Neutrik NAC3MX-W-TOP Operating instructions

Type
Operating instructions

Neutrik NAC3MX-W-TOP is a power connector with breaking capacity, intended for use as an appliance coupler. It serves to supply power to an appliance and from an appliance to other equipment. The device is certified and approved by various organizations, ensuring its quality and safety. It is rated for 250V AC and 16A, with a cable type of H05VV-F3G 1.0 mm2 or H05VV-F3G 1.5 - 2.5 mm2. It features a strain relief with a white chuck and a cable O.D. of 6.0 - 12.0 mm. The device meets UL50E environmental rating and Enclosure Type 4 when mated with specific cord connectors or appliance outlets.

Neutrik NAC3MX-W-TOP is a power connector with breaking capacity, intended for use as an appliance coupler. It serves to supply power to an appliance and from an appliance to other equipment. The device is certified and approved by various organizations, ensuring its quality and safety. It is rated for 250V AC and 16A, with a cable type of H05VV-F3G 1.0 mm2 or H05VV-F3G 1.5 - 2.5 mm2. It features a strain relief with a white chuck and a cable O.D. of 6.0 - 12.0 mm. The device meets UL50E environmental rating and Enclosure Type 4 when mated with specific cord connectors or appliance outlets.

20
250
P S
E
JET
16
250
20
250
NAC3MX-W
C
40 - 50 mm
20
250
P S
E
JET
16
250
20
250
NAC3MX-W
Page 1BDA 542
R
ASSEMBLY INSTRUCTION
Place chuck overthe
the cable.
Prepare cable asthe
shown.
D
Separate the housing
from the bushing (cable
remain in bushing)
B
C
VDE (EN 60320-1/EN60320-2-2) UL (UL 498 / CSA C22.2 No. 182.3)
Recommendation:
Wire Pulling Lubricant - LUB-I/0.95
from 3MTM
i
AInsert cable into the bushing and housing.
Note: “Apply cable pulling
lubricant to cable jacket.”
NAC3 XM -W-TOP power TRU 1CON ETOP
|®
[0.32"]
8 mm
[”]0.787
2mm0
[”]0.9
PE 23 mm
[0.32"]
8 mm
[”]0.787
2mm0
[”]0.9
PE 23 mm
A. APPLICATION INSTRUCTION
B. ASSEMBLY INSTRUCTION
NAC3PX-TOP
NAC3MPX-TOP
NAC3MPX-WOT-TOP
NAC3FPX-TOP
NAC3FPX-WOT-TOP
NAC3FPX-ST-TOP
Power IN
Power OUT
Power OUT
NAC3FX-W-TOP
(Connector)
NAC3MX-W-TOP
(Plug connector)
-w
-w
20
250
P S
E
JET
-w
-w
20
250
P S
E
JET
20
250
P S
E
JET
16
250
20
250
NAC3MX-W
20
250
P S
E
JET
16
250
20
250
NAC3MX-W
NAC3FX-W-TOP
(Connector)
NAC3MX-W-TOP
(Plug connector)
Power IN
CONNECTOR ASSIGNMENT:
APPLIANCE INLET APPLIANCE OUTLET APPLIANCE INLET / OUTLET
uCombination
Approval based:
Rating:
Cable Type:
Strain Relief:
Cable O.D.:
VDE
EN 60320-1/EN60320-2-2
250 V ac / 16 A
H05VV-F3G 1.0 mm , Length max. 2 m
2
H05VV-F3G 1.5 - 2.5 mm2
H07RN-F3G 1.5 mm2
White chuck
6.0 - 12.0 mm
UL
UL 498 / CSA C22.2 No. 182.3
250 V ac / 20 A
SJTOW, SJOOW 3 x 12 AWG
White chuck
6.0 - 12.0 mm
Application:
The power TRUE1 system is certified as connector with breaking cap ity accordingCON aac
0625. an appliance coupler and interconnection coupler.IEC 60320, VDE It is intended for use as
anIt serves to supply power to appliance and from an appliance to other equipment.
To be installed by qualified person only.
