JUNG LS2248 Operating instructions

Type
Operating instructions
Light Management Touch sensor AC/DC 24 V
Ref.-no.: ..2212..,
..2224.., ..2248..
Operating instructions
Touch sensor AC/DC 24 V
1. Safety warnings
Attention! Electrical equipment must be installed and fitted by
qualified electricians only. Failure to observe any of the installation
instructions may cause damage to the device and result in fire or
other hazards.
The sensor is a safety class III device. Connect only SELV circuits of
24 V to the device (no mains potential!).
2. Function
Touch sensors intended for connection to the 8-channel relay station (art.
no. RS8 REG) or other control systems with max. 24 V. One red LED for
each sensor indicates the corresponding status. Connection to the device
is made at the back by means of a terminal block.
Fig. A
Stand: Jan-09 24098200
Light Management Touch sensor AC/DC 24 V
Ref.-no.: ..2212..,
..2224.., ..2248..
Fig B
3. Connection
Sensor outputs and LED inputs for
design range A 500: see fig. B
design ranges CD 500, LS 990, Aluminium, Stainless Steel,
Anthracite: see fig. C
Assigned to following
rocker
Sensor
terminal
1-ch. 2-ch. 4-ch.
LED-
terminal
1 1 1
2
1
2 2
3 3 3
4
1
2
4 4
5 5 5
6
3
6 6
7 7 7
8
2
4
8 8
4. Installation
Fit the supporting ring in the correct position on a flush-mounting
box (observe the TOP marking).
Place the decorative frame on the supporting ring.
Connect the touch sensor to the 8-channel relay station (see table
above).
Place the touch sensor on the supporting ring.
Protection against removal is possible.
2
Light Management Touch sensor AC/DC 24 V
Ref.-no.: ..2212..,
..2224.., ..2248..
Fig. C
5. Technical data
Rated voltage sensor: max. AC/DC 24 V SELV
Rated voltage LED: DC 24 V SELV
Current load of sensor: max. 20 mA per sensor
LED current: approx. 1 mA per LED
Connection: 2 x terminal block 9-pole
0.25...0.8 mm2 single wire
Power consumption: max. 0.2 W
(all LEDs on)
Safety class: III
Ambient temperature: -5 °C ... +45 °C
Storage / transport temperature: -25 °C ... +70 °C
Technical specifications subject to change.
3
Light Management Touch sensor AC/DC 24 V
Ref.-no.: ..2212..,
..2224.., ..2248..
6. Acceptance of guarantee
We accept the guarantee in accordance with the corresponding legal
provisions.
Please return the unit postage paid to our central service
department giving a brief description of the fault:
ALBRECHT JUNG GMBH & CO. KG
Service-Center
Kupferstr. 17-19
D-44532 Lünen
Service-Line: +(49) 23 55 . 80 65 51
Telefax: +(49) 23 55 . 80 61 89
General equipment
Service-Line: +(49) 23 55 . 80 65 55
Telefax: +(49) 23 55 . 80 62 55
KNX equipment
Service-Line: +(49) 23 55 . 80 65 56
Telefax: +(49) 23 55 . 80 62 55
The CE-Sign is a free trade sign addressed exclusively to the