Freedom Innovations iQ Instructions For Use Manual

Type
Instructions For Use Manual

This manual is also suitable for

Freedom Innovations iQ is an advanced vacuum system designed to enhance your prosthetic experience. With its innovative features, it provides improved socket suspension, stability, and comfort. iQ's intelligent algorithms automatically adjust vacuum levels based on your activity, ensuring a secure fit throughout the day. Experience the freedom of movement and confidence with Freedom Innovations iQ.

Freedom Innovations iQ is an advanced vacuum system designed to enhance your prosthetic experience. With its innovative features, it provides improved socket suspension, stability, and comfort. iQ's intelligent algorithms automatically adjust vacuum levels based on your activity, ensuring a secure fit throughout the day. Experience the freedom of movement and confidence with Freedom Innovations iQ.

Instructions
for
Use
Freedom
iQVacuum
2
Contents
Device Components 4
Terms/Symbols Used In This Guide 4
Warnings/Safety Precautions 6
Product Description 7
Intended Use 7
Indications 7
Qualications 7
Product Specications – Physical Properties 7
Environmental Specications 7
Setup 8
Pylon Attachment 8
Maintenance & Cleaning 9
Vacuum Connection and Filter 9
Basic Operations 10
User Panel 10
Turn On 10
Turn O 10
Battery Life 10
Battery Level 10
Reset 11
Warning Indicators 11
Critical Error Indicators 11
Normal Function 11
Battery Charging 11
Freedom iQ Vacuum App for Prosthetists (iQ Vac App) 12
Dashboard 12
Adjust Vacuum Levels 12
Initial Training 12
Step Detection Setup 13
Adjust Target Step Rates 13
Outcomes and Engineering Reports 14
Freedom iQ Vacuum App (iQ Vac App) for Users 15
Interactions 15
Features and Options 15
Water Mode 15
Stop on Leak 16
Vent on Power O 16
Downloading and Launching App 16
Connecting and Pairing to iQ Vacuum via iQ Vac App 16
Disconnecting 16
Warranty 17
Technical Support 17
Electromagnetic Precautions 17
CE Conformity 18
Authorized Representative 18
iQ Vacuum Product Detail 19
Freedom Innovations | iQ Vacuum | Instructions for Use
Freedom
iQ Vacuum
54
Device Components
Part Description Part Number Included w/iQ Qty Available/Sold Separately
iQ Vacuum Device VAC-00-A1001-00 YES 1NO
Ø 29 mm Clamp Bushing VAC-00-P0101-01 YES 1YES
Ø 32,6 mm Clamp Bushing VAC-00-P0101-02 YES 1YES
Ø 34,8 mm Clamp Bushing VAC-00-P0101-03 YES 1YES
Filter Assembly VAC-00-A1011-00 YES 4YES
1,6 mm ID Tube OTS-39-00030-00 YES 1YES
3,2 mm 90 Degree Elbow Barb OTS-69-00010-00 YES 1YES
Pylon Bumper, Foam Tape OTS-32-00008-00 YES 1YES
AC/DC Wall Mount Adapter OTS-62-00006-00 YES 1YES
iQ Vacuum Device IFU IFU-03-004 YES 1YES
Terms/Symbols Used In This Guide
WEEE Directive on waste electrical and electronic
equipment, which should not be disposed of in regular
wastes at the end of its usable life
Serial number
S
N
Type BF applied part
FCC Declaration of Conformity
Manufacturer
Bluetooth
CE Mark
Battery
iQ Adaptive Vacuum Device
Consult operating instructions
Don Put on
Do Take o
CP Certied Prosthetist
Freedom Innovations | iQ Vacuum | Instructions for Use
76
Warnings / Safety Precautions
Failure to comply with safety precautions can result in iQ Vacuum
malfunctioning and risk of injury to the user. Please read the
instruction manual thoroughly before using.
Always exercise good judgment and common sense when using
iQ Vacuum.
Initial operating of iQ Vacuum should be done in the presence of a
trained care professional.
Do not attempt to open or modify any component of iQ Vacuum.
If any issues or concerns with the iQ Vacuum arise, contact a
Prosthetist for assistance. DO NOT attempt to make technical
repairs.
Do not continue to use the iQ Vacuum if the plastic cover enclosure
is broken.
Do not use iQ Vacuum while the battery is charging. Be sure to
disconnect it from the charger prior to putting on the prosthesis.
If it becomes necessary to isolate iQ Vacuum from the mains while
charging, unplug the battery charger.
If unusual movement or product wear is detected in a structural
part of a prosthesis at any time, immediately discontinue use of the
device and consult a clinical specialist.
iQ Vacuum contains a Lithium-polymer battery. Lithium-polymer
batteries contain hazardous materials and should never be disposed
of in residential or commercial garbage. They should never be
incinerated because they may explode. Reference local regulations
for proper disposal of product.
iQ Vacuum has small parts and a charging cord that can be a
potential choking hazard.
Product Description
Freedom iQ Vacuum is a microprocessor controlled, automatically
adjusting vacuum that monitors activity to control the amount of
pressure in the prosthetic socket for the changing needs of the user.
Intended Use
Freedom iQ Vacuum is intended for use by individuals with lower limb
amputations who would benet from improved socket environment
and physical connection to their prosthesis.
Indications
Freedom iQ Vacuum is indicated for use as a component in a prosthetic
leg for individuals with lower limb deciency including:
Persons or Individuals with unilateral or bilateral
transtibial amputations
Individuals with congenital limb loss below the knee
Qualications
Freedom iQ Vacuum should only be integrated in the prosthesis by
a trained O&P professional.
Product Specications – Physical Properties
No weight limit for users of all activity levels.
Average Product Weight: 271 g
Build Height: no additional build height for standard Pylon
(a minimum of 50,8 mm – 76,2 mm of pylon/adapters are required)
Suitable for ambulatory level: K2 – K4
iQ Vacuum is tested and compliant with the following standards:
IEC/EN60601-1
Environmental Specications
Operating Temperature Range: 0 to 45 °C
Storage Temperature Range: -25 to 70 °C
Humidity Range: 0 – 100%
Altitude Range: 0 – 3,350 m
Weather resistance: rated to IP67
- iQ Vacuum should be powered o or put into Water Mode if
submersion is anticipated.
- iQ Vacuum is safe for occasional submersion in fresh water
up to 1 m for up to 30 minutes.
The user should dry the device with a towel once out of the water.
- iQ Vacuum should not be used for bathing or showering.
- iQ Vacuum should not be immersed in salt water or chlorinated
water as these may cause corrosion.
Freedom Innovations | iQ Vacuum | Instructions for Use
98
Setup
iQ Vacuum is designed to not require additional build height by
clamping on to the prosthesis pylon or adapter. The amount of height
required between the socket and the foot depends upon the top prole
of the prosthetic foot chosen.
Pylon Attachment
Remove the front cover screw to reveal the clamp. Remove the two
clamp bolts. Select a rubber clamp bushing from the included kit to
wrap around the pylon or adapter. The clamp on the main body of
the iQ Vacuum unit should t snuggly against the pylon and rubber
shim. Position the unit as high as possible on the posterior side of the
prosthesis pylon. Take care that there is no contact with the socket or
the foot when mounted. If desired, the provided self-adhesive foam
pylon bumper should be attached at the bottom of the housing below
the serial number label. Attach the anterior clamp with the two clamp
bolts and tighten with a torque wrench to 5 Nm. Check that the unit
is held rmly and does not slip. You may have to choose a dierent
thickness of rubber clamp bumper if it is not secure, or if you cannot
tighten the clamp fully. If needed, you can attach the unit to any side
of prosthesis for a better t.
Maintenance & Cleaning
iQ Vacuum was designed for no internal service requirements for
the life of the device.
In order to maintain the IP67 rating, the external case of the iQ Vacuum
should never be open except for authorized service. The Water Mode
should always be activated when entering the water.
