1
e
ter is suitable f
o
s
that are not di
r
c
ircuits, control s
i
m
eter is suitable
f
d mono-phase a
p
ans of a plug an
d
o
vided that the c
a
part from a CA
T
a
ble tools…
m
eter is suitable
e
nts, as well as
f
h
ased appliances
-environment, a
n
equipment (fus
e
0
hock always di
s
n
g.
T
o prevent d
a
h
the same ratin
g
n
the battery co
m
e
vice away from
ren and unautho
o
peration. Be v
e
a
rts inside the d
e
r
service and/or
s
r
y CAT II meas
u
u
ipment in a CA
T
v
oltage/install
a
a
tegory
sk and severity
o
o
f test. Transien
t
caused by light
n
1
0-1 are:
o
r measurement
s
r
ectly connected
t
i
gnals…
f
or measuremen
t
p
pliances that a
r
d
circuits in a no
r
ircuit is at least
1
T
IV-environmen
t
for measureme
n
f
or measuremen
t
which are at le
a
n
d for measure
m
e
boxes, lighting
Rev.
0
©Velleman
s
connect the test
a
mage or injury,
g
s as specified in
m
partment [10].
rain, moisture,
rised users.
e
ry careful when
e
vice.
s
pare parts.
u
ring
T
III or CAT IV
a
tion category.
o
f transient
t
s are short-live
d
n
ing strike on a
s
on protected
t
o mains power,
t
s in CAT I-
r
e connected to
r
mal domestic
1
0m apart from
a
t
. E.g. househol
d
n
ts in CAT I- and
t
s on (fixed)
a
st 10m apart
m
ents in or on
circuits, electric
0
1
nv
d
a
d
DVM870 Rev. 01
04.02.2010 ©Velleman nv
5
CAT IV A CAT IV-rated meter is suitable for measuring in CAT I-, CAT II-
and CAT III-environments as well as on the primary supply level.
Note that for all measurements on equipment for which the supply
cables run outdoors (either overhead or underground) a CAT IV
meter must be used.
Warning: this device was designed in accordance with EN 61010-1
installation category CAT II 600V. This implies that certain restrictions in use
apply that are related to voltages and voltage peaks which can occur within
the environment of use.
This device is suitable for measurements up to 600V in CAT II:
measurements in CAT I-environments and mono-phase appliances that
are connected to the mains by means of a plug and circuits in a normal
domestic environment, provided that the circuit is at least 10m apart from
a CAT III- or 20m apart from a CAT IV-environment. E.g. household
appliances, portable tools…
5. General Guidelines
Refer to the Velleman
®
Service and Quality Warranty on the last pages
of this manual.
Familiarise yourself with the functions of the device before actually using
it.
All modifications of the device are forbidden for safety reasons. Damage
caused by user modifications to the device is not covered by the warranty.
Only use the device for its intended purpose. Using the device in an
unauthorised way will void the warranty.
Damage caused by disregard of certain guidelines in this manual is not
covered by the warranty and the dealer will not accept responsibility for
any ensuing defects or problems.
Protect this device from shocks and abuse. Avoid brute force when
operating.
Protect the device against extreme heat (e.g. direct sunlight) and dust.
Do not store or use the devices in places with high humidity or
temperature, places where combustible or explosive gasses reside or near
strong magnetic fields.
Caution: risk of electroshock when measuring voltages > 36VDC, 25VAC,
currents > 10mA, AC power lines with inductance load and AC power lines
with fluctuating power.
Only use the included test leads. When damaged, replace them with test
leads of the same type and with the same specifications.
Always verify that all connections are reliable and safe.
Before measuring, always check the selected range.
Avoid body contact with ground potential (e.g. metallic terminals, output
sockets, lead clamp…) while measuring. Make sure to be electrically
insulated from ground during measurement.
DVM870 Rev. 01
04.02.2010 ©Velleman nv
6
Always use the device within its specified range.
Calibration and repair must be performed by a qualified technician. Refer
to your local dealer.
Never attempt to measure voltages when a current measuring range is
selected.
6. Features
3 1/2 Digit LCD display with automatic polarity indication and settings
information
automatic or manual range selection
data hold function
continuity and diode test
peak hold function
auto-restore fuse (except 10A range)
conform with IEC1010 CAT II (residential branch circuits) 600V
7. Overview
Refer to the illustrations on page 2 of this manual.
1 LCD display, 3 full digits and 1 half (max. range 1999)
2 MAX: hold max value on LCD
3 SELECT: function switch
4 HOLD: lock the current reading
5 RANGE: for manual range selection
Disconnect from live circuit before changing!
6 Rotary switch: to select type of measurement
7 COM: common input terminal
8 10A: input terminal for high currents
9 VmA: input terminal for current <200mA and all other measurements
10 battery compartment
11 screw (4x) to open housing (located under protective cover)
12 location of fuse
13 stand
04.02.2010
8. Us
e
GENERAL
When
t
in aut
o
T
he di
s
a high
e
Do no
t
("Vm
A
only h
a
T
he de
secon
d
AC/DC V
O
Conne
c
the "C
O
Set th
e
positio
range
s
the id
e
When
and D
C
Conne
c
Read t
h
the re
d
Rang
e
200m
V
2V
AC/DC C
U
Conne
c
to the
measu
Set th
e
and us
Open t
test le
a
Read t
h
LCD di
s
e
Risk of electri
c
measuring live
c
t
he range of the
o
-range mode, a
n
s
play shows “OL
e
r range to conti
n
t
measure volta
g
A
" jack [9]) or
1
a
ndle 10A for les
s
vice will go in sl
e
d
s. Press any but
t
O
LTAGE MEASUR
c
t the red test le
a
O
M" jack [7].
e
rotary switch [
6
n. If the voltage
s
witch in the hig
h
e
al resolution is
o
is selected,
C
voltage.
c
t the test leads
t
h
e voltage value
d
lead connectio
n
e
Resolution
V
100µV
1mV
U
RRENT MEASU
R
c
t the red test le
a
"COM" jack [7].
rements betwee
n
e
rotary switch [
6
e the select butt
o
he circuit in whi
c
a
ds to the circuit
h
e current value
s
play.
DVM87
0
7
c
shock during
o
c
ircuits.
measured signal
n
d then select ra
n
when the prese
n
ue measureme
n
g
es > 600 V or c
u
1
0 A ("10A" jack
s
than 15 secon
d
e
ep mode when
n
t
on to re-activat
e
EMENT
a
d to the "Vm
A
6
] in the desired
to be measured
h
est range positi
o
btained.
use the select b
u
t
o the source be
i
on the LCD disp
n
.
Range Reso
l
20V 10
m
200V 10
0
R
EMENT
a
d to the "Vm
A
Connect the red
n
200mA and 10
A
6
] in the desired
o
n [3] to choos
e
c
h the current is
IN SERIES.
and the polarity
0
o
peration. Be v
e
is unknown, sta
n
ge according to
nt range limit is
n
t.
u
rrent higher th
a
[8]). Note that
t
d
s.
n
o activity is det
e
e
.
A
" jack [9] and t
h
ACV or DCV (
is unknown befo
on and then red
u
u
tton [3] to cho
o
i
ng measured.
lay [1] along wi
t
l
ution Range
m
V 600V
0
mV
A
" jack [9] and t
h
lead to the "10
A
A
.
ACA or DCA (
e
between AC an
d
to be measured
of the red lead
c
Rev.
0
©Velleman
e
ry careful when
rt measurement
indicated value.
exceeded. Selec
t
a
n 200mA
t
he meter can
e
cted for ±15
h
e black lead to
, , )
rehand, set the
u
ce gradually un
t
o
se between AC
t
h the polarity o
f
Resolution
1V
h
e black test lea
d
A
" jack [8] for
, , )
d
DC current.
and connect the
c
onnection on th
e
0
1
nv
t
t
il
f
d
e
DVM870 Rev. 01
04.02.2010 ©Velleman nv
8
Range Resolution
Range Resolution Range Resolution
200µA 0.1µA 20mA 10µA 10A 10mA
2mA 1µV 200mA 100µA
RESISTANCE
Connect the red test lead to the "VmA" jack [9] and the black test lead
to the "COM" jack [7] (the red lead has a positive polarity "+").
Set the rotary switch [3] in the "" range position.
Connect the test leads to the resistor to be measured and read the LCD
display.
If the resistance being measured is connected to a circuit, turn off the
power and discharge all capacitors before applying the test probes.
Note:
wait a few seconds for a stable reading when measuring resistors >
1M.
Range Resolution
Range Resolution Range Resolution
200 0.1 20K 10 2M 1k
2k 1 200k 100 20M 10k
DIODE TEST AND AUDIBLE CONTINUITY TEST
Connect the red test lead to "VmA" jack [9] and the black one to the
"COM" jack [7] (the red lead has a positive polarity "+").
Set the rotary switch [6] in the position and use the select button
[3] to choose between diode or continuity test. Do not apply input
voltage at this setting!
For diode tests, connect the red test lead to the anode of the diode to be
tested and the black test lead to the cathode of the diode. The approx.
forward voltage drop of the diode will be displayed. If the connection is
reversed, the display will show “OL”.
For continuity tests, connect the test leads to two points of the circuit to
be tested. If continuity exists, the built-in buzzer will sound.
Notes:
forward DC current: ±0.5mA
backward DC voltage: ±1.5V
open circuit voltage: ±0.5V
buzzer sounds when resistance < 50
TEMPERATURE
Set the rotary switch [6] in the °C/°F position and use the select button
[3] to choose between °C and °F. Do not apply input voltage at this
setting!
Insert the cathode (black pin) in the "COM" jack [7], and the anode (red
pin) in the "VmA" jack [9].
Use the other end of the thermocouple to measure temperatures.
04.02.2010
Do not
9. In
s
When t
h
batteri
e
Alway
s
device
w
T
he ba
t
one scr
Remov
e
as indi
c
same t
y
Reinsta
Do not
r
W
b
r
K
10. Re
p
Alway
s
device
w
Remov
e
housin
g
Remov
e
specifi
Close t
h
T
o test
black t
e
p
o
Bring t
h
is OK; i
Note:
t
change the pro
b
s
talling/repl
a
WARNING: to
a
before opening
t
use batteries an
d
manual.
h
e low battery i
n
e
s.
s
disconnect test
w
ithout batterie
s
t
tery cover is loc
a
ew. Remove the
e
the batteries a
n
c
ated in the batt
e
y
pe (AAA) and s
p
ll the cover and
s
r
echarge alkaline
b
W
ARNING: hand
l
b
attery casing.
D
r
egulations.
K
eep batteries a
w
p
lacing fuse
There are no us
e
Refer to an auth
s
disconnect test
w
ithout the fuse
e
the protective
c
g
.
e
the blown fuse
cations (
fuse: 5
x
h
e battery comp
a
the fuse, conne
c
e
st lead to the "
1
o
sition and use t
h
h
e tips of the tes
t
f not the fuse is
t
he 200mA fuse i
DVM87
0
9
b
e, as this will in
f
a
cing batter
i
a
void electrical s
h
t
he housing. To
p
d
fuses with the
n
dication (
)
a
p
leads when repl
s
installed.
a
ted on the bac
k
screw and open
n
d insert two ne
w
e
ry holder. Only
u
p
ecifications; do
s
ecure it with th
e
b
atteries and do n
l
e batteries wit
h
D
ispose of batter
w
ay from childr
e
er
-serviceable p
a
orized dealer fo
r
leads when repl
installed.
c
over and releas
e
[12] and insert
x
20mm F10A 250
V
a
rtment and repl
c
t the red test le
a
1
0A" jack [8]. S
e
h
e select button
t
leads together;
faulty.
s a resettable fu
0
f
luence measuri
n
i
es
h
ock always re
m
p
revent damage
o
same ratings as
p
pears, replace
t
acing the batter
y
k
of the device a
n
the battery com
w
batteries follo
w
u
se new alkaline
not use recharg
e
screw.
ot throw in fire as
h
care, observe
w
ies in accordan
c
e
n.
a
rts inside the d
e
r
service and/or
s
acing the fuse.
D
e
the 4 screws [
1
a new fuse wit
h
V
).
ace the protecti
v
a
d to the "VmA
e
t the rotary swi
t
[3] to choose c
o
when the mete
r
se that can not
b
Rev.
0
©Velleman
n
g accuracy.
m
ove test leads
o
r injury, only
specified in this
t
he internal
y
. Do not us the
n
d is closed with
partment.
w
ing the polarity
batteries of the
eable batteries.
they may explod
e
w
arnings on
c
e with local
e
vice.
s
pare parts.
D
o not use the
1
1] to open the
h
the same
v
e cover.
" jack [9] and t
h
t
ch [6] in the
o
ntinuity test.
r
buzzes, the fus
e
b
e replaced.
0
1
nv
e
.
h
e
e
DVM870 Rev. 01
04.02.2010 ©Velleman nv
10
11. Troubleshooting
No display
check whether power is on
replace battery
check fuse
appears
replace battery
OL appears
select appropriate range
make sure measured value is within limits
impossible value replace battery
12. Technical specifications
DC voltage 0.2/2/20/200/600V
basic accuracy
±(0.5% of rdg + 4 digits)
±(1.0% of rdg + 4 digits) for 600V range
input impedance > 10M
maximum input 600V
AC voltage 0.2/2/20/200/600V
basic accuracy
±(0.8% of rdg + 6 digits)
±(1.5% of rdg + 20 digits) for 0.2V range
input impedance > 10M
frequency range 50-200Hz
maximum input 600V
DC current
200µ/2m/20m/200m/10A
(max. line voltage 230V)
basic accuracy
±(1.0% of rdg + 10 digits)
±(1.2% of rdg + 10 digits) for 10A range
overload protection 0.2A (10A for 10A range)
AC current
200µ/2m/20m/200m/10A
(max. line voltage 230V)
basic accuracy
±(1.5% of rdg +10 digits)
±(2.5% of rdg + 15 digits) for 10A range
overload protection 0.2A (10A for 10A range)
resistance 200/2k/20k/200k/2M/20M
basic accuracy
±(0.8% of rdg + 5 digits) for 200ohm range
±(0.8% of rdg + 4 digits) for 2K~2Mohm range
±(1.2% of rdg + 10 digits) for 20Mohm range
overload protection 250V
temperature -55°C to 1000°C
04.02.2010
basic
maximu
m
LCD displ
a
power su
p
dimensio
n
weight (
w
Use this
be held
r
(incorre
c
and the
l
www.ve
l
change
w
© COPY
R
This ma
n
by Velle
m
be copied
otherwis
e
1. Inl
e
Aan alle
Belangri
j
brengen.
Hebt u v
r
betreffe
n
Dank u v
o
in gebrui
k
installeer
accuracy
m
display
a
y size
p
ply
n
s
w
ith battery)
device with or
i
r
esponsible in
t
c
t) use of this
d
l
atest version
o
l
leman.eu. The
w
ithout prior n
o
R
IGHT NOTICE
n
ual is copyrig
h
m
an nv. All worl
, reproduced, tr
a
e
without the pri
o
GEBR
U
e
iding
ingezetenen v
a
j
ke milieu-info
r
Dit symbool op
h
na zijn levenscy
c
toebrengen aan
batterijen) niet
b
een gespecialis
e
dit toestel naar
u
Respecteer de p
l
r
agen, contact
e
n
de de verwijd
e
o
or uw aankoop!
k
neemt. Werd h
e
het dan niet en
r
DVM87
0
11
< 400°C ±(1.0
%
> 400°C ±(1.5
%
1999
19 x 48 mm
2x AAA (incl.)
70 x 145 x 30
m
± 186g
i
ginal accessor
i
t
he event of da
m
d
evice. For mo
r
o
f this user ma
n
information in
o
tice.
h
ted. The copy
r
dwide rights res
e
a
nslated or redu
c
o
r written consen
U
IKERSHA
a
n de Europes
e
r
matie betreff
e
h
et toestel of de
c
lus wordt wegg
e
het milieu. Gooi
b
ij het gewone h
e
erd bedrijf terec
u
w verdeler of n
a
l
aatselijke milieu
e
er dan de pla
a
e
ring.
Lees deze handl
e
t toestel besch
a
r
aadpleeg uw de
0
%
of rdg + 5 dig
%
of rdg + 15 di
g
m
m
i
es only. Velle
m
m
age or injury
r
e info concern
i
n
ual, please vi
s
this manual is
r
ight to this ma
e
rved. No part o
f
c
ed to any electr
o
t of the copyrig
h
NDLEIDI
N
e
Unie
e
nde dit produc
t
verpakking geef
t
e
worpen, dit toe
s
dit toestel (en e
v
uishoudelijke af
v
htkomen voor r
e
a
ar een lokaal re
wetgeving.
a
tselijke autori
t
eiding grondig v
o
a
digd tijdens het
aler.
Rev.
0
©Velleman
its)
g
its)
m
an nv cannot
resulted from
i
ng this produc
t
s
it our website
subject to
nual is owned
f
this manual ma
o
nic medium or
h
t holder.
N
G
t
t
aan dat, als he
t
s
tel schade kan
v
entuele
v
al; het moet bij
e
cyclage. U moet
cyclagepunt
t
eiten
o
or u het toestel
transport,
0
1
nv
t
y
t
Velleman® Service and Quality Warranty
Velleman® has over 35 years of experience in
the electronics world and distributes its
products in more than 85 countries.
All our products fulfil strict quality
requirements and legal stipulations in the EU.
In order to ensure the quality, our products
regularly go through an extra quality check,
both by an internal quality department and by
specialized external organisations. If, all
precautionary measures notwithstanding,
problems should occur, please make appeal to
our warranty (see guarantee conditions).
General Warranty Conditions Concerning
Consumer Products (for EU):
• All consumer products are subject to a 24-
month warranty on production flaws and
defective material as from the original date of
purchase.
• Velleman® can decide to replace an article
with an equivalent article, or to refund the
retail value totally or partially when the
complaint is valid and a free repair or
replacement of the article is impossible, or if
the expenses are out of proportion.
You will be delivered a replacing article or a
refund at the value of 100% of the purchase
price in case of a flaw occurred in the first year
after the date of purchase and delivery, or a
replacing article at 50% of the purchase price
or a refund at the value of 50% of the retail
value in case of a flaw occurred in the second
year after the date of purchase and delivery.
• Not covered by warranty:
- all direct or indirect damage caused after
delivery to the article (e.g. by oxidation,
shocks, falls, dust, dirt, humidity...), and by
the article, as well as its contents (e.g. data
loss), compensation for loss of profits;
- frequently replaced consumable goods, parts
or accessories such as batteries, lamps, rubber
parts, drive belts... (unlimited list);
- flaws resulting from fire, water damage,
lightning, accident, natural disaster, etc. …;
- flaws caused deliberately, negligently or
resulting from improper handling, negligent
maintenance, abusive use or use contrary to
the manufacturer’s instructions;
- damage caused by a commercial, professional
or collective use of the article (the warranty
validity will be reduced to six (6) months when
the article is used professionally);
- damage resulting from an inappropriate
packing and shipping of the article;
- all damage caused by modification, repair or
alteration performed by a third party without
written permission by Velleman®.
• Articles to be repaired must be delivered to
your Velleman® dealer, solidly packed
(preferably in the original packaging), and be
completed with the original receipt of purchase
and a clear flaw description.
• Hint: In order to save on cost and time,
please reread the manual and check if the flaw
is caused by obvious causes prior to presenting
the article for repair. Note that returning a
non-defective article can also involve handling
costs.
• Repairs occurring after warranty expiration
are subject to shipping costs.
• The above conditions are without prejudice to
all commercial warranties.
The above enumeration is subject to
modification according to the article (see
article’s manual).
Velleman® service- en kwaliteitsgarantie
Velleman® heeft ruim 35 jaar ervaring in de
elektronicawereld en verdeelt in meer dan 85
landen.
Al onze producten beantwoorden aan strikte
kwaliteitseisen en aan de wettelijke bepalingen
geldig in de EU. Om de kwaliteit te
waarborgen,
ondergaan onze producten op regelmatige
tijdstippen een extra kwaliteitscontrole, zowel
door onze eigen kwaliteitsafdeling als door
externe gespecialiseerde organisaties. Mocht er
ondanks deze voorzorgen toch een probleem
optreden, dan kunt u steeds een beroep doen
op onze waarborg (zie waarborgvoorwaarden).
Algemene waarborgvoorwaarden
consumentengoederen (voor Europese
Unie):
• Op alle consumentengoederen geldt een
garantieperiode van 24 maanden op productie-
en materiaalfouten en dit vanaf de
oorspronkelijke aankoopdatum.
• Indien de klacht gegrond is en een gratis
reparatie of vervanging van een artikel
onmogelijk is of indien de kosten hiervoor
buiten verhouding zijn, kan Velleman®
beslissen het desbetreffende artikel te
vervangen door een gelijkwaardig artikel of de
aankoopsom van het artikel gedeeltelijk of
volledig terug te betalen. In dat geval krijgt u
een vervangend product of terugbetaling ter
waarde van 100% van de aankoopsom bij
ontdekking van een gebrek tot één jaar na
aankoop en levering, of een vervangend
product tegen 50% van de kostprijs of
terugbetaling van 50 % bij ontdekking na één
jaar tot 2 jaar.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50

Velleman DVM870 User manual

Category
Multimeters
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI