Light Management Touch sensor module AC/DC 24 V
Ref.-no.: 32.. TSM
3. Installation
• Touch sensor module for switch programs FDDesign (type A:
height of frame 6 mm) or LSDesign (type B: height of frame 11
mm). Inscription on supporting frame: „Typ A“ or „Typ B“.
• Fit supporting ring (1) in correct position on a flushmounting box
(DIN 49073) (observe the „TOP“ mark, „Typ A“ or „Typ B“ in front).
Use the screws supplied with the mounting box.
• Place the decorative frame (2) on the supporting ring.
• Connect the touch sensor module (3) to the 8- channel relay station
and place it on the supporting ring (see table above).
• Fasten the touch sensor module with the plastic screws supplied (4)
on the supporting ring. The screws are intended as a protection
against removal or theft. Tighten the plastic screws only lightly !.
• Fit the covers (5): Place the covers one by one on the touch sensor
module. The arrangement of the covers is shown in FIG A. Make
sure the cover fits properly (observe the marking TOP on the
inside) and snap it onto the device by a brief press.
(1)
(2)
(3)
(4)
(5)
3.1. Label covers
The covers with Art. no. FD..90x TSA NA.. can be equipped with labels.
Commercial-grade transparencies can be inscribed with the help of the
JUNG labelling software and inserted as labels into the covers. The
JUNG labelling software is available in the Internet under the following
3