The external lter of the iQ Vacuum should be replaced every 6 months.
The iQ Vacuum Pump may be cleaned by wiping it using a soft cloth
with mild soap and water. Do not use any other solvents. Do not
immerse to clean.
Vacuum Connection and Filter
With iQ Vacuum securely fastened to the prosthesis, attach the lter
assembly with 3,2 mm tubing to the socket barb tting, which should
be as close to the bottom of the socket as practical.
Connect the 1,6 mm tubing to the lter assembly and route it to the
proximal barb on the iQ Vacuum pump. Ensure the tubing passes
through the proximal relief cutout in the housing. Cut the tubing to
length as necessary.
Filter Assembly
Cut Vacuum Line
Freedom Innovations | iQ Vacuum | Instructions for Use
1110
Basic Operations
User Panel
To manually control iQ Vacuum, use the button and LED indicator on
the top of iQ Vacuum. The button is used as both a power switch and
for limited interaction with iQ Vacuum when a mobile device is not
available or desired.
Power / Function Button
Battery / Function Indicator
Turn On
Don the prosthesis prior to turning on. Press and hold the center
button until the indicator light turns green, then release. A series of
green ashes follow to report the battery charge.
Indicator Light Charge Level
4 Green Flashes
3 Green Flashes
2 Green Flashes
1 Green Flash
75% – 100%
50% – 75%
25% – 50%
0% – 25%
The amber light turns on after battery report ashes, and indicates
that the pump is pulling vacuum to donning level.
Turn O
Press and hold the center button until the indicator light turns green,
then release. A green ash followed by an amber LED will indicate the
unit is o. The amber LED remains lit while a relief valve is held open
to aid in dong the prosthesis.
Battery Life
2 – 3 days under normal operating conditions.
Battery Level
A quick press of the button (while on or o) will display the battery
level according to the pattern above.
Reset
While plugged into its charger, press and hold the button for
15 seconds. The indicator light will turn amber when ready to reset.
Release the button and a ashing red light will indicate that the
rmware is resetting. If you decide not to reset, simply continue
pressing the button until the amber light turns o.
WARNING: A reset will erase all memory and restore factory settings.
Warning Indicators
The indicator will glow amber steadily under the following conditions:
Battery Low
Socket Seal Leak
Blockage of Vacuum
Unable to Reach Donning Vacuum Level
Critical Error Indicators
The indicator will ash red quickly for 10 seconds and the unit will turn
o automatically under the following conditions:
Battery Too Low to Continue
Unresolved Socket Seal Leak
Continuing Blockage of Vacuum
Normal Function
iQ Vacuum will initially start up in “Donning Mode” and will apply a
slight vacuum to the prosthetic socket. Intelligent diagnostics will test
the quality of the socket seal and then will enter “Auto Mode” where it
will automatically increase and decrease the vacuum level based on the
activity level of the user. If it is unable to achieve the donning level in a
short time, the warning indicator will illuminate amber. Check for leaks
in the socket or tubing connections and don the prosthesis again.
Battery Charging
To charge the battery:
Insert micro USB cable connector into port on side of iQ Vacuum.
Connect to the wall power supply provided with iQ Vacuum.
The indicator will slowly pulse green while charging.
Once the device is completely charged, the indicator light will
turn solid green.
CAUTION: Use only the wall power supply provided with iQ Vacuum
for charging its battery.
Freedom Innovations | iQ Vacuum | Instructions for Use
1312
Freedom iQ Vacuum App For Prosthetists (iQ Vac App)
Dashboard
After connecting to an iQ Vacuum unit, an information Dashboard
summarizes key setup and performance indicators. The live graph
at the bottom of the screen shows you how the socket vacuum is
changing and how the vacuum is responding to the live changing
activity of the user.
Adjust Vacuum Levels
While iQ Vacuum is fully automatic, the amount of vacuum targeted
at dierent activity levels is adjustable by the prosthetist by selecting
Controls>Settings>Vacuum Level.
Initial Training
For optimal automatic function, iQ Vacuum must be trained to
recognize the unique gait of the user. Before training, you may choose
to alter the standard target vacuum levels. In the Freedom iQ Vacuum
select Controls>Settings>Step Detection Setup. The app will lead you
through the process of tuning the iQ Vacuum sensor.
The process can be repeated by the prosthetist at any time in the
future should there be a question about the performance of the
adaptive control system, or if the target vacuum levels are changed.
Step Detection Setup
To use Step Detection Setup, have the user walk continuously. Each
time that the device observes a step, the gray circle in the middle will
ash green and there will be an audible beep. Make sure the sound
on your mobile device is turned on and the volume is up. There should
be one ash/beep for each step you observe. Ignore starting, stopping
and turning steps. After watching the user for several steps, tap the
control on the screen that reects if the device detected:“Too Few”,
“Too Many” or “Just Right” number of steps. Continue the process until
it is “Just Right”. Tap “Just Right” at the bottom of the screen. Be sure
to observe the user at a variety of cadences.
Adjust Target Step Rates
The vacuum level target increases with increasing activity levels
(Low, Medium, High) as dened by the target step rates. These are
adjustable by selecting Controls>Settings>Step Rate in the app menu.
You may want to increase the rate if you feel the device is going into
medium or high activity mode too early or you may want to decrease
the rates if the user does not achieve the higher activity levels.
Freedom Innovations | iQ Vacuum | Instructions for Use
1514
Outcomes and Engineering Reports
iQ Vacuum is designed to collect and provide both performance and
qualitative outcomes of the prosthesis user. Select Report from the
bottom right of the main screen, or tap Controls>Create Usage Report.
The report on screen may be emailed, le transferred, or printed
depending on the mobile device you are using.
An Engineering Report can be created in .CSV format by selecting
Controls>Device>Engineering Report. The Engineering Report oers
more detailed session data for the last 100 sessions of use.
Freedom iQ Vacuum App (iQ Vac App) for Users
Interactions
The iQ Vac App for users allows the user to interact with
iQ Vacuum on a more limited basis:
View Battery Charge Level
View Current Activity Level
View Seal Quality
View Step Counts (Current session and lifetime)
Activity Level Step Rates
View Target and Live Vacuum Levels
View Warning Details
Create Outcomes Report to Send to Prosthetist
Set A Custom Name For The Device
Set The Service Date When The Vacuum Filter Is Changed
NOTE: User will not be able to connect via the iQ Vac App when
iQ Vacuum is simultaneously connected to another mobile device.
WARNING: Users should not watch the screen on their mobile
device while walking.
Features and Options
The iQ Vac App allows users to customize their interactions with
the iQ Vacuum.
Water Mode
Users can safely enter the water with the iQ Vacuum
by activating Water Mode. Select Water Mode from the
Dashboard screen and then select a target vacuum level
as prompted. The iQ Vacuum will pump to that level for
30 seconds before shutting down and disconnecting from the iQ Vac
App. After the pump has shut down, the user can safely enter the
water without fear of damaging the device. Once out of the water,
resume use of the iQ Vacuum by powering it on once again and
reconnecting to the iQ Vac App. Once powered back on, the iQ Vacuum
will return to normal mode.
WARNING: Users should ensure that there is no water intrusion into
the socket of their prosthesis before turning the device back on.
Water inside the socket will be pumped through the device and may
cause damage.
Freedom Innovations | iQ Vacuum | Instructions for Use
1716
Stop on Leak
The user may toggle the Stop on Leak feature on or o from the
Settings menu (Controls>Settings>Misc). While toggled on, the Stop
on Leak feature will automatically power down the iQ Vacuum when
a faulty seal is detected, preventing continuous running and possible
damage. In circumstances where the user desires to continue
wearing the prosthesis in spite of a leak, toggling Stop on Leak o
will cause the iQ Vacuum to alternate between pump and rest, instead
of turning o.
Vent on Power O
The Vent on Power O feature is available to users through the
Settings menu (Controls>Settings>Misc). The Vent on Power O
feature enables the user to set a time in seconds that the iQ Vacuum
should vent vacuum (allow air to come in) each time it is powered
down, helping users in removing their prosthesis.
