cobas t 511

Roche cobas t 511 User guide

  • Hello! I am an AI chatbot trained to assist you with the Roche cobas t 511 User guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
cobas t 511 coagulation analyzer
User Guide Version 1.1
Software version 1.0
Roche Diagnostics
cobas t 511 coagulation analyzer · Software version 1.0 · User Guide · Version 1.1
2
Publication information
Edition notice This publication is intended for operators of the
cobas t 511 coagulation analyzer.
Every effort has been made to ensure that all the
information contained in this publication is correct at the
time of publishing. However, the manufacturer of this
product may need to update the publication information
as output of product surveillance activities, leading to a
new version of this publication.
Where to find information The User Assistance contains all information about the
product, including the following:
• Routine operation
• Maintenance
• Safety
• Troubleshooting information
• A software reference
• Configuration information
• Background information
The Safety Guide contains important safety information.
You must read the Safety Guide before operating the
instrument.
The User Guide focuses on routine operation and
maintenance. The chapters are organized according to
the normal operation workflow.
!
General attention
To avoid serious or fatal injury, ensure that you are
familiar with the system and safety information before you
use the system.
r Pay particular attention to all safety precautions.
r Always follow the instructions in this publication.
r Do not use the instrument in a way that is not
described in this publication.
r Store all publications in a safe and easily retrievable
place.
Publication
version
Software version Revision date Change description
Version 1.0 1.0 March 2017 Initial version
Version 1.1 1.0 July 2017 Updated safety messages
y Revision history
Roche Diagnostics
cobas t 511 coagulation analyzer · Software version 1.0 · User Guide · Version 1.1
3
Training Do not carry out operation tasks or maintenance actions
unless you have received training from Roche
Diagnostics. Leave tasks that are not described in the
user documentation to trained Roche Service
representatives.
Screenshots The screenshots in this publication have been added
exclusively for illustration purposes. Configurable and
variable data, such as tests, results, or path names visible
therein must not be used for laboratory purposes.
Warranty Any customer modification to the system renders the
warranty or service agreement null and void.
For conditions of warranty, contact your local sales
representative or refer to your warranty contract partner.
Always leave software updates to a Roche Service
representative, or perform such updates with their
assistance.
Copyright © 2017, F. Hoffmann-La Roche Ltd. All rights reserved.
License information The software of the cobas t 511 coagulation analyzer is
protected by contract law, copyright law, and
international treaties. The cobas t 511 coagulation
analyzer contains a user license between F. Hoffmann-
La Roche Ltd. and a license holder, and only authorized
users may access the software and use it. Unauthorized
use and distribution may result in civil and criminal
penalties.
Open Source and Commercial Software The cobas t 511 coagulation analyzer may include
components or modules of commercial or open-source
software. For further information on the intellectual
property and other warnings, as well as licenses
pertaining to the software programs included in
cobas t 511 coagulation analyzer refer to the electronic
distribution included with this product.
This open source and commercial software and
cobas t 511 coagulation analyzer as a whole can
constitute a device regulated in accordance with
applicable law. For more detailed information, refer to the
user manual and labeling.
Please note that the respective authorization is no longer
valid according to the corresponding legislation should
any unauthorized changes be made to cobas t 511
coagulation analyzer.
Trademarks The following trademarks are acknowledged:
Roche Diagnostics
cobas t 511 coagulation analyzer · Software version 1.0 · User Guide · Version 1.1
4
COBAS, COBAS T, and LIFE NEEDS ANSWERS are
trademarks of Roche.
All other trademarks are the property of their respective
owners.
Feedback Every effort has been made to ensure that this publication
fulfills the intended use. All feedback on any aspect of
this publication is welcome and is considered during
updates. Contact your Roche representative, should you
have any feedback.
Approvals The cobas t 511 coagulation analyzer meets the
requirements laid down in:
Directive 98/79/EC of the European Parliament and of the
Council of 27 October 1998 on in vitro diagnostic medical
devices.
Directive 2011/65/EU of the European Parliament and of
the Council of 8 June 2011 on the restriction of the use of
certain hazardous substances in electrical and electronic
equipment.
Compliance is provided by means of the Declaration of
Conformity.
The following marks demonstrate compliance:
For in vitro diagnostic use.
Complies with the provisions of the applicable EU
directives.
Issued by Underwriters Laboratories, Inc. (UL) for
Canada and the US.
Issued by CSA Group for Canada and the US.
CUS
Roche Diagnostics
cobas t 511 coagulation analyzer · Software version 1.0 · User Guide · Version 1.1
5
Contact addresses
Roche Diagnostics GmbH
Sandhofer Strasse 116
68305 Mannheim
Germany
Made in Switzerland
Roche Diagnostics
cobas t 511 coagulation analyzer · Software version 1.0 · User Guide · Version 1.1
6
Table of contents 7
Roche Diagnostics
cobas t 511 coagulation analyzer · Software version 1.0 · User Guide · Version 1.1
Table of contents
Publication information 2
Contact addresses 5
Table of contents 7
Intended use 9
Intended users 9
Symbols and abbreviations 9
System description
1 Overview of the system
About the system 17
Measurement principle 18
2 Overview of the hardware
Hardware description 23
System operation
3 Overview of operation
Overview of the main workflow 41
Overview of the software 43
4 Before operation
Checklist: Before operation 57
Starting up the system 58
System alarm concept 61
5 Reagents and consumables
Reagents 67
Reagent handling 72
Other resources 100
6Calibration
About calibration 117
Loading and unloading calibrators 119
List of actions 122
Calibration panels 123
Ordering a calibration 127
Releasing and activating a calibration 129
Performing a standby calibration 132
7 Quality control
About QCs 139
Loading and unloading QCs 142
List of actions 144
QC panels 145
Managing a QC lot 149
Ordering a routine QC 150
Ordering a study QC 151
Reviewing a QC 152
Setting QC target ranges 154
8 Test orders and rack handling
Test orders 159
Rack handling 163
9 Samples and results
List of actions 171
Samples and results panels 172
Handling results 177
Creating and printing a report 179
10 After operation
Checklist: After operation 185
Stopping the system 186
Performing a system restart/reinitialization 191
Shutting down the analyzer for an extended
period 193
11 Maintenance
About maintenance 199
Maintenance actions 200
Additional maintenance 207
Cleaning and decontamination 211
Appendix
12 Specification
List of system specifications 219
Supported material 221
13 Glossary
Index 229
8 Table of contents
Roche Diagnostics
cobas t 511 coagulation analyzer · Software version 1.0 · User Guide · Version 1.1
Roche Diagnostics
cobas t 511 coagulation analyzer · Software version 1.0 · User Guide · Version 1.1
9
Intended use
The cobas t 511 coagulation analyzer is a fully
automated, random continuous-access, software
controlled system for clotting, chromogenic and immuno-
turbidimetric analysis intended for qualitative and
quantitative in vitro coagulation determinations using a
wide variety of coagulation tests, the results of which aid
in the diagnosis of coagulation abnormalities and in
monitoring anticoagulant therapy.
The cobas t 511 coagulation analyzer is a system that
uses human citrated plasma for the determination of
coagulation analytes.
Intended users
The intended users of the cobas t 511 coagulation
analyzer are appropriately trained coagulation
professionals operating the system in a laboratory setting.
Routine operator Primary tasks:
• Running system(s) on a daily basis
• Processing routine and emergency patient samples
• Running calibration & QC (Quality Control)
• Maintenance of instrument and related inventories
Supervisor Responsibilities:
• Reviewing & Validating QC results
• Ensuring accreditation compliance
• Interface with clinicians in case of result query
• Monitor performance efficiency of systems
• Configuration of system
Symbols and abbreviations
Product names Except where the context clearly indicates otherwise, the
following product names and abbreviations are used:
Roche Diagnostics
cobas t 511 coagulation analyzer · Software version 1.0 · User Guide · Version 1.1
10
Symbols used in the publication
Symbols used on product
Product name Abbreviation
Instrument Software for
cobas t 511 coagulation
analyzer
software
cobas t 511 coagulation
analyzer
analyzer
System Cleaner cobas t System Cleaner
cobas Waste Bag solid waste bag
Cuvette COBAS INTEGRA
®
cuvette
y Product names
Symbol Explanation
o List item.
u Related topics containing further information.
q
Tip. Extra information on correct use or useful
hints.
r Start of a task.
I Extra information within a task.
f Result of an action within a task.
c Frequency of a task.
n Duration of a task.
d Materials that are required for a task.
j Prerequisites of a task.
u Topic. Used in cross-references to topics.
p Task. Used in cross-references to tasks.
w
Figure. Used in figure titles and cross-
references to figures.
y
Table. Used in table titles and cross-references
to tables.
y Symbols used in the publication
Symbol Explanation
Global Trade Item Number
Quantity contained in the package.
Indicates that the equipment is suitable for
alternating current only; to identify relevant
terminals.
Serial number
y Symbols used on the instrument
Roche Diagnostics
cobas t 511 coagulation analyzer · Software version 1.0 · User Guide · Version 1.1
11
Catalog number
Manufacturer
Date of manufacture
Caution
Humidity range
Temperature limits
This side up
Fragile, handle with care
Keep dry
Symbol Explanation
y Symbols used on the instrument
Roche Diagnostics
cobas t 511 coagulation analyzer · Software version 1.0 · User Guide · Version 1.1
12
Abbreviations The following abbreviations are used.
Keep away from sunlight
Do not stack
Do not use blades to open.
Symbol Explanation
y Symbols used on the instrument
Abbreviation Definition
ANSI American National Standards
Institute
CISPR Comité International Spécial des
Perturbations Radioélectriques
(International Special Committee
on Radio Interference)
CSA Canadian Standards Association
EC European Community
EN European standard
EU European Union
ID Identification
IEC International Electrical
Commission
IfU Instructions for Use
IVD In vitro diagnostic
n/a Not applicable
RVC Reagent volume check
STAT Short turn around time
UI User interface
UL Underwriters Laboratories Inc.
UPS Uninterruptible power supply
y Abbreviations
Roche Diagnostics
cobas t 511 coagulation analyzer · Software version 1.0 · User Guide · Version 1.1
System description
1 Overview of the system........................................................................................ 15
2 Overview of the hardware................................................................................... 21
1 Overview of the system
Roche Diagnostics
cobas t 511 coagulation analyzer · Software version 1.0 · User Guide · Version 1.1
15
Table of contents
Overview of the system 1
In this chapter
1
About the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Measurement principle . . . . . . . . . . . . . . . . . . . . . . . . . 18
About the measuring principle . . . . . . . . . . . . . . . . 18
About the measurement technology . . . . . . . . . . . 19
1 Overview of the system
Roche Diagnostics
cobas t 511 coagulation analyzer · Software version 1.0 · User Guide · Version 1.1
16
Table of contents
1 Overview of the system
Roche Diagnostics
cobas t 511 coagulation analyzer · Software version 1.0 · User Guide · Version 1.1
Overview of the system 17
About the system
The cobas t 511 coagulation analyzer is a fully
automated, medium throughput system for coagulation
tests. The analyzer is designed for a large array of
qualitative and quantitative in vitro tests and can be
operated 24 hours a day, 7 days a week.
The analyzer consists of the following components:
Component Function
Analyzer unit Contains the incubators and photometers, used for making
measurements; also contains the cuvette handlers, which
move the cuvettes for pipetting, mixing, and measuring.
Control unit Controls the analyzer functions
Cuvette transport unit Transports the cuvettes from the cuvette reservoir to the
analyzer unit.
Fluid unit Manages the system fluids: Water, liquid waste, System
Cleaner, samples, and reagents.
Reagent storage Refrigerates and stores the reagent cassettes.
Sampling unit Includes the rack area slots for placing different types of racks.
From the slots, racks are moved to the barcode reader for
scanning and are then moved to the rack area.
Transfer unit Pipettes samples, reagents, and other fluids from their
containers into cuvettes for mixing so that measurements can
be performed.
y Components of the analyzer
1 Overview of the system
Roche Diagnostics
cobas t 511 coagulation analyzer · Software version 1.0 · User Guide · Version 1.1
18 Measurement principle
Measurement principle
In this section
About the measuring principle (18)
About the measurement technology (19)
About the measuring principle
The analyzer performs optical measurements for clotting
tests, chromogenic tests, and immuno-turbidimetric tests.
The analyzer performs the following tasks:
• Sample and reagents are pipetted into a cuvette and
incubated to ensure that all reaction components are
at the correct temperature.
• The reaction is started by adding a start reagent.
• The photometer measures turbidity or color change
for the respective test.
Clotting test
Plasma is mixed with a reagent or reagents, resulting in
the formation of a fibrin clot that increases the turbidity of
the mixture. The clotting time is calculated based on the
change in turbidity.
Chromogenic test
Plasma is mixed with reagent containing chromogenic
substrate for a specific enzyme. The activation of the
enzyme results in the chromogenic substrate cleaving
and a product changing the color of the reaction mixture
is formed. This change of absorbance is measured and
calculated per unit of time.
Immuno-turbidimetric test
Plasma is mixed with reagent containing latex particles
coated with antibodies for a specific analyte. The latex
particles form complexes with the analyte, resulting in a
change of turbidity of the reaction mixture. This change is
then measured.
-9.548 30.453 70.45350.453
Seconds after reaction
1.089
1.076
1.064
1.051
1.039
1.027
1.014
1.002
Absorbance
Clotting time
-7.657 12.343 32.343 52.343 92.343 112.34372.343
0.030
0.078
0.126
0.173
0.221
0.268
0.316
0.363
Seconds after reaction
Absorbance
Time
abs.
-26.975 23.025 73.025 123.025 223.025 273.025173.025
1.335
1.342
1.350
1.358
1.365
1.373
1.381
1.388
Seconds after reaction
Absorbance
Time
abs.
323.025
1 Overview of the system
Roche Diagnostics
cobas t 511 coagulation analyzer · Software version 1.0 · User Guide · Version 1.1
Overview of the system 19
About the measurement technology
The analyzer takes measurements using photometric
technology.
General photometric characteristics
w Photometer concept, featuring LED source, fiber bundle and cuvette optics
The photometer consists of an integrated light source
featuring the necessary wavelengths, each covered by a
dedicated LED dye. The light is mixed in a quartz rod to
distribute it uniformly over the fibers that transport it to
the measurement cuvettes. Light is then guided by
polymer fibers to the measurement positions in the
coagulation analyzer. The light that passes through the
cuvettes is measured using a photodiode – one for each
cuvette. A reference fiber and diode are included to
monitor light source intensity deviations.
A Light source (LED) C Collimation optics E Photodiode array
B Optical fiber bundle D Cuvette F Reference
A
B
C
D
E
F
1 Overview of the system
Roche Diagnostics
cobas t 511 coagulation analyzer · Software version 1.0 · User Guide · Version 1.1
20 Measurement principle
/