power TRUE1 TOP line is full backward compatible with the preceding power TRUE1 products.CON CON
UL50E environmental rating
Enclosure Type 4 when mated with cord connector NAC3FX-W-TOP or mated with appliance outlet
NAC3FPX*-TOP with sealing cover SCNAC-FPX and NAC3PX-TOP with sealing cover SCNAC-PX.
20
250
P S
E
JET
16
250
20
250
NAC3MX-W
5.
20
250
P S
E
JET
16
250
20
250
NAC3MX-W
ASSEMBLY INSTRUCTION powerCON TRUE1 TOP - NAC3MX-W-TOP
I
R
Torque Value 0.7 Nm
Torque Value 2.0 Nm
PRESS FIRMLY
Torx size
T8
1.
2.
4.
6.
3.
Important:
Push and turn simultaneously.
G
E
F
Important:
Align r keyubber
latch.and
www.neutrik.com
Find more details of power TRUE1 TOP on www.neutrik.com.CON
Insert the wires into the terminals and fasten the
screw with Torx size T8.
Wiring VDE UL
blackLbrownÞ
whiteNblueÞ
green / yellow greenÞ
Slide the chuck onto the insert (1) and then both
together into housing (2).
Important: Align the chuck byand insert
positioning the nose into keyway.the
Slide the bushing up the cable tighten itand with
the tool as shown.
Important: Black O-ring to hide to achieve IP
protection (6).
(Tool available: Art. No. HTAC)
Page 2
LIECHTENSTEIN
20
250
P S
E
JET
CAUTION
To ensure protection
category, do not expose the
connection to bending forces
(e.g. do not attach loads to
the cable, no free-dangling
cable windings etc.).
FORCE
SAFETY WARNING
For safety and certification reasons the connector must be
replaced in case of any broken parts or .excessive wear and tear
2.
FOR DISASSEMBLY - OPEN TWIST LOCK!
1. Press with screw driver to unlock
Turn bushing 360°.2.
Repat step 1 + 2 until bushing is unscrewed.3.
Draft. Nr.: BDA 542 Update: .20111.07 8
II
Neutrik AG LI T: +423 / 237 24 24 F: +423 232 53 93/
Neutrik USA Inc. USA T: +1 704 / 972 3050 F: +1 704 438 9202/
Neutrik ()
UK Ltd. UK T: +44 1983 / 811441 F: +44 1983 811 439/
Neutrik Vertriebs GmbH DE/NL/AT/DK T: +49 8131 / 280 890 F: +49 8131 280 830/
Neutrik France FR T: +33 1 4131 6750 F: +33 1 4131 0511//
Neutrik Tokyo Ltd. JP T: +81 3 3663 4733 F: +81 3 3663 4796//
Neutrik Hong Kong Ltd. HK T: +852 2687 6055 F: +852 2687 6052//
Neutrik India Pvt. Ltd. IND T: + F: +91 22 26163 54091/ 982 05 43 424 /
Data subject to change without prior notice. 201 NEUTRIK ALL RIGHTS RESERVED8 . NEUTRIK are registered trademark of NEUTRI AG. .©®®
Wrench size
13 mm
1.
  • Page 1 1
  • Page 2 2

Neutrik NAC3MX-W-TOP Operating instructions

Type
Operating instructions

Neutrik NAC3MX-W-TOP is a power connector with breaking capacity, intended for use as an appliance coupler. It serves to supply power to an appliance and from an appliance to other equipment. The device is certified and approved by various organizations, ensuring its quality and safety. It is rated for 250V AC and 16A, with a cable type of H05VV-F3G 1.0 mm2 or H05VV-F3G 1.5 - 2.5 mm2. It features a strain relief with a white chuck and a cable O.D. of 6.0 - 12.0 mm. The device meets UL50E environmental rating and Enclosure Type 4 when mated with specific cord connectors or appliance outlets.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI