Page 1BDA 542
R
20
250
P S
EJET
16
250
20
250
NA C3 MX-W
NAC3MX-W-TOP powerCON TRUE1 TOP
| ® ®
Approval based:
Rating:
Cable Type:
Cable O.D.:
VDE
EN 60320-1
250 V ac / 16 A
2
H05VV-F3G 1.0 mm , Length max. 2 m
2
H05VV-F3G 1.5 - 2.5 mm
2
H07RN-F3G 1.5 mm
6.0 - 12.0 mm
UL 60320-1
CAN/CSA-C22.2 No. 60320-1
250 V ac / 20 A
SJTOW, SJOOW 3 x 12 AWG
6.0 - 12.0 mm
A APPLICATION INSTRUCTION
40 - 50 mm
20
250
P S
EJET
16
250
20
250
NA C3 MX-W
i
NAC3PX-TOP
NAC3MPX-TOP
NAC3MPX-WOT-TOP
NAC3FPX-TOP
NAC3FPX-WOT-TOP
NAC3FPX-ST-TOP
Power OUT
Power OUT
NAC3FX-W-TOP
(Connector)
NAC3MX-W-TOP
(Plug connector)
NAC3FX-W-TOP
(Connector)
NAC3MX-W-TOP
(Plug connector)
Power IN
APPLIANCE INLET APPLIANCE OUTLET APPLIANCE INLET / OUTLET
uCombination
powerCON TRUE1 TOP line is full backward compatible with the preceding powerCON TRUE1 products.
® ®
CONNECTOR ASSIGNMENT:
Power IN
APPLICATION & ASSEMBLY INSTRUCTION
·The powerCON TRUE1 system is certified as a connector with breaking capacity according IEC 60320,
® ®
VDE 0625.
·It is intended for use as an appliance coupler and interconnection coupler.
·It serves to supply power to an appliance and from an appliance to other equipment.
·To be installed by qualified person only.
Application other equipment:
[0.32"]
8 mm
[0.787”]
20 mm
[0.9”]
PE 23 mm
Separate the
housing from the
bushing (cable
remain in bushing)
B
VDE
EN 60320-1
UL 60320-1
CAN/CSA-C22.2 No. 60320-1
Place chuck over the
cable.
Prepare cable as
shown.
D
C
Recommendation:
Wire Pulling Lubricant - LUB-I/0.95
TM
from 3M
i
AInsert cable into the bushing and housing.
Note: Apply cable pulling
lubricant to cable jacket.
C
[0.32"]
8 mm
[0.787”]
20 mm
[0.9”]
PE 23 mm
B ASSEMBLY INFORMATION
The manufacturer of cord sets and of interconnection cord sets is responsible for the conformity
assessment according to the applicable regulatory documents.
20
250
P S
EJET
16
250
20
250
NAC 3MX-W
5.
20
250
P S
EJET
16
250
20
250
NA C3MX-W
ASSEMBLY INSTRUCTION powerCON TRUE1 TOP - NAC3MX-W-TOP
I ® ®
R
PRESS FIRMLY
Torx size
T8
1.
2.
4.
6.
3.
G
E
F
Important:
Align rubber key
and latch.
Find more details of powerCON TRUE1 TOP on www.neutrik.com.
Insert the wires into the terminals and fasten the
screw with Torx size T8.
Wiring VDE UL
L brown blackÞ
N blue whiteÞ
green / yellow greenÞ
Slide the chuck onto the insert (1) and then both
together into housing (2).
Important: Align the chuck and insert by
positioning the nose into the keyway.
Slide the bushing up the cable and tighten it with
the tool as shown.
Important: Black O-ring to hide to achieve IP
protection (6).
(Tool available: Art. No. HTAC)
Wrench size
13 mm
www.neutrik.com
Draft. Nr.: BDA 542 V4
Update: 2023-06-28
Neutrik AG LI-9494 Schaan
I
Page 2 A brand of the Neutrik Group
Data subject to change without prior notice. 2023 NEUTRIK . NEUTRIK , powerCON are registered trademark of Neutrik AG.
® ®
©
ALL RIGHTS RESERVED.
CAUTION
To ensure protection category, do
not expose the connection to
bending forces (e.g. do not attach
loads to the cable, no free-dangling
cable windings etc.).
FORCE
SAFETY WARNING
For safety and certification reasons the connector must
be replaced in case of any broken parts or excessive
wear and tear.
2.
1.
C FOR DISASSEMBLY
OPEN TWIST LOCK!
1. Press with screw driver to unlock
2. Turn bushing 360°.
3. Repat step 1 + 2 until bushing is unscrewed.
LIECHTENSTEIN
NAC3FX-W
20
250
P S
EJET
NAC3FX-W
D SAFETY INFORMATION
Important:
Push and turn simultaneously.
Torque Value 2.0 Nm
Torque Value 0.7 Nm
  • Page 1 1
  • Page 2 2

Neutrik NAC3MX-W-TOP User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI