ā¢Operators of the above mentioned applications, which contain fluorinated greenhouse gases, shall, using all
measures which are technically feasible and do not entail disproportionate costs:
a. Prevent leakage of these gases and as soon as possible repair any detected leakage.
b. Ensure that they are checked for leakage by certified personnel.
c. Ensure proper recovery of flourinated greenhouse gases by certified personnel.
d. In case of applications containing 5 tons CO2 equivalent, i.e. 2.4 kg of R410A (10 tons in case of
hermetically sealed system) or more of F- gases: certified personnel and Companies (according to Reg.
303/2008) provides regular leak testing (according to Reg. 1516/2007 and Reg. 1497/2007) and maintain
records of maintenance activities in a dedicated log book.
e. Recovery for the purpose of recycling, reclamation or destruction of the fluorinated greenhouse gases,
pursuant to Art. 8 of the Regulation shall take place before the final disposal of that equipment and, when
appropriate, during its servicing and maintenance.
ā¢Operator, according to Regulation Article 2, point 8, means the natural or legal person exercising actual power
over the technical functioning of products and equipment covered by this Regulation. The State may, in defined,
specific situations, designate the owner as being responsible for the operatorās obligations. Where large
installations are involved, service companies are contracted to carry out maintenance or servicing. In these
cases, the determination of the operator depends on the contractual and practical arrangements between the
parties.
ā¢Direct methods of leakage checking approved by the manufacturer (Reg. 1516/2007 and Reg. 1497/2007).
a. Gas detection device adapted to the refrigerant in the system; the sensitive of portable gas detection
devices (as a direct test method) shall be at least five grams per year.
b. Proprietary bubble solutions / soapsuds.
ā¢Additional information located into a dedicated label of unit (Reg. 1494/2007)
a. Where fluorinated greenhouse gas is foreseen to be added to the equipment outside of the manufacturing
site at the point of installation, a dedicated label accommodates notation of both the quantity (kg) pre-
charged in the manufacturing plant and of the quantity charged at the installation site as well as the
resulting total quantity of f-gas as a combination of the above mentioned quantities, in a manner which
conforms to the legibility and indelibility.
Our split units are usually not pre-charged on factory, in this case the total quantity of refrigerant charged
in the unit has to be written in the relevant label, during the commissioning operation at the installation
site.
b. Our packaged units (not split) operating with f-gas are usually full charged on factory and the total amount
of refrigerant charge is already reported on the label. In this case, the label has no need of further written
information.
c. In generally, the above mentioned information has been located in the main nameplate of relevant unit.
d. For equipment with double refrigeration circuits, in regards to differentiates requirements on the basis of
the quantity of f-gas contained, the required information about refrigerant charge quantities has to be
listed separately for each individual circuit.
e. For equipment with separate indoor and outdoor sections connected by refrigerant piping, the label
information will be on that part of the equipment which is initially charged with the refrigerant. In case of a
split system (separate indoor and outdoor sections) without a factory pre-charge of refrigerant, the
mandatory label information will be on that part of the product or equipment which contains the most
suitable service points for charging or recovering the fluorinated greenhouse gas(es).
ā¢Safety data sheets of f-gases used in the products are available on demand.
1 Important Safety Instructions
2
Proprietary and Confidential Ā©2023 Vertiv Group Corp.
Vertivā¢ LiebertĀ® CRV CRD25 and CRD35 User Manual