INSTEON Remote Control Plug-in On/Off Module Owner's manual

Category
Remote power controllers
Type
Owner's manual
®
INSTEON On/Off Module 2635-222
Owner’s Manual
®
INSTEON On/Off Module 2635-222
Owner’s Manual
Contents
Getting Started
INSTEON On/Off Module 4
Device Overview
Buttons
Installation
Leave Your Appliance On
INSTEON Links
Understanding Linking 6
Links are One-Way
Links Remember a Device’s State
Controllers
Responders
Controller-Only 7
Responder-Only
Grouping Devices
Use Cross Linking
Linking to the INSTEON Hub 8
Linking with a Single-Button Controller 9
Linking with a Multi-Button Controller 10
Multi-Linking or Making a Scene 11
Unlinking from a Single-Button Controller 12
Unlinking from a Multi-Button Controller 13
Multi-Unlinking or Removing a Scene 14
Local Programming
About Local Programming 16
Local Programming
Navigation
Local Programming Features
Local Programming Flow Chart 17
Software-Only Features
Beep on Button Press 19
Disable Local Programming
Blink on Trafc
Error Blink
Appendix
Specications 22
Troubleshooting 25
Certications and Warnings 27
Product Warranty 28
3
Everything you need to quickly get up and running.
Getting Started
Everything you need to quickly get up and running.
Getting Started
4
Leave Your Appliance OnInstallation
ButtonsDevice Overview
INSTEON On/Off Module
Set Button
On
Off
Status LEDOn
Off
®
Plug your appliance into the bottom of the
On/Off Module and plug the On/Off Module
into an unswitched wall outlet.
Tap to turn off
For dimmable responders:
Double-tap to turn off instantly
Press and hold to dim
Tap to turn on
For dimmable responders:
Double-tap to turn on instantly
Press and hold to brighten
See sections on Basic Linking and
Programming Wheel for set button
functions
®
If your appliance’s switch is OFF, the On/Off
Module will be unable to remotely turn ON
your appliance.
ON
5
INSTEON devices can stand alone and function as a local switch or
dimmer, but their real power comes when they are connected together to
form a control system. Most INSTEON devices can control one another
and be the recipient of control. The process of associating multiple
INSTEON devices to one another is called Linking.
INSTEON Links
INSTEON devices can stand alone and function as a local switch or
dimmer, but their real power comes when they are connected together to
form a control system. Most INSTEON devices can control one another
and be the recipient of control. The process of associating multiple
INSTEON devices to one another is called Linking.
INSTEON Links
6
When linking INSTEON devices, the links that
are created are one-way.
The current state of the controlled device is
stored in the link: on, off or dimmed.
Switch A will turn Switch B on and off but
Switch B cannot turn Switch A on or off.
The switch will turn on the Lamp Dimmer to
75% brightness.
A SwitchB Lamp Dimmer
NEW
X
NEW
X
®
75%
d
f
h
a
c
e
g
b
INSTEON devices that can turn other devices
on or off are called controllers.
Sensors, Switches, Keypads and the
Hub are common controllers.
NEW
X
®
INSTEON devices that receive the command of a
controller are called responders.
Switches, Keypads, Plug-In Modules and
In-Line Modules are common responders.
NEW
X
®
RespondersControllers
Links Remember a Device’s StateLinks are One-Way
Understanding Linking
®
®
Neutral
On
Off
Set
N
N
Load L1
Line L
7
Controller-Only
Some devices like sensors can only control
other devices.
The Motion Sensor will turn on the Switch
but the switch cannot control the Motion
Sensor.
Motion Sensor
NEW
X
®
X
Responder-Only
Some devices cannot control other devices;
these devices only receive INSTEON commands.
Some devices can only link as
responders to devices and scenes.
LED Bulb Dimmer SwitchDimmer Switch
NEW
X
X
Understanding Linking
Grouping Devices Use Cross Linking
You may want to group together two
devices, for example, in a virtual-three way
conguration. For INSTEON, this is called
Cross Linking.
To Cross Link, simply turn on the devices and
perform the linking process twice, once in
each direction.
To group Switch A and B so that they each
control one another and the connected
load, Cross Linking is necessary.
Link Switch A to Switch B and repeat to link
Switch B to Switch A.
NEW
X
NEW
X
A AB BLoad
8
Linking to the INSTEON Hub
1
4
From Rooms, navigate to All Devices.
When prompted, press and hold the
set button on your On/Off Module
until the device double-beeps.
®
Rooms
All Devices Check-In Favorites
Bathroom Bedroom Hallway
Kitchen Living Room Outside
72º
Add Device
Plug-In Module Wired In
LED Bulb Thermostat
3
Select Plug-In Module form the list of
devices.
2
Tap the Add button.
All Devices
Back Door Bathroom Bedroom
Font Door Garage Door Garage Light
Motion Sensor Outside Lights
72º
Add
9
Linking with a Single-Button Controller
2
Make sure the On/Off Module is
On and then press and hold the
On/Off Module’s set button until
the device double-beeps.
Your INSTEON controller will now
control your On/Off Module.
1
On your INSTEON controller, press
and hold the set button until the
device beeps.
®
®
NEW
X
10
A
B
Linking with a Multi-Button Controller
2
Make sure the On/Off Module is
On and then press and hold the
On/Off Module’s set button until
the device double-beeps.
1
On your INSTEON controller, tap
the desired control button and
then press and hold the set button
until the device beeps.
®
®
Your INSTEON controller will now
control your On/Off Module.
NEW
X
11
Multi-Linking or Making a Scene
2
3 4
Adjust your scene members to
their desired state: on, off, or
brightness level if dimming.
Lamp 1
Lamp 3
Lamp 2
Appliance
One at a time, press and hold the
set button on each scene member
until it double-beeps.
Tap the set button on your
INSTEON controller to nish
building your scene.
1
On your INSTEON controller, press
and hold the set button until the
device beeps, then tap the set
button.
50% 72%
30%
ON
®
Your INSTEON controller will
now control your scene.
NEW
X
A
B
12
Unlinking from a Single-Button Controller
1
On your INSTEON controller, press
and hold the set button until the
device beeps.
2
Press and hold the set button
again until the device beeps.
3
Press and hold the On/Off
Module’s set button until the
device double-beeps.
®
®
Your INSTEON controller will no
longer control your On/Off Module.
NEW
X
X
13
A
B
1
On your INSTEON controller, tap
the desired control button and
then press and hold the set button
until the device beeps.
Unlinking from a Multi-Button Controller
2
Press and hold the set button
again until the device beeps.
3
Press and hold the On/Off
Module’s set button until the
device double-beeps.
®
®
Your INSTEON controller will no
longer control your On/Off Module.
NEW
X
X
14
Multi-Unlinking or Removing a Scene
2
3
One at a time, press and hold the
set button on each scene member
until it double-beeps.
Tap the set button on your
INSTEON controller to exit Multi-
Unlinking mode.
1
On your INSTEON controller, press
and hold the set button until the
device beeps. Press and hold the
set button again, then tap the set
button.
®
NEW
X
A
B
C
®
®
®
Your INSTEON controller will no longer
control your INSTEON responders.
X
15
Use the local programming to set local on-level, ramp rates and even
perform a factory reset.
Local Programming
Use local programming to set local on-level, ramp rates and even perform
a factory reset.
Local Programming
16
About Local Programming
Local Programming Features
Linking Mode Readies the module for linking to another INSTEON module. As linking is directional, the rst device
placed into linking mode will become the controller in the controller/responder relationship. The second
device will become the responder. The device automatically exits linking mode after a link has been made
with another INSTEON device or four minutes have elapsed without linking.
Multi-Linking
Mode
Readies the module for linking to multiple INSTEON modules. The module will remain in linking mode
for 4 minutes or until the module’s set button is tapped. This mode is very usefully for manually creating
scenes.
Unlinking
Mode
Allows the removal of links from the INSTEON module. The device will automatically exit unlinking mode
after a link has been removed from another INSTEON device or four minutes have elapsed without linking.
Multi-
Unlinking
Mode
Allows the removal of multiple links from the INSTEON module. The device will stay in unlinking mode for
4 minutes or until the device’s set button is tapped.
LED
Brightness
Allows adjusting the brightness level of the module’s status LED.
RF Beacon Places the module in a mode that broadcasts a signal over INSTEON RF. Any devices beeping or
displaying a blinking LED are within range of the module’s RF signal.
Factory
Reset
Erases any user-customized programming from the device including all INSTEON device links, scenes,
ramp rate, on-level, etc. A factory reset cannot be undone.
To move right, press and
hold the set button
To move down, tap the set
button
Status LED blinks green
Status LED double-blinks
green
Status LED blinks red
Status LED double-blinks
red
The Programming Wheel is a visual
representation of the device’s settings. Many
device features can be congured using
the Programming Wheel. Some devices
have more options than others but the
programming wheel presents even the most
complicated devices with a straightforward,
navigable path.
NavigationLocal Programming
NEW
X
17
Local Programming Flow Chart
®
Unlinking
Mode
Multi-
Unlinking
Mode
Select
Linking Mode
RF Beacon RF Beacon
Toggle
Multi-Linking
Mode
Select
LED
Brightness
Select
LED
Brightness
Adjust
Factory Reset
Select
Press
Tap
Tap
Tap
Tap Tap
Press Press
Press PressPressPress
Press
Press
TapTapTap
Tap
Tap
CancelExitExit
Cancel
Reset
SaveExitExit
Toggle
Cancel
Press
18
Most INSTEON devices contain features that can only be enabled,
disabled or modied using INSTEON control software such as HouseLinc
and an INSTEON PowerLine Modem or the INSTEON Hub.
Software-Only Features
Most INSTEON devices contain features that can only be enabled,
disabled or modied using INSTEON control software such as HouseLinc
and an INSTEON PowerLine Modem or the INSTEON Hub.
Software-Only Features
19
Software-Only Features
Beep on Button Press Disable Local Programming
Blink on Trafc Error Blink
The On/Off Module will beep every time one
of its buttons are tapped. By default, this
feature is disabled.
Prevents changing any settings using the
set button or tap-and-hold programming. By
default, this feature is disabled.
The On/Off Module LED will blink if it detects
INSTEON communication. By default, this
feature is disabled.
The On/Off Module LED will blink red once if
one or more responders do not acknowledge
a message and will blink green once if all
responders successfully acknowledge a
message. By default, this feature is enabled.
®
®® ®
®
X
X
20
Everything else you might need to know about your INSTEON product.
Appendix
Everything else you might need to know about your INSTEON product.
Appendix
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22