Downloading and Launching App
Download the iQ Vac App from the Apple App Store or the
Google Play App Store.
Connecting and Pairing to iQ Vacuum via iQ Vac App
Once App is open, tap the “Connect” button.
Tap the ID number (or custom name) of the iQ Vacuum to connect.
NOTE: When connecting to iQ Vacuum with a mobile device for the
rst time, the iQ Vac App will instruct the user to hold their mobile
device very close to the iQ Vacuum unit to ensure this is an authorized
wireless request.
Disconnecting
When you are done interacting with iQ Vacuum, select
Controls>Disconnect to disconnect the Bluetooth connection to
iQ Vacuum. This will conserve battery power.
Warranty
Purchase of the iQ Vacuum includes a 24-month warranty covering all
manufacturer defects eective only if the product is used according to
manufacturer recommendations.
Technical Support
For User Support, please contact Prosthetist.
For Prosthetist Technical Support or supplementary training
material please contact Freedom Innovations at +31 53 20 30 300.
Electromagnetic Precautions
The Freedom iQ Vacuum needs special precautions regarding
electromagnetic compatibility (EMC). Specically it needs to be
installed and put into service according to the EMC information
provided as follows:
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
Guidance and Manufacturer’s Declaration
– Electromagnetic Emissions
iQ Vacuum is intended for use in the electromagnetic environment
specied below. The customer or user of iQ Vacuum should assure that
it is used in such an environment.
Emissions
Test Compliance Electromagnetic Environment –
Guidance
RF Emissions
EN 55011/CISPR
Group 1 iQ Vacuum uses RF energy only for
internal functions. Therefore, its RF
emissions are low and are not likely
to cause any interference in nearby
electronic equipment.
RF Emissions
EN 55011/CISPR
Class B iQ Vacuum is suitable for use in all
establishments, including domestic
establishments and those directly
connected to the public low-voltage
power supply network that supplies
buildings used for domestic purposes.
Freedom Innovations | iQ Vacuum | Instructions for Use
1918
iQ Vacuum Product Detail
D
CE Conformity
The Freedom iQ Vacuum is tested and certied to comply
with the MDD 93/42/EEC (EN 55011 Class B and IEC60601-1
and IEC60601-1-3), STSI EN 300-328 under R&TTE Directive
1999/5/EC and, ISO10328. The device complies with Part 15
of the FCC Rules and carries the CE mark.
Authorized Representative
Advena Ltd.
Pure Oces
Plato Close, Warwick, CV 34 6 WE
United Kingdom
A. Power/Function Button
B. Micro USB Charging port
C. Pylon Clamp
D. Foam Pylon Support Pad Location
1
2
3
Basic Button Functions
Press and hold until indicator light turns green then release
Quick tap (less than 1/2 second) to report battery level when On or O
Quick tap (less than 1/2 second) to restart donning mode if failed
B
A
C
Freedom Innovations | iQ Vacuum | Instructions for Use
Freedom Innovations Europe B.V.
Jaargetijdenweg 4
7532 SX Enschede
The Netherlands
Tel.: +31(0)53-20 30 300
Fax: +31(0)53-20 30 305
www.freedom-innovations.eu
© 2019 Freedom Innovations Europe B.V. All rights reserved.
iQ Vacuum is a trademark of Freedom Innovations, LLC.
IFU-03-004 Rev. A - iQ Vacuum Instructions for Use, English EU
Connect with us
#freedominnovations
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Freedom Innovations iQ Instructions For Use Manual

Type
Instructions For Use Manual
This manual is also suitable for

Freedom Innovations iQ is an advanced vacuum system designed to enhance your prosthetic experience. With its innovative features, it provides improved socket suspension, stability, and comfort. iQ's intelligent algorithms automatically adjust vacuum levels based on your activity, ensuring a secure fit throughout the day. Experience the freedom of movement and confidence with Freedom Innovations iQ.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI